Electrical Characterization of Tungsten Nanowires Deposited by Focused Ion Beam (FIB)

Nanopages ◽  
2006 ◽  
Vol 1 (2) ◽  
pp. 255-262 ◽  
Author(s):  
E. Horváth ◽  
P. L. Neumann ◽  
A. L. Tóth ◽  
É. Vázsonyi ◽  
A. A. Koós ◽  
...  
Author(s):  
E. Hendarto ◽  
S.L. Toh ◽  
J. Sudijono ◽  
P.K. Tan ◽  
H. Tan ◽  
...  

Abstract The scanning electron microscope (SEM) based nanoprobing technique has established itself as an indispensable failure analysis (FA) technique as technology nodes continue to shrink according to Moore's Law. Although it has its share of disadvantages, SEM-based nanoprobing is often preferred because of its advantages over other FA techniques such as focused ion beam in fault isolation. This paper presents the effectiveness of the nanoprobing technique in isolating nanoscale defects in three different cases in sub-100 nm devices: soft-fail defect caused by asymmetrical nickel silicide (NiSi) formation, hard-fail defect caused by abnormal NiSi formation leading to contact-poly short, and isolation of resistive contact in a large electrical test structure. Results suggest that the SEM based nanoprobing technique is particularly useful in identifying causes of soft-fails and plays a very important role in investigating the cause of hard-fails and improving device yield.


2003 ◽  
Vol 16 (2) ◽  
pp. 199-206 ◽  
Author(s):  
S. Smith ◽  
A.J. Walton ◽  
S. Bond ◽  
A.W.S. Ross ◽  
J. Tom ◽  
...  

Author(s):  
Werner Lehner ◽  
Siegfried Pauthner ◽  
Herbert Radeck ◽  
Udo Weber ◽  
Jérôme Touzel

Abstract Dynamic Random Access Memory (DRAM) is the one most widespread commodity product of the microelectronic industry. Although the basis structure is quite simple, an indepth electrical characterization of the single cell is mostly correlated with huge efforts in terms of test patterns due to the multiple possibilities for leakage of the cell itself [1]. A direct characterization of the access transistor is not possible because of the missing contact on the drain side (Deep Trench side). A tentative method to overcome this problem has been reported by G. Zimmermann, by using a front side Focused Ion Beam (FIB) contact to access the drain [2]. Unfortunately this method is limited to “coarse” technologies down to 0.15µm due to the resolution of the FIB probe. In addition, the backside contacting via trench allows the measurement of resistance and/or leakage elements at the interface buried strap, Poly 1-Poly 2 within DT (process conditioned). This paper presents an innovative way to contact the access transistor from the backside of the die, using the deep trench of the cell itself as connection to the drain of the investigated device. The backside contact to the polysilicon filled DT is the key aspect of the method and is realised by backside Focused Ion Beam.


2019 ◽  
Vol 9 (1) ◽  
pp. 235-241 ◽  
Author(s):  
M. M. Da Silva ◽  
A. R. Vaz ◽  
S. A. Moshkalev ◽  
J. W. Swart

Author(s):  
Z. G. Song ◽  
S. K. Loh ◽  
X. H. Zheng ◽  
S.P. Neo ◽  
C. K. Oh

Abstract This article presents two cases to demonstrate the application of focused ion beam (FIB) circuit edit in analysis of memory failure of silicon on insulator (SOI) devices using XTEM and EDX analyses. The first case was a single bit failure of SRAM units manufactured with 90 nm technology in SOI wafer. The second case was the whole column failure with a single bit pass for a SRAM unit. From the results, it was concluded that FIB circuit edit and electrical characterization is a good methodology for further narrowing down the defective location of memory failure, especially for SOI technology, where contact-level passive voltage contrast is not suitable.


Author(s):  
Chuan Zhang ◽  
Jane Y. Li ◽  
John Aguada ◽  
Howard Marks

Abstract This paper introduces a novel sample preparation method using plasma focused ion-beam (pFIB) milling at low grazing angle. Efficient and high precision preparation of site-specific cross-sectional samples with minimal alternation of device parameters can be achieved with this method. It offers the capability of acquiring a range of electrical characteristic signals from specific sites on the cross-section of devices, including imaging of junctions, Fins in the FinFETs and electrical probing of interconnect metal traces.


Author(s):  
Dirk Doyle ◽  
Lawrence Benedict ◽  
Fritz Christian Awitan

Abstract Novel techniques to expose substrate-level defects are presented in this paper. New techniques such as inter-layer dielectric (ILD) thinning, high keV imaging, and XeF2 poly etch overflow are introduced. We describe these techniques as applied to two different defects types at FEOL. In the first case, by using ILD thinning and high keV imaging, coupled with focused ion beam (FIB) cross section and scanning transmission electron microscopy (STEM,) we were able to judge where to sample for TEM from a top down perspective while simultaneously providing the top down images giving both perspectives on the same sample. In the second case we show retention of the poly Si short after removal of CoSi2 formation on poly. Removal of the CoSi2 exposes the poly Si such that we can utilize XeF2 to remove poly without damaging gate oxide to reveal pinhole defects in the gate oxide. Overall, using these techniques have led to 1) increased chances of successfully finding the defects, 2) better characterization of the defects by having a planar view perspective and 3) reduced time in localizing defects compared to performing cross section alone.


Author(s):  
Hui Pan ◽  
Thomas Gibson

Abstract In recent years, there have been many advances in the equipment and techniques used to isolate faults. There are many options available to the failure analyst. The available techniques fall into the categories of electrical, photonic, thermal and electron/ion beam [1]. Each technique has its advantages and its limitations. In this paper, we introduce a case of successful failure analysis using a combination of several fault localization techniques on a 0.15um CMOS device with seven layers of metal. It includes electrical failure mode characterization, front side photoemission, backside photoemission, Focused Ion Beam (FIB), Scanning Electron Microscope (SEM) and liquid crystal. Electrical characterization along with backside photoemission proved most useful in this case as a poly short problem was found to be causing a charge pump failure. A specific type of layout, often referred to as a hammerhead layout, and the use of Optical Proximity Correction (OPC) contributed to the poly level shorts.


Author(s):  
H. Lorenz ◽  
C. Engel

Abstract Due to the continuously decreasing cell size of DRAMs and concomitantly diminishing thickness of some insulating layers new failure mechanisms appear which until now had no significance for the cell function. For example high resistance leakage paths between closely spaced conductors can lead to retention problems. These are hard to detect by electrical characterization in a memory tester because the involved currents are in the range of pA. To analyze these failures we exploit the very sensitive passive voltage contrast of the Focused Ion Beam Microscope (FIB). The voltage contrast can further be enhanced by in-situ FIB preparations to obtain detailed information about the failure mechanism. The first part of this paper describes a method to detect a leakage path between a borderless contact on n-diffusion and an adjacent floating gate by passive voltage contrast achieved after FIB circuit modification. In the second part we will demonstrate the localization of a DRAM trench dielectric breakdown. In this case the FIB passive voltage contrast technique is not limited to the localization of the failing trench. We can also obtain the depth of the leakage path by selective insitu etching with XeF2 stopped immediately after a voltage contrast change.


Sign in / Sign up

Export Citation Format

Share Document