Effect of Hot Treatment Process on High Performance Alloy Spring Steel D701 Mechanics Properties

2007 ◽  
Vol 353-358 ◽  
pp. 1641-1644
Author(s):  
Hui Ju Gao ◽  
Pan Liu ◽  
Jia He Ai ◽  
Jian Xin Dong ◽  
Xi Shan Xie ◽  
...  

High performance alloy spring steel D701 for accelerated railway wagons is improved 60Si2CrVA steel. Its properties have been better than 60Si2CrVA steel.The difference between of them is using controlled rolling process for D701 steel.The affect of hot treatment process was studied by orthogonal test on D701 steel property in the article. The mechanical property σs is 1800MPa; σb is 1925MPa; δ is 9.5%, ψ is 36.5%.

2015 ◽  
Vol 671 ◽  
pp. 197-201
Author(s):  
Lei Zhang ◽  
Zhu Zhan ◽  
Xiao Hong Zhou

To improve the adhesion between high-performance polyester fabric and silicone, the cold plasma technology was employed in this paper. And the process was optimized through orthogonal test. The changes in the surface morphology of high-performance polyester fabric processed by cold plasma technology were observed. And the mechanical property of the silicone layered with the fabric was also measured. The optimum process for increasing the roughness of the fiber surface but keeping its strength are 3min of treatment time, 80W of power output and 30Pa of gas pressure. The strength and the modulus of the silicone layered with the fabric processed by cold plasma technology can be increased by 8.61% and12.03%.


Author(s):  
R. Levi-Setti ◽  
J. M. Chabala ◽  
R. Espinosa ◽  
M. M. Le Beau

We have shown previously that isotope-labelled nucleotides in human metaphase chromosomes can be detected and mapped by imaging secondary ion mass spectrometry (SIMS), using the University of Chicago high resolution scanning ion microprobe (UC SIM). These early studies, conducted with BrdU- and 14C-thymidine-labelled chromosomes via detection of the Br and 28CN- (14C14N-> labelcarrying signals, provided some evidence for the condensation of the label into banding patterns along the chromatids (SIMS bands) reminiscent of the well known Q- and G-bands obtained by conventional staining methods for optical microscopy. The potential of this technique has been greatly enhanced by the recent upgrade of the UC SIM, now coupled to a high performance magnetic sector mass spectrometer in lieu of the previous RF quadrupole mass filter. The high transmission of the new spectrometer improves the SIMS analytical sensitivity of the microprobe better than a hundredfold, overcoming most of the previous imaging limitations resulting from low count statistics.


SLEEP ◽  
2020 ◽  
Author(s):  
Evan D Chinoy ◽  
Joseph A Cuellar ◽  
Kirbie E Huwa ◽  
Jason T Jameson ◽  
Catherine H Watson ◽  
...  

Abstract Study Objectives Consumer sleep-tracking devices are widely used and becoming more technologically advanced, creating strong interest from researchers and clinicians for their possible use as alternatives to standard actigraphy. We therefore tested the performance of many of the latest consumer sleep-tracking devices, alongside actigraphy, versus the gold-standard sleep assessment technique, polysomnography (PSG). Methods In total, 34 healthy young adults (22 women; 28.1 ± 3.9 years, mean ± SD) were tested on three consecutive nights (including a disrupted sleep condition) in a sleep laboratory with PSG, along with actigraphy (Philips Respironics Actiwatch 2) and a subset of consumer sleep-tracking devices. Altogether, four wearable (Fatigue Science Readiband, Fitbit Alta HR, Garmin Fenix 5S, Garmin Vivosmart 3) and three non-wearable (EarlySense Live, ResMed S+, SleepScore Max) devices were tested. Sleep/wake summary and epoch-by-epoch agreement measures were compared with PSG. Results Most devices (Fatigue Science Readiband, Fitbit Alta HR, EarlySense Live, ResMed S+, SleepScore Max) performed as well as or better than actigraphy on sleep/wake performance measures, while the Garmin devices performed worse. Overall, epoch-by-epoch sensitivity was high (all ≥0.93), specificity was low-to-medium (0.18-0.54), sleep stage comparisons were mixed, and devices tended to perform worse on nights with poorer/disrupted sleep. Conclusions Consumer sleep-tracking devices exhibited high performance in detecting sleep, and most performed equivalent to (or better than) actigraphy in detecting wake. Device sleep stage assessments were inconsistent. Findings indicate that many newer sleep-tracking devices demonstrate promising performance for tracking sleep and wake. Devices should be tested in different populations and settings to further examine their wider validity and utility.


2019 ◽  
Vol 485 (3) ◽  
pp. 3370-3377 ◽  
Author(s):  
Lehman H Garrison ◽  
Daniel J Eisenstein ◽  
Philip A Pinto

Abstract We present a high-fidelity realization of the cosmological N-body simulation from the Schneider et al. code comparison project. The simulation was performed with our AbacusN-body code, which offers high-force accuracy, high performance, and minimal particle integration errors. The simulation consists of 20483 particles in a $500\ h^{-1}\, \mathrm{Mpc}$ box for a particle mass of $1.2\times 10^9\ h^{-1}\, \mathrm{M}_\odot$ with $10\ h^{-1}\, \mathrm{kpc}$ spline softening. Abacus executed 1052 global time-steps to z = 0 in 107 h on one dual-Xeon, dual-GPU node, for a mean rate of 23 million particles per second per step. We find Abacus is in good agreement with Ramses and Pkdgrav3 and less so with Gadget3. We validate our choice of time-step by halving the step size and find sub-percent differences in the power spectrum and 2PCF at nearly all measured scales, with ${\lt }0.3{{\ \rm per\ cent}}$ errors at $k\lt 10\ \mathrm{Mpc}^{-1}\, h$. On large scales, Abacus reproduces linear theory better than 0.01 per cent. Simulation snapshots are available at http://nbody.rc.fas.harvard.edu/public/S2016.


2011 ◽  
Vol 704-705 ◽  
pp. 1465-1472
Author(s):  
Jin Wu ◽  
Da Sen Bi ◽  
Liang Chu ◽  
Jian Zhang ◽  
Yun Tao Li

Dual phase (DP) steel is a high strength steel for auto-panel. In this paper, mechanical property, forming ability, baked-hardening and work hardening properties of high strength steel DP450 are studied by experiments, and compared with those of steel MS6000.And theoretical research on predicting the forming limit of steel DP450 by the NADDRG model. The established mathematic model for relativity is of practical usefulness. Experimental results reveal that the yield strength of steel DP450 is about 7.2% lower than the MS6000,and the break strength increases by 18.9%,while the elongation increases by 19%.The strain hardening exponent of steel DP450 are superior to those of MS6000.The results show that mechanical property of high strength steel DP450 is better than that of MS6000,while forming ability of DP450 is not lower than that of MS6000.And baked-hardening and work hardening properties of steel DP450 are better than those of MS6000.The steel sheet DP450 owned a good forming ability.


2013 ◽  
Vol 641-642 ◽  
pp. 574-577 ◽  
Author(s):  
Ying Tao Li ◽  
Ling Zhou ◽  
Mao Jiang ◽  
Yu Zhang ◽  
Jun Shao

In this paper, the mechanical property experiments of concrete based on the seawater and sea sand have been carried in different raw materials preparation and different conservation environments. The results show that the early strength and late strength of concrete based on seawater and sea sand are better than concrete based on freshwater and sand. There is no significant strength decreased for concrete based on seawater and sea sand under accelerated alternating wet and dry conditions. For concrete based on seawater and sea sand mixed with admixture, the downward trend of late strength is significantly delayed, the late strength of concrete based on the seawater and sea sand mixed with slag gets the most obvious growth trend, while the late strength of seawater and sea sand concrete mixed with fly ash gets the largest increment.


2013 ◽  
Vol 405-408 ◽  
pp. 1815-1819
Author(s):  
Wen Sheng Yu ◽  
Zhu Long Li ◽  
Xiao Ru Xie ◽  
Li Yuan Guo

To analyze the earth pressure of corrugated steel culvert under high fill embankment, a field test was taken and the change law was got with the filling height increasing, the force state when geotechnical grilles were laid on the top of corrugated steel culvert was compared to that of reinforced concrete slab culvert. Results show that the pressure on the top of corrugated steel culvert is smaller than that on the external in same level when test points are near to culvert, the values of test points above and below geotechnical grilles are close, and the pressure of corrugated steel culvert is smaller than that of reinforced concrete slab culvert when filling height is above 7.3 m. So analysis indicates corrugated steel culvert spreads the upper load better, the geotechnical grille can reduce the pressure effectively through earth pressure redistribution, and the mechanical property of corrugated steel culvert is better than reinforced concrete slab culvert under high fill embankment.


1998 ◽  
Vol 514 ◽  
Author(s):  
D. Edelstein

ABSTRACTRecently IBM announced the first implementation of full copper ULSI wiring in a CMOS technology, to be manufactured on its high-performance 0.22 um CMOS products this year. Features of this technology will be presented, as well as functional verification on CMOS chips. To reach this level, extensive yield, reliability, and stress testing had to be done on test and product-like chips, including those packaged into product modules. Data will be presented fom all aspects of this testing, ranging from experiments designed to promote Cu contamination of the MOS devices, to temperature/humidity/bias stressing of assembled functional modules. The results in all areas are shown to be equal to or better than standards set by our current AI(Cu)/Wstud technology. This demonstrates that the potential problems associated with copper wiring that have long been discussed can be overcome.


Author(s):  
P. Laurent ◽  
F. Acero ◽  
V. Beckmann ◽  
S. Brandt ◽  
F. Cangemi ◽  
...  

AbstractBased upon dual focusing techniques, the Polarimetric High-Energy Modular Telescope Observatory (PHEMTO) is designed to have performance several orders of magnitude better than the present hard X-ray instruments, in the 1–600 keV energy range. This, together with its angular resolution of around one arcsecond, and its sensitive polarimetry measurement capability, will give PHEMTO the improvements in scientific performance needed for a mission in the 2050 era in order to study AGN, galactic black holes, neutrons stars, and supernovae. In addition, its high performance will enable the study of the non-thermal processes in galaxy clusters with an unprecedented accuracy.


Sign in / Sign up

Export Citation Format

Share Document