The Influence of Matching Flameresistant Materials on the Thermal Protective Performance of Firefighter Uniform

2014 ◽  
Vol 1052 ◽  
pp. 547-554
Author(s):  
Hua Zhang ◽  
Yan Gao ◽  
Zhong Qiang Wang ◽  
Mei Tong ◽  
Jie Zhang

Firefighter uniform made of various flame retardant materials is put as the object. Analyzing the thermal protective performance of different composite structures covering outer fabrics, lagging materials and comfortable layer materials, discuss the best combination of supporting structures. Adoption flash fire simulation, verify the integrated prevention ability of firefighter uniform. The matching of different levels has a significant impact on the thermal protective performance, first the outer layer, then comfortable layer and thermal protective coating. Although inherent fire resistant fiber for the main material of the outer fabric has better durability and thermal protective performance, the fire might experience obvious contraction which leads to embrittlements. For insulation flocculus, the ratio of aramid fiber 1313 and aramid fiber 1414 at 9:1 has excellent thermal insulation. For comfortable layer, inherent fire resistant fiber has no notable effect on the clothing’s overall thermal protection performance; the polysulfonamide fiber is a relative better choice.

2013 ◽  
Vol 821-822 ◽  
pp. 233-236
Author(s):  
Xiao Hui Li ◽  
Min Wang ◽  
Jun Li

Objective and quantitative evaluation of garment thermal protective performance should be based on the simulation of human in actual thermal environments as realistic as possible. In this paper, by using a new type of flame manikin which can rotate and make different postures, the dynamic scene where a firefighter wearing fire protective ensembles rescue in the flash fire was simulated. The skin burn prediction result showed that the total burn percent suffered by the manikin was 7.76%, of which the 2nd degree burn and the 3rd degree burn was 5.12% and 2.64% respectively. This indicated that the firefighter ensembles exhibited relatively good thermal protective performance. It can provide enough protection for the firefighter in 8s dynamic exposure while more protection should be added to the head.


2004 ◽  
Vol 74 (12) ◽  
pp. 1033-1040 ◽  
Author(s):  
Guowen Song ◽  
Roger L. Barker ◽  
Hechmi Hamouda ◽  
Andrey V. Kuznetsov ◽  
Patirop Chitrphiromsri ◽  
...  

2020 ◽  
Vol 20 (6) ◽  
pp. 109-114
Author(s):  
Hoseung Ro ◽  
Hyunpil Hong ◽  
Jinwon Cho ◽  
Myuongsu Park

To develop industrial and firefighter thermal protection cloth, 12 base fabrics were prepared from a combination of several types of sample, and their thermal performances were evaluated. Thermal performance comprises flame retardant capability, radiant protective performance, and thermal protective performance. Thermal protection performance has been assessed in accordance with ISO 15025, ISO 9151, ISO 6942, and ISO 17492. In this study, however, thermal protective performance was assessed only in accordance with ISO 15025. The results showed that Samples 1-6 satisfied the fire resistance criteria, whereas Samples 7-12 did not satisfy the fire resistance criteria. Additional thermal performance tests need to be conducted in follow-up studies.


2019 ◽  
Vol 69 (06) ◽  
pp. 458-465
Author(s):  
NAEEM JAWAD ◽  
ADNAN MAZARI ◽  
AKCAGUN ENGIN ◽  
HAVELKA ANTONIN ◽  
KUS ZDENEK

This experimental work is an effort to seek the possibility of improvement in thermal protective performance of firefighter protective clothing at different levels of heat flux density. Improvement in thermal protective performance means enhancement in the time of exposure against the heat flux, which will provide extra time to firefighters to perform their duties without suffering from severe injuries. Four different multilayer combinations of firefighter protective clothing were investigated. Each combination consists of outer shell, moisture barrier and thermal liner. Aerogel sheet was also employed as a substitute to thermal barrier. Initially, properties like thermal resistance, thermal conductivity, and water vapor resistance of multilayer fabric assemblies were investigated. Later on these combinations were exposed to different levels of radiant heat flux density i.e. at 10, 20 and 30 kW/m2 as per ISO 6942 standard. It was noted that those combinations in which aerogel blanket was used as thermal barrier acquire greater thermal resistance, water vapor resistance and have less transmitted heat flux density values.


Materials ◽  
2020 ◽  
Vol 13 (16) ◽  
pp. 3579
Author(s):  
Miao Tian ◽  
Qi Wang ◽  
Yiting Xiao ◽  
Yun Su ◽  
Xianghui Zhang ◽  
...  

The application of fire-retardant fabrics is essential for providing thermal protective function of the garments. Appropriate clothing design are beneficial for preventing the wearers from skin burn injuries and heat strains simultaneously. The intention of this work was to investigate the effects of clothing ventilation designs on its thermal protective performance by bench-scale tests. Four boundary conditions were designed to simulate the garment aperture structures on fabric level. Tests of thermal shrinkage, mass loss and time-to-second-degree-burns were performed with and without air gap under three heat-flux levels for two kinds of inherently fire-retardant fabrics. The impacts of fabric type, heat-flux level, air gap and boundary condition were analyzed. The presence of a 6.4-mm air gap could improve thermal protective performance of the fabrics, however, the garment openings would decrease this positive effects. More severe thermal aging found for spaced test configuration indicated the importance of balancing the service life and thermal protective performance of the clothing. The findings of this study implied that the characteristics of fabric type, air gap, boundary condition, and their effects on fabric thermal aging should be considered during clothing ventilation designs, to balance the thermal protection and comfort of the protective gear.


2017 ◽  
Vol 88 (20) ◽  
pp. 2339-2352 ◽  
Author(s):  
Sumit Mandal ◽  
Simon Annaheim ◽  
Thomas Pitts ◽  
Martin Camenzind ◽  
René M Rossi

This study aims to investigate the thermal protective performance of fabrics used in firefighters' clothing under high-intensity fire exposure. The performance of thermal protective fabric systems with different physical properties was evaluated under laboratory simulated fire exposure. Additionally, the influence of the configuration of the fire exposure tests and modes of heat transfer through the fabrics was also thoroughly investigated. The protective performance was evaluated using the standard small-scale flame [International Organization for Standardization (ISO) 9151:1995] and radiant heat (ISO 6942:2002) exposure tests. Additionally, the protective performance was evaluated under flash-fire exposure using a newly developed hexagon test. The protective performance values obtained from the small-scale (flame and radiant heat) and hexagon (flash fire) tests were compared and discussed. It has been found that a multi-layered fabric with high weight, thickness, and thermal resistance can significantly and positively affect the protective performance. If the air permeability of this fabric is high, it can show a lower protective performance; however, the impact of air permeability on the protective performance is insignificant especially in the case of the hexagon test. Notably, the protective performance can differ under two types of small-scale tests − flame and radiant heat. Also, this protective performance value is generally higher in the case of hexagon test in comparison with the small-scale tests. These differences in protective performance are mainly due to the unique configurations of these tests and/or different modes of heat transfer through the tested fabrics. The findings from this study will guide textile or materials engineers in the design and selection of materials for high performance thermal protective clothing; in turn, it will improve the occupational health and safety for firefighters.


2013 ◽  
Vol 796 ◽  
pp. 607-612
Author(s):  
Fei Fei Li ◽  
Chun Qin Zheng ◽  
Guan Mei Qin ◽  
Xiao Hong Zhou

Thermal insulation and flame-retardant (TIFR) protective clothing, which has good thermal protective performance (TPP), could protect people from high-temperature or flame in casting industry, the petrochemical industry, fire industry and et al. That is, TIFR protective clothing must have certain function of slowing or restraining heat transmission, and insulating radiant heat and convection heat from high temperature heat source. The construction of TIFR protective clothing is being developed from single layer to multi-layer fabrics made by flame-retardant (FR) fibre. In this paper, based on TPP-206 tester, the TPP coefficient of single and multi-layer fabrics with flame-retardant were measured, and the TPP of TIFR protective clothing was analyzed. TPP coefficient of single fabrics included the FR viscose non-woven fabric do not meet the standard. That of all of multi-layer fabrics meet the standard requirement, and the FR viscose/wool blended fabric is not suitable for fire fighter. It is significant and the most observable effect to put the PTFE membrane between the outer layer and the insulating layer. It could improve the overall thermal protection performance.


2017 ◽  
Vol 88 (16) ◽  
pp. 1847-1861 ◽  
Author(s):  
Hui Zhang ◽  
Guowen Song ◽  
Yiming Gu ◽  
Haitao Ren ◽  
Juan Cao

Firefighters wearing protective clothing perspire profusely in the process of performing their duties, and sweat increases moisture in the inner layers of multilayer protective clothing. Also, the outer shell fabrics inevitably become wet. In this study, two kinds of outer shell fabrics (aramid IIIA fabric and aramid 1313 and flame-retardant viscose-blended fabric) and three kinds of thermal liner fabrics with different thicknesses were selected. Two wetness conditions were investigated to simulate the sweating in thermal liner fabric with or without the wet outer shell fabric. A modified thermal protective performance (TPP) tester was employed to explore the effects of moisture and its distribution on stored thermal energy developed in six fabric systems and on TPP under flash exposure. Pearson correlations were established to analyze the relationships of the fabric systems’ thickness and second-degree burn time, and of absorbed energy and second-degree burn time in different configurations. The statistical analysis from these obtained data indicated that the thickness of fabric systems had no significant correlation for second-degree burn time ( p > 0.05), but the absorbed energy exhibited a strong relation (the lowest R2 value could reach 0.8070 and p-values were all much less than 0.05). Performance results for the wet thermal liner indicated that the negative impact on thermal protection reached the greatest degree in 15% wetness, but in some extreme situations (100% wetness), the performance was improved (the maximum increase can achieve 116.2% over performance in dry condition). However, the existing moisture in the outer shell showed a positive effect. These findings will enable the engineering of textile materials that achieve high performance protection from thermal hazards and give some guidance to firefighters during operations.


2014 ◽  
Vol 1004-1005 ◽  
pp. 1432-1436
Author(s):  
Liu Yang ◽  
Jian Zhong Yang ◽  
Long Li

This paper studies the fire taking multi-layer fabric thermal protection performance of the system, respectively from the single thermal protective performance of fabric and ten kinds of multilayer composite fabric through analyzing the thermal protective performance, The following conclusions: in terms of single flame retardant fabrics, for the same fabric fiber composition, the TPP value with the thickness of the fabric, square meter weight has significant positive correlation. Experimental results show that multi-layer combination of 8 # protective performance is best, flame retardant protective performance is the most suitable for fire-fighting suits fabrics.


2014 ◽  
Vol 26 (3) ◽  
pp. 235-246 ◽  
Author(s):  
Akram Hassan Mohammed Ali ◽  
Weidong Yu

Purpose – The purpose of this paper is to investigate thermal protection provided by the fire fighting fabric systems with different layer under high-level thermal hazards with a typical temperature range of 800-1,000°C. The purpose of these fabric systems was to provide actual protection against burn injuries using garments worn by industrial workers, fire fighters and military personnel, etc. Design/methodology/approach – The fabric system was consist of glass with aluminum foil as an outer layer, non-woven basalt, non-woven glass fabric containing NaCl-MgCl2 and Galactitol phase change materials (PCM) which simulate multilayer fire fighter protective clothing system. Thermal protective performance tests were applied for thermal analysis and used as an attempt to quantify the insulating characteristics of fabrics under conditions of flash over temperature. The surface of fire fighting multilayer protective fabric has been characterized using the UV-Vis-NIR (ultraviolet-visible-near infrared) spectrophotometer Findings – The clothing shows good thermal insulation and high-temperature drop during flash over environment and avoid second degree burn. The current PCM obvious advantages such as the ability to work in high temperature, high efficiency a long period of practical performance. Originality/value – Using this design of composite multilayer technology incorporating two stages of PCM may provide people with better protection against the fire exposure and increasing the duration time which was estimated to be more than five minutes to prevent burn injuries.


Sign in / Sign up

Export Citation Format

Share Document