scholarly journals Forest restoration monitoring through digital processing of high resolution images

2019 ◽  
Vol 127 ◽  
pp. 178-186 ◽  
Author(s):  
Bruna Paolinelli Reis ◽  
Sebastião Venâncio Martins ◽  
Elpídio Inácio Fernandes Filho ◽  
Tathiane Santi Sarcinelli ◽  
José Marinaldo Gleriani ◽  
...  
2021 ◽  
pp. 1-21
Author(s):  
Sergio Ripoll ◽  
Vicente Bayarri ◽  
Francisco J. Muñoz ◽  
Ricardo Ortega ◽  
Elena Castillo ◽  
...  

Our Palaeolithic ancestors did not make good representations of themselves on the rocky surfaces of caves and barring certain exceptions – such as the case of La Marche (found on small slabs of stone or plaquettes) or the Cueva de Ambrosio – the few known examples can only be referred to as anthropomorphs. As such, only hand stencils give us a real picture of the people who came before us. Hand stencils and imprints provide us with a large amount of information that allows us to approach not only their physical appearance but also to infer less tangible details, such as the preferential use of one hand over the other (i.e., handedness). Both new and/or mature technologies as well as digital processing of images, computers with the ability to process very high resolution images, and a more extensive knowledge of the Palaeolithic figures all help us to analyse thoroughly the hands in El Castillo cave. The interdisciplinary study presented here contributes many novel developments based on real data, representing a major step forward in knowledge about our predecessors.


2014 ◽  
Vol 600 ◽  
pp. 10-14
Author(s):  
Edgar Torres ◽  
Arturo Plata ◽  
Germán Díaz ◽  
Caori Takeuchi

The fiber density per cross section of the Bamboo Guadua Angustifolia Kunth (GAK) was calculated by digital images processing. Three processes were done in the development of this work: preparation of the samples, digital pre-processing of the images acquired, and digital processing of the images acquired. For the preparation of the samples, the polishing with different abrasive papers and wool were done, and afterwards, it was added revealing ink on surface to make better the contrast between the fiber zones. The digital pre-processing of the images was based on the acquisition of sequences of images, doing a sweeping of the samples using an automatic plate. The digital processing consisted in the generation of panoramas with sequences of images acquired from the sample. The cross section fiber density was obtained by the calculus of the reason between digital measurement of the total area of the fibers and the total area of the sample. Finally, the values obtained for the fiber density were: 0.34, 0.41 and 0.43 for bottom, middle and top part of the culm respectively.


2021 ◽  
Vol 13 (8) ◽  
pp. 1446
Author(s):  
Inggit Lolita Sari ◽  
Christopher J. Weston ◽  
Glenn J. Newnham ◽  
Liubov Volkova

This study assessed the accuracy of land cover change (2000–2018) maps compiled from Landsat images with either automated digital processing or with visual interpretation for a tropical forest area in Indonesia. The accuracy assessment used a two-stage stratified random sampling involving a confusion matrix for assessing map accuracy and by estimating areas of land cover change classes and associated uncertainty. The reference data were high-resolution images from SPOT 6/7 and high-resolution images finer than 5 m obtained from Open Foris Collect Earth. Results showed that the map derived from automated digital processing had lower accuracy (overall accuracy 73–77%) compared to the map based on visual interpretation (overall accuracy 80–84%). The automated digital processing map error was in differentiating between native forest and plantation areas. While the visual interpretation map had a higher accuracy, it did not consistently differentiate between native forest and shrub areas. Future improvement of the digital map requires more accurate differentiation between forest and plantation to better support national forest monitoring systems for sustainable forest management.


1994 ◽  
Vol 144 ◽  
pp. 541-547
Author(s):  
J. Sýkora ◽  
J. Rybák ◽  
P. Ambrož

AbstractHigh resolution images, obtained during July 11, 1991 total solar eclipse, allowed us to estimate the degree of solar corona polarization in the light of FeXIV 530.3 nm emission line and in the white light, as well. Very preliminary analysis reveals remarkable differences in the degree of polarization for both sets of data, particularly as for level of polarization and its distribution around the Sun’s limb.


Author(s):  
Etienne de Harven

Biological ultrastructures have been extensively studied with the scanning electron microscope (SEM) for the past 12 years mainly because this instrument offers accurate and reproducible high resolution images of cell shapes, provided the cells are dried in ways which will spare them the damage which would be caused by air drying. This can be achieved by several techniques among which the critical point drying technique of T. Anderson has been, by far, the most reproducibly successful. Many biologists, however, have been interpreting SEM micrographs in terms of an exclusive secondary electron imaging (SEI) process in which the resolution is primarily limited by the spot size of the primary incident beam. in fact, this is not the case since it appears that high resolution, even on uncoated samples, is probably compromised by the emission of secondary electrons of much more complex origin.When an incident primary electron beam interacts with the surface of most biological samples, a large percentage of the electrons penetrate below the surface of the exposed cells.


Author(s):  
S. Saito ◽  
H. Todokoro ◽  
S. Nomura ◽  
T. Komoda

Field emission scanning electron microscope (FESEM) features extremely high resolution images, and offers many valuable information. But, for a specimen which gives low contrast images, lateral stripes appear in images. These stripes are resulted from signal fluctuations caused by probe current noises. In order to obtain good images without stripes, the fluctuations should be less than 1%, especially for low contrast images. For this purpose, the authors realized a noise compensator, and applied this to the FESEM.Fig. 1 shows an outline of FESEM equipped with a noise compensator. Two apertures are provided gust under the field emission gun.


Author(s):  
David C. Joy ◽  
Dennis M. Maher

High-resolution images of the surface topography of solid specimens can be obtained using the low-loss technique of Wells. If the specimen is placed inside a lens of the condenser/objective type, then it has been shown that the lens itself can be used to collect and filter the low-loss electrons. Since the probeforming lenses in TEM instruments fitted with scanning attachments are of this type, low-loss imaging should be possible.High-resolution, low-loss images have been obtained in a JEOL JEM 100B fitted with a scanning attachment and a thermal, fieldemission gun. No modifications were made to the instrument, but a wedge-shaped, specimen holder was made to fit the side-entry, goniometer stage. Thus the specimen is oriented initially at a glancing angle of about 30° to the beam direction. The instrument is set up in the conventional manner for STEM operation with all the lenses, including the projector, excited.


Author(s):  
M. Kelly ◽  
D.M. Bird

It is well known that strain fields can have a strong influence on the details of HREM images. This, for example, can cause problems in the analysis of edge-on interfaces between lattice mismatched materials. An interesting alternative to conventional HREM imaging has recently been advanced by Pennycook and co-workers where the intensity variation in the annular dark field (ADF) detector is monitored as a STEM probe is scanned across the specimen. It is believed that the observed atomic-resolution contrast is correlated with the intensity of the STEM probe at the atomic sites and the way in which this varies as the probe moves from cell to cell. As well as providing a directly interpretable high-resolution image, there are reasons for believing that ADF-STEM images may be less suseptible to strain than conventional HREM. This is because HREM images arise from the interference of several diffracted beams, each of which is governed by all the excited Bloch waves in the crystal.


Author(s):  
Kenneth H. Downing ◽  
Hu Meisheng ◽  
Hans-Rudolf Went ◽  
Michael A. O'Keefe

With current advances in electron microscope design, high resolution electron microscopy has become routine, and point resolutions of better than 2Å have been obtained in images of many inorganic crystals. Although this resolution is sufficient to resolve interatomic spacings, interpretation generally requires comparison of experimental images with calculations. Since the images are two-dimensional representations of projections of the full three-dimensional structure, information is invariably lost in the overlapping images of atoms at various heights. The technique of electron crystallography, in which information from several views of a crystal is combined, has been developed to obtain three-dimensional information on proteins. The resolution in images of proteins is severely limited by effects of radiation damage. In principle, atomic-resolution, 3D reconstructions should be obtainable from specimens that are resistant to damage. The most serious problem would appear to be in obtaining high-resolution images from areas that are thin enough that dynamical scattering effects can be ignored.


Author(s):  
A. V. Crewe ◽  
M. Ohtsuki

We have assembled an image processing system for use with our high resolution STEM for the particular purpose of working with low dose images of biological specimens. The system is quite flexible, however, and can be used for a wide variety of images.The original images are stored on magnetic tape at the microscope using the digitized signals from the detectors. For low dose imaging, these are “first scan” exposures using an automatic montage system. One Nova minicomputer and one tape drive are dedicated to this task.The principal component of the image analysis system is a Lexidata 3400 frame store memory. This memory is arranged in a 640 x 512 x 16 bit configuration. Images are displayed simultaneously on two high resolution monitors, one color and one black and white. Interaction with the memory is obtained using a Nova 4 (32K) computer and a trackball and switch unit provided by Lexidata.The language used is BASIC and uses a variety of assembly language Calls, some provided by Lexidata, but the majority written by students (D. Kopf and N. Townes).


Sign in / Sign up

Export Citation Format

Share Document