Regularities of changes in microhardness in the volume of EDT-69N binder cured at different temperatures

2020 ◽  
Vol 4 ◽  
pp. 65-71
Author(s):  
E.A. Veshkin ◽  
◽  
V.I. Postnov ◽  
V.V. Semenychev ◽  
E.V. Krasheninnikova ◽  
...  

The change in the microhardness over the thickness of samples made of EDT-69N binder cured in vacuum and at atmospheric pressure at temperatures from 130 to 170°C was investigated. It was found that the change in microhardness along the thickness of the samples occurs according to the parabolic law, with the maximum values being achieved in the middle of the sample cross-section along the thickness. With an increase in the molding temperature, the microhardness in the middle section of the sample increases from 222 MPa at a molding temperature of 130°C to 410 MPa during molding at 170°C. At the critical molding temperature (170°C), the microhardness in all zones of the specimen cross section (subsurface, semi-average, and core) levels off, while the parabolic dependence degenerates into a straight line. It is shown that the method of scratching (sclerometry) demonstrated a sufficiently high sensitivity to the state of samples cured at different temperatures. With an increase in the molding temperature, the width of the sclerometric grooves decreases. At a critical molding temperature of 170°C, the groove width is stabilized and becomes constant throughout the sample thickness. To characterize the difference in the values of the microhardness of the cured binder in the sample volume, it is proposed to use a dimensionless “coefficient of volume anisotropy,” which can take a positive, negative or zero value. With an increase in the curing temperature of the binder and, accordingly, with an increase in the microhardness of the sample, the coefficient of volume anisotropy decreases, and when the samples are molded at the critical temperature, it turns to zero, which indicates the absence of anisotropy.

2016 ◽  
Vol 35 (2) ◽  
pp. 118-122 ◽  
Author(s):  
Milica Ranković Janevski ◽  
Ana Đorđević Vujičić ◽  
Svjetlana Maglajić Đukić

Summary Background: Salivary cortisol measurement is a non-invasive method suitable for use in neonatal research. Mother-infant separation after birth represents stress and skin-to-skin contact (SSC) has numerous benefits. The aim of the study was to measure salivary cortisol in mothers and newborns before and after SSC in order to assess the effect of SSC on mothers’ and infants’ stress and to estimate the efficacy of collecting small saliva samples in newborns. Methods: Salivary cortisol was measured in 35 mother-infant pairs before and after the first and the fifth SSC in small saliva samples (50 μL) using the high sensitivity Quantitative ELISA-Kit (0.0828 nmol/L) for low cortisol levels detection. Samples were collected with eye sponge during 3 to 5 minutes. Results: Cortisol level in mothers decreased after SSC: the highest levels were measured before and the lowest after SSC and the differences in values were significant during both the first (p<0.001) and the fifth SSC (p<0.001). During the first SSC the cortisol level decrease was detected in 14 (40%) and an increase in 21 (60%) newborns, and during the fifth SSC a decrease was detected in 16 (45.7%) and an increase in 19 (54.3%) newborns, without confirmed significance of the difference. Saliva sampling efficacy using eye sponge was 75%. Conclusions: Cortisol level decrease in mothers proves the stress reduction during SSC, while variable cortisol levels in infants do not indicate stress reduction and imply the need for further research. The used sampling method appeared to be one of the most optimal considering the sample volume, sampling time and efficacy.


2019 ◽  
pp. 27-30
Author(s):  
E. A. Veshkin ◽  
V. I. Postnov ◽  
V. V. Semenychev ◽  
E. V. Krasheninnikova

Samples of polyester binder RO-4761 were irradiated using an ultraviolet device. The investigations established that the microhardness of the polymer along its cross section, from the surface to core of the sample, varies according to a parabolic law. With increasing time of UV exposure the sample, its microhardness increases. When the binder is fully cured, the parabolic curve transforms into a straight line. A new term is proposed that characterizes the change in microhardness in the volume of the cured polymer: “Volume anisotropy coefficient”.


1979 ◽  
Vol 7 (1) ◽  
pp. 31-39
Author(s):  
G. S. Ludwig ◽  
F. C. Brenner

Abstract An automatic tread gaging machine has been developed. It consists of three component systems: (1) a laser gaging head, (2) a tire handling device, and (3) a computer that controls the movement of the tire handling machine, processes the data, and computes the least-squares straight line from which a wear rate may be estimated. Experimental tests show that the machine has good repeatability. In comparisons with measurements obtained by a hand gage, the automatic machine gives smaller average groove depths. The difference before and after a period of wear for both methods of measurement are the same. Wear rates estimated from the slopes of straight lines fitted to both sets of data are not significantly different.


Author(s):  
D. T. Gauld ◽  
J. E. G. Raymont

The respiratory rates of three species of planktonic copepods, Acartia clausi, Centropages hamatus and Temora longicornis, were measured at four different temperatures.The relationship between respiratory rate and temperature was found to be similar to that previously found for Calanus, although the slope of the curves differed in the different species.The observations on Centropages at 13 and 170 C. can be divided into two groups and it is suggested that the differences are due to the use of copepods from two different generations.The relationship between the respiratory rates and lengths of Acartia and Centropages agreed very well with that previously found for other species. That for Temora was rather different: the difference is probably due to the distinct difference in the shape of the body of Temora from those of the other species.The application of these measurements to estimates of the food requirements of the copepods is discussed.


Universe ◽  
2021 ◽  
Vol 7 (3) ◽  
pp. 72
Author(s):  
Clementina Agodi ◽  
Antonio D. Russo ◽  
Luciano Calabretta ◽  
Grazia D’Agostino ◽  
Francesco Cappuzzello ◽  
...  

The search for neutrinoless double-beta (0νββ) decay is currently a key topic in physics, due to its possible wide implications for nuclear physics, particle physics, and cosmology. The NUMEN project aims to provide experimental information on the nuclear matrix elements (NMEs) that are involved in the expression of 0νββ decay half-life by measuring the cross section of nuclear double-charge exchange (DCE) reactions. NUMEN has already demonstrated the feasibility of measuring these tiny cross sections for some nuclei of interest for the 0νββ using the superconducting cyclotron (CS) and the MAGNEX spectrometer at the Laboratori Nazionali del Sud (LNS.) Catania, Italy. However, since the DCE cross sections are very small and need to be measured with high sensitivity, the systematic exploration of all nuclei of interest requires major upgrade of the facility. R&D for technological tools has been completed. The realization of new radiation-tolerant detectors capable of sustaining high rates while preserving the requested resolution and sensitivity is underway, as well as the upgrade of the CS to deliver beams of higher intensity. Strategies to carry out DCE cross-section measurements with high-intensity beams were developed in order to achieve the challenging sensitivity requested to provide experimental constraints to 0νββ NMEs.


Materials ◽  
2021 ◽  
Vol 14 (2) ◽  
pp. 431
Author(s):  
Giorgio Turri ◽  
Scott Webster ◽  
Michael Bass ◽  
Alessandra Toncelli

Spectroscopic properties of neodymium-doped yttrium lithium fluoride were measured at different temperatures from 35 K to 350 K in specimens with 1 at% Nd3+ concentration. The absorption spectrum was measured at room temperature from 400 to 900 nm. The decay dynamics of the 4F3/2 multiplet was investigated by measuring the fluorescence lifetime as a function of the sample temperature, and the radiative decay time was derived by extrapolation to 0 K. The stimulated-emission cross-sections of the transitions from the 4F3/2 to the 4I9/2, 4I11/2, and 4I13/2 levels were obtained from the fluorescence spectrum measured at different temperatures, using the Aull–Jenssen technique. The results show consistency with most results previously published at room temperature, extending them over a broader range of temperatures. A semi-empirical formula for the magnitude of the stimulated-emission cross-section as a function of temperature in the 250 K to 350 K temperature range, is presented for the most intense transitions to the 4I11/2 and 4I13/2 levels.


2015 ◽  
Vol 2015 ◽  
pp. 1-5 ◽  
Author(s):  
Giselle Nevares ◽  
Felipe Xavier ◽  
Luciana Gominho ◽  
Flávia Cavalcanti ◽  
Marcely Cassimiro ◽  
...  

This study aimed to analyse and compare apical extrusion of debris in canals instrumented with systems used in reciprocating and continuous motion. Sixty mandibular premolars were randomly divided into 3 groups (n=20): the Reciproc (REC), WaveOne (WO), and HyFlex CM (HYF) groups. One Eppendorf tube per tooth was weighed in advance on an analytical balance. The root canals were instrumented according to the manufacturer’s instructions, and standardised irrigation with 2.5% sodium hypochlorite was performed to a total volume of 9 mL. After instrumentation, the teeth were removed from the Eppendorf tubes and incubated at 37°C for 15 days to evaporate the liquid. The tubes were weighed again, and the difference between the initial and final weight was calculated to determine the weight of the debris. The data were statistically analysed using the Shapiro-Wilk, Wilcoxon, and Mann-Whitney tests (α=5%). All systems resulted in the apical extrusion of debris. Reciproc produced significantly more debris than WaveOne (p<0.05), and both systems produced a greater apical extrusion of debris than HyFlex CM (p<0.001). Cross section and motion influenced the results, despite tip standardization.


1878 ◽  
Vol 28 (2) ◽  
pp. 633-671 ◽  
Author(s):  
Alexander Macfarlane

The experiments to which I shall refer were carried out in the physical laboratory of the University during the late summer session. I was ably assisted in conducting the experiments by three students of the laboratory,—Messrs H. A. Salvesen, G. M. Connor, and D. E. Stewart. The method which was used of measuring the difference of potential required to produce a disruptive discharge of electricity under given conditions, is that described in a paper communicated to the Royal Society of Edinburgh in 1876 in the names of Mr J. A. Paton, M. A., and myself, and was suggested to me by Professor Tait as a means of attacking the experimental problems mentioned below.The above sketch which I took of the apparatus in situ may facilitate tha description of the method. The receiver of an air-pump, having a rod capable of being moved air-tight up and down through the neck, was attached to one of the conductors of a Holtz machine in such a manner that the conductor of the machine and the rod formed one conducting system. Projecting from the bottom of the receiver was a short metallic rod, forming one conductor with the metallic parts of the air-pump, and by means of a chain with the uninsulated conductor of the Holtz machine. Brass balls and discs of various sizes were made to order, capable of being screwed on to the ends of the rods. On the table, and at a distance of about six feet from the receiver, was a stand supporting two insulated brass balls, the one fixed, the other having one degree of freedom, viz., of moving in a straight line in the plane of the table. The fixed insulated ball A was made one conductor with the insulated conductor of the Holtz and the rod of the receiver, by means of a copper wire insulated with gutta percha, having one end stuck firmly into a hole in the collar of the receiver, and having the other fitted in between the glass stem and the hollow in the ball, by which it fitted on to the stem tightly. A thin wire similarly fitted in between the ball B and its insulating stem connected the ball with the insulated half ring of a divided ring reflecting electrometer.


2013 ◽  
Vol 457-458 ◽  
pp. 65-71
Author(s):  
Jing Ru Jia

The polyfunctional organic compounds 2- hydroxymethyl -1,4- butanediol (trihydric alcohol) and toluene diisocyanate -2, 4- diisocyanate (TDI) were taken as the raw materials in this study. A polyurethane dendrimer was synthesized by utilizing the difference in the reaction activity of two isocyanate groups of TDI at different temperatures. The polymerization process conditions were studied. The addition polymerization of para-position NCO groups occurred at 50 °C, and that of ortho NCO groups occurred at 90 °C. According to the structure of the dendrimer synthesized, methyl orange was used as the guest molecule. Consequently, the aqueous methyl orange showed a phase transfer. With the increase of dendrimer concentration, the transfer rate of methyl orange increased.


Sign in / Sign up

Export Citation Format

Share Document