A Comparison of the Clearance of Urographic Contrast Medium (Sodium Diatrizoate) by Peritoneal and Haemodialysis

1976 ◽  
Vol 50 (1) ◽  
pp. 69-74
Author(s):  
P. Ackrill ◽  
C. S. McIntosh ◽  
C. Nimmon ◽  
L. R. I. Baker ◽  
W. R. Cattell

1. The clearance of isotopically labelled sodium diatrizoate by haemodialysis was measured in vitro, with simulated extracellular fluid, and in vivo in eleven patients, at varying rates of fluid or plasma flow. Clearance was also measured in five patients undergoing peritoneal dialysis. In all instances simultaneous measurements of urea clearance were made and the diatrizoate/urea clearance ratio was calculated. 2. In haemodialysis studies, diatrizoate and urea clearances showed a linear increase with increasing ‘extracellular fluid’ or plasma flow through the dialyser while the diatrizoate/urea clearance ratio fell. 3. The clearance of diatrizoate in vivo was slightly less than clearance in vitro at corresponding flow rates, but the diatrizoate/urea clearance ratio showed no significant difference. 4. Diatrizoate and urea clearances during peritoneal dialysis were very much lower than during haemodialysis but the diatrizoate/urea clearance ratios were within the same range. 5. The rapid removal of diatrizoate in patients with renal failure requires haemodialysis.

1963 ◽  
Vol 205 (3) ◽  
pp. 446-452 ◽  
Author(s):  
Melvin Blecher

In vitro studies of the flux of α-aminoisobutyrate-1-C14 (AIB) between rat thymic lymphocytes and extracellular fluid have revealed that: a) the amino acid enters cells but is not further metabolized; b) at low concentrations, similar to those of amino acids in plasma, the net influx and efflux of AIB exhibit properties of an active process; and c) influx of AIB is inhibited, and efflux stimulated, by deoxycorticosterone (DOC), by metabolic inhibitors, and by other specific steroids. In vivo studies of the distribution of AIB between serum and tissue demonstrated that administration of DOC to adrenalectomized rats inhibited concentration of AIB by thymus, diaphragm, and skeletal muscle, augmented uptake by liver, and increased the serum level of AIB. Prior adrenalectomy of donor rats resulted in no change from normal in the in vitro capacity of thymic lymphocytes to take up AIB. There was no significant difference from normal in the in vivo concentration of AIB by thymus, liver, and skeletal muscle of adrenalectomized rats, although uptake by diaphragm was decreased compared to normal control animals.


1989 ◽  
Vol 9 (3) ◽  
pp. 169-173 ◽  
Author(s):  
Mary Anne Luzar ◽  
Alain Slingeneyer ◽  
Alberto Cantaluppi ◽  
Francesco P. Peluso

Previously published in vitro results, confirmed by clinical studies, indicate that the use of a flush significantly reduces peritonitis in single-use and reusable continuous ambulatory peritoneal dialysis (CAPD) systems. Since reusable systems may use the flush plus inline disinfectant between exchanges, the question remains as to whether or not the flush could be used alone in all disconnect systems. Using an in vitro model, we evaluated the flush in two reusable disconnect systems that use both flush and disinfectant in vivo. In a series of twenty sets per organism per incubation (0 h and 10 h), Y sets were inoculated in the lumen with three pure cultures (103 CFU range). Ability of flush without disinfectant to clear sets of contamination was analyzed by collecting multiple samples at each step of the procedure, enriching with tryptone broth and verifying bacterial growth. When contaminated sets were not incubated, flush efficacy of the systems was consistent with previous data showing 100% removal of Staphylococcus epidermidis, but only partial elimination of Staphylococcus aureus and Pseudomonas aeruginosa. After incubation, simulating reusable systems, the flush was able to eliminate S. epidermidis less than 50% of the time. There was no significant difference in results between the two systems tested. Reusable systems allow more contact time between bacteria and plastic resulting in reduced flush efficacy suggesting that, for safest conditions, they should be used with inline disinfectants.


2017 ◽  
Vol 5 (2) ◽  
pp. 1
Author(s):  
Mulyati Mulyati ◽  
Suryati Suryati ◽  
Irfani Baga

The study aims to isolate, characterize, and examine probiotic bacteria's inhibitory ability against Vibrio harveyi bacteria, both in-vitro and in vivo. Methods used in the study consist of 1) An Isolation of Candidate Probiotic Bacteria, 2) An Antagonistic Test of Candidate Probiotic Bacteria in vitro, 3) An Identification of Bacteria, 4) A Pathogenicity Test of Candidate Probiotic Bacteria, 5) An Antagonistic Test of Candidate Probiotic Bacteria against V. harveyi in vivo. According to the isolation of candidate probiotic bacteria, there are 18 isolated candidate probiotic. After being tested for its inhibitory ability in vitro, there are 8 isolates with zone of inhibition as follows: isolate MM 7 from intestine (22 mm), isolate MM 6 from intestine (12 mm), isolate MM 10 from sea water (10 mm), isolate MM 5 from intestine (9 mm), isolate MM 4 from intestine (8 mm), isolate MM 3 from intestine (7 mm), isolate MM 2.2 from intestine (7 mm), isolate MM 2.1 from intestine (7 mm). Eight genera of the candidate probiotic bacteria is derived from Portunid crab, they are Staphylococcus, Streptococcus, bacillus, vibrio, Alcaligenes, Lactobacillus, micrococcus. Before proceeding the V. harveyi bacterial challenge test in vivo, three potential isolates consisting of MM6, MM7 and MM10 as the probiotic bacteria are pathogenicity-tested against V. harveyi. The survival rate of Portunid crab on pathogenicity test using MM6, MM7 and MM10 generates 91.11-100%, while the control generates 100% survival rate. Variance analysis result through post-hoc Tukey's Honest Significant Difference (HSD) test at 95% confidence interval indicates that isolate MM7 and MM10 are significantly able to increase hatchling Portunid crab's survival rate.


Diagnostics ◽  
2021 ◽  
Vol 11 (1) ◽  
pp. 76
Author(s):  
Anastasia Maslianitsyna ◽  
Petr Ermolinskiy ◽  
Andrei Lugovtsov ◽  
Alexandra Pigurenko ◽  
Maria Sasonko ◽  
...  

Coronary heart disease (CHD) has serious implications for human health and needs to be diagnosed as early as possible. In this article in vivo and in vitro optical methods are used to study blood properties related to the aggregation of red blood cells in patients with CHD and comorbidities such as type 2 diabetes mellitus (T2DM). The results show not only a significant difference of the aggregation in patients compared to healthy people, but also a correspondence between in vivo and in vitro parameters. Red blood cells aggregate in CHD patients faster and more numerously; in particular the aggregation index increases by 20 ± 7%. The presence of T2DM also significantly elevates aggregation in CHD patients. This work demonstrates multimodal diagnostics and monitoring of patients with socially significant pathologies.


Pharmaceutics ◽  
2021 ◽  
Vol 13 (2) ◽  
pp. 216
Author(s):  
Rossana Terracciano ◽  
Aobo Zhang ◽  
E. Brian Butler ◽  
Danilo Demarchi ◽  
Jason H. Hafner ◽  
...  

The heterogeneous distribution of delivery or treatment modalities within the tumor mass is a crucial limiting factor for a vast range of theranostic applications. Understanding the interactions between a nanomaterial and the tumor microenvironment will help to overcome challenges associated with tumor heterogeneity, as well as the clinical translation of nanotheranostic materials. This study aims to evaluate the influence of protein surface adsorption on gold nanoparticle (GNP) biodistribution using high-resolution computed tomography (CT) preclinical imaging in C57BL/6 mice harboring Lewis lung carcinoma (LLC) tumors. LLC provides a valuable model for study due to its highly heterogenous nature, which makes drug delivery to the tumor challenging. By controlling the adsorption of proteins on the GNP surface, we hypothesize that we can influence the intratumoral distribution pattern and particle retention. We performed an in vitro study to evaluate the uptake of GNPs by LLC cells and an in vivo study to assess and quantify the GNP biodistribution by injecting concentrated GNPs citrate-stabilized or passivated with bovine serum albumin (BSA) intratumorally into LLC solid tumors. Quantitative CT and inductively coupled plasma optical emission spectrometry (ICP-OES) results both confirm the presence of particles in the tumor 9 days post-injection (n = 8 mice/group). A significant difference is highlighted between citrate-GNP and BSA-GNP groups (** p < 0.005, Tukey’s multiple comparisons test), confirming that the protein corona of GNPs modifies intratumoral distribution and retention of the particles. In conclusion, our investigations show that the surface passivation of GNPs influences the mechanism of cellular uptake and intratumoral distribution in vivo, highlighting the spatial heterogeneity of the solid tumor.


Micromachines ◽  
2020 ◽  
Vol 11 (9) ◽  
pp. 861
Author(s):  
Elizabeth E. Niedert ◽  
Chenghao Bi ◽  
Georges Adam ◽  
Elly Lambert ◽  
Luis Solorio ◽  
...  

A microrobot system comprising an untethered tumbling magnetic microrobot, a two-degree-of-freedom rotating permanent magnet, and an ultrasound imaging system has been developed for in vitro and in vivo biomedical applications. The microrobot tumbles end-over-end in a net forward motion due to applied magnetic torque from the rotating magnet. By turning the rotational axis of the magnet, two-dimensional directional control is possible and the microrobot was steered along various trajectories, including a circular path and P-shaped path. The microrobot is capable of moving over the unstructured terrain within a murine colon in in vitro, in situ, and in vivo conditions, as well as a porcine colon in ex vivo conditions. High-frequency ultrasound imaging allows for real-time determination of the microrobot’s position while it is optically occluded by animal tissue. When coated with a fluorescein payload, the microrobot was shown to release the majority of the payload over a 1-h time period in phosphate-buffered saline. Cytotoxicity tests demonstrated that the microrobot’s constituent materials, SU-8 and polydimethylsiloxane (PDMS), did not show a statistically significant difference in toxicity to murine fibroblasts from the negative control, even when the materials were doped with magnetic neodymium microparticles. The microrobot system’s capabilities make it promising for targeted drug delivery and other in vivo biomedical applications.


2004 ◽  
Vol 36 (6) ◽  
pp. 419-424 ◽  
Author(s):  
Juan Ma ◽  
Xue-Ling Liao ◽  
Bin Lou ◽  
Man-Ping Wu

Abstract High density lipoprotein (HDL) binds lipopolysaccharide (LPS or endotoxin) and neutralizes its toxicity. We investigated the function of Apolipoprotein A-I (ApoA-I), a major apolipoprotein in HDL, in this process. Mouse macrophages were incubated with LPS, LPS+ApoA-I, LPS+ApoA-I+LFF (lipoprotein-free plasma fraction d>1.210 g/ml), LPS+HDL, LPS+HDL+LFF, respectively. MTT method was used to detect the mortality of L-929 cells which were attacked by the release-out cytokines in LPS-activated macrophages. It was found that ApoA-I significantly decreased L-929 cells mortality caused by LPS treatment (LPS vs. LPS+ApoA-I, P<0.05) and this effect became even more significant when LFF was utilized (LPS vs. LPS+ApoA-I+LFF, P<0.01; LPS vs. LPS+HDL+LFF, P<0.01). There was no significant difference between LPS+ApoA-I+LFF and LPS+HDL+LFF treatment, indicating that ApoA-I was the main factor. We also investigated in vivo effects of ApoA-I on mouse mortality rate and survival time after LPS administration. We found that the mortality in LPS+ApoA-I group (20%) and in LPS+ApoA-I+LFF group (10%) was significantly lower than that in LPS group (80%) (P<0.05, P<0.01, respectively); the survival time was (43.20 ± 10.13) h in LPS+ApoA-I group and (46.80 ± 3.79) h in LPS+ApoA-I+LFF group, which were significantly longer than that in LPS group (16.25 ± 17.28) h (P<0.01). We also carried out in vitro binding study to investigate the binding capacity of ApoA-I and ApoA-I+LFF to fluorescence labeled LPS (FITC-LPS). It was shown that both ApoA-I and ApoA-I+LFF could bind with FITC-LPS, however, the binding capacity of ApoA-I+LFF to FITC-LPS (64.47 ± 8.06) was significantly higher than that of ApoA-I alone (24.35 ± 3.70) (P<0.01). The results suggest that: (1) ApoA-I has the ability to bind with and protect against LPS; (2) LFF enhances the effect of ApoA-I; (3) ApoA-I is the major contributor for HDL anti-endotoxin function.


2017 ◽  
Vol 2017 ◽  
pp. 1-9 ◽  
Author(s):  
Jianru Pan ◽  
Huocong He ◽  
Ying Su ◽  
Guangjin Zheng ◽  
Junxin Wu ◽  
...  

GST-TAT-SOD was the fusion of superoxide dismutase (SOD), cell-permeable peptide TAT, and glutathione-S-transferase (GST). It was proved to be a potential selective radioprotector in vitro in our previous work. This study evaluated the in vivo radioprotective activity of GST-TAT-SOD against whole-body irradiation. We demonstrated that intraperitoneal injection of 0.5 ml GST-TAT-SOD (2 kU/ml) 2 h before the 6 Gy whole-body irradiation in mice almost completely prevented the splenic damage. It could significantly enhance the splenic antioxidant activity which kept the number of splenic white pulp and consequently resisted the shrinkage of the spleen. Moreover, the thymus index, hepatic antioxidant activity, and white blood cell (WBC) count of peripheral blood in irradiated mice pretreated with GST-TAT-SOD also remarkably increased. Although the treated and untreated irradiated mice showed no significant difference in the growth rate of animal body weight at 7 days postirradiation, the highest growth rate of body weight was observed in the GST-TAT-SOD-pretreated group. Furthermore, GST-TAT-SOD pretreatment increased resistance against 8 Gy whole-body irradiation and enhanced 30 d survival. The overall effect of GST-TAT-SOD seemed to be a bit more powerful than that of amifostine. In conclusion, GST-TAT-SOD would be a safe and potentially promising radioprotector.


1996 ◽  
Vol 63 (2) ◽  
pp. 257-267 ◽  
Author(s):  
Chun W. Wong ◽  
Geoffrey O. Regester ◽  
Geoffrey L. Francis ◽  
Dennis L. Watson

SummaryStudies on the immunomodulatory activities of ruminant milk and colostral whey fractions were undertaken. By comparing with boiled colostral whey in a preliminary experiment, a putative heat-labile immunostimulatory factor for antibody responses was found to be present in ovine colostral whey. Studies were then undertaken in sheep in which the efferent prefemoral lymphatic ducts were cannulated bilaterally, and immune responses in the node were measured following subcutaneous injection in the flank fold of whey protein preparations of various purities. A significant sustained decline of efferent lymphocyte output was observed following injection with autologous crude milk whey or colostral whey preparations, but no changes were observed in interferon-gamma levels in lymph plasma. Two bovine milk whey fractions (lactoperoxidase and lactoferrin) of high purity were compared in bilaterally cannulated sheep. A transient decline over the first 6 h was seen in the efferent lymphocyte output and lymph flow rate after injection of both fractions. A significant difference was seen between the two fractions in interferongamma levels in lymph at 6 h after injection. However, no significant changes in the proportion of the various efferent lymphocyte phenotypes were seen following either treatment. Whereas both fractions showed a significant inhibitory effect in a dose-dependent manner on the proliferative response of T lymphocytes, but not B lymphocytes, to mitogenic stimulation in vitro, no similar changes were seen following in vivo stimulation with these two fractions.


Sign in / Sign up

Export Citation Format

Share Document