A Novel Approach of Chitosan Additive to Remove Formaldehyde from Building Materials

2011 ◽  
Vol 335-336 ◽  
pp. 1174-1180
Author(s):  
Huang Chin Wang ◽  
Sy Yuan Kang ◽  
Chao Heng Tseng ◽  
Wen Cheng Shau ◽  
Zhi Yang Chen

Formaldehyde (HCHO) which emitted from building materials, such as plywood and adhesive, is a carcinogenic substance in indoor air. Chitosan is produced from the structural element in the exoskeleton of crustaceans (such as crabs and shrimp), and has the ability to absorb HCHO. In this study, the HCHO removal efficiency by chitosan additives was evaluated for two building materials - adhesive and plywood. The experiments were performed in a small chamber based on the method of Japanese Industrial Standards (JIS) A1901 to evaluate the HCHO emission from adhesive and plywood before and after the application of chitosan additives. Both the HCHO concentration in the chamber and the HCHO emission factor of two adhesives, urea-formaldehyde (UF) resin and Poly Vinyl Acetate (PVAC) resin, were reduced from 0.02~0.21 ppm and 0.12~1.05 mg/m2h to 0~0.14 ppm and 0.12~0.63 mg/m2h after using chitosan additives. The best HCHO removal efficiency was adding 9% chitosan additives in the adhesives. The amount of absorbed HCHO is proportional to the amount of chitosan additives, and approximate 0.02 mg of HCHO can be absorbed by per mg of chitosan additive (i.e. absorption capacity 0.02 g HCHO/g Chitosan).

2011 ◽  
Vol 314-316 ◽  
pp. 273-278
Author(s):  
Yu Hua Dong ◽  
Ke Ren ◽  
Qiong Zhou

Linear low density polyethylene (LLDPE) was chemically modified with grafting maleic anhydride (MAH) monomer on its backbone by melting blending. Nano-particles SiO2 was modified by cationic surfactant hexadecyl trimethyl ammonium bromide (CTAB) and anionic surfactant sulfosalicylic acid (SSA) and added to PE coating respectively. Measurement of membrane potential showed that the coating containing modified SiO2 nano-particles had characteristic of ion selectivity. The properties of the different coatings were investigated according to relative industrial standards. Experimental results indicated that PE coating with ion selectivity had better performances, such as adhesion strength, cathodic disbonding and anti-corrosion, than those of coating without ion selectivity. Crystal structure of the coatings before and after alkali corrosion was characterized by Fourier transform infrared spectra (FTIR) and X-ray diffraction (XRD). Structure of the coating without ion selectivity was damaged by NaOH alkali solution, causing mechanical properties being decreased. And the structure of the ion selective coatings was not affected.


Buildings ◽  
2021 ◽  
Vol 11 (6) ◽  
pp. 250
Author(s):  
Chuloh Jung ◽  
Jihad Awad

Due to unprecedented urbanization, UAE had built many new residential projects with poor choices of material and ventilation. This social phenomenon is leading UAE to Sick Building Syndrome (SBS) faster than any other countries. The Dubai Municipality regulates the indoor air quality with strict stipulation, but the detailed regulations are still insufficient. The objective of this paper is to measure the indoor air quality of new residential projects in Dubai to suggest the improvement of the regulations for indoor air quality. As a methodology, a field survey was conducted to investigate the status of indoor air pollution in residential buildings. Based on the field survey data, lab experiments for building materials were conducted and a computer simulation on radon gas was conducted. The result had shown that radon gas was mainly detected in new townhouses and labor camp houses, and its concentration was found to exceed the standard. Volatile organic solvents (VOCs) and formaldehyde (CH2O) were mainly detected in showhouses and new townhouses, and the concentration distribution was about 10 times higher than that of outdoors. It was proven that emission concentration of radon gas from various building materials were detected, and the order was red clay, gypsum board, and concrete. Volatile organic solvents (VOCs) are mainly detected in oil paints and PVC floor and the radiation amount of all pollutants increased with temperature increase. In computer simulation, it was found that a new townhouse needs a grace period from 20 days to 6 months to lower the radon gas concentration by 2 pCi/L. This study will serve as a basic data to establish more detailed regulation for the building materials and improve the IAQ standards in Dubai.


2021 ◽  
Vol 11 (6) ◽  
pp. 2725
Author(s):  
Jakub Svoboda ◽  
Tomáš Dvorský ◽  
Vojtěch Václavík ◽  
Jakub Charvát ◽  
Kateřina Máčalová ◽  
...  

This article describes an experimental study aimed at investigating the potential use of recycled rubber granulate from waste tires of fractions 0/1 and 1/3 mm in cement composites as a 100% replacement for natural aggregates. The use of waste in the development and production of new building materials represents an important aspect for the sustainability and protection of the environment. This article is focused on the sound-absorbing and thermal-insulating properties of experimental cement composites based on recycled rubber from waste tires. The article describes the grain characteristics of recycled rubber, sound absorption capacity, thermal conductivity and strength characteristics. The results of this research show that the total replacement of natural aggregate with recycled rubber in cement composites is possible. Replacing natural aggregate with recycled rubber has significantly improved the thermal and acoustic properties of the prepared cement composites, however, at the same time; there was also the expected decrease in the strength characteristics due to the elasticity of rubber.


2018 ◽  
Vol 115 (3) ◽  
pp. 312 ◽  
Author(s):  
Rowaid Al-khazraji ◽  
Yaqiong Li ◽  
Lifeng Zhang

Boron (B) removal by slag refining using CaO–SiO2–CaCl2 was investigated in metallurgical-grade silicon (MG-Si) and 75 wt% Si–Sn alloy. Experiments were conducted at 1500 °C for 15 min. The microstructure was characterized before and after refining. The effects of acid leaching, basicity, and slag/Si mass ratio on B removal were investigated. Experimental results showed that acid leaching had no effect on B removal from MG-Si but had a clear effect on the refined Si–Sn alloy after slag refining. The final B concentration was highly affected by the CaO/SiO2 mass ratio with minimum value, where the content of B was reduced from 18.36 ppmw to 5.5 ppmw at the CaO/SiO2 = 1.2 for MG-Si slag refining and from 18.36 ppmw to 3.7 ppmw at CaO/SiO2 = 1.5 for 75 wt% Si–Sn alloy. Increasing the slag mass ratio by 2:1 mass ratio also increased B removal efficiency by approximately 15–20% more than an increase by 1:1.


2012 ◽  
Vol 730-732 ◽  
pp. 271-276
Author(s):  
H.R. Pakravan ◽  
M. Jamshidi ◽  
M. Latifi ◽  
F. Pacheco-Torgal

This paper compares the adhesion strength between three polymeric fibres (polypropylene (PP), nylon66 (N66) and polyacrylonitrile (PAN)) embedded in a cement paste. The specimens were prepared at a water to cement ratio (w/c) of 0.5 and tested after 7, 14 and 28 curing days. It was found that although the adhesion between the polymeric fibres to the cement matrix is an important factor, the energy absorption capacity or energy dissipation ability of the fibres, plays a more important role in the improvement of the cementitious composites fracture toughness. Scanning electron micrographs were used to characterize the fibres surface before and after the Pull-out tests.


2021 ◽  
Vol 410 ◽  
pp. 778-783
Author(s):  
Pavel V. Matyukhin ◽  
Daler I. Mirzoev

The paper presents the results of ferriferous wastes modification process research carried on the basis of JCS “Leninobad rare metals Plant” located in the Republic of Tajikistan. The wastes for the study were taken from the western tailing. The article presents the justification of the chosen wastes as a filling material in the development of new radiation protective composite building materials. The data on the initial ferriferous chemical composition of the tailing wastes and the chemical composition of the material that passed the enrichment process is presented. The study contains microphotos of ferriferous haematite raw material particles surface before and after completing the modifying process. The paper presents and describes the study of X-ray phase analysis diffractograms of enriched iron-containing wastes before and after the modification process. The current research proves that the enrichment ferriferous wastes particles modification process is possible and as a result it can be used as a filling for the development of new kinds of radioprotective composite materials.


2021 ◽  
Author(s):  
Maria C. Iglesias ◽  
Philip S. McMichael ◽  
Osei A. Asafu-Adjaye ◽  
Brian K. Via ◽  
Maria S. Peresin

Abstract Wood-based panels are commonly used as building materials for interior and exterior purposes. Their production and utilization have increased over the past decades due to the useful properties they present. Adhesive-bonded products make up to 80% of the wood alternatives on the global market, and of that, urea-formaldehyde (UF) makes up approximately 81% of the resins used. Formaldehyde-based resins are used due to their effectiveness and low cost, as well as their ease of application and lack of color. Nevertheless, their main disadvantages are the lack of tackiness and the emission of formaldehyde over time. To improve UF performance, the utilization of microfibrillated cellulose, has been demonstrated to be effective. However, more understanding on the mechanisms of the interactions is of relevant importance. In this work, we studied interfacial interactions between UF with bleached (BCNF) and unbleached (LCNF) cellulose nanofibrils using Quartz Crystal Microbalance with dissipation monitoring (QCM-D) technique observing the superior performance of lignin-containing CNF. Additionally, the surface free energies were investigated using Contact Angle Measurements (CA) showing a decrease of the values mainly when utilizing LCNF, which was later correlated with the wettability properties of the particle boards (PBs). PBs with different adhesive/CNF formulations were produced showing larger improvements when adding LCNF in terms of modulus of elasticity (MOE), modulus of rupture (MOR), and internal bonding (IB). To gain a better understanding on the interactions between CNF and UF, CNF was fully characterized in terms of morphology, chemical composition, charge density, as well as thermal and colloidal stability.


2018 ◽  
Vol 19 (4) ◽  
pp. 1066-1072
Author(s):  
Q. H. Jin ◽  
C. Y. Cui ◽  
H. Y. Chen ◽  
Y. Wang ◽  
J. F. Geng ◽  
...  

Abstract Adsorption (ADS) and dielectrophoresis (DEP) techniques were combined (ADS/DEP) to efficiently remove As(V) in industrial wastewater. Fly ash, activated carbon, corncob and plant ash were tested to determine the best adsorbent by their adsorption capacity. Plant ash showed the highest adsorption capacity compared with the others. Different parameters such as solution pH and adsorbent dose were explored. The maximum As(V) removal efficiency was 91.4% at the optimized conditions (pH 9.0, adsorbent dose 5 g/L) when the initial concentration of As(V) was 15 mg/L. With the ADS/DEP technique, the plant ash particles with adsorbed As(V) were trapped on the electrodes in a DEP device. The ADS/DEP process could increase the removal efficiency of As(V) to 94.7% at 14 V even when the initial concentration of As(V) was 15 mg/L. And the residual concentration of As(V) decreased to 0.34 mg/L after two series of the ADS/DEP process. The adsorbents before and after DEP were examined by scanning electron microscope (SEM) and energy dispersive X-ray (EDX) analysis. After the DEP process, the weight percentage of As(V) on the adsorbent surface increased to 0.96% from 0.5%. The ADS/DEP process could be a new efficient way to remove arsenic pollutant at high concentrations.


Atmosphere ◽  
2021 ◽  
Vol 12 (12) ◽  
pp. 1606
Author(s):  
Małgorzata Basińska ◽  
Michał Michałkiewicz ◽  
Katarzyna Ratajczak

Dissatisfaction with indoor air quality is common even in relatively new or renovated Polish school buildings. To improve air quality in educational buildings, portable devices have seen increased use, for which manufacturers guarantee a high level of indoor air purification. However, their optimized operation largely depends on their correct use. The aim of this article was to determine the effectiveness of air purification in a primary school using an air purification device with an analysis of the classroom indoor air quality (IAQ). Two criteria were used, microbiological and particulate matter concentration. Measurements were made before device installation and during its continuous operation, and before and after lessons on chosen days. Measurements related to IAQ did not detect clear differences in the analyzed measurement periods. For microbiological contamination, in the morning before lessons, the total count for all bacteria and microscopic fungi was definitely lower than after lessons. Comparing the periods before and after device installation, no clear tendency for reducing the bacteria count or microscopic fungi occurred during air purifier operation, nor was there any noticeable trend in the reduction of particulate matter. There was no improvement in air quality in the classrooms during the operation of the purification devices.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Prince Junior Asilevi ◽  
Patrick Boakye ◽  
Sampson Oduro-Kwarteng ◽  
Bernard Fei-Baffoe ◽  
Yen Adams Sokama-Neuyam

AbstractNon-thermal plasma (NTP) is a promising technology for the improvement of indoor air quality (IAQ) by removing volatile organic compounds (VOCs) through advanced oxidation process (AOP). In this paper, authors developed a laboratory scale dielectric barrier discharge (DBD) reactor which generates atmospheric NTP to study the removal of low-concentration formaldehyde (HCHO), a typical indoor air VOC in the built environment associated with cancer and leukemia, under different processing conditions. Strong ionization NTP was generated between the DBD electrodes by a pulse power zero-voltage switching flyback transformer (ZVS-FBT), which caused ionization of air molecules leading to active species formation to convert HCHO into carbon dioxide (CO2) and water vapor (H2O). The impact of key electrical and physical processing parameters i.e. discharge power (P), initial concentration (Cin), flow rate (F), and relative humidity (RH) which affect the formaldehyde removal efficiency (ɳ) were studied to determine optimum conditions. Results show that, the correlation coefficient (R2) of removal efficiency dependence on the processing parameters follow the order R2 (F) = 0.99 > R2 (RH) = 0.96, > R2 (Cin) = 0.94 > R2 (P) = 0.93. The removal efficiency reached 99% under the optimum conditions of P = 0.6 W, Cin = 0.1 ppm, F = 0.2 m3/h, and RH = 65% with no secondary pollution. The study provided a theoretical and experimental basis for the application of DBD plasma for air purification in the built environment.


Sign in / Sign up

Export Citation Format

Share Document