scholarly journals White matter dissection with the Klingler technique: a literature review

Author(s):  
Tomasz A. Dziedzic ◽  
Artur Balasa ◽  
Mateusz P. Jeżewski ◽  
Łukasz Michałowski ◽  
Andrzej Marchel

Abstract The aim of this literature review is to present a summary of the published literature relating the details of the different modifications of specimen preparation for white matter dissection with the Klingler technique. For this review, 3 independent investigators performed an electronic literature search that was carried out in the Pubmed, Scopus and Web of Science databses up to December 2019. Furthermore, we performed citation tracking for the articles missed in the initial search. Studies were eligible for inclusion when they reported details of at least the first 2 main steps of Klingler’s technique: fixation and freezing. A total of 37 full-text articles were included in the analysis. We included original anatomical studies in which human white matter dissection was performed for study purposes. The main three steps of preparation are the same in each laboratory, but the details of each vary between studies. Ten percent formalin is the most commonly used (34 studies) solution for fixation. The freezing time varied between 8 h and a month, and the temperature varied from − 5 to − 80 °C. After thawing and during dissections, the specimens were most often kept in formalin solution (13), and the concentration varied from 4 to 10%. Klingler’s preparation technique involves three main steps: fixation, freezing and thawing. Even though the details of the technique are different in most of the studies, all provide subjectively good quality specimens for anatomical dissections and studies.

2020 ◽  
Vol 11 (2) ◽  
pp. 19-22
Author(s):  
E. A. Strel’tsov

This literature review reviews Munchausen syndrome. The question of its nosological affi liation is considered, etiological theories and epidemiological indicators are presented. The options for the development of the clinical picture, the problems of therapy are described. A systematic literature search was conducted using the Scopus, Web of Science, MedLine, elibrary, and other databases.


Author(s):  
M. Talianker ◽  
D.G. Brandon

A new specimen preparation technique for visualizing macromolecules by conventional transmission electron microscopy has been developed. In this technique the biopolymer-molecule is embedded in a thin monocrystalline gold foil. Such embedding can be performed in the following way: the biopolymer is deposited on an epitaxially-grown thin single-crystal gold film. The molecule is then occluded by further epitaxial growth. In such an epitaxial sandwich an occluded molecule is expected to behave as a crystal-lattice defect and give rise to contrast in the electron microscope.The resolution of the method should be limited only by the precision with which the epitaxially grown gold reflects the details of the molecular structure and, in favorable cases, can approach the lattice resolution limit.In order to estimate the strength of the contrast due to the void-effect arising from occlusion of the DNA-molecule in a gold crystal some calculations were performed.


Author(s):  
F. Thoma ◽  
TH. Koller

Under a variety of electron microscope specimen preparation techniques different forms of chromatin appearance can be distinguished: beads-on-a-string, a 100 Å nucleofilament, a 250 Å fiber and a compact 300 to 500 Å fiber.Using a standardized specimen preparation technique we wanted to find out whether there is any relation between these different forms of chromatin or not. We show that with increasing ionic strength a chromatin fiber consisting of a row of nucleo- somes progressively folds up into a solenoid-like structure with a diameter of about 300 Å.For the preparation of chromatin for electron microscopy the avoidance of stretching artifacts during adsorption to the carbon supports is of utmost importance. The samples are fixed with 0.1% glutaraldehyde at 4°C for at least 12 hrs. The material was usually examined between 24 and 48 hrs after the onset of fixation.


Author(s):  
Jayesh Bellare

Seeing is believing, but only after the sample preparation technique has received a systematic study and a full record is made of the treatment the sample gets.For microstructured liquids and suspensions, fast-freeze thermal fixation and cold-stage microscopy is perhaps the least artifact-laden technique. In the double-film specimen preparation technique, a layer of liquid sample is trapped between 100- and 400-mesh polymer (polyimide, PI) coated grids. Blotting against filter paper drains excess liquid and provides a thin specimen, which is fast-frozen by plunging into liquid nitrogen. This frozen sandwich (Fig. 1) is mounted in a cooling holder and viewed in TEM.Though extremely promising for visualization of liquid microstructures, this double-film technique suffers from a) ireproducibility and nonuniformity of sample thickness, b) low yield of imageable grid squares and c) nonuniform spatial distribution of particulates, which results in fewer being imaged.


Author(s):  
S.R. Glanvill

This paper summarizes the application of ultramicrotomy as a specimen preparation technique for some of the Materials Science applications encountered over the past two years. Specimens 20 nm thick by hundreds of μm lateral dimension are readily prepared for electron beam analysis. Materials examined include metals, plastics, ceramics, superconductors, glassy carbons and semiconductors. We have obtain chemical and structural information from these materials using HRTEM, CBED, EDX and EELS analysis. This technique has enabled cross-sectional analysis of surfaces and interfaces of engineering materials and solid state electronic devices, as well as interdiffusion studies across adjacent layers.Samples are embedded in flat embedding moulds with Epon 812 epoxy resin / Methyl Nadic Anhydride mixture, using DY064 accelerator to promote the reaction. The embedded material is vacuum processed to remove trapped air bubbles, thereby improving the strength and sectioning qualities of the cured block. The resin mixture is cured at 60 °C for a period of 80 hr and left to equilibrate at room temperature.


Author(s):  
R.T. Blackham ◽  
J.J. Haugh ◽  
C.W. Hughes ◽  
M.G. Burke

Essential to the characterization of materials using analytical electron microscopy (AEM) techniques is the specimen itself. Without suitable samples, detailed microstructural analysis is not possible. Ultramicrotomy, or diamond knife sectioning, is a well-known mechanical specimen preparation technique which has been gaining attention in the materials science area. Malis and co-workers and Glanvill have demonstrated the usefulness and applicability of this technique to the study of a wide variety of materials including Al alloys, composites, and semiconductors. Ultramicrotomed specimens have uniform thickness with relatively large electron-transparent areas which are suitable for AEM anaysis.Interface Analysis in Type 316 Austenitic Stainless Steel: STEM-EDS microanalysis of grain boundaries in austenitic stainless steels provides important information concerning the development of Cr-depleted zones which accompany M23C6 precipitation, and documentation of radiation induced segregation (RIS). Conventional methods of TEM sample preparation are suitable for the evaluation of thermally induced segregation, but neutron irradiated samples present a variety of problems in both the preparation and in the AEM analysis, in addition to the handling hazard.


1986 ◽  
Vol 47 (C7) ◽  
pp. C7-459-C7-462 ◽  
Author(s):  
M. G. BURKE ◽  
D. D. SIELOFF ◽  
S. S. BRENNER

Author(s):  
Muhammad Yousaf ◽  
Petr Bris

A systematic literature review (SLR) from 1991 to 2019 is carried out about EFQM (European Foundation for Quality Management) excellence model in this paper. The aim of the paper is to present state of the art in quantitative research on the EFQM excellence model that will guide future research lines in this field. The articles were searched with the help of six strings and these six strings were executed in three popular databases i.e. Scopus, Web of Science, and Science Direct. Around 584 peer-reviewed articles examined, which are directly linked with the subject of quantitative research on the EFQM excellence model. About 108 papers were chosen finally, then the purpose, data collection, conclusion, contributions, and type of quantitative of the selected papers are discussed and analyzed briefly in this study. Thus, this study identifies the focus areas of the researchers and knowledge gaps in empirical quantitative literature on the EFQM excellence model. This article also presents the lines of future research.


Author(s):  
K. Doong ◽  
J.-M. Fu ◽  
Y.-C. Huang

Abstract The specimen preparation technique using focused ion beam (FIB) to generate cross-sectional transmission electron microscopy (XTEM) samples of chemical vapor deposition (CVD) of Tungsten-plug (W-plug) and Tungsten Silicides (WSix) was studied. Using the combination method including two axes tilting[l], gas enhanced focused ion beam milling[2] and sacrificial metal coating on both sides of electron transmission membrane[3], it was possible to prepare a sample with minimal thickness (less than 1000 A) to get high spatial resolution in TEM observation. Based on this novel thinning technique, some applications such as XTEM observation of W-plug with different aspect ratio (I - 6), and the grain structure of CVD W-plug and CVD WSix were done. Also the problems and artifacts of XTEM sample preparation of high Z-factor material such as CVD W-plug and CVD WSix were given and the ways to avoid or minimize them were suggested.


Author(s):  
Daisy Vyas Shirk ◽  
Sarah D. Williams

Background: Ehlers-Danlos Syndromes (EDS) comprise a group of heterogeneous hereditary connective tissue disorders [1, 2]. Psychiatric disorders such as depression, anxiety, panic disorder, agoraphobia, schizophrenia, neurodevelopmental disorders, personality disorder, eating disorders, substance misuse and interpersonal issues have been reported in the literature to be associated with EDS [1-3]. Objectives: The case of a 15-year -old male who was hospitalized after a suicide attempt by gunshot was discovered to have symptoms suggestive of EDS is presented in this paper along with the results of a literature search of psychiatric manifestations of EDS in children and adolescents. Methods: Literature review was conducted on the UpToDate website on March 11, 2020 to review symptoms of EhlersDanlos Syndrome for the purpose of preliminary diagnosis of this patient. Additional literature search was conducted on PubMed on 4/2/20 at 12:10 P.M. and on 4/9/20 at 10:51 P.M. and on the search engine Google on 4/2/20 at 12:25 P.M. On May 11, 2020 at 2 P.M., another web search was conducted with review of 6 different websites pertaining to EhlersDanlos Syndrome. Results: A systematic review of psychiatric manifestations of Ehlers-Danlos Syndromes revealed a strong incidence of psychiatric symptoms. Conclusion: Our patient’s psychiatric symptoms of depression, suicidal ideations, anxiety and social and educational struggles may have been at least partially due to chronic pain- abdominal, headache and musculoskeletal, and social ostracization associated with Ehlers-Danlos Syndrome. Education regarding this illness helped our patient’s recovery as he came to understand why he was so “odd” and the cause of his multisystemic chronic pain.


Sign in / Sign up

Export Citation Format

Share Document