scholarly journals Archie's law – a reappraisal

Solid Earth ◽  
2016 ◽  
Vol 7 (4) ◽  
pp. 1157-1169 ◽  
Author(s):  
Paul W. J. Glover

Abstract. When scientists apply Archie's first law they often include an extra parameter a, which was introduced about 10 years after the equation's first publication by Winsauer et al. (1952), and which is sometimes called the “tortuosity” or “lithology” parameter. This parameter is not, however, theoretically justified. Paradoxically, the Winsauer et al. (1952) form of Archie's law often performs better than the original, more theoretically correct version. The difference in the cementation exponent calculated from these two forms of Archie's law is important, and can lead to a misestimation of reserves by at least 20 % for typical reservoir parameter values. We have examined the apparent paradox, and conclude that while the theoretical form of the law is correct, the data that we have been analysing with Archie's law have been in error. There are at least three types of systematic error that are present in most measurements: (i) a porosity error, (ii) a pore fluid salinity error, and (iii) a temperature error. Each of these systematic errors is sufficient to ensure that a non-unity value of the parameter a is required in order to fit the electrical data well. Fortunately, the inclusion of this parameter in the fit has compensated for the presence of the systematic errors in the electrical and porosity data, leading to a value of cementation exponent that is correct. The exceptions are those cementation exponents that have been calculated for individual core plugs. We make a number of recommendations for reducing the systematic errors that contribute to the problem and suggest that the value of the parameter a may now be used as an indication of data quality.

2016 ◽  
Author(s):  
Paul W. J. Glover

Abstract. When scientists apply Archie's first law they often include an extra parameter a, which was introduced about 10 years after the equation's first publication by Winsauer et al., and which is sometimes called the "tortuosity" or "lithology" parameter. This parameter is not, however, theoretically justified. Paradoxically, the Winsauer et al. form of Archie's law often performs better than the original, more theoretically correct version. The difference in the cementation exponent calculated from these two forms of Archie's law is important, and can lead to a mis-estimation of reserves by at least 20 % for typical reservoir parameter values. We have examined the apparent paradox, and conclude that while the theoretical form of the law is correct, the data that we have been analysing with Archie's law has been in error. There are at least three types of systematic error that are present in most measurements; (i) a porosity error, (ii) a pore fluid salinity error, and (iii) a temperature error. Each of these systematic errors is sufficient to ensure that a non-unity value of the parameter a is required in order to fit the electrical data well. Fortunately, the inclusion of this parameter in the fit has compensated for the presence of the systematic errors in the electrical and porosity data, leading to a value of cementation exponent that is correct. The exceptions are those cementation exponents that have been calculated for individual core plugs. We make a number of recommendations for reducing the systematic errors that contribute to the problem and suggest that the value of the parameter a may now be used as an indication of data quality.


2021 ◽  
Author(s):  
Alexis An Yee Low ◽  
William John Telesfor Hopper ◽  
Ilinca Angelescu ◽  
Liam Mason ◽  
Geert-Jan Will ◽  
...  

A major challenge in understanding the neurobiological basis of psychiatric disorders is to rigorously quantify subjective metrics that lie at the core of mental illness, such as low self-esteem. Self-esteem can be conceptualized as a ‘gauge of social approval’ that increases in response to approval and decreases in response to disapproval. Computational modelling approaches have shown that learning signals that represent the difference between received and expected social approval drive changes in self-esteem. However, it is unclear whether self-esteem based on social approval should be understood as a value updated through associative learning, or as a belief about the self, updated by new evidence depending on how strongly it is held. Our results show that belief-based models explain self-esteem dynamics in response to social evaluation better than associative learning models. Importantly, our findings suggest that in the short term, self-esteem signals the direction and rate of change of one’s beliefs about approval within a group, rather than one’s social position.


Author(s):  
John P. Langmore ◽  
Brian D. Athey

Although electron diffraction indicates better than 0.3nm preservation of biological structure in vitreous ice, the imaging of molecules in ice is limited by low contrast. Thus, low-dose images of frozen-hydrated molecules have significantly more noise than images of air-dried or negatively-stained molecules. We have addressed the question of the origins of this loss of contrast. One unavoidable effect is the reduction in scattering contrast between a molecule and the background. In effect, the difference in scattering power between a molecule and its background is 2-5 times less in a layer of ice than in vacuum or negative stain. A second, previously unrecognized, effect is the large, incoherent background of inelastic scattering from the ice. This background reduces both scattering and phase contrast by an additional factor of about 3, as shown in this paper. We have used energy filtration on the Zeiss EM902 in order to eliminate this second effect, and also increase scattering contrast in bright-field and dark-field.


2018 ◽  
Vol 2 (5) ◽  
pp. 744
Author(s):  
Zainur Zainur

This research was motivated by the low learning outcomes of grade IX SMP Muhammadiyah Padang LuasKecamatan Tambang Kabupaten Kampar. This study aims to improve learning outcomes in mathematicslearning through STAD type cooperative learning with the RME approach in class IX SMP MuhammadiyahPadang Luas Kecamatan Tambang Kabupaten Kampar. The subjects of this study were all classes IX in SMPMuhammadiyah Padang Luas Kecamatan Tambang Kabupaten Kampar totaling 26 people. The form ofresearch is classroom action research. This research instrument consists of performance instruments and datacollection instruments in the form of teacher activity observation sheets and activities. The results of the studystated that there were significant differences between students' mathematics learning outcomes before applyingthe STAD type cooperative learning model with the RME approach with after applying the STAD typecooperative learning model with the RME approach. The difference shows student learning outcomes after theaction is better than before the action with completeness reaching 80.77% or 21 completed. Based on the resultsof the study and discussion it can be concluded that the application of STAD type learning model with RealisticMathematic Education (RME) approach can improve the learning outcomes of grade IX students of SMPMuhammadiyah Padang Luas Kecamatan Tambang Kabupaten Kampar on statistical material.


2020 ◽  
Vol 14 (2) ◽  
pp. 229-233
Author(s):  
Yongbin Zhang

Background:: The challenges to nanoporous filtration membranes are small fluxes and low membrane mechanical strengths. Objective:: To introduce newly invented nanoporous filtration membranes with complex pores, improved fluxes and mechanical strengths as registered in patents. Methods:: The analytical results are presented for the addressed membranes. Results:: The geometrical parameter values of the addressed membranes can be optimized for the highest fluxes. Conclusion:: The overall performances of nanoporous filtration membranes with complex cylindrical or/and conical pores can be significantly better than that of the conventional nanoporous filtration membranes with single cylindrical or conical pores.


2021 ◽  
Vol 13 (12) ◽  
pp. 6914
Author(s):  
Frikkie Alberts Maré ◽  
Henry Jordaan

The high water intake and wastewater discharge of slaughterhouses have been a concern for many years. One neglected factor in previous research is allocating the water footprint (WF) to beef production’s different products and by-products. The objective of this article was to estimate the WF of different cattle breeds at a slaughterhouse and cutting plant and allocate it according to the different cuts (products) and by-products of beef based on the value fraction of each. The results indicated a negative relationship between the carcass weight and the processing WF when the different breeds were compared. Regarding a specific cut of beef, a kilogram of rib eye from the heaviest breed had a processing WF of 614.57 L/kg, compared to the 919.91 L/kg for the rib eye of the lightest breed. A comparison of the different cuts indicated that high-value cuts had higher WFs than low-value cuts. The difference between a kilogram of rib eye and flank was 426.26 L/kg for the heaviest breed and 637.86 L/kg for the lightest breed. An option to reduce the processing WF of beef is to lessen the WF by slaughtering heavier animals. This will require no extra investment from the slaughterhouse. At the same time, the returns should increase as the average production inputs per kilogram of output (carcass) should reduce, as the slaughterhouse will process more kilograms.


2020 ◽  
Vol 30 (Supplement_5) ◽  
Author(s):  
R Bosco ◽  
S Gambelli ◽  
V Urbano ◽  
G Cevenini ◽  
G Messina

Abstract Background Sanitizing the operating theatres (OT) is important to minimize risk of post-operative infections. Disinfection procedures between one operation and another is less aggressive than final cleaning procedures, at the end of the day. Aim was assessing the difference of contamination: i) between different levels of disinfection; ii) before and after the use of a UVC Device (UVC-D). Methods Between December 2019/February 2020 a cross sectional study was conducted in OT in a real clinical context. 94 Petri dishes (PD) were used in 3 OT. Three different sanitation levels (SL1-3) were compared pre- and post-use of UVC-D: i) No cleaning after surgery (SL1); ii) after in-between cleaning (SL2); iii) after terminal cleaning (SL3). UVC-D was employed for 6 minutes, 3 minutes per bed side. PD were incubated at 36 °C and colony forming unit (CFU) counted at 48h. Descriptive statistic, Wilcoxon and Mann-Whitney tests were performed to assess the contamination levels in total, pre/post use of UVC-D, and between different sanitation levels, respectively. Results In total we had a mean of 3.39 CFU/PD (C.I. 2.05 - 4.74) and a median of 1 CFU/PD (Min. 0 - Max. 39), after UVC-D use we had a mean of 2.20 CFU/PD (C.I. 0.69 - 5.09) and a median of 0 CFU/PD (Min. 0 - Max. 133). The UVC-D led to a significant reduction of CFU (p < 0.001). Without UVC-D we had a significant CFU drop (p < 0.05) between SL1 and SL3. Using UVC-D, we observed significant reductions of contamination (p < 0.05) between SL3 and SL1. Comparing SL1 (median 0) post UVC-D use vs SL2 pre UVC-D use (median 0.5), and SL2 post UVC-D use (median 0) vs SL3 pre UVC-D use (median 1) we had a significant reduction of contamination (p < 0.05). Conclusions UVC-D improved environmental contamination in any of the three sanitation levels. Furthermore, the use of UVC-D alone was better than in-between and terminal cleaning. Although these encouraging results, the cleaning procedures executed by dedicated staff has to be considered. Key messages UVC are efficient to decrease contamination in operating theatres regardless of sanitation levels. The additional use of UVC technology to standard cleaning procedures significantly improves sanitation levels.


1998 ◽  
Vol 11 (1) ◽  
pp. 551-551
Author(s):  
N. Zacharias ◽  
M.I. Zacharias ◽  
C. de Vegt ◽  
C.A. Murray

The Second Cape Photographic Catalog (CPC2) contains 276,131 stars covering the entire Southern Hemisphere in a 4-fold overlap pattern. Its mean epoch is 1968, which makes it a key catalog for proper motions. A new reduction of the 5687 plates using on average 40 Hipparcos stars per plate has resulted in a vastly improved catalog with a positional accuracy of about 40 mas (median value) per coordinate, which comes very close to the measuring precision. In particular, for the first time systematic errors depending on magnitude and color can be solved unambiguously and have been removed from the catalog. In combination with the Tycho Catalogue (mean epoch 1991.25) and the upcoming U.S. Naval Observatory CCD Astrograph Catalog (UCAC) project proper motions better than 2 mas/yr can be obtained. This will lead to a vastly improved reference star catalog in the Southern Hemisphere for the final Astrographic Catalogue (AC) reductions, which will then provide propermotions for millions of stars when combined with new epoch data. These data then will allow an uncompromised reduction of the southern Schmidt surveys on the International Celestial Reference System (ICRS).


2007 ◽  
Vol 330-332 ◽  
pp. 495-498
Author(s):  
Chao Zou ◽  
Wen Jian Weng ◽  
Xu Liang Deng ◽  
Kui Cheng ◽  
Pi Yi Du ◽  
...  

Two starting collagens, sponge and floc collagen, were used to prepare collagen/tricalcium phosphate (TCP) composites. The resulting composites were porous and had 200μm pore size. However, there was a difference in the microstructure of the pore walls for the composites derived from the two collagens, the pore walls in sponge collagen/TCP composite were still porous and had 200 nm micropores size, TCP particles were trapped in collagen matrices. While floc collagen/TCP composite had smooth and dense walls in which TCP particles were embedded. The difference could be attributed to the starting collagen with different status. Sponge collagen has a soft structure, which easily becomes disassembled fibrils during alkali treatment, the disassembled fibrils are integrated again to form a dense morphology for pore walls after freeze-drying. While floc collagen has already a low disassembly degree, the alkali treatment could not be able to separate the fibrils, this remains as micropores in pore walls after freeze-drying. Both porous composites are significant in bone tissue engineering or regeneration. MTT test results showed the two composites had good cytocompatibility, and sponge collagen/TCP composite was somewhat better than floc collagen/TCP composite, which could result from that micropores derived roughness in pore walls of sponge collagen/TCP composite is suitable for cell growth.


1988 ◽  
Vol 55 (4) ◽  
pp. 579-583 ◽  
Author(s):  
Lucas Dominguez ◽  
José Francisco Fernández ◽  
Victor Briones ◽  
José Luis Blanco ◽  
Guillermo Suárez

SummaryDifferent selective agar media were compared for the recovery and isolation of five species ofListeriafrom raw milk and cheese. The selective media examined were Beerens medium, MacBride medium and that described by Dominguezet al.(1984) with 6 mg/1 acriflavine, listeria selective agar medium (LSAM), and LSAM with 12 mg/1 acriflavine (LSAM × 2A); a non-selective yeast glucose Lemco agar was included for comparison. When the difference between listeria and the natural microflora of raw milk and cheese was 102cfu/ml, listeria could be isolated by direct plating on all media tested. When it was lower than 103–104cfu/ml, listeria were isolated by direct plating only on LSAM and LSAM × 2A. When the difference was greater than 104cfu/ml, a previous enrichment was necessary to isolate them. LSAM and LSAM × 2A media performed better than the other media tested for isolating listeria by direct plating and improved their isolation from dairy products. This superior performance was evaluated by the ability of these media to support colony formation of different species ofListeriatested, the easy recognition of these colonies from those formed by other microorganisms and by their capacity to inhibit the natural microflora of these foods.


Sign in / Sign up

Export Citation Format

Share Document