scholarly journals Mechanical properties of materials used for temporary fixed dentures – in vitro study

2017 ◽  
Vol 30 (2) ◽  
pp. 61-64
Author(s):  
Elzbieta Celej-Piszcz ◽  
Leszek Szalewski ◽  
Przemyslaw Kleinrok ◽  
Janusz Borowicz

Abstract Objectives. The objective of the research was to define the mechanical properties of currently marketed temporary filling materials. Methods. Eight temporary filling materials: Boston, Dentalon, Protemp II, Revotek LC, Structure 2, Structure 3, UniFast LC, UniFast Trad were used to make 5 samples each of measurements 2 × 2 × 25 mm, in order to define the flexural strength, and 10 rings each of measurements 2 × 5 mm, in order to carry out the Vickers micro-hardness test. After preparation, the samples were stored in distilled water of temperature of 370°C, for 7 days. Subsequently, flexural strength and Vickers hardness testing was undertaken. Results. Composite temporary materials showed considerably better mechanical properties, both in flexural strength and in Vickers micro-hardness testing. Conclusions. the best mechanical properties, both in terms of flexural strength, as well as Vickers micro-hardness test can be observe among composite materials.

2016 ◽  
Vol 1 (2) ◽  
pp. 56-59
Author(s):  
Natanasabapathy Velmurugan ◽  
Poornima Reddy ◽  
Suma Balla ◽  
Sandhya S Raghu ◽  
Garlapati T Gupta ◽  
...  

ABSTRACT Introduction The aim of this study was to compare in vitro the effect of 5% calcium hypochlorite [Ca(OCl)2] and 5% sodium hypochlorite (NaOCl) on flexural strength and modulus of elasticity of root dentin. Materials and methods The available chlorine concentration of each solution was determined using iodometric titration. Standardized planoparallel dentin bars (n= 20) were divided into two test groups and one control group. The control, group 1, consisted of dentin bars stored in normal saline. The dentin bars in the two test groups were treated by exposure to following solutions: Group 2 to 5% Ca(OCl)2; and group 3 to 5% NaOCl. All the three test solutions were changed once in 15 minutes for 30 minutes. The dentin bars were then loaded to failure using three-point bend test. Results Available chlorine concentration was 64% in both the test solutions. There was a significant reduction in the flexural strength of 5% NaOCl group compared to 5% Ca(OCl)2-treated ones. A significant difference in modulus of elasticity was observed between the test groups and the control groups and also between the 5% Ca(OCl)2 and 5% NaOCl groups. Conclusion Within the limitations of this study, 5% NaOCl reduced the flexural strength and modulus of elasticity of root dentin bars more when compared to 5% Ca(OCl)2. How to cite this article Reddy P, Balla S, Raghu SS, Velmurugan N, Gupta GT, Sahoo HS. Effect of 5% Calcium Hypochlorite on Mechanical Properties of Root Dentin: An in vitro Study. J Oper Dent Endod 2016;1(2):56-59.


2007 ◽  
Vol 21 (1) ◽  
pp. 16-21 ◽  
Author(s):  
Sinval Adalberto Rodrigues Junior ◽  
Cesar Henrique Zanchi ◽  
Rodrigo Varella de Carvalho ◽  
Flávio Fernando Demarco

The aim of the study was to test whether the filler composition of resin composites influences their flexural strength and modulus of elasticity. Flexural strength and modulus of elasticity were obtained through a three-point bending test. Twelve bar shaped specimens of 5 commercially available composites - Supreme (3M/ESPE), a universal nanofilled composite; Esthet-X (Dentsply), Z-250 (3M/ESPE), Charisma (Heraeus Kulzer), universal hybrid composites; and Helio Fill (Vigodent), a microfine composite - were confectioned according to the ISO 4049/2000 specifications. The test was performed after a 7-days storage time using a universal test machine with a crosshead speed of 1 mm/min. The filler weight content was determined by the ashing technique. The data obtained on the mechanical properties were submitted to ANOVA and Tukey test (p < 0.05). Pearson's correlation test was used to determine the correlation between the filler content and the mechanical properties. A weak but significant correlation between the mechanical properties evaluated and the filler weight content was observed (p < 0.000). The microfine composite presented the lowest filler weight and the lowest mechanical properties. Statistically different flexural strength and modulus of elasticity results were observed among the universal hybrid composites. The nanofilled composite presented intermediary results. Within the limitations of this in vitro study, it could be concluded that the filler content significantly interfered in the flexural strength and modulus of elasticity of the composites tested.


2020 ◽  
Vol 1 (1) ◽  
pp. 25-29
Author(s):  
Muhamad Anas Munawwar Ghazali ◽  
Mohd Azhar Harimon ◽  
Mohammad Sukri Mustapa

Mo-TZM alloy is one of the most famous economic molybdenum-based alloys. The percentage of chemical composition in mass of Mo-TZM alloy are Mo-0.5Ti-0.08Zr-0.03C. By adding some Titanium and Zirconium so that the mechanical properties and recrystallization temperature of molybdenum has been corresponding improvement. The purpose of this study is to determine the effect of different annealing temperature on mechanical properties of Mo-TZM alloy. The samples will be heated at two different temperature which are 1000 oC and 1300 oC in 1 hour and 40 minutes to change their microstructure behavior. The mechanical properties of the sample like hardness will be analyzed by using Vickers Micro hardness test. The force applied is 4.903 N and Vickers micro hardness number is 0.5 HVN for 10 second. Then to observe the microstructure changes, optical microscope and Scanning Electron Microscope (SEM) is be used. At annealing temperature 1000 oC, it show values of hardness is 249.54 VHN and the grain boundary size is 0.0898mm. While at annealing temperature 1300 oC, it show the lowest values of hardness which is 243.55 VHN and the highest grain boundary size which is 0.1068 mm. By doing annealing heat treatment it will decreases hardness values and increases the size of grain boundary


2013 ◽  
Vol 1 (4) ◽  
pp. 316
Author(s):  
Karin Faust Souza ◽  
Carla Miranda ◽  
Izabel Cristina Santos Almeida

The purpose of this study was to evaluate in vitro the effect of APF, gel and foam, for 1 to 4 minutes, on artificial enamel caries-like lesion of primary teeth submitted to the pH cycling. The specimens with medium values of initial superficial enamel micro-hardness between 272 and 331KHN were selected for the formation of the artificial caries lesion. Later, they were randomly divided into 6 groups (n=15): no pH cycling control, cycled control, gel 1min, gel 4min, foam 1min and foam 4min.The no pH cycling control group was maintained in an humid environment, while the application of APF and the pH cycling were accomplished. After, the specimens were sectioned at the center for the enamel cross-sectional micro-hardness test. The values of micro-hardness of the depths from 20 to 180mm were converted into percentile of mineral volume (%Vol) and the area of mineral recovery (∆ZR) was calculated.  In spite of there is no statistically significant differences, it was observed through the analysis of the ∆ZR a difference in the values for the groups gel 1min and foam 4min (p>0.05). The evaluation of %Vol indicated a significant difference only at 60mm depth (p=0.005). This study concluded that a single application of APF gel or foam, for 1 or 4 minutes, do not remineralize artificial enamel caries-like lesion of primary teeth


1998 ◽  
Author(s):  
R. Berriche ◽  
R.K. Lowry ◽  
M.I. Rosenfield

Abstract The present work investigated the use of the Vickers micro-hardness test method to determine the resistance of individual die to cracking. The results are used as an indicator of resistance to failure under the thermal and mechanical stresses of packaging and subsequent thermal cycling. Indentation measurements on die back surfaces are used to determine how changes in wafer backside processing conditions affect cracks that form around impressions produced at different loads. Test methodology and results obtained at different processing conditions are discussed.


2014 ◽  
Vol 606 ◽  
pp. 253-256 ◽  
Author(s):  
Martin Ovsik ◽  
Petr Kratky ◽  
David Manas ◽  
Miroslav Manas ◽  
Michal Stanek ◽  
...  

This article deals with the influence of different doses of Beta radiation to the structure and mico-mechanical properties of Low-density polyethylene (LDPE). Hard surface layers of polymer materials, especially LDPE, can be formed by radiation cross-linking by β radiation with doses of 33, 66 and 99 kGy. Material properties created by β radiation are measured by micro-hardness test using the DSI method (Depth Sensing Indentation). Individual radiation doses caused structural and micro-mechanical changes which have a significant effect on the final properties of the LDPE tested. The highest values of micro-mechanical properties were reached at radiation dose of 66 and 99 kGy, when the micro-hardness values increased by about 21%. The changes were examined and confirmed by X-ray diffraction.


Materials ◽  
2021 ◽  
Vol 14 (11) ◽  
pp. 2769
Author(s):  
Jonne Oja ◽  
Lippo Lassila ◽  
Pekka K. Vallittu ◽  
Sufyan Garoushi

The aim of current in vitro research was to determine the effect of hydrothermal accelerated aging on the mechanical properties and wear of different commercial dental resin composites (RCs). In addition, the effect of expiration date of the composite prior its use was also evaluated. Five commercially available RCs were studied: Conventional RCs (Filtek Supreme XTE, G-aenial Posterior, Denfil, and >3y expired Supreme XTE), bulk-fill RC (Filtek Bulk Fill), and short fiber-reinforced RC (everX Posterior). Three-point flexural test was used for determination of ultimate flexural strength (n = 8). A vickers indenter was used for testing surface microhardness. A wear test was conducted with 15,000 chewing cycles using a dual-axis chewing simulator. Wear pattern was analyzed by a three-dimensional (3D) noncontact optical profilometer. Degree of C=C bond conversion of monomers was determined by FTIR-spectrometry. The specimens were either dry stored for 48 h (37 °C) or boiled (100 °C) for 16 h before testing. Scanning electron microscopy (SEM) was used to evaluate the microstructure of each material. Data were analyzed using ANOVA (p = 0.05). Hydrothermal aging had no significant effects on the surface wear and microhardness of tested RCs (p > 0.05). While flexural strength significantly decreased after aging (p < 0.05), except for G-aenial Posterior, which showed no differences. The lowest average wear depth was found for Filtek Bulk Fill (29 µm) (p < 0.05), while everX Posterior and Denfil showed the highest wear depth values (40, 39 µm) in both conditions. Passing the expiration date for 40 months did not affect the flexural strength and wear of tested RC. SEM demonstrated a significant number of small pits on Denfil’s surface after aging. It was concluded that the effect of accelerated aging may have caused certain weakening of the RC of some brands, whereas no effect was found with one brand of RC. Thus, the accelerated aging appeared to be more dependent on material and tested material property.


2014 ◽  
Vol 60 (5) ◽  
pp. 200-203
Author(s):  
Andreea Borş ◽  
Cristina Molnar-Varlam ◽  
Melinda Székely

Abstract Objective: The aim of this in vitro study was to evaluate the influence of erosive conditions on the wear resistance of aesthetic direct restorative materials. Methods: Six dental filling materials were tested: two composites (Filtek Z550 and X-tra fil), two compomers (Dyract Extra and Twinky Star) and two glass ionomers (Ketac Molar and Fuji II LC). Twenty disks (10mm×2mm) of each material were prepared (n=120) and kept in artificial saliva at 37˚C for 24 hours. Specimens were cycled in acidic soft drink (Coca-Cola) 5×/day, for 5’, over 30 days. Initial surface roughness ISR (Ra-μm) and final surface roughness FSR were measured using a profilometer. The wear rate was calculated as difference of final minus the initial roughness (ΔSR=FSR-ISR). For statistical analysis t-test and one-way ANOVA test were used by GraphPad Prism version 5.03 statistical software. The level of significance was set at p<0.05. Results: The erosive wear rates (mean±SD, μm) after exposure to acidic beverage were: 0.30±0.03 (Ketac Molar), 0.28±0.04 (Fuji II LC), 0.27±0.00 (Filtek Z550), 0.23±0.01 (X-tra fil), 0.20±0.00 (Twinky Star) and 0.14±0.01 Dyract Extra, respectively. There were significant differences between the tested materials (p<0.05). Conclusions: Dental filling materials had different behaviour under the same erosive condition, however all investigated aesthetic restorative materials showed surface degradation. These findings suggest that erosive wear resistance of tooth coloured restoratives could influence their longevity in intraoral acidic conditions. Acknowledgements: The study was supported by the Internal Research Grant no. 5/30.01.2013 of the University of Medicine and Pharmacy of Tirgu Mureş.