Micro-CT imaging of rat lung ventilation using continuous image acquisition during xenon gas contrast enhancement

2007 ◽  
Vol 103 (5) ◽  
pp. 1848-1856 ◽  
Author(s):  
Wilfred W. Lam ◽  
David W. Holdsworth ◽  
Louise Y. Du ◽  
Maria Drangova ◽  
David G. McCormack ◽  
...  

We measured ventilation (V̇) in seven anesthetized, mechanically ventilated, supine Wistar rats. Images of the whole lung were continuously acquired using a dynamic, flat-panel volumetric micro-computed tomography (micro-CT) scanner during ventilation with a xenon/oxygen (Xe-O2) gas mixture. Forty time-resolved volumes consisting of eighty 0.45-mm-thick slices (covering the entire lung) were acquired in 40 s, using a gantry rotation rate of one rotation per second. The animals were ventilated at a respiratory rate of 60 breaths/min, matching the gantry rotation rate, and imaged without suspending ventilation. A previously published theoretical model was modified slightly and used to calculate the whole lung ventilation from volumes of interest generated by seeded region growing. Linear regression of calculated whole lung ventilation volumes vs. expected tidal volumes yielded a slope of 1.12 ± 0.11 (slope ± SE) and a y-intercept of −1.56 ± 0.42 ml ( y-intercept ± SE) with 95% confidence intervals of 0.83 to 1.40 and −2.6 to −0.5 ml, respectively. The same model was used to calculate the regional ventilation in axial slices for each animal. Voxels were fit to the model to yield a map of V̇, which displayed an anterior/posterior gravitational gradient of (−3.9 ± 1.8) × 10−6 ml·s−1·cm−1 for slices immediately superior to the diaphragm and (−6.0 ± 2.4) × 10−6 ml·s−1·cm−1 for slices at the midlevel of the heart (mean ± SD). Thus continuous Xe-enhanced computed tomography enables the noninvasive determination of regional V̇ with the temporal and spatial resolution necessary for rats.

Author(s):  
Mohammadreza Fouladi ◽  
Kamran Gholami ◽  
Hossein Ghadiri

X-ray Computed Tomography (CT), e.g. clinical CT scanners, basically provides Linear Attenuation Coefficients (LACs) of objects under study by the means of algorithmic reconstruction of acquired views of attenuated X-ray passing through the samples in different angles around the imaged sample. Micro Computed Tomography (micro-CT) basically works the same as clinical CT. It provides volumetric information representing the inner structure of objects with a resolution in the micron range. LOTUS-inVivo is a micro-CT scanner dedicated to imaging of small animals and ex-vivo biological samples. In the present study the spatial resolution and Low Contrast Detectability (LCD) of LOTUS-inVivo scanner were evaluated using standard phantoms. We aimed to prove the capability of LOTUS-inVivo for small animal and ex-vivo biological samples imaging using the measured image quality parameters, i.e. spatial resolution and low contrast detectability. By the means of analysis of bar and LCD phantom images, the limiting resolution of LOTUS-inVivo micro-CT scanner was measured about 2.7 µm and has been shown that it’s capable of resolving sizes greater than 12.5 µm. Also, we concluded that LOTUS-inVivo is capable of discriminating tissues with 3% differences in contrast relative to the background, for 1 mm bar size. Thus, the provided technical characteristics in this study have made LOTUS-inVivo as a suitable tool for small animal imaging.


2021 ◽  
Vol 11 (3) ◽  
pp. 891
Author(s):  
Taylor Flaherty ◽  
Maryam Tamaddon ◽  
Chaozong Liu

Osteochondral scaffold technology has emerged as a promising therapy for repairing osteochondral defects. Recent research suggests that seeding osteochondral scaffolds with bone marrow concentrate (BMC) may enhance tissue regeneration. To examine this hypothesis, this study examined subchondral bone regeneration in scaffolds with and without BMC. Ovine stifle condyle models were used for the in vivo study. Two scaffold systems (8 mm diameter and 10 mm thick) with and without BMC were implanted into the femoral condyle, and the tissues were retrieved after six months. The retrieved femoral condyles (with scaffold in) were examined using micro-computed tomography scans (micro-CT), and the micro-CT data were further analysed by ImageJ with respect to trabecular thickness, bone volume to total volume ratio (BV/TV) ratio, and degree of anisotropy of bone. Statistical analysis compared bone regeneration between scaffold groups and sub-set regions. These results were mostly insignificant (p < 0.05), with the exception of bone volume to total volume ratio when comparing scaffold composition and sub-set region. Additional trends in the data were observed. These results suggest that the scaffold composition and addition of BMC did not significantly affect bone regeneration in osteochondral defects after six months. However, this research provides data which may guide the development of future treatments.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Javier Alba-Tercedor ◽  
Wayne B. Hunter ◽  
Ignacio Alba-Alejandre

AbstractThe Asian citrus psyllid (ACP), Diaphorina citri, is a harmful pest of citrus trees that transmits Candidatus Liberibacter spp. which causes Huanglongbing (HLB) (citrus greening disease); this is considered to be the most serious bacterial disease of citrus plants. Here we detail an anatomical study of the external and internal anatomy (excluding the reproductive system) using micro-computed tomography (micro-CT). This is the first complete 3D micro-CT reconstruction of the anatomy of a psylloid insect and includes a 3D reconstruction of an adult feeding on a citrus leaf that can be used on mobile devices. Detailed rendered images and videos support first descriptions of coxal and scapus antennal glands and sexual differences in the internal anatomy (hindgut rectum, mesothoracic ganglion and brain). This represents a significant advance in our knowledge of ACP anatomy, and of psyllids in general. Together the images, videos and 3D model constitute a unique anatomical atlas and are useful tools for future research and as teaching aids.


2021 ◽  
Author(s):  
Eva Chatzinikolaou ◽  
Kleoniki Keklikoglou

Micro-computed tomography (micro-CT) is a high-resolution 3D-imaging technique which is now increasingly applied in biological studies focusing on taxonomy and functional morphology. The creation of virtual representations of specimens can increase availability of otherwise underexploited and inaccessible samples. This protocol aims to standardise micro-CT scanning procedures for embryos and juveniles of the marine gastropod species Hexaplex trunculus.


2019 ◽  
Vol 25 ◽  
pp. 6351-6358
Author(s):  
Gabrielė Česaitienė ◽  
Tadas Venskutonis ◽  
Vita Mačiulskienė ◽  
Vaidotas Cicėnas ◽  
Vykintas Samaitis ◽  
...  

2021 ◽  
pp. 002199832110338
Author(s):  
Elisson BD da Rocha ◽  
Ana Maria F de Sousa ◽  
Ana Lúcia N da Silva ◽  
Cristina RG Furtado ◽  
Marcos V Colaço ◽  
...  

This study reports the reinforcement degree investigation of two types of rockwool fibers (F1 and F2), in nitrile rubber composites. The micro-computed tomography (micro-CT) 3D images showed that both fibers were well-dispersed in the NBR matrix, without a preferential orientation. The micro-CT analysis also allowed quantifying volume fraction, inter-fiber distance, and aspect ratio. Those morphometric parameters were used for supporting the composites rheological behavior assessment. Changes in the elastic modulus and phase angle followed the same trend of the inter-fiber distance values, regardless the type of fiber. Both volume fraction and aspect ratio data from the micro-CT analysis were used to predict theoretical values of elastic modulus using the Guth-Gold and modified Guth-Gold equations, and the results obtained were compared to the rheological experimental data. This analysis was helpful to better understand the rockwool fibers reinforcement degree differences in the production of the nitrile rubber composites.


Author(s):  
Timothy Holland

ABSTRACTMicro computed tomography has revealed as yet undescribed internal braincase anatomy of the tetrapodomorph fish Gogonasus andrewsae from the Frasnian Gogo Formation, Paddy's Valley, Kimberley Region, Western Australia. The complete material, including the cranial cavities and channels for blood vessels and nerves, reveals several notable features inside the endocranium. The ethmosphenoid unit includes a median capsule, which lies underneath the median postrostral and rostral series. Based on innervation and association with cutaneous vessels, potential electroreceptive function is inferred for this capsule. Several regions of poor ossification, including foramina for the glossopharyngeal and abducens nerves, as well as the apparent suture separating the ethmoid from the sphenoid portions of the braincase, are possibly indicative of early ontogenetic features. Former interpretations of the course for the superficial ophthalmic nerve inside the nasal capsule of Osteolepis and Gyroptychius may be incorrect, with new research supporting a path through the nasal septum, as in Gogonasus.


2018 ◽  
Vol 21 (3) ◽  
pp. 282
Author(s):  
Amanda Sousa Vidal ◽  
Daniele Aparecida Leão ◽  
Fernanda Mota Guimarães ◽  
Mariana Oliveira Gonçalves ◽  
Raissa Freitas Pinheiro ◽  
...  

<p><strong>Objective: </strong>The aim of this study was to use Micro computed tomography (micro-CT) to evaluate the influence of the type of vehicle associated with calcium hydroxide on its ability to penetrate simulated lateral canals. <strong>Materials and methods:</strong> 30 acrylic blocks with simulated lateral canals comprising apical, middle and cervical thirds were used in the <em>in vitro</em> study. The blocks were divided into 3 groups (n = 10) according to the type of vehicle used (chlorhexidine, distilled water and propylene glycol) in the calcium hydroxide slurry, which was inserted in the respective group of simulated canals with a K# 30 file and then agitated with an ultrasonic tip. The blocks were scanned by micro-computed tomography (micro-CT) before and after insertion of the medication. The images obtained were reconstructed and analyzed to obtain the initial volume of lateral canals and the volume of medication that penetrated into them. <strong>Results:</strong> In the intragroup analysis, both distilled water and chlorhexidine 2% were observed to present statistical difference in all thirds of the canal. Propylene glycol showed no intragroup difference. In the inter-group analysis, the propylene glycol paste presented higher values of penetration into the simulated lateral canals than the other groups (p &lt;0.05). <strong>Conclusion:</strong> Propylene glycol used as vehicle of the calcium hydroxide paste provided better penetration results in simulated lateral canals.</p>


Sign in / Sign up

Export Citation Format

Share Document