Alternative Sample Preparation Technique for Die Level Parallel Lapping Analysis

Author(s):  
Hoon Ye Gwee ◽  
Kiong Kay Ng

Abstract Parallel lapping (often called delayering) is a commonly used process in failure analysis of integrated circuits. However, parallel lapping commonly gives rise to the issue of weak sample preparation method especially on specimen mounting. The traditional specimen mounting technique was done by mounted a single die to polishing fixture using drop of super glue. Using conventional methods, problems such as losing the die during polishing, serious edge rounding are often encountered. Further, loading the whole polishing fixture into Scanning Electron Microscopy machine for SEM imaging or Passive Voltage Contrast (PVC) fault localization can be complicated due to the size of polishing fixture. Therefore, an alternative, relatively fast and simple method to overcome the above mentioned obstacles is proposed.

Nanoscale ◽  
2018 ◽  
Vol 10 (48) ◽  
pp. 22884-22895 ◽  
Author(s):  
Daniel Staaks ◽  
Deirdre L. Olynick ◽  
Ivo W. Rangelow ◽  
M. Virginia P. Altoe

A new composite sample preparation method for high contrast cross-sectional SEM imaging.


1983 ◽  
Vol 11 (4) ◽  
pp. 303-305 ◽  
Author(s):  
J. Vanhellemont ◽  
H. Bender ◽  
C. Claeys ◽  
J. Van Landuyt ◽  
G. Declerck ◽  
...  

2020 ◽  
Author(s):  
Gert Johannes Kruger Marais ◽  
Michelle Naidoo ◽  
Nei-yuan Hsiao ◽  
Ziyaad Valley-Omar ◽  
Heidi Smuts ◽  
...  

The SARS-CoV-2 pandemic has resulted in shortages of both critical reagents for nucleic acid purification and highly trained staff as supply chains are strained by high demand, public health measures and frequent quarantining and isolation of staff. This created the need for alternate workflows with limited reliance on specialised reagents, equipment and staff. We present here the validation and implementation of such a workflow for preparing samples for downstream SARS-CoV-2 RT-PCR using liquid handling robots. The rapid sample preparation technique evaluated, which included sample centrifugation and heating prior to RT-PCR, showed a 97.37% (95% CI: 92.55-99.28%) positive percent agreement and 97.30% (95% CI: 90.67-99.52%) negative percent agreement compared to nucleic acid purification-based testing. This method was subsequently adopted as the primary sample preparation method in the Groote Schuur Hospital Virology Diagnostic Laboratory in Cape Town, South Africa.


Author(s):  
Jayesh Bellare

Seeing is believing, but only after the sample preparation technique has received a systematic study and a full record is made of the treatment the sample gets.For microstructured liquids and suspensions, fast-freeze thermal fixation and cold-stage microscopy is perhaps the least artifact-laden technique. In the double-film specimen preparation technique, a layer of liquid sample is trapped between 100- and 400-mesh polymer (polyimide, PI) coated grids. Blotting against filter paper drains excess liquid and provides a thin specimen, which is fast-frozen by plunging into liquid nitrogen. This frozen sandwich (Fig. 1) is mounted in a cooling holder and viewed in TEM.Though extremely promising for visualization of liquid microstructures, this double-film technique suffers from a) ireproducibility and nonuniformity of sample thickness, b) low yield of imageable grid squares and c) nonuniform spatial distribution of particulates, which results in fewer being imaged.


Author(s):  
Jian-Shing Luo ◽  
Hsiu Ting Lee

Abstract Several methods are used to invert samples 180 deg in a dual beam focused ion beam (FIB) system for backside milling by a specific in-situ lift out system or stages. However, most of those methods occupied too much time on FIB systems or requires a specific in-situ lift out system. This paper provides a novel transmission electron microscopy (TEM) sample preparation method to eliminate the curtain effect completely by a combination of backside milling and sample dicing with low cost and less FIB time. The procedures of the TEM pre-thinned sample preparation method using a combination of sample dicing and backside milling are described step by step. From the analysis results, the method has applied successfully to eliminate the curtain effect of dual beam FIB TEM samples for both random and site specific addresses.


Author(s):  
Pradip Sairam Pichumani ◽  
Fauzia Khatkhatay

Abstract Silicon photonics is a disruptive technology that aims for monolithic integration of photonic devices onto the complementary metal-oxide-semiconductor (CMOS) technology platform to enable low-cost high-volume manufacturing. Since the technology is still in the research and development phase, failure analysis plays an important role in determining the root cause of failures seen in test vehicle silicon photonics modules. The fragile nature of the test vehicle modules warrants the development of new sample preparation methods to facilitate subsequent non-destructive and destructive analysis methods. This work provides an example of a single step sample preparation technique that will reduce the turnaround time while simultaneously increasing the scope of analysis techniques.


Author(s):  
Alexander Sorkin ◽  
Chris Pawlowicz ◽  
Alex Krechmer ◽  
Michael W. Phaneuf

Abstract Competitive circuit analysis of Integrated Circuits (ICs) is one of the most challenging types of analysis. It involves multiple complex IC die de-processing/de-layering steps while keeping precise planarity from metal layer to metal layer. Each step is followed by Scanning Electron Microscope (SEM) imaging together with mosaicking that subsequently passes through an image recognition and Graphic Database System (GDS) conversion process. This conventional procedure is quite time and resource consuming. The current paper discusses and demonstrates a new inventive methodology of circuit tracing on an IC using known FIB Passive Voltage Contrast (PVC) effects [1]. This technique provides significant savings in time and resources.


Author(s):  
Swaminathan Subramanian ◽  
Khiem Ly ◽  
Tony Chrastecky

Abstract Visualization of dopant related anomalies in integrated circuits is extremely challenging. Cleaving of the die may not be possible in practical failure analysis situations that require extensive electrical fault isolation, where the failing die can be submitted of scanning probe microscopy analysis in various states such as partially depackaged die, backside thinned die, and so on. In advanced technologies, the circuit orientation in the wafer may not align with preferred crystallographic direction for cleaving the silicon or other substrates. In order to overcome these issues, a focused ion beam lift-out based approach for site-specific cross-section sample preparation is developed in this work. A directional mechanical polishing procedure to produce smooth damage-free surface for junction profiling is also implemented. Two failure analysis applications of the sample preparation method to visualize junction anomalies using scanning microwave microscopy are also discussed.


Molecules ◽  
2021 ◽  
Vol 26 (8) ◽  
pp. 2277
Author(s):  
Piotr M. Kuś ◽  
Igor Jerković

Recently, we proposed a new sample preparation method involving reduced solvent and sample usage, based on dehydration homogeneous liquid–liquid extraction (DHLLE) for the screening of volatiles and semi-volatiles from honey. In the present research, the method was applied to a wide range of honeys (21 different representative unifloral samples) to determine its suitability for detecting characteristic honey compounds from different chemical classes. GC-FID/MS disclosed 130 compounds from different structural and chemical groups. The DHLLE method allowed the extraction and identification of a wide range of previously reported specific and nonspecific marker compounds belonging to different chemical groups (including monoterpenes, norisoprenoids, benzene derivatives, or nitrogen compounds). For example, DHLLE allowed the detection of cornflower honey chemical markers: 3-oxo-retro-α-ionols, 3,4-dihydro-3-oxoedulan, phenyllactic acid; coffee honey markers: theobromine and caffeine; linden honey markers: 4-isopropenylcyclohexa-1,3-diene-1-carboxylic acid and 4-(2-hydroxy-2-propanyl)cyclohexa-1,3-diene-1-carboxylic acid, as well as furan derivatives from buckwheat honey. The obtained results were comparable with the previously reported data on markers of various honey varieties. Considering the application of much lower volumes of very common reagents, DHLLE may provide economical and ecological advantages as an alternative sample preparation method for routine purposes.


Sign in / Sign up

Export Citation Format

Share Document