Failure Analysis and Defect Inspection of Electronic Devices by High-Resolution Cathodoluminescence

Author(s):  
C. Monachon ◽  
M.S. Zielinski ◽  
D. Gachet ◽  
S. Sonderegger ◽  
S. Muckenhirn ◽  
...  

Abstract Quantitative cathodoluminescence (CL) microscopy is a new optical spectroscopy technique that measures electron beam-induced optical emission over large field of view with a spatial resolution close to that of a scanning electron microscope (SEM). Correlation of surface morphology (SE contrast) with spectrally resolved and highly material composition sensitive CL emission opens a new pathway in non-destructive failure and defect analysis at the nanometer scale. Here we present application of a modern CL microscope in defect and homogeneity metrology, as well as failure analysis in semiconducting electronic materials

2016 ◽  
Vol 33 (2) ◽  
pp. 94-101
Author(s):  
Kamil Janeczek ◽  
Aneta Arazna ◽  
Konrad Futera ◽  
Grazyna Koziol

Purpose The aim of this paper is to present non-destructive and destructive methods of failure analysis of epoxy moulded IC packages on the example of power MOSFETs in SOT-227 package. Design/methodology/approach A power MOSFET in SOT-227 package was examined twice using X-ray inspection, at first as the whole component to check if it is damaged and then after removing the upper part of package by mechanical grinding. The purpose of the second X-ray inspection was to prepare images for estimation of the total number and approximate location of voids in soft solder layers. Finally, power MOSFETs were subjected to decapsulation process using a concentrated sulphuric acid to verify existence of damage areas noticed during X-ray analysis and to observe other possible failures such as cracks in aluminium metallization or wires deformation. Findings X-ray analysis was revealed to be adequate technique to detect damage (e.g. meltings) in power MOSFETs in SOT-227 package, but only when tested components were analysed in the side view. This type of analysis combined with a graphic software is also suitable for voids estimation in soft solder layers. Moreover, it was found that a single acid (concentrated sulphuric acid) at elevated temperature can be successfully used for decapsulation of power MOSFETs in SOT-227 package without damage of aluminium metallization and aluminium wires. Such decapsulation process enables analysis of defects in wire, die and package materials. Research limitations/implications Further investigations are required to examine if the presented methods of failures analysis can be used for other types of components (e.g. high power resistors) in similar packages. Practical/implications The described methods of failure analysis can find application in electronic industry to select components which are free of damage and in effect which allow to produce high reliable devices. Apart from it, the presented method is applicable to evaluate reasons of improper work of tested electronic devices and to identify faked components. Originality/value This paper contains valuable information for research and technical staff involved in the assessment of electronic devices who needs practical methods of failure analysis of epoxy moulded IC packages.


Author(s):  
Yi-Sheng Lin ◽  
Yu-Hsiang Hsiao ◽  
Shu-Hua Lee

Abstract Electro Optical Terahertz Pulse Reflectometry (EOTPR) is an E-FA (Electrical Failure Analysis) technique in the semiconductor industry for non-destructive electrical fault isolation for shorts, leakages and opens. This paper introduces the capability and presents several case studies identifying the physical location of defects where EOTPR is useful as a non-destructive analysis technique. In this paper, the methodology and application of EOTPR on open and short failure isolations in advanced 2.5D IC and wafer level packages (WLP) have been presented. The experimental results of P-FA (Physical Failure Analysis) verify the accuracy of the EOTPR system in determining the distance to defect.


Author(s):  
Erick Kim ◽  
Kamjou Mansour ◽  
Gil Garteiz ◽  
Javeck Verdugo ◽  
Ryan Ross ◽  
...  

Abstract This paper presents the failure analysis on a 1.5m flex harness for a space flight instrument that exhibited two failure modes: global isolation resistances between all adjacent traces measured tens of milliohm and lower resistance on the order of 1 kiloohm was observed on several pins. It shows a novel method using a temperature controlled air stream while monitoring isolation resistance to identify a general area of interest of a low isolation resistance failure. The paper explains how isolation resistance measurements were taken and details the steps taken in both destructive and non-destructive analyses. In theory, infrared hotspot could have been completed along the length of the flex harness to locate the failure site. However, with a field of view of approximately 5 x 5 cm, this technique would have been time prohibitive.


Author(s):  
Bhanu Sood ◽  
Lucas Severn ◽  
Michael Osterman ◽  
Michael Pecht ◽  
Anton Bougaev ◽  
...  

Abstract A review of the prevalent degradation mechanisms in Lithium ion batteries is presented. Degradation and eventual failure in lithium-ion batteries can occur for a variety of dfferent reasons. Degradation in storage occurs primarily due to the self-discharge mechanisms, and is accelerated during storage at elevated temperatures. The degradation and failure during use conditions is generally accelerated due to the transient power requirements, the high frequency of charge/discharge cycles and differences between the state-of-charge and the depth of discharge influence the degradation and failure process. A step-by-step methodology for conducting a failure analysis of Lithion batteries is presented. The failure analysis methodology is illustrated using a decision-tree approach, which enables the user to evaluate and select the most appropriate techniques based on the observed battery characteristics. The techniques start with non-destructive and non-intrusive steps and shift to those that are more destructive and analytical in nature as information about the battery state is gained through a set of measurements and experimental techniques.


Author(s):  
Oliver D. Patterson ◽  
Deborah A. Ryan ◽  
Xiaohu Tang ◽  
Shuen Cheng Lei

Abstract In-line E-beam inspection may be used for rapid generation of failure analysis (FA) results for low yielding test structures. This approach provides a number of advantages: 1) It is much earlier than traditional FA, 2) de-processing isn’t required, and 3) a high volume of sites can be processed with the additional support of an in-line FIB. Both physical defect detection and voltage contrast inspection modes are useful for this application. Voltage contrast mode is necessary for isolation of buried defects and is the preferred approach for opens, because it is faster. Physical defect detection mode is generally necessary to locate shorts. The considerations in applying these inspection modes for rapid failure analysis are discussed in the context of two examples: one that lends itself to physical defect inspection and the other, more appropriately addressed with voltage contrast inspection.


Author(s):  
O. Diaz de Leon ◽  
M. Nassirian ◽  
C. Todd ◽  
R. Chowdhury

Abstract Integration of circuits on semiconductor devices with resulting increase in pin counts is driving the need for improvements in packaging for functionality and reliability. One solution to this demand is the Flip- Chip concept in Ultra Large Scale Integration (ULSI) applications [1]. The flip-chip technology is based on the direct attach principle of die to substrate interconnection.. The absence of bondwires clearly enables packages to become more slim and compact, and also provides higher pin counts and higher-speeds [2]. However, due to its construction, with inherent hidden structures the Flip-Chip technology presents a challenge for non-destructive Failure Analysis (F/A). The scanning acoustic microscope (SAM) has recently emerged as a valuable evaluation tool for this purpose [3]. C-mode scanning acoustic microscope (C-SAM), has the ability to demonstrate non-destructive package analysis while imaging the internal features of this package. Ultrasonic waves are very sensitive, particularly when they encounter density variations at surfaces, e.g. variations such as voids or delaminations similar to air gaps. These two anomalies are common to flip-chips. The primary issue with this package technology is the non-uniformity of the die attach through solder ball joints and epoxy underfill. The ball joints also present defects as open contacts, voids or cracks. In our acoustic microscopy study packages with known defects are considered. It includes C-SCAN analysis giving top views at a particular package interface and a B-SCAN analysis that provides cross-sectional views at a desired point of interest. The cross-section analysis capability gives confidence to the failure analyst in obtaining information from a failing area without physically sectioning the sample and destroying its electrical integrity. Our results presented here prove that appropriate selection of acoustic scanning modes and frequency parameters leads to good reliable correlation between the physical defects in the devices and the information given by the acoustic microscope.


Author(s):  
Sebastian Brand ◽  
Matthias Petzold ◽  
Peter Czurratis ◽  
Peter Hoffrogge

Abstract In industrial manufacturing of microelectronic components, non-destructive failure analysis methods are required for either quality control or for providing a rapid fault isolation and defect localization prior to detailed investigations requiring target preparation. Scanning acoustic microscopy (SAM) is a powerful tool enabling the inspection of internal structures in optically opaque materials non-destructively. In addition, depth specific information can be employed for two- and three-dimensional internal imaging without the need of time consuming tomographic scan procedures. The resolution achievable by acoustic microscopy is depending on parameters of both the test equipment and the sample under investigation. However, if applying acoustic microscopy for pure intensity imaging most of its potential remains unused. The aim of the current work was the development of a comprehensive analysis toolbox for extending the application of SAM by employing its full potential. Thus, typical case examples representing different fields of application were considered ranging from high density interconnect flip-chip devices over wafer-bonded components to solder tape connectors of a photovoltaic (PV) solar panel. The progress achieved during this work can be split into three categories: Signal Analysis and Parametric Imaging (SA-PI), Signal Analysis and Defect Evaluation (SA-DE) and Image Processing and Resolution Enhancement (IP-RE). Data acquisition was performed using a commercially available scanning acoustic microscope equipped with several ultrasonic transducers covering the frequency range from 15 MHz to 175 MHz. The acoustic data recorded were subjected to sophisticated algorithms operating in time-, frequency- and spatial domain for performing signal- and image analysis. In all three of the presented applications acoustic microscopy combined with signal- and image processing algorithms proved to be a powerful tool for non-destructive inspection.


Author(s):  
Andrew J. Komrowski ◽  
Luis A. Curiel ◽  
Daniel J. D. Sullivan ◽  
Quang Nguyen ◽  
Lisa Logan-Willams

Abstract The acquisition of reliable Acoustic Micro Images (AMI) are an essential non-destructive step in the Failure Analysis (FA) of electronic packages. Advanced packaging and new IC materials present challenges to the collection of reliable AMI signals. The AMI is complicated due to new technologies that utilize an increasing number of interfaces in ICs and packages. We present two case studies in which it is necessary to decipher the acoustic echoes from the signals generated by the interface of interest in order to acquire trustworthy information about the IC package.


Author(s):  
Hung-Sung Lin ◽  
Mong-Sheng Wu

Abstract The use of a scanning probe microscope (SPM), such as a conductive atomic force microscope (C-AFM) has been widely reported as a method of failure analysis in nanometer scale science and technology [1-6]. A beam bounce technique is usually used to enable the probe head to measure extremely small movements of the cantilever as it is moved across the surface of the sample. However, the laser beam used for a beam bounce also gives rise to the photoelectric effect while we are measuring the electrical characteristics of a device, such as a pn junction. In this paper, the photocurrent for a device caused by photon illumination was quantitatively evaluated. In addition, this paper also presents an example of an application of the C-AFM as a tool for the failure analysis of trap defects by taking advantage of the photoelectric effect.


Author(s):  
Teoh King Long ◽  
Ko Yin Fern

Abstract In time domain reflectometry (TDR), the main emphasis lies on the reflected waveform. Poor probing contact is one of the common problems in getting an accurate waveform. TDR probe normalization is essential before measuring any TDR waveforms. The advantages of normalization include removal of test setup errors in the original test pulse and the establishment of a measurement reference plane. This article presents two case histories. The first case is about a Plastic Ball Grid Array package consisting of 352 solder balls where the open failure mode was encountered at various terminals after reliability assessment. In the second, a three-digit display LED suspected of an electrical short failure was analyzed using TDR as a fault isolation tool. TDR has been successfully used to perform non-destructive fault isolation in assisting the routine failure analysis of open and short failure. It is shown to be accurate and reduces the time needed to identify fault locations.