scholarly journals Biotreatment of Winery Wastewater Using a Hybrid System Combining Biological Trickling Filters and Constructed Wetlands

2020 ◽  
Vol 10 (2) ◽  
pp. 619
Author(s):  
Christos S. Akratos ◽  
Triantafyllos I. Tatoulis ◽  
Athanasia G. Tekerlekopoulou

The objective of this work was to determine the ability of a pilot-scale hybrid system to treat real (non-synthetic) winery wastewater. The experimental treatment system consisted of two stages: An attached growth pilot-scale bioreactor (biological trickling filter with plastic support material) was initially used to remove a significant amount of dissolved chemical oxygen demand (d-COD) from winery wastewater, and then a pilot-scale, horizontal subsurface flow constructed wetland (CW) was examined as a post-treatment step for further d-COD removal. Results from the biofilter revealed that the recirculation rate of 1.0 L/min lead to higher d-COD removal rates than that of 0.5 L/min for all feed d-COD concentrations tested (3500, 7500, 9000 and 18,000 mg d-COD/L). Experiments in the CW were performed using feed d-COD concentrations of about 1500 mg/L (equivalent to biofilter effluent when initial filter feed d-COD concentrations are 18,000 mg/L). The wetland polishing stage managed to further remove d-COD and produced effluent concentrations below current legislation limits for safe disposal. Furthermore, the presence of zeolite in CW (one third of the length of CW) enhanced ammonium removal. The experimental results indicate that the combination of a biological trickling filter and a constructed wetland could effectively treat effluents originating from small wineries typical of the Mediterranean region.

2015 ◽  
Vol 71 (7) ◽  
pp. 1088-1096 ◽  
Author(s):  
B. Kim ◽  
M. Gautier ◽  
G. Olvera Palma ◽  
P. Molle ◽  
P. Michel ◽  
...  

The aim of this study was to characterize the efficiency of an intensified process of vertical flow constructed wetland having the following particularities: (i) biological pretreatment by trickling filter, (ii) FeCl3 injection for dissolved phosphorus removal and (iii) succession of different levels of redox conditions along the process line. A pilot-scale set-up designed to simulate a real-scale plant was constructed and operated using real wastewater. The influences of FeCl3 injection and water saturation level within the vertical flow constructed wetland stage on treatment performances were studied. Three different water saturation levels were compared by monitoring: suspended solids (SS), total phosphorus (TP), dissolved chemical oxygen demand (COD), ammonium, nitrate, phosphate, iron, and manganese. The results confirmed the good overall efficiency of the process and the contribution of the trickling filter pretreatment to COD removal and nitrification. The effects of water saturation level and FeCl3 injection on phosphorus removal were evaluated by analysis of the correlations between the variables. Under unsaturated conditions, good nitrification and no denitrification were observed. Under partly saturated conditions, both nitrification and denitrification were obtained, along with a good retention of SSs. Finally, under saturated conditions, the performance was decreased for almost all parameters.


2000 ◽  
Vol 41 (1) ◽  
pp. 163-166 ◽  
Author(s):  
W. Gebert ◽  
P.A. Wilderer

The investigated effects of heating the filling material in trickling filters were carried out at the Ingolstadt wastewater treatment plant, Germany. Two pilot scale trickling filters were set up. Heat exchanger pipings were embedded in the filter media of one of these trickling filters, and the temperature in the trickling filter was raised. The other trickling filter was operated under normal temperature conditions, and was used as a control. The results clearly demonstrate that the performance of trickling filters cannot be constantly improved by heating the biofilm support media. A sustained increase of the metabolic rates did not occur. The decrease of the solubility of oxgen in water and mass transfer limitations caused by an increase of the biofilm thickness are the main reasons for that. Thus, the heating of trickling filters (e.g. by waste heat utilization) in order to increase the capacity of trickling filters under cold weather conditions cannot be recommended.


Author(s):  
Ahmad Zuhairi Abdullah ◽  
Mohamad Hakimi Ibrahim ◽  
Mohd. Omar Ab. Kadir

Kertas kerja ini membincangkan tentang kecekapan penuras cucur dalam merawat supernatan kumbahan kilang kelapa sawit (POME). Supernatan POME diperoleh menerusi dua jenis perawatan. Dalam perawatan 1, pengendapan graviti digunakan untuk menyingkir pepejal boleh mendak. Perawatan 2 digunakan untuk menyingkir pepejal boleh mendak dan gumpalan partikal dengan menggunakan 350 ppm alum. Influen dialurkan secara titisan pada biojisim yang terlekat pada penyokong pepejal rawak PVC setinggi 1 m. Penuras cucur berupaya menyingkir lebih daripada 90.0% dari keperluan oksigen biologi (BOD) dan keperluan oksigen kimia (COD) di bawah 1 m3/m2–hari. Pada 2.53 m3/m2–hari, influen dengan Perawatan 1 menghasilkan kecekapan penyingkiran COD sebanyak 40.3%, berbanding 83.1% bila Perawatan 2 digunakan. Perkara ini berlaku berikutan penyingkiran bahan organik tak boleh resap semasa Perawatan 2. Kecekapan penyingkiran menurun dengan meningkatnya bebanan hidraulik kerana wujudnya kelemahan dalam hidrolisis bahan tak boleh resap kepada substratum larut. Dengan edaran semula (α=1), penyingkiran BOD dan COD yang lebih tinggi dicapai di bawah 7 m3/m2–hari. Pencapaian ini disebabkan oleh bebanan organik yang lebih rendah serta pergedaran semula enzim dan biojisim yang aktif kepada sistem. Perawatan 2 menghasilkan enap cemar yang lebih tinggi kerana penukaran substratum boleh larut kepada biojisim tak boleh larut. Hidrolisis bahan organik tak boleh resap didapati berlaku secara aktif pada bahagian atas penuras cucur sementara bahagian bawahnya cenderung mengoksidakan substratum organik. Kata kunci: POME, turas cucur, bahan organik bolehresap, penggumpalan, alir semula This paper discusses the efficiency of a trickling filter to treat Palm Oil Mill Effluent (POME) supernatants. POME supernatants were obtained via two treatments. In Treatment 1, gravity sedimentation was used to remove settleable solids. In Treatment 2, both settleable solids and colloidal particles were removed using 350 ppm of alum. The influents were allowed to trickle over biomass attached to 1 m high random PVC solid support. Below 1 m3/m2–day, the filter demonstrated Biological Oxygen Demand (BOD) and Chemical Oxygen Demand (COD) removal efficiencies of more than 90.0%. At 2.53 m3/m2–day, the influent with Treatment 1 gave a COD removal efficiency of 40.3%, but increased to 83.1% when the influent with Treatment 2 was used. This was ascribed to the removal of non–diffusible organics during Treatment 2. The removal efficiencies decreased with an increase in hydraulic loading due to limitations in the hydrolysis of non–diffusibles into soluble substrates. With recirculation (α=1), higher BOD and COD removals were achieved below 7.0 m3/m2–day, attributed to lower organic loading and the recycling of active enzyme and biomass to the system. The influent with Treatment 2 demonstrated higher sludge production due to higher conversion of soluble substrates into insoluble biomass. Hydrolysis of non–diffusible organics mainly took place at upper reaches of the filter column while lower reaches were involved in oxidizing the organic subtrates. Key words: POME, trickling filter, diffusible organic, coagulation, recirculation


Processes ◽  
2019 ◽  
Vol 7 (7) ◽  
pp. 418 ◽  
Author(s):  
Pedro Cisterna-Osorio ◽  
Verónica Lazcano-Castro ◽  
Gisela Silva-Vasquez ◽  
Mauricio Llanos-Baeza ◽  
Ignacio Fuentes-Ortega

The objective of this work is to evaluate the impact of innovative modifications made to conventional effluent capture and discharge devices used in subsurface flow wetlands (SSFW). The main modifications that have been developed extend the influence of the capture and discharge device in such a way that the SSFW width and height are fully covered. This improved innovative device was applied and evaluated in two subsurface flow wetlands, one on a pilot scale and one on a real scale. To evaluate the impact of the innovative device with respect to the conventional one in the operational functioning of subsurface flow wetlands, the elimination of chemical oxygen demand (COD) was measured and compared. The results show that for the innovative device, the COD removal was 10% higher than for the conventional device, confirming the validity and effectiveness of the modifications implemented in the effluent capture and discharge devices used in SSFW.


2019 ◽  
Vol 80 (6) ◽  
pp. 1145-1154
Author(s):  
Agyemang Richard Osei ◽  
Yacouba Konate ◽  
Felix Kofi Abagale

Abstract Constructed wetland technology is an innovative engineering technique for faecal sludge (FS) management. The presence of emergent macrophytes enhances the important processes of evapotranspiration, sludge mineralisation, and contaminant reduction. Consequently, selecting a species that can withstand the difficult sludge contaminated conditions within a local context is vital. This study monitored the pollutant removal potentials and growth dynamics of Bambusa vulgaris and Cymbopogon nardus as promising macrophytes for the constructed wetland technology in the Sudano-Sahelian context. The experiment, at pilot scale, consisted of plastic reactors (27 litre) filled with filter media of sand and fine gravels at the base, and planted with the selected species. Pollutant removal efficiencies were evaluated based on differences between influent and effluent concentrations, and physiological growth parameters of plant height, number of leaves and number of plants were monitored monthly. Total annual sludge loading rate of 31.4 and 103.4 kg TS/(m2·yr) (TS: total solids) were determined for FS + wastewater (acclimatisation phase) and FS load respectively. Both species recorded appreciable pollutant removal efficiency >80% for the organic (chemical oxygen demand), nutrients (PO43_P and NH4-N) and solid (total suspended solids and total volatile solids) contents. The species thus demonstrated satisfactory performance of resistance for faecal polluted wetland conditions.


2010 ◽  
Vol 37 (3) ◽  
pp. 496-501 ◽  
Author(s):  
K.N. Njau ◽  
M. Renalda

A horizontal subsurface flow constructed wetland (HSSFCW) was employed to remove tannins from the effluent of a tannins extracting company. Two HSSFCW cells with hydraulic retention time (HRT) of 9 d and packed with limestone were used. One cell without macrophytes was used as a control, while the second cell was planted with Phragmites mauritianus . Results indicated that HSSFCW was capable of treating tannin wastewater that has been seeded with primary facultative pond sludge. Tannins and chemical oxygen demand (COD) removal efficiency of 95.9% and 90.6% with outlet concentration of 27 mg/L and 86 mg/L, respectively, were obtained in the planted cell; while the tannins and COD removal efficiency of 91.1% and 89.5% with outlet concentration of 57 mg/L and 96 mg/L, respectively, were obtained in the control cell.


2014 ◽  
Vol 69 (7) ◽  
pp. 1410-1418 ◽  
Author(s):  
Weijie Guo ◽  
Zhu Li ◽  
Shuiping Cheng ◽  
Wei Liang ◽  
Feng He ◽  
...  

To examine the performance of a constructed wetland system on stormwater runoff and domestic sewage (SRS) treatment in central east China, two parallel pilot-scale integrated constructed wetland (ICW) systems were operated for one year. Each ICW consisted of a down-flow bed, an up-flow bed and a horizontal subsurface flow bed. The average removal rates of chemical oxygen demand (CODCr), total suspended solids (TSS), ammonia (NH4+-N), total nitrogen (TN) and total phosphorus (TP) were 63.6, 91.9, 38.7, 43.0 and 70.0%, respectively, and the corresponding amounts of pollutant retention were approximately 368.3, 284.9, 23.2, 44.6 and 5.9 g m−2 yr−1, respectively. High hydraulic loading rate (HLR) of 200 mm/d and low water temperatures (<15 °C) resulted in significant decrease in removals for TP and NH4+-N, but had no significant effects on removals of COD and TSS. These results indicated that the operation of this ICW at higher HLR (200 mm/d) might be effective and feasible for TSS and COD removal, but for acceptable removal efficiencies of nitrogen and phosphorus it should be operated at lower HLR (100 mm/d). This kind of ICW could be employed as an effective technique for SRS treatment.


Author(s):  
Maria Cristina Collivignarelli ◽  
Marco Carnevale Miino ◽  
Franco Hernan Gomez ◽  
Vincenzo Torretta ◽  
Elena Cristina Rada ◽  
...  

In the coming years, water stress is destined to worsen considering that the consumption of water is expected to increase significantly, and climate change is expected to become more evident. Greywater (GW) has been studied as an alternative water source in arid and semiarid zones. Although there is no single optimal solution in order to treat GW, constructed wetlands proved to be effective. In this paper, the results of the treatment of a real GW by a horizontal flow constructed wetland (HFCW) for more than four months are shown. In the preliminary laboratory-scale plant, Phragmites australis, Carex oshimensis and Cyperus papyrus were tested separately and showed very similar results. In the second phase, pilot-scale tests were conducted to confirm the performance at a larger scale and evaluate the influence of hydraulic retention time, obtaining very high removal yields on turbidity (>92%), total suspended solids (TSS) (>85%), chemical oxygen demand (COD) (>89%), and five-day biological oxygen demand (BOD5) (>88%). Based on the results of the pilot-scale HFCW, a comparison with international recommendations by World Health Organization and European Union is discussed.


2007 ◽  
Vol 56 (2) ◽  
pp. 95-102 ◽  
Author(s):  
L. Rodríguez ◽  
J. Villaseñor ◽  
I.M. Buendía ◽  
F.J. Fernández

The aim of this study was to evaluate the feasibility of the re-use of the winery wastewater to enhance the biological nutrient removal (BNR) process. In batch experiments it was observed that the addition of winery wastewater mainly enhanced the nitrogen removal process because of the high denitrification potential (DNP), of about 130 mg N/g COD, of the contained substrates. This value is very similar to that obtained by using pure organic substrates such as acetate. The addition of winery wastewater did not significantly affect either phosphorus or COD removal processes. Based on the experimental results obtained, the optimum dosage to remove each mg of N–NO3 was determined, being a value of 6.7 mg COD/mg N–NO3. Because of the good properties of the winery wastewater to enhance the nitrogen removal, the viability of its continuous addition in an activated sludge pilot-scale plant for BNR was studied. Dosing the winery wastewater to the pilot plant a significant increase in the nitrogen removal was detected, from 58 to 75%. The COD removal was slightly increased, from 89 to 95%, and the phosphorus removal remained constant.


Sign in / Sign up

Export Citation Format

Share Document