scholarly journals Experimental Study on Seismic Behavior of Masonry Walls Strengthened by Reinforced Mortar Cross Strips

2019 ◽  
Vol 11 (18) ◽  
pp. 4866 ◽  
Author(s):  
Dong ◽  
Sui ◽  
Jiang ◽  
Zhou

Due to the poor seismic performance, strengthening of masonry structures is always a significant problem worthy to study. It has been proven that the bearing capacity of existing masonry buildings can be enhanced greatly with efficient strengthening measures. An experimental program was conducted to investigate seismic performance of un-reinforced masonry (URM) walls strengthened b,y reinforced mortar (RM) cross strips. Eleven walls were tested under horizontal low-cyclic load, simultaneously with a vertical constant load on the top face. Three URM walls were tested as reference. The other eight walls were externally strengthened with 40 and 60 mm thick of RM cross strips on one or both faces. Test results showed that externally strengthening with RM cross strips was an efficient way to enhance the seismic performance of URM walls. The failure modes were divided into shear failure and shear-compression failure. All the tested walls did not collapse until the test ended, while many diagonal cracks and few vertical cracks appeared on mortar strips. After strengthening, the shear capacity of the strengthened walls increased by at least 38.2%, and the reinforcement ratio was noted to be the key factor to influence the shear capacity with positive correlation. Besides, RM cross strips did improve deformation capacity greatly.

2020 ◽  
pp. 136943322098165
Author(s):  
Jianyang Xue ◽  
Xin Zhang ◽  
Xiaojun Ke

This paper mainly focused on the seismic performance and shear calculation method of steel reinforced high-strength concrete (SRHC) columns with rectangular helical hoops. An experimental investigation was performed in this paper. Eleven SRHC columns with rectangular helical hoops and one with ordinary hoops were constructed at the laboratory of Guangxi university. The failure modes, hysteresis loops, envelope curves, characteristic loads and displacements and cumulative damage analysis are presented and investigated. It can be seen from the test results that the failure modes of SRHC columns can be divided into three types with the shear span ratio increased, namely, shear baroclinic failure mode, flexure-shear failure mode and flexure failure mode. In addition, the specimens with rectangular helical hoops have plumper hysteretic loops. Shear span ratio is the main influencing factor of characteristic load; the axial compression ratio and concrete strength have less influence on characteristic load, while stirrup ratio has little effect on the characteristic load. Finally, a calculation method for shear capacity of SRHC columns under shear baroclinic failure and flexure-shear failure mode is proposed.


2012 ◽  
Vol 217-219 ◽  
pp. 2435-2439
Author(s):  
Ying Tao Li ◽  
Shi Yong Jiang ◽  
Bing Hong Li ◽  
Qian Hua Shi ◽  
Xian Qi Hu

An experimental program was carried out by the author to investigate the shear behavior of concrete beams reinforced with continuous FRP rectangular spirals, the main variables considered in the test were the shear reinforcement ratio and the shear span to depth ratio and the longitudinal reinforcement ratio. However, the experimental program is inadequate to gain insight into the shear behavior of the members. First, the quantities of test specimens were too small, only six beams were made and tested, the experimental database was so limited that the resultant analytical results and conclusions may not be sound enough. Second, not all the main factors that have influences on the shear behavior of the members have been treated as variables in the experimental program, such as the effective transverse compression stress and the concrete compression strength, the influences of these two factor on the shear behavior of the members were not clear yet through the experimental study. Considering the insufficient information provided by the experimental investigation, the parametric analysis of the shear behavior of the members was carried out, and a revised rotating-angle softened truss model for the shear analysis of the members was proposed as the analytical tool. Based on the proposed model, the influences of various factors on the shear capacity and shear failure modes of the members were discussed, related nonlinear analysis was carried out using the arithmetic of iteration and step approximation, and several FORTRAN codes were written accordingly. Through the experimental study and the parametric analysis, it is indicated that the shear capacity and the shear failure modes of the members are greatly influenced by three major factors, including the shear reinforcement ratio and the shear span to depth ratio and the effective transverse compression stress. The influences of the concrete compression strength and the longitudinal reinforcement ratio on the shear capacity are not noticeable comparatively. The shear capacity is little affected by the shear span to depth ratio in the case of the shear-tension failure, there is no noticeable correlation between longitudinal reinforcement ratio and the shear failure modes.


Author(s):  
Tran Xuan Vinh ◽  
Nguyen Trung Hieu ◽  
Pham Xuan Dat ◽  
Nguyen Manh Hung

Currently, RC flat slabs are being used commonly because of their advantages. Punching shear failure is one of the governing failure modes of RC flat slabs without column capital and drop panels. In this paper, the provisions for predicting the punching shear capacity of two-way reinforced concrete (RC) flat slabs without shear reinforcement including ACI 318-19, Eurocode 2 and TCVN 5574:2018 provisions are reviewed by mean of considering the influences of the main parameters (effective depth, compressive strength of concrete, loaded area, reinforcement ratio). A total of 169 test results collected from the literature were used to compare with the provisions. The aim of this study was to evaluate the level of applicability of predicting the punching shear capacity of two-way RC flat slabs according to these provisions. The comparison results indicated that the Eurocode 2 provision provides the most accurate prediction of punching shear capacity of two-way RC flat slabs.


1996 ◽  
Vol 12 (4) ◽  
pp. 761-780 ◽  
Author(s):  
A. Ghobarah ◽  
Tarek S. Aziz ◽  
Ashraf Biddah

As building codes are updated, some of the existing important structures may fall short of complying with current standards even though they may have been properly designed and constructed according to earlier codes. Many existing structures may be inadequate and may pose severe risk during seismic events. Rehabilitation measures to upgrade the capacity of these structures can be performed at some point in their useful lives especially when located in seismically active zones. A new method for improving the seismic performance of existing reinforced concrete structures is by jacketing the deficient connections using corrugated steel jackets. An experimental program was conducted to evaluate this method of rehabilitation. Corrugated steel jacketing addresses the particular weakness that is often found in existing reinforced concrete structures, namely the lack of sufficient shear reinforcement and the required confining reinforcement within the joints and in adjoining beams and columns. The performance of four reinforced concrete connections was determined experimentally. The test specimens include one connection representing existing structures, one designed according to current seismic codes and two rehabilitated connections. The test results showed satisfactory performance at high cyclic load levels and significant increase in the shear capacity and ductility of connections rehabilitated with corrugated steel jackets.


2012 ◽  
Vol 204-208 ◽  
pp. 3009-3015
Author(s):  
Bing Hong Li ◽  
Shi Yong Jiang ◽  
Qian Hua Shi ◽  
Xian Qi Hu

The failure modes and the shear capacity of concrete beams reinforced with FRP reinforcement were discussed through an experimental investigation, in which continuous FRP rectangular spirals were used for shear reinforcement, while ordinary deformed steel bars are used for longitudinal reinforcement. Six concrete beams reinforced with FRP spirals were tested, the main variables considered were the shear reinforcement ratios, the shear span to depth ratios and the longitudinal reinforcement ratios. Two concrete beams of equal shear capacity which reinforced with continuous steel rectangular spirals were also tested to compare the behavior of concrete beams reinforced with different materials of spirals. All beams were tested as simply supported members subjected to a three-point load, the span of the beams varied in terms of different shear span to depth ratios. The test results show that the shear capacity and shear failure modes are greatly influenced by the shear reinforcement ratios and the shear span to depth ratios, the shear resistance provided by steel spirals is higher than that provided by FRP spirals in the case of equal shear capacity of beams, which is attributed to the differences in material properties and may result in different shear failure types. Based on the experimental program, four mechanical models are derived to give more accurate predictions of the shear capacity of test beams, the calculation results of these models are compared with that of the existing shear formulas or equations for concrete beams reinforced with FRP stirrups or spirals. The rotating-angle softened truss model, the strut-and-tie model, the shear formulas derived from the truss-arch model and Zsutty equations are suggested through comparison.


2021 ◽  
Vol 11 (10) ◽  
pp. 4421
Author(s):  
Zhiming Zhang ◽  
Fenglai Wang

In this study, four single-story reinforced masonry shear walls (RMSWs) (two prefabricated and two cast-in-place) under reversed cyclic loading were tested to evaluate their seismic performance. The aim of the study was to evaluate the shear behavior of RMSWs with flanges at the wall ends as well as the effect of construction method. The test results showed that all specimens had a similar failure mode with diagonal cracking. However, the crack distribution was strongly influenced by the construction method. The lateral capacity of the prefabricated walls was 12% and 27% higher than that of the corresponding cast-in-place walls with respect to the rectangular and T-shaped cross sections. The prefabricated walls showed better post-cracking performance than did the cast-in-place wall. The secant stiffness of all the walls decreased rapidly to approximately 63% of the initial stiffness when the first major diagonal crack was observed. The idealized equivalent elastic-plastic system showed that the prefabricated walls had a greater displacement ductility of 3.2–4.8 than that of the cast-in-place walls with a displacement ductility value of 2.3–2.7. This proved that the vertical joints in prefabricated RMSWs enhanced the seismic performance of walls in shear capacity and ductility. In addition, the equivalent viscous damping of the specimens ranged from 0.13 to 0.26 for prefabricated and cast-in-place walls, respectively.


2013 ◽  
Vol 351-352 ◽  
pp. 1532-1536 ◽  
Author(s):  
Bin Ding ◽  
Li Jun Ouyang ◽  
Zhou Dao Lu ◽  
Wei Zhen Chen

BFRP has excellent strength, durability, thermal properties and economic cost. To test seismic performance of short columns strengthened with BFRP. Low cyclic loading test was conducted on one comparative short column and two RC short columns strengthened with BFRP. The test shows that short columns warped by BFRP show excellent failure modes, shear capacity, ductility and energy dissipation. As a new fiber reinforced plastic, BFRP has a good prospect in the area of seismic strengthening for its low cost and comprehensive mechanical properties.


Author(s):  
Zhanchong Shi ◽  
Qingtian Su ◽  
Xinyi He ◽  
Quanlu Wang ◽  
Kege Zhou ◽  
...  

<p>In order to solve the construction problem of perforating rebars’ precise location and it’s getting through the circular holes for the the conventional perfobond connector, a new type of perfobond connector with boot shaped slots was proposed. This new type perfobond connector has the advantage of convenient construction and pricise location. Three groups of push-out tests with nine specimens were carried out to study the shear capacity of the new type perfobond connector. The effect of the number and the spacing of boot shaped slots on failure modes, shear capacity, peak slip and shear stiffness were mainly studied. The test results show that the new type of perfobond connector with boot shaped slots has a high shear capacity and a good ductility, it could be widely applied on the connection between the steel and the concrete structures.</p>


2006 ◽  
Vol 324-325 ◽  
pp. 995-998
Author(s):  
Cheol Woo Park ◽  
Jong Sung Sim

Even though the application of fiber reinforced polymer (FRP) as a concrete reinforcement becomes more common with various advantages, one of the inherent shortcomings may include its brittleness and on-site fabrication and handling. Therefore, the shape of FRP products has been limited only to a straight bar or sheet type. This study suggests a new technique to use glass fiber reinforced polymer (GFRP) bars for the shear reinforcement in concrete beams, and investigates its applicability. The developed GFRP stirrup was used in the concrete instead of ordinary steel stirrups. The experimental program herein evaluates the effectiveness of the GFRP stirrups with respect to different shear reinforcing ratios under three different shear span-to-depth testing schemes. At the same shear reinforcing ratio, the ultimate loads of the beams were similar regardless the shear reinforcing materials. Once a major crack occurs in concrete, however, the failure modes seemed to be relatively brittle with GFRP stirrups. From the measured strains on the surface of concrete, the shear stresses sustained by the stirrups were calculated and the efficiency of the GFRP stirrups was shown to be 91% to 106% depending on the shear span-to-depth ratio.


2016 ◽  
Vol 78 (5-4) ◽  
Author(s):  
Tengku Anita Raja Hussin ◽  
Mohamad Iswandi Jinne ◽  
Rohana Hassan

This paper presents an experimental program for testing glued-in dowel glulam timber joints. Hundred thirty glulam specimens, each with a single glued-in rebar parallel to the grain and perpendicular to grain with different size of dowels 12mm, 16mm and 20mm were tested to evaluate the effects of anchorage length and different dowel diameter for parallel and perpendicular to the grain on pull-out strength and bond behaviour of glued-in rebar timber joints. The test results showed that the maximum load for specimen with dowel glued-in parallel to the grain given the higher maximum load than dowel glued-in perpendicular to the grain direction. Failure modes were characterized by pull out failure in the mode of adhesive-dowel, yet one sample failed in timber-adhesive mode. This might happened because the surface of the timber was burned by drilling machine during the drilling process. The pull-out was tested with different thickness grain direction with different dowel size with a rate of 2mm/min and the failure modes were observed after the testing of pull-out test. PRF is the adhesive used for the strengthening purposes. Resistance to the withdrawal of dowels glued-in perpendicularly was 44.2% to 53.5 % lower than that obtained for dowels glued-in parallel to the grain direction. The result shows that the dowel glued-in parallel to the grain given the higher maximum load than dowel glued-in perpendicular to the grain direction.