scholarly journals Influence of Solar Energy on the Physicochemical Parameters of Effluent Sludge and the Receiving Stream of an Oxidation Pond

Author(s):  
F. O. Omoya ◽  
A. O. Olalemi

Aim: This study was aimed at determining the physicochemical characteristics (such as pH, dissolved oxygen, biological oxygen demand, nitrogen, phosphorus, chloride, iron, lead, magnesium etc.) of the effluent sludge from a sewage oxidation pond and the receiving stream before and after exposure to solar energy. This is to gain a better understanding on how ultraviolet radiations from sunlight alters the physicochemical parameters inherent in the sludge and the stream. Methods and Results: Effluent sludge samples and water samples from the receiving stream were collected and exposed to solar energy over a twenty-day period. Physicochemical parameters were measured using standard methods. Results revealed that mean values of dissolved oxygen and pH increased whereas those of biological oxygen demand, ammonia nitrogen, chloride, phosphorus, iron, lead zinc and magnesium reduced over the period study. Conclusion: The findings from this study suggest that the addition of solar energy to the chains of processes in sewage treatment will produce effluents with minimal content of nutrients from organic matter and heavy metals and these will ultimately protect the receiving stream from contamination, thus contributing to human health protection.

1970 ◽  
Vol 23 (10) ◽  
pp. 1835-1839
Author(s):  
Y. Abdullahi ◽  
P. Moses ◽  
V.B. Kwaya

Studies were conducted on the diversity, distribution and physicochemical characteristics of phytoplanktons of Pindiga Pond. Water and phytoplankton samples were collected for three months at ten (10) days interval. The objective of the present research is to determine the phytoplanktons distribution and physicochemical characteristics of the Pond. Standard procedures were adopted for determination of physicochemical parameters viz; Temperature, pH, Transparency, Conductivity, Nitrate, Phosphate, Dissolved oxygen (DO), Biological Oxygen Demand (BOD).These physicochemical characteristics were observed to have varied within the period of the study. Seventeen (17) genus, Thirteen (13) orders, four (4) classes, and four (4) division of phytoplankton were identified, and the class Bacillariophyceae (46 %) was the highest percentage recorded during the study, Chlorophyceae (32 %), Euglenophyceae (19 %) and Cyanophyceae (3%) the least in occurrence and distribution. The study also revealed that pindiga pond had luxuriant phytoplanktons flora, diverse and seasonal with fluctuating pattern of physicochemical characteristics recorded. The physicochemical characteristics were also within productive limit in Pindiga pond.Key words: Phytoplanktons, Diversity, Distribution, Pond


2014 ◽  
Vol 26 (4) ◽  
pp. 367-380 ◽  
Author(s):  
Beatriz Concepción Tracanna ◽  
Silvia Nelly Martínez De Marco ◽  
María de los Ángeles Taboada ◽  
Virginia Mirande ◽  
María de Lourdes Gultemirian ◽  
...  

AIM: The Escaba dam is located in the south of the Tucumán province, Argentina, at 650 m above sea level. It has an extension of 541 ha. and a depth of 65 m and its tributaries are the Chavarría, Las Moras, El Chorro and Singuil rivers. The climate is mild with dry winters and rainy summers. The objective of this study was to characterize physicochemical parameters in the limnetic zone of the dam and the mouths of the tributaries to determine the water quality. METHODS: Seasonal sampling was carried out between August 2010 and May 2012. Temperature, transparency, pH and electrical conductivity were field measured, whereas dissolved oxygen, biochemical oxygen demand (BOD5), major ion constituents and nitrogen and phosphate compounds were analyzed at the laboratory. RESULTS: The water was classified as sodium-calcium-bicarbonate with neutral to alkaline pH, and thermal stratification during spring and summer. The water assayed was well oxygenated except for the bottom of the limnetic zone during the summer months. Lowest transparency was measured in the El Chorro River in November 2011 (0.12 m) and highest degree of transparency in the Singuil River during the winter of 2010 (4.1 m). The waters assayed showed weak mineralization with conductivities between 83 and 218 µS.cm-1. Maximum BOD5 value (183 mg.L-1) was measured in the Singuil River in spring 2010. Highest values for the different nitrogen compounds were as follows: 7 mg NO3-.L-1 at the bottom of the limnetic zone in August 2010, 0.07 mg NO2-.L-1 in the Las Moras River in May 2011 and 1.8 mg NH4+.L-1 in the Chavarría River in March 2011. During the summer of 2012 orthophosphate reached a value of 0.22 mg.L-1 at the bottom of the limnetic zone. The TN/TP ratio revealed that phosphate was generally the limiting factor and rarely nitrogen. CONCLUSIONS: Considering the TN, TP and transparency parameters the ecosystem was classified as hypertrophic. PCA allowed a seasonal differentiation of the sites, and components 1 and 2 classified the samples according to nutrient gradient, dissolved oxygen, BOD5 and temperature.


Author(s):  
Vasudha Lingampally ◽  
V.R. Solanki ◽  
D. L. Anuradha ◽  
Sabita Raja

In the present study an attempt has been made to evaluate water quality and related density of Cladocerans for a period of one year, October 2015 to September 2016. Water quality parameters such as temperature, PH, total dissolved solids, dissolved oxygen, biological oxygen demand, total alkalinity, total hardness, chlorides, phosphates, and nitrates are presented here to relate with the abundance of Cladocerans. The Cladoceran abundance reflects the eutrophic nature of the Chakki talab.


Jurnal Ecolab ◽  
2021 ◽  
Vol 15 (2) ◽  
pp. 101-109
Author(s):  
Dewi Ratnaningsih ◽  
◽  
Retno Puji Lestari ◽  
Ernawita Nazir

Kualitas air di suatu wilayah yang merupakan salah satu indikator lingkungan dapat dievaluasi menggunakan parameter fisika, kimia, dan biologi. Indeks Kualitas Air Indonesia (IKA-INA) dapat digunakan untuk menilai kondisi kualitas air secara menyeluruh pada lokasi dan waktu tertentu. IKA-INA dihitung dengan menggunakan sepuluh (10) parameter yaitu pH, Total Dissolved Solid (TDS), Total Suspended Solid (TSS), Dissolved Oxygen (DO), Biological Oxygen Demand (BOD), Chemical Oxygen Demand (COD), NO3, NH3, Total Phosphate (TP) dan fecal coliform. IKA-INA tersebut merupakan indeks kualitas air yang dapat memberikan informasi secara sederhana. Dalam pemanfaatannya, tidak semua data parameter dalam IKA-INA tersebut dapat terpenuhi karena adanya data tidak valid atau data yang hilang. Kajian ini bertujuan untuk memberi alternatif rumusan IKA-INA dengan parameter yang tidak lengkap atau jika tidak semua data dalam parameters tersebut tersedia. Metode yang digunakan dalam menyusun rumusan adalah dengan melakukan koreksi faktor bobot parameter IKA-INA terhadap parameter yang hilang dan nilai Q (nilai sub-indeks). Setelah itu dilakukan uji coba pada nilai baku mutu air dalam Peraturan Pemerintah No. 22/2021 Lampiran VI serta pada data kualitas air sungai yang mewakili kualitas baik dan buruk. Hasil uji coba menunjukkan bahwa bobot parameter terkoreksi dapat digunakan untuk penanganan parameter yang hilang dalam penilaian kualitas air dengan metode IKA-INA. Hasil IKA-INA dengan parameter hilang yang menggunakan bobot terkoreksi dan hasil IKA-INA dengan parameter lengkap mayoritas memberikan status IKA yang tidak berbeda, kecuali untuk parameter fecal coli dan parameter yang mempunyai kadar jauh berbeda terhadap kondisi air secara keseluruhan.


2015 ◽  
Vol 16 (SE) ◽  
pp. 395-403
Author(s):  
Abbas Ghaffari Habib ◽  
Seyed Hadi Khatami

In Bahar County (Iran), rivers are among the important sources of water for the agricultural sector. Therefore, this research evaluated the parameters of temperature, pH, Total Dissolved Solids (TDS), turbidity, nitrate, total phosphate, dissolved oxygen (DO), Biological Oxygen Demand (BOD5), and fecal coliform at five stations for five months (from February 2015 to June 2015) to determine water quality in the rivers. Based on this evaluation, the NSFWQI index was calculated and, finally, the routes of the rivers were zoned. The best water quality was recorded at Station Number 3 with the NSFWQI Value of 80 in January, and the worst at Station Number 5 (latgah) with the NSFWQI Value of 37 in June. Based on the mean NSFWQI indices, water quality was Medium at Stations Number 1, 2, and 4, good at Station Number 3, and bad at Station number 5.


Our Nature ◽  
1970 ◽  
Vol 9 (1) ◽  
pp. 156-167 ◽  
Author(s):  
D. Thapa Chhetry ◽  
J. Pal

The Koshi river is the major tributaries of the Ganges which originates from the snowy peaks of Tibetan plateau in the central Himalayas. Its total catchment area is 60,400 km2, of which 28,140 km2 lies in Nepal, while the remainder is situated in Tibet. It passes from Nepal to India via the Koshi Tappu Wildlife Reserve area of Nepal. It destroys large area through floods, especially in India. This paper deals with the air temperature and phyco-chemical parameters like temperature, transparency, pH, oxygen, carbondioxide, alkalinity, hardness, chloride and biological oxygen demand of water of Koshi river at Kushaha area of Koshi Tappu Wildlife Reserve. The water temperature was recorded maximum in summer season but the transparency, pH, dissolved oxygen, total alkalinity and total hardness were recorded maximum in winter season. Similarly, free carbondioxide was maximum in rainy season and chloride and biological oxygen demand were recorded maximum in summer season. The air temperature and water temperature had positive and significant correlation with free carbondioxide and biological oxygen demand. Dissolved oxygen had positive and significant correlation with pH, total alkalinity and total hardness. Similarly, total alkalinity had positive and significant correlation with transparency, total hardness, chloride etc.DOI: http://dx.doi.org/10.3126/on.v9i1.5746


2019 ◽  
Vol 10 (2) ◽  
pp. 17
Author(s):  
Okezie Onyemaechi ◽  
Nwachukwu Ejikeme

Water samples from twenty water sources (fifteen boreholes and five streams) in Uzuakoli, Nigeria were collected for the period of 6 months covering the dry and rainy seasons to assess the level of contamination. The Microbiological characteristics including heterotrophic counts, coliform counts and physicochemical parameters includes pH, turbidity, dissolved oxygen, calcium, potassium, nitrate, magnesium and phosphate were evaluated using standard methods. The total Heterotrophic counts for the borehole during the dry and rainy season were 8.3 x 103 cfu/ ml and 10.8 x 104 cfu/ ml. The Heterotrophic counts for the stream were 12.7 x 104 cfu/ ml and 17.8x 106 cfu/ ml. The frequency of occurrence of the isolates are Staphylococcus aureus 63% in borehole and 85% in streams, Pseudomonas aeruginosa 49% in boreholes and 95% in streams, Proteus sp 52% in boreholes and 97% in streams, Streptococcus sp 46% in boreholes and 53% in streams, Enterobacter aerogenes 33% in boreholes and 63% in streams, Escherichia coli 16% in boreholes and 53% in streams and Salmonella sp no percentage in boreholes and 40% in streams. The result shows a significant difference at (P≤0.05) for the bacterial isolates. The physicochemical parameters of the borehole and stream water samples during the dry and rainy seasons were determined. The temperature ranged from 25oC 32oC; pH ranged from 5.3 8.1; turbidity ranged 0.03 3.23; dissolved oxygen ranged from 3.45–7.40mg/l; biochemical oxygen demand ranged from 1.20–4.32mg/l; chemical oxygen demand ranged from 2.50–5.21mg/l; Calcium ranged from 0.81–5.64mg/l; potassium ranged from 1.01–4.22mg/l; Nitrate ranged from 1.49–4.02mg/l; magnesium ranged from 0.13–2.20mg/l; phosphate ranged from 0.51–2.01mg/l. The water samples were all within the WHO limits apart from sample from Iyi Agbozu that had temperature of 32oC.


2019 ◽  
Vol 11 (8) ◽  
pp. 2284 ◽  
Author(s):  
Jin Xu ◽  
Peifang Wang ◽  
Yi Li ◽  
Lihua Niu ◽  
Zhen Xing

In this study, we examined the influence of the organic carbon-to-nitrogen ratio (chemical oxygen demand (COD/N)) and dissolved oxygen (DO) levels on the removal efficiency of pollutants and on the change in total microflora in the cyclic activated sludge system (CASS) in the Nyingchi prefecture in Tibet. The results demonstrated that the treatment performance was the best when the COD/N ratio was 7:1 or the DO levels were 2–2.5 mg/L in comparison with four different tested COD/N ratios (4:1, 5:1, 7:1, and 10:1) and DO concentrations (0.5–1, 1–2, 2–2.5, and 2.5–3.5 mg/L). The treatment performance can be explained by the relative operational taxonomic unit richness and evenness of the microbial communities in activated sludge. Evident microbial variance was observed, especially different COD/N ratios and DO concentrations, which were conducive to the disposal of urban sewage in plateaus. The results help to understand sewage treatment under different COD/N ratios or DO concentrations on plateaus. This work provides practical guidance for the operation of any wastewater treatment plant on a plateau.


2012 ◽  
Vol 263-266 ◽  
pp. 510-515
Author(s):  
Li Mei Dong ◽  
Ying Chang Zhou ◽  
Ze Chi Han ◽  
Fei Wang ◽  
Yong Qing Wang ◽  
...  

The device is composed of solar battery, power automatic switching, high pressure booster inverter, dielectric-barrier discharge type ozonizer, air compressor and microporous aerator components, whicn is powered by the double power suppl y modes including the solar battery and the city electricity. In the conditions of insufficient illumination or rainy weather, power can switch to the city electricity automatically. The article introduces the composition and working principle of solar ozonizer. The experiment is respectively done in the sample of the second phase of water from BaoDingYingdingzhuang sewage plant, the urban river water and the dyeing effluent with 1500 ml.The power of the solar energy ozonizer is 18W and ozone production is 25 mg/min. The experiment results show that the removal rate of Fecal coliform, Chroma and Chemical Oxygen Demand (COD) are obviously improved. Especially, the removal effect of Fecal coliform and Chroma is very significant. The experiment indicates that the content of NH3-N has increased with the growth of ozone contact time.


Author(s):  
EUKENE OPORTO BENSIG ◽  
MARY JOYCE L. FLORES ◽  
FLEURDELIZ F. MAGLANGIT

The use of surface waters such as rivers for domestic, agricultural andindustrial purposes have made them vulnerable to pollution leading to impairedwater quality. The water quality of Lahug River in Cebu City was evaluated usingcoliforms as indicators, in relation with physicochemical parameters such as biological oxygen demand (BOD), conductivity, dissolved oxygen (DO), nitrate,pH, phosphate, salinity, temperature, total dissolved solids (TDS) and totalsuspended solids (TSS). Sampling was done once a month from November 2011to April 2012 in three stations covering the upstream, midstream and downstream.The multiple tube fermentation technique was used for the analysis of coliforms.The level of these indicator bacteria increased from the upstream towards thelower reaches of the river especially in the months of February to April; however,the difference in values across time was not significant. This implies that therewas a continuous fecal pollution in the river. There were no statistically significantcorrelations between FCs and TCs with the physicochemical parameters. Anegative relationship was observed among FCs and TCs with pH, TSS, DOand nitrate (p>0.05). These results suggest the presence of sewage and organicpollutants in the river.Keywords: Aquatic Ecology, water quality, coliform, physicochemical parameters,experimental design, Philippines


Sign in / Sign up

Export Citation Format

Share Document