scholarly journals Post-Voltage-Boost Circuit-Supported Single-Ended Class-B Amplifier for Piezoelectric Transducer Applications

Sensors ◽  
2020 ◽  
Vol 20 (18) ◽  
pp. 5412
Author(s):  
Jungsuk Kim ◽  
Kiheum You ◽  
Hojong Choi

Piezoelectric transducers are important devices that are triggered by amplifier circuits in mobile ultrasound systems. Therefore, amplifier performance is vital because it determines the acoustic piezoelectric transducer performances. Particularly, mobile ultrasound applications have strict battery performance and current consumption requirements; hence, amplifier devices should exhibit good efficiency because the direct current (DC) voltage in the battery are provided to the supply voltages of the amplifier, thus limiting the maximum DC drain voltages of the main transistors in the amplifier. The maximum DC drain voltages are related with maximum output power if the choke inductor in the amplifier is used. Therefore, a need to improve the amplifier performance of piezoelectric transducers exists for mobile ultrasound applications. In this study, a post-voltage-boost circuit-supported class-B amplifier used for mobile ultrasound applications was developed to increase the acoustic performance of piezoelectric transducers. The measured voltage of the post-voltage-boost circuit-supported class-B amplifier (62 VP-P) is higher than that of only a class-B amplifier (50 VP-P) at 15 MHz and 100 mVP-P input. By performing the pulse-echo measurement test, the echo signal with the post-voltage-boost circuit-supported class-B amplifier (10.39 mVP-P) was also noted to be higher than that with only a class-B amplifier (6.15 mVP-P). Therefore, this designed post-voltage-boost circuit can help improve the acoustic amplitude of piezoelectric transducers used for mobile ultrasound applications.

Sensors ◽  
2020 ◽  
Vol 20 (21) ◽  
pp. 6244 ◽  
Author(s):  
Kiheum You ◽  
Hojong Choi

Piezoelectric transducers are triggered by the output voltage signal of a transmit voltage amplifier (TVA). In mobile ultrasound instruments, the sensitivity of piezoelectric transducers is a critical parameter under limited power supply from portable batteries. Therefore, the enhancement of the output voltage amplitude of the amplifier under limited power supply could increase the sensitivity of the piezoelectric transducer. Several-stage TVAs are used to increase the voltage amplitude. However, inter-stage design issues between each TVA block may reduce the voltage amplitude and bandwidth because the electronic components of the amplifier are nonlinearly operated at the desired frequency ranges. To compensate for this effect, we propose a novel inter-stage output voltage amplitude improvement (OVAI) circuit integrated with a class-B TVA circuit. We performed fundamental A-mode pulse-echo tests using a 15-MHz immersion-type piezoelectric transducer to verify the design. The echo amplitude and bandwidth when using an inter-stage OVAI circuit integrated with a class-B TVA circuit (696 mVPP and 29.91%, respectively) were higher than those obtained when using only the class-B TVA circuit (576 mVPP and 24.21%, respectively). Therefore, the proposed OVAI circuit could be beneficial for increasing the output amplitude of the class-B TVA circuit for mobile ultrasound machines.


Sensors ◽  
2019 ◽  
Vol 19 (2) ◽  
pp. 287 ◽  
Author(s):  
Hojong Choi

Portable ultrasound systems typically suffer from unwanted heat and limited battery life, resulting in reduced system performance or the applicable number of piezoelectric transducer elements. This can be a bottleneck in widely used portable ultrasound systems. Class-A power amplifiers are typically used in portable ultrasound systems. However, unwanted heat dissipation needs to be reduced by using large cooling fans and heat pipe structures. To reduce unwanted heat, class-B power amplifiers may be a possible solution. However, the non-linearity of class-B power amplifiers could limit their integration with piezoelectric transducers because non-linearity in the high-voltage output of the power amplifiers deteriorates the sensitivity of portable ultrasound systems. To improve the linearity of the power amplifier, we developed prelinearized class-B power amplifiers for piezoelectric transducers and portable ultrasound systems. To verify our proposed method, we compared the performances of class-B and prelinearized class-B power amplifiers in their pulse-echo responses. Therefore, prelinearized class-B power amplifiers are a possible solution to produce better echo signal performance in piezoelectric transducers and portable ultrasound systems.


2016 ◽  
Vol 10 (1) ◽  
pp. 29-36
Author(s):  
Chun-Yi Zheng ◽  
Wen-Jung Chiang ◽  
Yeong-Lin Lai ◽  
Edward Y. Chang ◽  
Shen-Li Chen ◽  
...  

GaAs power metal-semiconductor field-effect transistors (MESFETs) were fabricated using direct double silicon (Si) ion implantation technology for wireless communication applications. A 150-µm MESFET had a saturation drain current of 238 mA/mm after Si3N4passivation. A 15-mm MESFET, when measured under a class-AB condition with a biased drain voltage of 3.4 V and a quiescent drain current of 600 mA, delivered a maximum output power (Pout) of 31.1 dBm and a maximum power-added efficiency (PAE) of 58.0% at a frequency of 1.88 GHz. The MESFET exhibited aPoutof 29.2 dBm with a PAE of 45.0% at the 1-dB gain compression point. The MESFET, when measured under a deep class-B condition with a biased drain voltage of 4.7 V and a quiescent drain current of 50 mA, achieved a maximumPoutof 33.1 dBm and a maximum PAE of 55.9% at 1.88 GHz. The MESFET operating at 4.7 V and 1.88 GHz exhibited aP1dBof 31.8 dBm and an associated PAE of 47.1% at the 1-dB gain compression point. When tested by IS-95 code-division multiple access (CDMA) standard signals and biased at 4.7 V under the deep class-B condition, the MESFET with aPoutof 28 dBm demonstrated an adjacent channel power rejection (ACPR) of –31.2 dBc at +1.25 MHz apart from the 1.88 GHz center frequency and –45.7 dBc at +2.25 MHz.


Author(s):  
X. Zhang ◽  
Y. Pan ◽  
T.T. Meek

Industrial microwave heating technology has emerged as a new ceramic processing technique. The unique advantages of fast sintering, high density, and improved materials properties makes it superior in certain respects to other processing methods. This work presents the structure characterization of a microwave sintered ceramic matrix composite.Commercial α-alumina powder A-16 (Alcoa) is chosen as the matrix material, β-silicon carbide whiskers (Third Millennium Technologies, Inc.) are used as the reinforcing element. The green samples consisted of 90 vol% Al2O3 powder and 10 vol% ultrasonically-dispersed SiC whiskers. The powder mixture is blended together, and then uniaxially pressed into a cylindrical pellet under a pressure of 230 MPa, which yields a 52% green density. The sintering experiments are carried out using an industry microwave system (Gober, Model S6F) which generates microwave radiation at 2.45 GHz with a maximum output power of 6 kW. The composites are sintered at two different temperatures (1550°C and 1650°C) with various isothermal processing time intervals ranging from 10 to 20 min.


2020 ◽  
pp. 17-27
Author(s):  
А.А. Шелухин

In this article, the analysis of the acoustic path during the ultrasonic pulse echo testing of the rail head in production is carried out. The influence of the parameters of the applied piezoelectric transducers on the distribution of sensitivity for the sounding scheme used in the existing installations is estimated and the real sensitivity of detecting defects of the «non-metallic inclusion» type is estimated.


Catalysts ◽  
2021 ◽  
Vol 11 (4) ◽  
pp. 508
Author(s):  
Kui You ◽  
Zihan Zhou ◽  
Chao Gao ◽  
Qiao Yang

Biochar is a kind of carbon-rich material formed by pyrolysis of biomass at high temperature in the absence or limitation of oxygen. It has abundant pore structure and a large surface area, which could be considered the beneficial characteristics for electrodes of microbial electrochemical systems. In this study, reed was used as the raw material of biochar and six biochar-based electrode materials were obtained by three methods, including one-step biochar cathodes (BC 800 and BC 700), biochar/polyethylene composite cathodes (BP 5:5 and BP 6:4), and biochar/polyaniline/hot-melt adhesive composite cathode (BPP 5:1:4 and BPP 4:1:5). The basic physical properties and electrochemical properties of the self-made biochar electrode materials were characterized. Selected biochar-based electrode materials were used as the cathode of sediment microbial electrochemical reactors. The reactor with pure biochar electrode (BC 800) achieves a maximum output power density of 9.15 ± 0.02 mW/m2, which increases the output power by nearly 80% compared with carbon felt. When using a biochar/polyaniline/hot-melt adhesive (BPP 5:1:4) composite cathode, the output power was increased by 2.33 times. Under the premise of ensuring the molding of the material, the higher the content of biochar, the better the electrochemical performance of the electrodes. The treatment of reed powder before pyrolysis is an important factor for the molding of biochar. The one-step molding biochar cathode had satisfactory performance in sediment microbial electrochemical systems. By exploring the biochar-based electrode, waste biomass could be reused, which is beneficial for the environment.


Sensors ◽  
2020 ◽  
Vol 20 (24) ◽  
pp. 7334
Author(s):  
Seongwoog Oh ◽  
Jungsuek Oh

This paper proposes a novel design for a chip-on-probe with the aim of overcoming the heat dissipation effect during brain stimulations using modulated microwave signals. The temperature of the stimulus chip during normal operation is generally 40 °C–60 °C, which is sufficient to cause unintended temperature effects during stimulation. This effect is particularly fatal in brain stimulation applications that require repeated stimulation. This paper proposes, for the first time, a topology that vertically separates the stimulus chip generating the stimulus signal and the probe delivering the signal into the brain to suppress the heat transfer while simultaneously minimizing the radio frequency (RF) transmission loss. As the proposed chip-on-probe should be attached to the head of a small animal, an auxiliary board with a heat sink was carefully designed considering the weight that does not affect the behavior experiment. When the transition structures are properly designed, a heat sink can be mounted to maximize the cooling effect, reducing the temperature by more than 13 °C in a simulation when the heat generated by the chip is transferred to the brain, while the transition from the chip to the probe experiences a loss of 1.2 dB. Finally, the effectiveness of the proposed design is demonstrated by fabricating a chip with the 0.28 μm silicon-on-insulator (SOI) complementary metal–oxide–semiconductor (CMOS) process and a probe with a RT6010 printed-circuit board (PCB), showing a temperature reduction of 49.8 °C with a maximum output power of 11 dBm. In the proposed chip-on-probe device, the temperature formed in the area in contact with the brain is measured at 31.1 °C.


Energies ◽  
2021 ◽  
Vol 14 (2) ◽  
pp. 391
Author(s):  
Nan Wu ◽  
Yuncheng He ◽  
Jiyang Fu ◽  
Peng Liao

In this paper a novel hybrid piezoelectric and electromagnetic energy harvester for civil engineering low-frequency sloshing environment is reported. The architecture, fabrication and characterization of the harvester are discussed. The hybrid energy harvester is composed of a permanent magnet, copper coil, and PVDF(polyvinylidene difluoride) piezoelectric film, and the upper U-tube device containing a cylindrical fluid barrier is connected to the foundation support plate by a hinge and spring. The two primary means of energy collection were through the vortex street, which alternately impacted the PVDF piezoelectric film through fluid shedding, and the electromotive force (EMF) induced by changes in the magnetic field position in the conducting coil. Experimentally, the maximum output power of the piezoelectric transformer of the hybrid energy harvester was 2.47 μW (circuit load 270 kΩ; liquid level height 80 mm); and the maximum output power of the electromagnetic generator was 2.72 μW (circuit load 470 kΩ; liquid level height 60 mm). The low-frequency sloshing energy collected by this energy harvester can drive microsensors for civil engineering monitoring.


Molecules ◽  
2021 ◽  
Vol 26 (11) ◽  
pp. 3460
Author(s):  
Jingcheng Shang ◽  
Yizhou Liu ◽  
Shengzhi Zhao ◽  
Yuefeng Zhao ◽  
Yuzhi Song ◽  
...  

We experimentally investigate the formation of various pulses from a thulium–holmium (Tm–Ho)-codoped nonlinear polarization rotation (NPR) mode-locking fiber oscillator. The ultrafast fiber oscillator can simultaneously operate in the noise-like and soliton mode-locking regimes with two different emission wavelengths located around 1947 and 2010 nm, which are believed to be induced from the laser transition of Tm3+ and Ho3+ ions respectively. When the noise-like pulse (NLP) and soliton pulse (SP) co-exist inside the laser oscillator, a maximum output power of 295 mW is achieved with a pulse repetition rate of 19.85-MHz, corresponding to a total single pulse energy of 14.86 nJ. By adjusting the wave plates, the fiber oscillator could also deliver the dual-NLPs or dual-SPs at dual wavelengths, or single NLP and single SP at one wavelength. The highest 61-order harmonic soliton pulse and 33.4-nJ-NLP are also realized respectively with proper design of the fiber cavity.


Sign in / Sign up

Export Citation Format

Share Document