scholarly journals Molecularly Imprinted Polymer-Based Sensors for Priority Pollutants

Sensors ◽  
2021 ◽  
Vol 21 (7) ◽  
pp. 2406
Author(s):  
Mashaalah Zarejousheghani ◽  
Parvaneh Rahimi ◽  
Helko Borsdorf ◽  
Stefan Zimmermann ◽  
Yvonne Joseph

Globally, there is growing concern about the health risks of water and air pollution. The U.S. Environmental Protection Agency (EPA) has developed a list of priority pollutants containing 129 different chemical compounds. All of these chemicals are of significant interest due to their serious health and safety issues. Permanent exposure to some concentrations of these chemicals can cause severe and irrecoverable health effects, which can be easily prevented by their early identification. Molecularly imprinted polymers (MIPs) offer great potential for selective adsorption of chemicals from water and air samples. These selective artificial bio(mimetic) receptors are promising candidates for modification of sensors, especially disposable sensors, due to their low-cost, long-term stability, ease of engineering, simplicity of production and their applicability for a wide range of targets. Herein, innovative strategies used to develop MIP-based sensors for EPA priority pollutants will be reviewed.

2021 ◽  
pp. 54-59
Author(s):  
Md. Mahidy Hossain ◽  
Nadim Khandaker

In every aspect of Engineering more advanced, efficient and progressive solutions are required. The modern age of science requires innovative minds. The field of environmental engineering is also advancing with modern science and technology innovations. Measuring of methane concentration and flow rate is nothing new, yet a complicated process. The need for more accurate measurement is a necessity in proper operation of bio digesters for methane generation. The traditional process of the measuring methane content in biogas is time consuming yet complicated. The need for development and application of methane measurement techniques is not only limited to biogas but has other monitoring value as well in other health and safety applications in built environments. Winsen Electronics and Hanwei Electronics are two of the leading sensor-manufactures of China who are providing a wide range of gas detecting sensors that are locally available in Bangladesh and yet has not been applied to methane content measurement in biogas operations. In This paper we are reporting on the application of a purpose-built propane, butane detector for methane gas detection within the range of accuracy for it to be applied in methane detection in a biogas stream. This paper, reports on application and calibration of the methane detecting sensor MQ-4 with promising result. Based on the study we postulate that the sensor can be used to detect methane for an on-line monitoring of many environmental, industrial purposes such as bio digesters, integrated waste management facility. The cost of fabrication of the sensor system is only $18 making it a viable sensor with respect to cost for application in Bangladesh.


1994 ◽  
Vol 56 (1-4) ◽  
pp. 9-11 ◽  
Author(s):  
D.L. Wilson ◽  
C.S. Dudney ◽  
R.B. Gammage

Abstract To date, the US Environmental Protection Agency has not published guidance for radon testing, diagnostics, or mitigation within large, non-residential buildings. Current research indicates that large buildings may contain construction features or mechanical systems that could inhibit the installation or operation of a mitigation system. Health and safety issues such as asbestos and fire codes may further interfere with the installation process. Studies also show that elevated radon can be restricted to a particular area or room within a building and not be uniformly distributed. A four-step, sequential protocol has been developed to address these issues and facilitate large building radon mitigation.


Materials ◽  
2021 ◽  
Vol 14 (22) ◽  
pp. 7078
Author(s):  
Mariusz Marć ◽  
Marta Bystrzanowska ◽  
Katarzyna Pokajewicz ◽  
Marek Tobiszewski

In the case of quantitative and qualitative analysis of pesticides in environmental and food samples, it is required to perform a sample pre-treatment process. It allows to minimalize the impact of interferences on the final results, as well as increase the recovery rate. Nowadays, apart from routinely employed sample preparation techniques such as solid-phase extraction (SPE) or solid-phase microextraction (SPME), the application of molecularly imprinted polymers (MIPs) is gaining greater popularity. It is mainly related to their physicochemical properties, sorption capacity and selectivity, thermo-mechanical resistance, as well as a wide range of polymerization techniques allowing to obtain the desired type of sorption materials, adequate to a specific type of pesticide. This paper targets to summarize the most popular and innovative strategies since 2010, associated with the MIPs synthesis and analytical procedures for pesticides determination in environmental and food samples. Application of multi-criteria decision analysis (MCDA) allows for visualization of the most beneficial analytical procedures in case of changing the priority of each step of analysis (MIPs synthesis, sample preparation process—pesticides extraction, chromatographic analysis) bearing in mind metrological and environmental issues.


Author(s):  
Alessandra Sanson ◽  
Edoardo Roncari ◽  
Stefano Boldrini ◽  
Patrizia Mangifesta ◽  
Lioudmila Doubova

Gadolina doped ceria (GDC) is a promising electrolyte for intermediate temperature solid oxide fuel cells (IT-SOFC). Dense layers of this material can be economically deposited by screen printing. However, the inks for this technique generally use organic compounds that can raise health and safety issues, as well as economical issues. In order to obtain a low-cost alternative to the generally accepted organic-based ink, four different blends of binders were considered to prepare water-based GDC inks. The systems were deposited onto green NiO/GDC anodes produced by tape casting and treated at 1673 K for 4 h. By choosing the right combination of solvents and binders, it was possible to obtain a dense crack-free film of GDC from a water-based system.


2020 ◽  
Vol 16 (3) ◽  
pp. 196-207 ◽  
Author(s):  
Yeşeren Saylan ◽  
Adil Denizli

Introduction: A molecular imprinting is one of the fascinating modification methods that employ molecules as targets to create geometric cavities for recognition of targets in the polymeric matrix. This method provides a broad versatility to imprint target molecules with different size, three-dimensional structure and physicochemical features. In contrast to the complex and timeconsuming laboratory surface modification procedures, this method offers a rapid, sensitive, inexpensive, easy-to-use, and selective approach for the diagnosis, screening and monitoring disorders. Owing to their unique features such as high selectivity, physical and chemical robustness, high stability, low-cost and reusability of this method, molecularly imprinted polymers have become very attractive materials and been applied in various applications from separation to detection. Background: The aims of this review are structured according to the fundamentals of molecularly imprinted polymers involving essential elements, preparation procedures and also the analytical applications platforms. Finally, the future perspectives to increase the development of molecularly imprinted platforms. Methods: A molecular imprinting is one of the commonly used modification methods that apply target as a recognition element itself and provide a wide range of versatility to replica other targets with a different structure, size, and physicochemical features. A rapid, easy, cheap and specific recognition approach has become one of the investigation areas on, especially biochemistry, biomedicine and biotechnology. In recent years, several technologies of molecular imprinting method have gained prompt development according to continuous use and improvement of traditional polymerization techniques. Results: The molecularly imprinted polymers with excellent performances have been prepared and also more exciting and universal applications have been recognized. In contrast to the conventional methods, the imprinted systems have superior advantages including high stability, relative ease and low cost of preparation, resistance to elevated temperature, and pressure and potential application to various target molecules. In view of these considerations, molecularly imprinted systems have found application in various fields of analytical chemistry including separation, purification, detection and spectrophotometric systems. Conclusion: Recent analytical methods are reported to develop the binding kinetics of imprinted systems by using the development of other technologies. The combined platforms are among the most encouraging systems to detect and recognize several molecules. The diversity of molecular imprinting methods was overviewed for different analytical application platforms. There is still a requirement of more knowledge on the molecular features of these polymers. A next step would further be the optimization of different systems with more homogeneous and easily reachable recognition sites to reduce the laborious in the accessibility in the three-dimensional polymeric materials in sufficient recognition features and also better selectivity and sensitivity for a wide range of molecules.


Micromachines ◽  
2019 ◽  
Vol 10 (11) ◽  
pp. 766 ◽  
Author(s):  
Yeşeren Saylan ◽  
Adil Denizli

Fast progress has been witnessed in the field of microfluidic systems and allowed outstanding approaches to portable, disposable, low-cost, and easy-to-operate platforms especially for monitoring health status and point-of-care applications. For this purpose, molecularly imprinted polymer (MIP)-based microfluidics systems can be synthesized using desired templates to create specific and selective cavities for interaction. This technique guarantees a wide range of versatility to imprint diverse sets of biomolecules with different structures, sizes, and physical and chemical features. Owing to their physical and chemical robustness, cost-friendliness, high stability, and reusability, MIP-based microfluidics systems have become very attractive modalities. This review is structured according to the principles of MIPs and microfluidic systems, the integration of MIPs with microfluidic systems, the latest strategies and uses for point-of-care applications and, finally, conclusions and future perspectives.


Technologies ◽  
2019 ◽  
Vol 7 (4) ◽  
pp. 75
Author(s):  
Stefan Lundgaard ◽  
Soon Ng ◽  
Damien Cahill ◽  
Johan Dahlberg ◽  
Dong Ruan ◽  
...  

Primers are used to reliably initiate a secondary explosive in a wide range of industrial and defence applications. However, established primer technologies pose both direct and indirect risks to health and safety. This review analyses a new generation of primer materials and ignition control mechanisms that have been developed to address these risks in firearms. Electrically or optically initiated metal, oxide and semiconductor-based devices show promise as alternatives for heavy metal percussive primers. The prospects for wider use of low-cost, safe, reliable and non-toxic primers are discussed in view of these developments.


2021 ◽  
Author(s):  
Zilong Chen ◽  
Zhaowei Zhu ◽  
Liting Huang ◽  
Chuantong Cheng

Abstract Photodetectors (PDs) are the core component of multiple commercial optical sensing systems. Currently, the detection of ultra-weak ultraviolet (UV) optical signals is becoming increasingly important for wide range of applications in civil and military industries. Due to its wide band gap, low cost, and long-term stability, titanium dioxide (TiO2) is an attractive material for UV photodetection. A kind of low-cost TiO2 nanomaterial (named as P25) manufactured by flame hydrolysis is an easily available commercial material. However, a low-cost and high-sensitivity UV PD based on P25 has not been achieved until now. Here, a hybrid UV PD with monolayer CVD graphene covered by a thin film of P25 quantum dots was prepared for the first time, and its responsivity was approximately 105 A/W at 365 nm wavelength. The response time and recovery time of the UV PD were 32.6 s and 34 s, respectively. Strong light absorption and photocontrolled oxygen adsorption of the P25 layer resulted in high UV sensitivity. The UV PDs proposed in this work have great potential for commercialization due to their low cost and high sensitivity.


2020 ◽  
Author(s):  
Adnan Masic ◽  
Dzevad Bibic ◽  
Boran Pikula ◽  
Almir Blazevic ◽  
Jasna Huremovic ◽  
...  

Abstract. In this paper we evaluate characteristics of three optical particulate matter sensors/sizers (OPS): high-end spectrometer 11-D (Grimm, Germany), low-cost sensor OPC-N2 (Alphasense, United Kingdom) and in-house developed MAQS which is based on another low-cost sensor – PMS5003 (Plantower, China), under realistic conditions of strong and mild urban pollution. Results were compared against a reference gravimetric system, based on Gemini (Dadolab, Italy), 2.3 m3/h air sampler, with two channels (simultaneously measuring PM2.5 and PM10 concentrations). The measurements were performed in Sarajevo, the capital of Bosnia-Herzegovina, from December 2019 until May 2020. This interval is divided into period 1 – strong pollution (December 2019–March 2020) and period 2 – mild pollution (March 2020–May 2020). The city of Sarajevo is one of the most polluted cities in Europe in terms of aerosols: the average concentration of PM2.5 during the period 1 was 83 μg/m3, with daily aveverage values exceeding 500 μg/m3. During period 2, the average concentration of PM2.5 was 20 μg/m3. These conditions represent a good opportunity to test optical devices against reference instrument in a wide range of ambient particulate matter (PM) concentrations. The effect of an in-house developed diffusion dryer for 11-D is discussed as well. In order to analyze the mass distribution of aerosols, a scanning mobility particle sizer (SMPS) spectrometer, which together with the 11-D spectrometer gives the full spectrum from nanoparticles of diameter 10 nm to coarse particles of diameter 35 μm, was used. All tested devices showed excellent correlation with the reference instrument in period 1, with R2 values between 0.90 and 0.99 for daily average PM concentrations. However, in period 2, where the range of concentrations was much narrower, R2 values decreased significantly, to values from 0.28 to 0.92. We have also included results of a 13.5 month long-term comparison of our MAQS sensor with a nearby beta attenuation monitor (BAM) 1020 (Met One Instruments, USA) operated by the United States Environmental Protection Agency (US EPA), which showed similar correlation and no observable change of performance over time.


2018 ◽  
Vol 37 (2) ◽  
Author(s):  
Francis Merlin Melataguia Tchieno ◽  
Ignas Kenfack Tonle

AbstractAn almost exhaustive overview of the determination and remediation ofp-nitrophenol (p-NP)-contaminated media is herein presented.p-NP is one of the priority pollutants on the U.S. Environmental Protection Agency list. This is becausep-NP is either a precursor or a derivative of a good number of pollutants. It is itself very carcinogenic and tends to persist in water and soil. This has prompted the development of a wide range of analytical tools by researchers for its determination and eventual removal from contaminated sites. These include electrochemical methods with many electrode modifiers and electroanalytical procedures developed for the detection/quantification ofp-NP in contaminated environments. Also, chromatographic andp-NP uptake techniques, particularly adsorption onto various adsorbents (ranging from natural to synthetic), are reviewed. The use of microorganisms for the bioremediation ofp-NP-contaminated samples and sites has equally been largely studied and is herein overviewed, not forgetting advanced oxidative processes.


Sign in / Sign up

Export Citation Format

Share Document