scholarly journals Effect of an Inducer-Type Guide Vane on Hydraulic Losses at the Inter-Stage Flow Passage of a Multistage Centrifugal Pump

Processes ◽  
2021 ◽  
Vol 9 (3) ◽  
pp. 526
Author(s):  
Mohamed Murshid Shamsuddeen ◽  
Sang-Bum Ma ◽  
Sung Kim ◽  
Ji-Hoon Yoon ◽  
Kwang-Hee Lee ◽  
...  

A multistage centrifugal pump was developed for high head and high flow rate applications. A double-suction impeller and a twin-volute were installed at the first stage followed by an impeller, diffuser and return vanes for the next four stages. An initial design feasibility study was conducted using three-dimensional computational fluid dynamics tools to study the performance and the hydraulic losses associated with the design. Substantial losses in head and efficiency were observed at the interface between the first stage volute and the second stage impeller. An inducer-type guide vane (ITGV) was installed at this location to mitigate the losses by reducing the circumferential velocity of the fluid exiting the volute. The ITGV regulated the pre-swirl of the fluid entering the second stage impeller. The pump with and without ITGV is compared at the design flow rate. The pump with ITGV increased the stage head by 63.28% and stage efficiency by 47.17% at the second stage. As a result, the overall performance of the pump increased by 5.78% and 3.94% in head and efficiency, respectively, at the design point. The ITGV has a significant impact on decreasing losses at both design and off-design conditions. An in-depth flow dynamic analysis at the inducer-impeller interface is also presented.

Author(s):  
Hucan Hou ◽  
Yongxue Zhang ◽  
Zhenlin Li ◽  
Xin Zhou ◽  
Zizhe Wang

In order to effectively improve hydraulic performance of centrifugal pump on off-conditions, the hydraulic design of inlet guide vane (IGV) was completed by adopting two dimensional theory in-house code based on one kind of IS series of centrifugal pump, which can achieve pre-whirl regulation of centrifugal pump. During design process the trailing edge of vane is assumed as equal velocity moment condition, and the distribution of vane setting angle along meridional streamline is also given as a quartic function firstly, the camber line is then drawn by point-by-point integration method and thickened at both sides along circumferential direction. With local vortex dynamics diagnosis theory, the optimal improvement of vane space shape can be finished by adjusting the design parameters of vane setting angle distribution coefficient ap. The full flow passage numerical simulations of centrifugal pump with IGV device are completed to analyze the influence of pre-whirl regulation on hydraulic performance of centrifugal pump under various pre-whirl angles. The results show that the pre-whirl regulation can improve the hydraulic performance of centrifugal pump on off-conditions. Under the positive pre-whirl regulation conditions, the best efficient point shift to small flow rate zone, and under the negative pre-whirl regulation conditions it moves to large flow rate zone. Compared with the pump without IGV device at the same flow rate condition of 0.8Q (Q the design flow rate), the hydraulic efficiency of centrifugal pump with IGV device improves obviously and reaches up to 1.43%. Meanwhile compared with that installed with the straight vanes designed based on the traditional theory, the inner flow field of centrifugal pump with the designed vanes improves and the overall hydraulic efficiency of centrifugal pump is somewhat increased.


2017 ◽  
Vol 9 (2) ◽  
pp. 168781401769249 ◽  
Author(s):  
Kai Wang ◽  
Zixu Zhang ◽  
Linglin Jiang ◽  
Houlin Liu ◽  
Yu Li

In order to save energy by broadening its application range, the influence of impeller trim on the performance of a two-stage self-priming centrifugal pump was numerically studied. The hydraulic performance experiments and self-priming experiments were carried out. And the unsteady performance of pressure fluctuation and radial force in the pump was analyzed. The results show that with the increase in impeller trim quantity, the best efficiency point of the pump would move to the small flow rate condition. Under the design flow rate, when both the two stages of the impeller were trimmed by 6%, head of the pump was reduced by 13%, efficiency of the pump was as well decreased by 1.69 percentage points, and self-priming time was increased by 1.7%. Thus, impeller trim can be used to meet the operating requirements in the head range of 94–107 m. With the increase in impellers trim quantity, the pressure fluctuation in the positive channel of the radial guide vane and the volute was smaller, while the radial force on the wall of radial guide vane and volute was also smaller.


2021 ◽  
Vol 9 (7) ◽  
pp. 771
Author(s):  
Xiaobo Gong ◽  
Ji Pei ◽  
Wenjie Wang ◽  
Majeed Koranteng Osman ◽  
Wei Jiang ◽  
...  

The high-pressure multistage centrifugal pump is the main piece of energy-consuming equipment in the reverse osmosis desalination process, and it consumes about 35% of the entire system’s operating cost. The optimization process of multi-stage pumps undoubtedly requires the performance comparison of multiple schemes in order to verify the effectiveness of the optimized design and the optimization method. Therefore, based on ANSYS Workbench and an improved bat algorithm, an intelligent optimization scheme was designed and carried out on a three-stage reverse osmosis desalination high-pressure pump for efficiency improvement by optimizing the matching relationship between the impeller and the guide vane. An external characteristic test was carried out in an open test rig system in order to verify the numerical model. After modifying the positive guide vane structure, the efficiency was improved for both the rated design and the non-design flow conditions without obvious separation and backflow. With the improved bat algorithm, there was a 3.98% increase in the design point efficiency after the final optimization. Under the design conditions, all of the large vortices disappeared after the optimization. The study provides a reference for the optimization design of the impeller–guide vane matching effect in a multistage pump using an improved bat algorithm.


2013 ◽  
Vol 2013 ◽  
pp. 1-7 ◽  
Author(s):  
Zhi-jian Wang ◽  
Jian-she Zheng ◽  
Lu-lu Li ◽  
Shuai Luo

The three-dimensional flow physical model of any stage of the 20BZ4 multistage centrifugal pump is built which includes inlet region, impeller flow region, guide-vane flow region and exit region. The three-dimensional unsteady turbulent flow numerical model is created based on Navier-Stoke solver and standardk-εturbulent equations. The method of multireference frame (MRF) and SIMPLE algorithm are used to simulate the flow in multistage centrifugal pump based on FLUENT software. The distributions of relative velocity, absolute velocity, static pressure, and total pressure in guide vanes and impellers under design condition are analyzed. The simulation results show that the flow in impeller is mostly uniform, without eddy, backflow, and separation flow, and jet-wake phenomenon appears only along individual blades. There is secondary flow at blade end and exit of guide vane. Due to the different blade numbers of guide vane and impeller, the total pressure distribution is asymmetric. This paper also simulates the flow under different working conditions to predict the hydraulic performances of centrifugal pump and external characteristics including flow-lift, flow-shaft power, and flow-efficiency are attained. The simulation results are compared with the experimental results, and because of the mechanical losses and volume loss ignored, there is a little difference between them.


1996 ◽  
Author(s):  
Steven L. Puterbaugh ◽  
William W. Copenhaver ◽  
Chunill Hah ◽  
Arthur J. Wennerstrom

An analysis of the effectiveness of a three-dimensional shock loss model used in transonic compressor rotor design is presented. The model was used during the design of an aft-swept, transonic compressor rotor. The demonstrated performance of the swept rotor, in combination with numerical results, is used to determine the strengths and weaknesses of the model. The numerical results were obtained from a fully three-dimensional Navier-Stokes solver. The shock loss model was developed to account for the benefit gained with three-dimensional shock sweep. Comparisons with the experimental and numerical results demonstrated that shock loss reductions predicted by the model due to the swept shock induced by the swept leading edge of the rotor were exceeded. However, near the tip the loss model under-predicts the loss because the shock geometry assumed by the model remains swept in this region while the numerical results show a more normal shock orientation. The design methods and the demonstrated performance of the swept rotor is also presented. Comparisons are made between the design intent and measured performance parameters. The aft-swept rotor was designed using an inviscid axisymmetric streamline curvature design system utilizing arbitrary airfoil blading geometry. The design goal specific flow rate was 214.7 kg/sec/m2 (43.98 lbm/sec/ft2), the design pressure ratio goal was 2.042, and the predicted design point efficiency was 94.0. The rotor tip sped was 457.2 m/sec (1500 ft/sec). The design flow rate was achieved while the pressure ratio fell short by 0.07. Efficiency was 3 points below prediction, though at a very high 91 percent. At this operating condition the stall margin was 11 percent.


Author(s):  
S. M. Miner ◽  
R. D. Flack ◽  
P. E. Allaire

Two dimensional potential flow was used to determine the velocity field within a laboratory centrifugal pump. In particular, the finite element technique was used to model the impeller and volute simultaneously. The rotation of the impeller within the volute was simulated by using steady state solutions with the impeller in 10 different angular orientations. This allowed the interaction between the impeller and the volute to develop naturally as a result of the solution. The results for the complete pump model showed that there are circumferential asymmetries in the velocity field, even at the design flow rate. Differences in the relative velocity components were as large as 0.12 m/sec for the radial component and 0.38 m/sec for the tangential component, at the impeller exit. The magnitude of these variations was roughly 25% of the magnitude of the average radial and tangential velocities at the impeller exit. These asymmetries were even more pronounced at off design flow rates. The velocity field was also used to determine the location of the tongue stagnation point and to calculate the slip within the impeller. The stagnation point moved from the discharge side of the tongue to the impeller side of the tongue, as the flow rate increased from below design flow to above design flow. At design flow, values of slip ranged from 0.96 to 0.71, from impeller inlet to impeller exit. For all three types of data (velocity profiles, stagnation point location, and slip factor) comparison was made to laser velocimeter data, taken for the same pump. At the design flow, the computational and experimental results agreed to within 17% for the velocity magnitude, and 2° for the flow angle. The stagnation point locations coincided for the computational and experimental results, and the values for slip agreed to within 10%.


Water ◽  
2019 ◽  
Vol 12 (1) ◽  
pp. 126
Author(s):  
Houlin Liu ◽  
Ruichao Xia ◽  
Kai Wang ◽  
Yucheng Jing ◽  
Xianghui He

Experimental measurements to analyze the pressure fluctuation performance of a centrifugal pump with a vaned-diffuser, which its specific speed is 190. Results indicate that the main cause of pressure fluctuation is the rotor-stator interference at the impeller outlet. The head of the pump with vaned-diffuser at the design flow rate is 15.03 m, and the efficiency of the pump with a vaned-diffuser at the design flow rate reaches 71.47%. Pressure fluctuation decreases gradually with increasing distance from the impeller outlet. Along with the increase of the flow rate, amplitude of pressure fluctuation decreases. The amplitude of pressure fluctuation at the measuring points near the diffusion section of the pump body is larger than other measuring points. The variation tendency of pressure fluctuation at P1–P10 is the same, while there are wide frequency bands with different frequencies. The dominant frequency of pressure fluctuation is the blade passing frequency. The rotor-stator interference between the impeller and the vaned-diffuser gives rise to the main signal source of pressure fluctuation.


2020 ◽  
Vol 34 (26) ◽  
pp. 2050286
Author(s):  
Fen Lai ◽  
Xiangyuan Zhu ◽  
Yongqiang Duan ◽  
Guojun Li

The performance and service life of centrifugal pumps can be influenced by the clocking effect. In this study, 3D numerical calculations based on the k-omega shear stress transport model are conducted to investigate the clocking effect in a centrifugal pump. Time-averaged behavior and transient behavior are analyzed. Results show that the optimum diffuser installation angle in the centrifugal pump is [Formula: see text] due to the minimum total pressure loss and radial force acting on the impeller. Total pressure loss, particularly in the volute, is considerably influenced by the clocking effect. The difference in total pressure loss in the volute at different clocking positions is 2.75 m under the design flow rate. The large total pressure loss in the volute is primarily caused by the large total pressure gradient within the vicinity of the volute tongue. The radial force acting on the impeller is also considerably affected by the clocking effect. When the diffuser installation angle is [Formula: see text], flow rate fluctuations in the volute and impeller passage are minimal, and flow rate distribution in the diffuser passage is more uniform than those in other diffuser installation angles. Moreover, static pressure fluctuations in the impeller midsection and the diffuser inlet section are at the minimum value. These phenomena explain the minimum radial force acting on the impeller. The findings of this study can provide a useful reference for the design of centrifugal pumps.


1991 ◽  
Author(s):  
Ronald D. Flack ◽  
Steven M. Miner ◽  
Ronald J. Beaudoin

Turbulence profiles were measured in a centrifugal pump with an impeller with backswept blades using a two directional laser velocimeter. Data presented includes radial, tangential, and cross product Reynolds stresses. Blade to blade profiles were measured at four circumferential positions and four radii within and one radius outside the four bladed impeller. The pump was tested in two configurations; with the impeller running centered within the volute, and with the impeller orbiting with a synchronous motion (ε/r2 = 0.016). Flow rates ranged from 40% to 106% of the design flow rate. Variation in profiles among the individual passages in the orbiting impeller were found. For several regions the turbulence was isotropic so that the cross product Reynolds stress was low. At low flow rates the highest cross product Reynolds stress was near the exit. At near design conditions the lowest cross product stress was near the exit, where uniform flow was also observed. Also, near the exit of the impeller the highest turbulence levels were seen near the tongue. For the design flow rate, inlet turbulence intensities were typically 9% and exit turbulence intensities were 6%. For 40% flow capacity the values increased to 18% and 19%, respectively. Large local turbulence intensities correlated with separated regions. The synchronous orbit did not increase the random turbulence, but did affect the turbulence in the individual channels in a systematic pattern.


2019 ◽  
Vol 11 (3) ◽  
pp. 168781401982590 ◽  
Author(s):  
Kai Wang ◽  
Yu-cheng Jing ◽  
Xiang-hui He ◽  
Hou-lin Liu

In order to enhance the efficiency of centrifugal pump, the structure of a centrifugal pump with vaned diffuser, whose specific speed is 190, was numerically improved by trimming back-blades of impeller and smoothing sharp corner in annular chamber. The energy performance, the internal flow field, the axial force, the radial force, and the pressure pulsation of the pump were analyzed. Results show that efficiency of the improving scheme 1 under the design flow rate is 77.47%, which can balance 69.82% of the axial force, while efficiency of the improving scheme 2 under the design flow rate is the maximum, which could still balance 62.74% of the axial force. The pressure pulsations of the improving scheme 2 at the typical monitoring points are less than that of the improving scheme 1 and the original scheme. The difference of the radial force peak between the improving scheme 1 and the improving scheme 2 is very small. The vector distributions of the radial force of the improving scheme 1 and the improving scheme 2 are more uniform than that of the original scheme. Considering the efficiency, pressure pulsation, and axial force, experiment measurements on the improving scheme 2 were carried out to verify the effectiveness of the improvement result. Results of energy performance experiment show that efficiency of the improving scheme 2 under the design flow rate is 76.48%, which is 5.26 percentage points higher than that of the original scheme.


Sign in / Sign up

Export Citation Format

Share Document