capillary flow
Recently Published Documents


TOTAL DOCUMENTS

1152
(FIVE YEARS 175)

H-INDEX

56
(FIVE YEARS 7)

2022 ◽  
Author(s):  
Sangwook Bae ◽  
Daewon Lee ◽  
Hunjong Na ◽  
Jiseong Jang ◽  
Sunghoon Kwon

Barcoded planar microparticles have many qualities suitable for developing cost-efficient multiplexed immunoassays. But at the translational research level, there are a number of technical aspects yet remain to be addressed which includes robustness and efficiency of the assay readout process. Assay readout process involves automated barcode identification and signal intensity values from each planar microparticle. For this, each microparticle has to be correctly aligned for correct barcode readout while being, ideally, compactly assembled for maximum microparticle imaging efficiency. To simultaneously achieve such alignment and assembly of microparticles but in a straightforward manner, we designed a microfluidic microparticle assembling chip that only requires a single pipetting step. Our design utilizes capillary flow based guided particle assembly, which allows maximum microparticle-based immunoassay readout efficiency. With the aid of image processing algorithms, we obtained good multiplex immunoassay readout accuracy similar to conventional imaging platforms. Our approach is applicable to both soft elastomer materials (e.g. PDMS) and rigid materials (e.g. polystyrene), the latter of which is frequently used for injection molding based mass production. We anticipate our device could help developing facile and user-friendly platform technologies based on barcoded planar microparticles.


Nano Energy ◽  
2022 ◽  
pp. 106917
Author(s):  
Beibei Shao ◽  
Yanfei Wu ◽  
Zheheng Song ◽  
Haiwei Yang ◽  
Xin Chen ◽  
...  

Author(s):  
Stefan Höving ◽  
Jens Bobers ◽  
Norbert Kockmann

Abstract Limited applicability and scarce availability of analytical equipment for micro- and millifluidic applications, which are of high interest in research and development, complicate process development, control, and monitoring. The low-cost sensor presented in this work is a modular, fast, non-invasive, multi-purpose, and easy to apply solution for detecting phase changes and concentrations of optically absorbing substances in single and multi-phase capillary flow. It aims at generating deeper insight into existing processes in fields of (bio-)chemical and reaction engineering. The scope of this work includes the application of the sensor to residence time measurements in a heat exchanger, a tubular reactor for concentration measurements, a tubular crystallizer for suspension detection, and a pipetting robot for flow automation purposes. In all presented applications either the level of automation has been increased or more information on the investigated system has been gained. Further applications are explained to be realized in the near future. Article highlights • An affordable multipurpose sensor for phase differentiation, concentration measurements, and process automation has been developed and characterized • The sensor is easily modified and can be applied to various tubular reaction/process units for analytical and automation purposes • Simple integration into existing process control systems is possible Graphical abstract


Author(s):  
Xuewei Zhang ◽  
Sylvie Lorente

Abstract Capillary flows are an attractive feature for passive water harvesting as they require no external driving force to pull the fluid out within the capillary network. Here we analyze the architecture of capillary flow networks in steady state, and the impact of the network morphology on the maximum mass flow rate that can be extracted for a fixed network volume and fixed network footprint. We develop a search algorithm to test the possible location of all the junction and bifurcation nodes and the changes in diameter ratios with the objective of obtaining the maximum mass flow rate from the network. We define the Capillary Strength CS as a local indicator to determine the geometrical parameters of each conduct that allow to sustain the overall mass flow rate. It is shown that the diameter ratio of connected tubes for maximum mass flow rate depends on the distance from the network outlet, and therefore does not follow the Hess-Murray’s law. The superiority of dendritic architectures in the roots and canopy branches of the capillary trees is demonstrated.


2021 ◽  
Author(s):  
Mohamed Yafia ◽  
Oriol Ymbern ◽  
Ayokunle Olanrewaju ◽  
Azim Parandakh ◽  
Ahmad Sohrabi Kashani ◽  
...  

Chain reactions are characterized by initiation, propagation and termination, are stochastic at microscopic scales and underlie vital chemical (e.g. combustion engines), nuclear and biotechnological (e.g. polymerase chain reaction) applications.1-5 At macroscopic scales, chain reactions are deterministic and limited to applications for entertainment and art such as falling domino and Rube Goldberg machines. Appositely, the microfluidic lab-on-a-chips (also called a micro total analysis system),6,7 was envisioned as an integrated chip, akin to microelectronic integrated circuits, yet in practice remain dependent on cumbersome peripherals, connections, and a computer for automation.8-11 Capillary microfluidics integrate energy supply and flow control onto a single chip by using capillary phenomena, but programmability remains rudimentary with at most a handful (eight) operations possible.12-19 Here we introduce the microfluidic chain reaction (MCR) as the conditional, structurally programmed propagation of capillary flow events. Monolithic chips integrating a MCR are 3D printed, and powered by the free-energy of a paper pump, autonomously execute liquid handling algorithms step-by-step. With MCR, we automated (i) the sequential release of 300 aliquots across chained, interconnected chips, (ii) a protocol for SARS-CoV-2 antibodies detection in saliva, and (iii) a thrombin generation assay by continuous subsampling and analysis of coagulation-activated plasma with parallel operations including timers, iterative cycles of synchronous flow and stop-flow operations. MCRs are untethered from and unencumbered by peripherals, encode programs structurally in situ, and can form frugal, versatile, bona fide lab-on-a-chip with wide-ranging applications in liquid handling and point-of-care diagnostics.


2021 ◽  
Vol 12 (1) ◽  
Author(s):  
Emil G. P. Stender ◽  
Soumik Ray ◽  
Rasmus K. Norrild ◽  
Jacob Aunstrup Larsen ◽  
Daniel Petersen ◽  
...  

AbstractLiquid-liquid phase separation or LLPS of proteins is a field of mounting importance and the value of quantitative kinetic and thermodynamic characterization of LLPS is increasingly recognized. We present a method, Capflex, which allows rapid and accurate quantification of key parameters for LLPS: Dilute phase concentration, relative droplet size distributions, and the kinetics of droplet formation and maturation into amyloid fibrils. The binding affinity between the polypeptide undergoing LLPS and LLPS-modulating compounds can also be determined. We apply Capflex to characterize the LLPS of Human DEAD-box helicase-4 and the coacervate system ssDNA/RP3. Furthermore, we study LLPS and the aberrant liquid-to-solid phase transition of α-synuclein. We quantitatively measure the decrease in dilute phase concentration as the LLPS of α-synuclein is followed by the formation of Thioflavin-T positive amyloid aggregates. The high information content, throughput and the versatility of Capflex makes it a valuable tool for characterizing biomolecular LLPS.


2021 ◽  
Vol 2129 (1) ◽  
pp. 012058
Author(s):  
Uda Hashim ◽  
Tijjani Adam ◽  
Nuri A.KH. Ehfaed ◽  
M N Afnan Uda ◽  
M N A Uda

Abstract The paper present design and fabrication of capillary driven muilti channels microfluidic. AutoCAD assisted layout design was conducted and fabricated based on cold photolithography process with precise geometry for capillary flow. The design was bonded with glass to test the flow and bonding integrity. The device was tested for flow and it was found the uniform capillary flow was established with strong bonding energy.


2021 ◽  
Vol 7 (1) ◽  
Author(s):  
Panayiotis Kolliopoulos ◽  
Satish Kumar

AbstractCapillary flow is the spontaneous wicking of liquids in narrow spaces without the assistance of external forces. Examples of capillary flow can be found in numerous applications ranging from controlling and transporting fuel in spacecrafts to printed electronics manufacturing. Open rectangular microchannels often appear in these applications, with the lack of a top resulting in a complex free-surface morphology and evaporation. Here, we present a brief overview of this topic and discuss some recent advances.


Sign in / Sign up

Export Citation Format

Share Document