scholarly journals A Combined Strategy to Improve the Performance of Dental Alloys Using a New CoCrNbMoZr Alloy with Mn and Si Coated via an Anodic Oxidation Procedure

Metals ◽  
2021 ◽  
Vol 11 (7) ◽  
pp. 1017
Author(s):  
Florentina Gina Ionascu ◽  
Mariana Prodana ◽  
Florentina Golgovici ◽  
Ioana Demetrescu

The aim of the paper is based on a combined approach to improve dental alloy performance using a new Ni-free Co–Cr composition with Mo, Nb and Zr and coated with an anodic oxidation film. The coated and uncoated samples were surface characterized by performing SEM (scanning electronic microscopy), XRD (X-rays diffraction) contact angle measurements and corrosion studies with open circuit potential, potentiodynamic polarization and EIS (impedance electrochemical spectroscopy) procedures. The SEM equipment with an EDX (Energy-dispersive X-ray spectroscopy) module indicated the sample morphology and the XRD investigations established the formation of the oxides. The electrochemical procedures were performed in Ericsson artificial saliva for coated samples in various conditions. Based on all the experiments, including the decrease in the hydrophobic character of the uncoated samples and the decrease in the hydrophilic values of the anodized alloys, the improved performance of the coated samples was established as a conclusion.

2012 ◽  
Vol 23 (2) ◽  
pp. 141-148 ◽  
Author(s):  
Rodrigo Galo ◽  
Ricardo Faria Ribeiro ◽  
Renata Cristina Silveira Rodrigues ◽  
Luís Augusto Rocha ◽  
Maria da Glória Chiarello de Mattos

The aim of this study was to determine the effect of the oral environment on the corrosion of dental alloys with different compositions, using electrochemical methods. The corrosion rates were obtained from the current-potential curves and electrochemical impedance spectroscopy (EIS). The effect of artificial saliva on the corrosion of dental alloys was dependent on alloy composition. Dissolution of the ions occurred in all tested dental alloys and the results were strongly dependent on the general alloy composition. Regarding the alloys containing nickel, the Ni-Cr and Ni-Cr-Ti alloys released 0.62 mg/L of Ni on average, while the Co-Cr dental alloy released ions between 0.01 and 0.03 mg/L of Co and Cr, respectively.The open-circuit potential stabilized at a higher level with lower deviation (standard deviation: Ni-Cr-6Ti = 32 mV/SCE and Co-Cr = 54 mV/SCE). The potenciodynamic curves of the dental alloys showed that the Ni-based dental alloy with >70 wt% of Ni had a similar curve and the Co-Cr dental alloy showed a low current density and hence a high resistance to corrosion compared with the Ni-based dental alloys. Some changes in microstructure were observed and this fact influenced the corrosion behavior for the alloys. The lower corrosion resistance also led to greater release of nickel ions to the medium. The quantity of Co ions released from the Co-Cr-Mo alloy was relatively small in the solutions. In addition, the quantity of Cr ions released into the artificial saliva from the Co-Cr alloy was lower than Cr release from the Ni-based dental alloys.


2015 ◽  
Vol 60 (1) ◽  
pp. 523-528 ◽  
Author(s):  
A. Łukaszczyk ◽  
J. Augustyn-PieniąŻek

Abstract The presented paper studies the effect of the casting technology on the corrosion resistance of Co-Cr-Mo alloy. The investigations were conducted on a commercial alloy with the brand name ARGELOY N.P SPECIAL (Co-Cr-Mo) produced by Argen as well as the same alloy melted and cast by the lost wax casting method performed by a dental technician. The corrosion behavior of the dental alloys in an artificial saliva was studied with the use of the following electrochemical techniques: open circuit potential and voltammetry. After the electrochemical tests, studies of the surface of the examined alloys were performed by means of a scanning electron microscope with an X-ray microanalyzer. The results of the electrochemical studies show that the dependence of the corrosion resistance on the microstructure associated with the recasting process is marginal. The results of the electrochemical studies of the considered alloy clearly point to their good corrosion resistance in the discussed environment.


2019 ◽  
Vol 8 (6) ◽  
pp. 435-440
Author(s):  
Asmaa Marda ◽  
Khadija Mouflih ◽  
Abdelkebir Bellaouchou ◽  
Abdallah Guenbour ◽  
Asmae Elmansari ◽  
...  

This study aimed to compare the resistance of dental alloys to corrosion in a solution containing oral bacteria named Streptococcus mutans (S.mutans). The electrochemical behavior of Nickel-Titanium (NiTi) was investigated in sterile Fusayama artificial saliva (AS) with the enrichment medium tryptic soy broth (TSB) in solution 1 and (AS) with (TSB) and bacteria in solution 2. The electrochemical procedures selected for this work were open circuit potentials (OCP), Potentiodynamic polarization (PDP), and electrochemical impedance spectroscopy (EIS). The NiTi surface was examined using optical microscopy.      After 24 hours of immersion in artificial saliva, the results have shown that NiTi revealed high corrosion reactivity in the presence of S. mutans and present pitting corrosion on the surface.


Materials ◽  
2021 ◽  
Vol 14 (16) ◽  
pp. 4635
Author(s):  
Farah Bechir ◽  
Simona Maria Bataga ◽  
Elena Ungureanu ◽  
Diana Maria Vranceanu ◽  
Mariana Pacurar ◽  
...  

Cobalt-chromium (Co-Cr) alloys are widely utilized in dentistry. The salivary pH is a significant factor, which affects the characteristics and the behavior of dental alloys through corrosion. This study aimed to evaluate the corrosion behavior in artificial saliva with different pH values (3, 5.7, and 7.6) of two commercial Co-Cr dental alloys manufactured by casting and by milling. Corrosion resistance was determined by the polarization resistance technique, and the tests were carried out at 37 ± 1 °C, in Carter Brugirard artificial saliva. After the electrochemical parameters, it can be stated that the cast Co-Cr alloy has the lowest corrosion current density, the highest polarization resistance, and the lowest speed of corrosion in artificial saliva with pH = 7.6. In the case of milled Co-Cr alloy, the same behavior was observed, but in artificial saliva with pH = 5.7, it recorded the most electropositive values of open circuit potential and corrosion potential. Although both cast and milled Co-Cr alloys presented a poorer corrosion resistance in artificial saliva with a more acidic pH value, the milled Co-Cr alloy had better corrosion behavior, making this alloy a better option for the prosthetic treatment of patients suffering from GERD.


2008 ◽  
Vol 8 (4) ◽  
pp. 1835-1841 ◽  
Author(s):  
R. Valsecchi ◽  
M. Viganò ◽  
M. Levi ◽  
S. Turri

Quaternary ammonium salts based on monofunctionalized Perfluoropolyether (PFPE) oligomers were synthesized and used for the cation exchange process of sodium Montmorillonite nanoclays. The new fluoromodified nanoclays were characterized through X-rays diffraction (XRD), Fourier transform infrared spectroscopy (FTIR), termogravimetric analysis (TGA), differential scanning calorimetry (DSC), electronic microscopy (SEM-EDS), and contact angle measurements (CA). In particular XRD showed rather complex patterns (presence of higher order reflections) which allowed the calculation of basal spacings, regularly increasing with the molecular weight of the fluorinated macrocation. Both IR and SEM confirmed the presence of fluorinated segments at clays interface, while TGA showed a limited thermal stability with an onset of degradation temperature which seems not dependent on the molecular weight of the macrocation. CA measurements showed a peculiar behaviour, with evident dynamic hysteresis phenomena and surface tension components quite different from those of commercially available, organomodified clays.


2002 ◽  
Vol 727 ◽  
Author(s):  
Denys Usov ◽  
Manfred Stamm ◽  
Sergiy Minko ◽  
Christian Froeck ◽  
Andreas Scholl ◽  
...  

AbstractWe investigated the interplay between different mechanisms of the lateral and vertical segregation in the synthesized via “grafting from” approach symmetric A/B (where A and B are poly(styrene-co-2,3,4,5,6-pentafluorostyrene) and poly(methylmethacrylate), respectively) polymer brushes upon exposure to different solvents. We used X-ray photoemission electron spectroscopy and microscopy (X-PEEM), AFM, water contact angle measurements, and oxygen plasma etching to study morphology of the brushes. The ripple morphology after toluene (nonselective solvent) revealed elongated lamellar-like domains of A and B polymers alternating across the surface. The dimple-A morphology consisting of round clusters of the polymer A was observed after acetone (selective solvent for B). The top layer was enriched with the polymer B showing that the brush underwent both the lateral and vertical phase segregation. A qualitative agreement with predictions of SCF theory was found.


2020 ◽  
Author(s):  
Michelina Soccio ◽  
Nadia Lotti ◽  
Andrea Munari ◽  
Esther Rebollar ◽  
Daniel E Martínez-Tong

<p>Nanostructured wrinkles were developed on fully bio-based poly(trimethylene furanoate) (PTF) films by using the technique of Laser Induced Periodic Surface Structures (LIPSS). We investigated the effect of irradiation time on wrinkle formation using an UV pulsed laser source, at a fluence of 8 mJ/cm2. It was found that the pulse range between 600 and 4800 pulses allowed formation of periodic nanometric ripples. The nanostructured surface was studied using a combined macro- and nanoscale approach. We evaluated possible physicochemical changes taking place on the polymer surface after irradiation by infrared spectroscopy, contact angle measurements and atomic force microscopy. The macroscopic physicochemical properties of PTF showed almost no changes after nanostructure formation, differently from the results previously found for the terephthalic counterparts, as poly(ethyleneterephthalate), PET, and poly(trimethyleneterephthalate), PTT. The surface mechanical properties of the nanostructured PTF were found to be improved, as evidenced by nanomechanical force spectroscopy measurements. In particular, an increased Young’s modulus and higher stiffness for the nanostructured sample were measured. <br></p>


2018 ◽  
Vol 69 (6) ◽  
pp. 1598-1602
Author(s):  
Alice Arina Ciocan Pendefunda ◽  
Constanta Mocanu ◽  
Doriana Agop Forna ◽  
Cristina Iordache ◽  
Elena Luca ◽  
...  

The purpose of the study is to investigate the electrochemical behavior of two dental alloys: palladium alloy (Palidor) and Ni-Cr alloy (Verasoft) in three types of artificial saliva. Determination of corrosion potential and recording of linear and cyclic polarization curves were performed with PGP201 potentiostat (VoltaLab 21- Radelkis Copenhagen. In order to study the modifications produced on the surface of the electrodes, a complex optical microscope MC 1 research type (IOR, Romania) was used, adapted to a digital camera, which was connected to a computer for the digital acquisition of images . Two metal alloys based on Ag-Pd and Ni-Cr were used for the experiments. The materials used came from different types of dental restorations removed from the oral cavity of the patients after a 5-15 years period. As corrosion environments, three artificial saliva were used: Fusayama, Afnor and Rondelli. The Pd-Ag dental alloy exhibits a very good corrosion resistance and the treatment in the Afnor saliva does not affect the surface of the alloy. Electrochemical behavior in Fusayama-Meyer�s saliva of the alloy surface results in a series of spots representing deposits of insoluble salts resulting from the oxidation process, while in the Rondelli saliva there is a series of small corrosion points on the alloy surface. The behavior of the Verasoft alloy in the Afnor and Rondelli saliva is similar; In both solutions, the potential breakthroughs are very close, but in Fusayama-Meyer�s saliva, the potential for initiation of corrosion points is very low (206 mV), a potential that can be encountered in the oral cavity. All metals and metal alloys, even the noble and semi-precious ones, are susceptible to corrosion, forming compounds with properties different from those of the metal or base alloy, which change their surface condition. Metallic dental restorations are permanently affected by the factors of the oral environment (physical-mechanical, chemical and biological), being subjected to a continuous process of degradation.


Metals ◽  
2021 ◽  
Vol 11 (2) ◽  
pp. 256
Author(s):  
Florentina Golgovici ◽  
Mariana Prodana ◽  
Florentina Gina Ionascu ◽  
Ioana Demetrescu

The purpose of our study is to compare the behavior of two reprocessed dental alloys (NiCr and CoCr) at different temperatures considering the idea that food and drinks in the oral cavity create various compositions at different pH levels; the novelty is the investigation of temperature effect on corrosion parameters and ion release of dental alloys. Electrochemical stability was studied together with morphology, elemental composition and ions release determination. The results obtained are in good concordance: electrochemistry studies reveal that the corrosion rate is increasing by increasing the temperature. From SEM coupled with EDS, the oxide film formed on the surface of the alloys is stable at low temperatures and a trend to break after 310K. ICP-MS results evidence that in accordance with increasing temperature, the quantities of ions released from the alloys immersed in artificial saliva also increase, though they still remain small, less than 20 ppm.


Crystals ◽  
2021 ◽  
Vol 11 (2) ◽  
pp. 202
Author(s):  
Réka Barabás ◽  
Carmen Ioana Fort ◽  
Graziella Liana Turdean ◽  
Liliana Bizo

In the present work, ZrO2-based composites were prepared by adding different amounts of antibacterial magnesium oxide and bioactive and biocompatible hydroxyapatite (HAP) to the inert zirconia. The composites were synthesized by the conventional ceramic processing route and morpho-structurally analyzed by X-ray powder diffraction (XRPD) and scanning electron microscopy/energy dispersive X-ray spectroscopy (SEM/EDS). Two metallic dental alloys (i.e., Ni–Cr and Co–Cr) coated with a chitosan (Chit) membrane containing the prepared composites were exposed to aerated artificial saliva solutions of different pHs (i.e., 4.3, 5, 6) and the corrosion resistances were investigated by electrochemical impedance spectroscopy technique. The obtained results using the two investigated metallic dental alloys shown quasi-similar anticorrosive properties, having quasi-similar charge transfer resistance, when coated with different ZrO2-based composites. This behavior could be explained by the synergetic effect between the diffusion process through the Chit-composite layer and the roughness of the metallic electrode surface.


Sign in / Sign up

Export Citation Format

Share Document