Estudy of Natural and Degradation by Salt Spray of Red Ceramics Incorporated with Ornamental Rock Waste

2012 ◽  
Vol 727-728 ◽  
pp. 1519-1524 ◽  
Author(s):  
Larissa Machado Altoé ◽  
Gustavo de Castro Xavier ◽  
Fernando Saboya Albuquerque ◽  
Paulo César de Almeida Maia ◽  
Jonas Alexandre ◽  
...  

To better study the mechanical behavior of red ceramic, the samples were degraded in salt spray equipment and exposed in environment. The salt spray equipment subjects the samples to conditions found by the sea, through the mix solutions of sodium chloride. The ceramic samples were prepared with up to 10% by mass of ornamental rock waste to dry and pressed into rectangular mold of steel. The materials were fired at temperatures of 650°C, 750°C and 850°C. After 90 days of degradation natural and 45 days in salt spray, ware analyzed the properties of ceramic material. The results of mechanical strength were compared using the Weibull distribution, before and after the degradation. Note that the material with ornamental rock waste raised the mechanical strength and didnt significantly changes the material properties after degradation.

Author(s):  
Mohammed Salah Bennouna ◽  
Benaoumeur Aour ◽  
Fatiha Bouaksa ◽  
Saad Hamzaoui

In this paper an experimental investigation of mechanical behavior of a thermoplastic polymer (polyamide PA 66) processed by constrained groove pressing (CGP) using several passes is presented. To this end, corrugating and straightening tools are designed and manufactured. The effects of the number of passes and the hold time on the mechanical behavior of the polyamide have been highlighted. The obtained results show that the material properties and the microstructure are significantly altered under CGP process. It has been found that the microhardness and the tensile properties have been progressed accordingly to the number of cycles, especially when the samples are processed using a hold time of five minutes. Hence, it can be concluded that this latter plays a very important role on the reorientation and stabilization of the microstructure when the processed material is a polymer.


2015 ◽  
Vol 651-653 ◽  
pp. 677-682 ◽  
Author(s):  
Anatoliy Popovich ◽  
Vadim Sufiiarov ◽  
Evgenii Borisov ◽  
Igor Polozov

The article presents results of a study of phase composition and microstructure of initial material and samples obtained by selective laser melting of titanium-based alloy, as well as samples after heat treatment. The effect of heat treatment on microstructure and mechanical properties of specimens was shown. It was studied mechanical behavior of manufactured specimens before and after heat treatment at room and elevated temperatures as well. The heat treatment allows obtaining sufficient mechanical properties of material at room and elevated temperatures such as increase in ductility of material. The fractography of samples showed that they feature ductile fracture with brittle elements.


Author(s):  
Joseph Park ◽  
Andrew Shin ◽  
Somaye Jafari ◽  
Joseph L. Demer

AbstractThe optic nerve (ON) is a recently recognized tractional load on the eye during larger horizontal eye rotations. In order to understand the mechanical behavior of the eye during adduction, it is necessary to characterize material properties of the sclera, ON, and in particular its sheath. We performed tensile loading of specimens taken from fresh postmortem human eyes to characterize the range of variation in their biomechanical properties and determine the effect of preconditioning. We fitted reduced polynomial hyperelastic models to represent the nonlinear tensile behavior of the anterior, equatorial, posterior, and peripapillary sclera, as well as the ON and its sheath. For comparison, we analyzed tangent moduli in low and high strain regions to represent stiffness. Scleral stiffness generally decreased from anterior to posterior ocular regions. The ON had the lowest tangent modulus, but was surrounded by a much stiffer sheath. The low-strain hyperelastic behaviors of adjacent anatomical regions of the ON, ON sheath, and posterior sclera were similar as appropriate to avoid discontinuities at their boundaries. Regional stiffnesses within individual eyes were moderately correlated, implying that mechanical properties in one region of an eye do not reliably reflect properties of another region of that eye, and that potentially pathological combinations could occur in an eye if regional properties are discrepant. Preconditioning modestly stiffened ocular tissues, except peripapillary sclera that softened. The nonlinear mechanical behavior of posterior ocular tissues permits their stresses to match closely at low strains, although progressively increasing strain causes particularly great stress in the peripapillary region.


2005 ◽  
Vol 127 (7) ◽  
pp. 1158-1167 ◽  
Author(s):  
Adam H. Hsieh ◽  
Diane R. Wagner ◽  
Louis Y. Cheng ◽  
Jeffrey C. Lotz

In vivo rodent tail models are becoming more widely used for exploring the role of mechanical loading on the initiation and progression of intervertebral disc degeneration. Historically, finite element models (FEMs) have been useful for predicting disc mechanics in humans. However, differences in geometry and tissue properties may limit the predictive utility of these models for rodent discs. Clearly, models that are specific for rodent tail discs and accurately simulate the disc’s transient mechanical behavior would serve as important tools for clarifying disc mechanics in these animal models. An FEM was developed based on the structure, geometry, and scale of the mouse tail disc. Importantly, two sources of time-dependent mechanical behavior were incorporated: viscoelasticity of the matrix, and fluid permeation. In addition, a novel strain-dependent swelling pressure was implemented through the introduction of a dilatational stress in nuclear elements. The model was then validated against data from quasi-static tension-compression and compressive creep experiments performed previously using mouse tail discs. Finally, sensitivity analyses were performed in which material parameters of each disc subregion were individually varied. During disc compression, matrix consolidation was observed to occur preferentially at the periphery of the nucleus pulposus. Sensitivity analyses revealed that disc mechanics was greatly influenced by changes in nucleus pulposus material properties, but rather insensitive to variations in any of the endplate properties. Moreover, three key features of the model—nuclear swelling pressure, lamellar collagen viscoelasticity, and interstitial fluid permeation—were found to be critical for accurate simulation of disc mechanics. In particular, collagen viscoelasticity dominated the transient behavior of the disc during the initial 2200s of creep loading, while fluid permeation governed disc deformation thereafter. The FEM developed in this study exhibited excellent agreement with transient creep behavior of intact mouse tail motion segments. Notably, the model was able to produce spatial variations in nucleus pulposus matrix consolidation that are consistent with previous observations in nuclear cell morphology made in mouse discs using confocal microscopy. Results of this study emphasize the need for including nucleus swelling pressure, collagen viscoelasticity, and fluid permeation when simulating transient changes in matrix and fluid stress/strain. Sensitivity analyses suggest that further characterization of nucleus pulposus material properties should be pursued, due to its significance in steady-state and transient disc mechanical response.


2007 ◽  
Vol 336-338 ◽  
pp. 2406-2410
Author(s):  
Yi Wang Bao ◽  
Xiao Xue Bu ◽  
Yan Chun Zhou ◽  
Li Zhong Liu

A relative method, defined as indirect approach to evaluate the material properties via the relationship between unknown properties and a known property, is proposed to estimate some properties that could not be measured by the traditional methods for ceramics. Experiments and theoretic analysis based on the relative method were carried out in this study to estimate the properties in following aspects: determining the temperature dependence of elastic modulus of some machineable ceramics by comparing the deflections; obtaining the modulus and strength of ceramic coatings supported by substrates, from the variation in properties of the rectangular beam samples before and after coating; estimating the residual stresses in tempered glass by comparing the change in the surface strength after strengthening.


2018 ◽  
Vol 29 (5) ◽  
pp. 459-464 ◽  
Author(s):  
Larissa Tais Soligo ◽  
Ediléia Lodi ◽  
Ana Paula Farina ◽  
Matheus Albino Souza ◽  
Cristina de Mattos Pimenta Vidal ◽  
...  

Abstract The aim of this study was to compare the efficacy of grape seed extract (GSE), calcium hypochlorite [Ca(ClO)2], and sodium hypochlorite (NaOCl) irrigant solutions with rotary or reciprocating instrumentation for disinfection of root canals inoculated with Enterococcus faecalis. The mesiobuccal root canals of mandibular molars were prepared and inoculated with Enterococcus faecalis for 21 days. The roots were then randomly divided into the following eight experimental groups (n=11) according to the instrumentation technique and disinfection protocol: ProTaper Next or Reciproc R25 with sodium chloride (control group), 6% NaOCl, 6% Ca(ClO)2, or 50% GSE used for irrigation during instrumentation. The antimicrobial activity was determined on the basis of a reduction in colony-forming units (CFUs) counted on bacterial samples collected before and after root canal instrumentation and expressed as a percentage of reduction. Data were evaluated by two-way ANOVA followed by Tukey HSD post-hoc tests (p<0.05). No significant differences were observed in bacterial reduction between the ProTaper Next and Reciproc R25 systems (p>0.05), regardless of the irrigant solution used. Furthermore, all active solutions (6% NaOCl, 50% GSE, and 6% Ca(ClO)2) showed similar potential to reduce bacterial counts (p>0.05) and were significantly more effective than sodium chloride (control) (p<0.05). The results suggest that the GSE and Ca(ClO)2 have potential clinical application as irrigant solutions in endodontic therapy since they present bactericidal efficacy against Enterococcus faecalis.


Author(s):  
Weibing Teng ◽  
Joseph Cappello ◽  
Xiaoyi Wu

Silk may possess superior mechanical strength while its resilience is very poor. In contrast, elastin in human arteries is very soft but extremely durable with an estimated half-life of 70 years. By combing polypeptide sequences derived from native silk and elastin, we have produced a series of silk-elastin-like proteins (SELPs), which have displayed a set of outstanding properties such as good biocompatibility and controllable biodegradation rates [1]. In this study, we will examine the crystallization of the silk-like blocks and the crosslinking of the elastin-like blocks, as well as their influences on the mechanical behavior of SELPs. The ultimate goal of this study is to explore the potential of SELPs for applications in the engineering of load-bearing tissues such as arteries.


2018 ◽  
Vol 35 (4) ◽  
pp. 441-454 ◽  
Author(s):  
M. Shishesaz ◽  
M. Hosseini

ABSTRACTIn this paper, the mechanical behavior of a functionally graded nano-cylinder under a radial pressure is investigated. Strain gradient theory is used to include the small scale effects in this analysis. The variations in material properties along the thickness direction are included based on three different models. Due to slight variations in engineering materials, the Poisson’s ratio is assumed to be constant. The governing equation and its corresponding boundary conditions are obtained using Hamilton’s principle. Due to the complexity of the governed system of differential equations, numerical methods are employed to achieve a solution. The analysis is general and can be reduced to classical elasticity if the material length scale parameters are taken to be zero. The effect of material indexn, variations in material properties and the applied internal and external pressures on the total and high-order stresses, are well examined. For the cases in which the applied external pressure at the inside (or outside) radius is zero, due to small effects in nano-cylinder, some components of the high-order radial stresses do not vanish at the boundaries. Based on the results, the material inhomogeneity indexn, as well as the selected model through which the mechanical properties may vary along the thickness, have significant effects on the radial and circumferential stresses.


2008 ◽  
Vol 396-398 ◽  
pp. 269-272
Author(s):  
E.S. Antunes ◽  
T. H. S. Sousa ◽  
C.A. Fortulan ◽  
Jonas Carvalho ◽  
B. de M. Purquerio

Non metallic materials like polyurethane has been successfully used for bone reconstruction in general and specifically in craniofacial and in mandible surgeries as an implantable material. However, any polymer alone cannot be universally successful as a medical device or structural implant because the eventual lack of well defined porous geometry, inherent interconnected porosity, the non dispensable need for a combined mechanical behavior with biological interaction and manufacturing feasibility. In this work, a bioactive material composite with high mechanical strength was designed using a castor oil polyurethane (PU) structure with a functional gradient having a dense core and a porous bioactive surface. The models and replicas for the implants were processed with Rapid Prototyping (RP) techniques and their application (case studies) were fulfilled according to the SUS (Brazilian Health Service) with the support of Santa Tereza Hospital, Petropolis, RJ.


Author(s):  
Taesun You ◽  
Yong-Rak Kim ◽  
Taehyo Park

This paper presents a two-way linked computational multiscale model and its application to predict the mechanical behavior of bone subjected to viscoelastic deformation and fracture damage. The model is based on continuum thermos-mechanics and is implemented through the finite element method (FEM). Two physical length scales (the global scale of bone and local scale of compact bone) were two-way coupled in the framework by linking a homogenized global object to heterogeneous local-scale representative volume elements (RVEs). Multiscaling accounts for microstructure heterogeneity, viscoelastic deformation, and rate-dependent fracture damage at the local scale in order to predict the overall behavior of bone by using a viscoelastic cohesive zone model incorporated with a rate-dependent damage evolution law. In particular, age-related changes in material properties and geometries in bone were considered to investigate the effect of aging, loading rate, and damage evolution characteristics on the mechanical behavior of bone. The model successfully demonstrated its capability to predict the viscoelastic response and fracture damage due to different levels of aging, loading conditions (such as rates), and microscale damage evolution characteristics with only material properties of each constituent in the RVEs.


Sign in / Sign up

Export Citation Format

Share Document