scholarly journals Phonocardiography Signals Compression with Deep Convolutional Autoencoder for Telecare Applications

2020 ◽  
Vol 10 (17) ◽  
pp. 5842
Author(s):  
Ying-Ren Chien ◽  
Kai-Chieh Hsu ◽  
Hen-Wai Tsao

Phonocardiography (PCG) signals that can be recorded using the electronic stethoscopes play an essential role in detecting the heart valve abnormalities and assisting in the diagnosis of heart disease. However, it consumes more bandwidth when transmitting these PCG signals to remote sites for telecare applications. This paper presents a deep convolutional autoencoder to compress the PCG signals. At the encoder side, seven convolutional layers were used to compress the PCG signals, which are collected on the patients in the rural areas, into the feature maps. At the decoder side, the doctors at the remote hospital use the other seven convolutional layers to decompress the feature maps and reconstruct the original PCG signals. To confirm the effectiveness of our method, we used an open accessed dataset on PHYSIONET. The achievable compress ratio (CR) is 32 when the percent root-mean-square difference (PRD) is less than 5%.

JMS SKIMS ◽  
2017 ◽  
Vol 20 (2) ◽  
pp. 90-95
Author(s):  
Noorul Amin

Background: The present age is the age of stress. Everybody is disturbed due to one or the other reason irrespective of their age. However, adolescents are more prone to psychological and sociological disturbances.Objectives:To assess the psychosocial problems in adolescents.Methods: The study was conducted in selected schools of urban and rural areas taking 100 participants each for boys and girls using convenient sampling method. The tool used was youth self report. The data collected was analyzed using appropriate statistical methods.Results: The study revealed that 48.5% adolescents were well adjusted; 47% were having mild psychosocial problems; 4% had moderate psychosocial problems and 0.5% had severe psychosocial problems.Conclusion: Adolescents irrespective of their living places had varying degrees of psychosocial problems. JMS 2017; 20 (2):90-95


Symmetry ◽  
2021 ◽  
Vol 13 (4) ◽  
pp. 717
Author(s):  
Mariia Nazarkevych ◽  
Natalia Kryvinska ◽  
Yaroslav Voznyi

This article presents a new method of image filtering based on a new kind of image processing transformation, particularly the wavelet-Ateb–Gabor transformation, that is a wider basis for Gabor functions. Ateb functions are symmetric functions. The developed type of filtering makes it possible to perform image transformation and to obtain better biometric image recognition results than traditional filters allow. These results are possible due to the construction of various forms and sizes of the curves of the developed functions. Further, the wavelet transformation of Gabor filtering is investigated, and the time spent by the system on the operation is substantiated. The filtration is based on the images taken from NIST Special Database 302, that is publicly available. The reliability of the proposed method of wavelet-Ateb–Gabor filtering is proved by calculating and comparing the values of peak signal-to-noise ratio (PSNR) and mean square error (MSE) between two biometric images, one of which is filtered by the developed filtration method, and the other by the Gabor filter. The time characteristics of this filtering process are studied as well.


Sensors ◽  
2021 ◽  
Vol 21 (10) ◽  
pp. 3311
Author(s):  
Riccardo Ballarini ◽  
Marco Ghislieri ◽  
Marco Knaflitz ◽  
Valentina Agostini

In motor control studies, the 90% thresholding of variance accounted for (VAF) is the classical way of selecting the number of muscle synergies expressed during a motor task. However, the adoption of an arbitrary cut-off has evident drawbacks. The aim of this work is to describe and validate an algorithm for choosing the optimal number of muscle synergies (ChoOSyn), which can overcome the limitations of VAF-based methods. The proposed algorithm is built considering the following principles: (1) muscle synergies should be highly consistent during the various motor task epochs (i.e., remaining stable in time), (2) muscle synergies should constitute a base with low intra-level similarity (i.e., to obtain information-rich synergies, avoiding redundancy). The algorithm performances were evaluated against traditional approaches (threshold-VAF at 90% and 95%, elbow-VAF and plateau-VAF), using both a simulated dataset and a real dataset of 20 subjects. The performance evaluation was carried out by analyzing muscle synergies extracted from surface electromyographic (sEMG) signals collected during walking tasks lasting 5 min. On the simulated dataset, ChoOSyn showed comparable performances compared to VAF-based methods, while, in the real dataset, it clearly outperformed the other methods, in terms of the fraction of correct classifications, mean error (ME), and root mean square error (RMSE). The proposed approach may be beneficial to standardize the selection of the number of muscle synergies between different research laboratories, independent of arbitrary thresholds.


Author(s):  
Tsu-Wang Shen ◽  
Shan-Chun Chang

Abstract Purpose Although electrocardiogram (ECG) has been proven as a biometric for human identification, applying biometric technology remains challenging with diverse heart rate circumstances in which high intensity heart rate caused waveform deformation may not be known in advance when ECG templates are registered. Methods A calibration method that calculates the ratio of the length of an unidentified electrocardiogram signal to the length of an electrocardiogram template is proposed in this paper. Next, the R peak is used as an axis anchor point of a trigonometric projection (TP) to attain the displacement value. Finally, the unidentified ECG signal is calibrated according to the generated trigonometric value, which corresponds to the trigonometric projection degree of the ratio and the attained displacement measurement. Results The results reveal that the proposed method provides superior overall performance compared with that of the conventional downsampling method, based on the percentage root mean square difference (PRD), correlation coefficients, and mean square error (MSE). Conclusion The curve fitting equation directly maps from the heart rate levels to the TP degree without prior registration information. The proposed ECG calibration method offers a more robust system against heart rate interference when conducting ECG identification.


1995 ◽  
Vol 74 (6) ◽  
pp. 2665-2684 ◽  
Author(s):  
Y. Kondoh ◽  
Y. Hasegawa ◽  
J. Okuma ◽  
F. Takahashi

1. A computational model accounting for motion detection in the fly was examined by comparing responses in motion-sensitive horizontal system (HS) and centrifugal horizontal (CH) cells in the fly's lobula plate with a computer simulation implemented on a motion detector of the correlation type, the Reichardt detector. First-order (linear) and second-order (quadratic nonlinear) Wiener kernels from intracellularly recorded responses to moving patterns were computed by cross correlating with the time-dependent position of the stimulus, and were used to characterize response to motion in those cells. 2. When the fly was stimulated with moving vertical stripes with a spatial wavelength of 5-40 degrees, the HS and CH cells showed basically a biphasic first-order kernel, having an initial depolarization that was followed by hyperpolarization. The linear model matched well with the actual response, with a mean square error of 27% at best, indicating that the linear component comprises a major part of responses in these cells. The second-order nonlinearity was insignificant. When stimulated at a spatial wavelength of 2.5 degrees, the first-order kernel showed a significant decrease in amplitude, and was initially hyperpolarized; the second-order kernel was, on the other hand, well defined, having two hyperpolarizing valleys on the diagonal with two off-diagonal peaks. 3. The blockage of inhibitory interactions in the visual system by application of 10-4 M picrotoxin, however, evoked a nonlinear response that could be decomposed into the sum of the first-order (linear) and second-order (quadratic nonlinear) terms with a mean square error of 30-50%. The first-order term, comprising 10-20% of the picrotoxin-evoked response, is characterized by a differentiating first-order kernel. It thus codes the velocity of motion. The second-order term, comprising 30-40% of the response, is defined by a second-order kernel with two depolarizing peaks on the diagonal and two off-diagonal hyperpolarizing valleys, suggesting that the nonlinear component represents the power of motion. 4. Responses in the Reichardt detector, consisting of two mirror-image subunits with spatiotemporal low-pass filters followed by a multiplication stage, were computer simulated and then analyzed by the Wiener kernel method. The simulated responses were linearly related to the pattern velocity (with a mean square error of 13% for the linear model) and matched well with the observed responses in the HS and CH cells. After the multiplication stage, the linear component comprised 15-25% and the quadratic nonlinear component comprised 60-70% of the simulated response, which was similar to the picrotoxin-induced response in the HS cells. The quadratic nonlinear components were balanced between the right and left sides, and could be eliminated completely by their contralateral counterpart via a subtraction process. On the other hand, the linear component on one side was the mirror image of that on the other side, as expected from the kernel configurations. 5. These results suggest that responses to motion in the HS and CH cells depend on the multiplication process in which both the velocity and power components of motion are computed, and that a putative subtraction process selectively eliminates the nonlinear components but amplifies the linear component. The nonlinear component is directionally insensitive because of its quadratic non-linearity. Therefore the subtraction process allows the subsequent cells integrating motion (such as the HS cells) to tune the direction of motion more sharply.


2008 ◽  
Vol 19 (6) ◽  
pp. 2661-2672 ◽  
Author(s):  
Soomin Shim ◽  
Samuel A. Merrill ◽  
Phyllis I. Hanson

The AAA+ ATPase VPS4 plays an essential role in multivesicular body biogenesis and is thought to act by disassembling ESCRT-III complexes. VPS4 oligomerization and ATPase activity are promoted by binding to LIP5. LIP5 also binds to the ESCRT-III like protein CHMP5/hVps60, but how this affects its function remains unclear. Here we confirm that LIP5 binds tightly to CHMP5, but also find that it binds well to additional ESCRT-III proteins including CHMP1B, CHMP2A/hVps2–1, and CHMP3/hVps24 but not CHMP4A/hSnf7–1 or CHMP6/hVps20. LIP5 binds to a different region within CHMP5 than within the other ESCRT-III proteins. In CHMP1B and CHMP2A, its binding site encompasses sequences at the proteins' extreme C-termini that overlap with “MIT interacting motifs” (MIMs) known to bind to VPS4. We find unexpected evidence of a second conserved binding site for VPS4 in CHMP2A and CHMP1B, suggesting that LIP5 and VPS4 may bind simultaneously to these proteins despite the overlap in their primary binding sites. Finally, LIP5 binds preferentially to soluble CHMP5 but instead to polymerized CHMP2A, suggesting that the newly defined interactions between LIP5 and ESCRT-III proteins may be regulated by ESCRT-III conformation. These studies point to a role for direct binding between LIP5 and ESCRT-III proteins that is likely to complement LIP5's previously described ability to regulate VPS4 activity.


2012 ◽  
Vol 602-604 ◽  
pp. 776-780
Author(s):  
Zhi Qiang Li ◽  
Mei Li ◽  
Wei Jia Fan

Poly(3-hydroxybutyrate-co-4-hydroxybutyrate)copolymer [P(3HB-co-4HB)] is a kind of biodegradable high molecular polymer produced by bioaccumulation. Because of the good biodegradability and biocompatibility, P(3HB-co-4HB)s have attracted wide attention . At first, the intrinsic viscosity[η] in good solvent of P(3HB-co-4HB) s with varying contents of 4HB was investigated in different temperature. Second, observed the changes of crystallization gathered state caused by the varying contents of 4HB by polarizing microscope. The results show that to the P(3HB-co-4HB)s in same molecular weight, the intrinsic viscosity[η] in good solvent barely changes when the mole fractions of 4HB increase. On the other hand, the mean square end to end distances[0] of macromolecular flexible chains increase with the mole fractions of 4HB. At the same time, the states of aggregation change from spherulites to dendrites. In this investigation, we discuss the reasons of the differences in depth.


2006 ◽  
Vol 188 (3) ◽  
pp. 1205-1210 ◽  
Author(s):  
A. E. Sikora ◽  
R. Zielke ◽  
K. Datta ◽  
J. R. Maddock

ABSTRACT It was previously reported that unlike the other obg/cgtA GTPases, the Vibrio harveyi cgtAV is not essential. Here we show that cgtAV was not disrupted in these studies and is, in fact, essential for viability. Depletion of CgtAV did not result in cell elongation. CgtAV is associated with the large ribosomal particle. In light of our results, we predict that the V. harveyi CgtAV protein plays a similar essential role to that seen for Obg/CgtA proteins in other bacteria.


Author(s):  
He L ◽  
◽  
Jia X ◽  
Yu L ◽  
◽  
...  

Type 1 Diabetes (T1D) is one of the most common chronic diseases in childhood, which is caused by destruction of insulinproducing pancreatic beta cells. Its incidence increases 3-5% annually and doubles every 20 years [1,2]. On one hand, acute and chronic complications of T1D seriously affect the quality of life and even life span of patients. On the other hand, prognosis can greatly be improved when the disease prediction and closely monitoring are applied, leading to earlier diagnosis and treatment [3]. Islet Autoantibodies (IAbs), as most reliable biomarkers at present for islet autoimmunity, precede clinical T1D by years and play an essential role in prediction and clinical diagnosis of T1D [4,5].


1991 ◽  
Vol 69 (7) ◽  
pp. 433-441 ◽  
Author(s):  
Jack Ferrier ◽  
Angela Kesthely ◽  
Eva Lagan ◽  
Conrad Richter

A model for cytosolic Ca2+ spikes is presented that incorporates continual influx of Ca2+, uptake into an intracellular compartment, and Ca2+-induced Ca2+ release from the compartment. Two versions are used. In one, release is controlled by explicit thresholds, while in the other, release is a continuous function of cytosolic and compartmental [Ca2+]. Some model predictions are as follows. Starting with low Ca2+ influx and no spikes: (1) induction of spiking when Ca2+ influx is increased. Starting with spikes: (2) increase in magnitude and decrease in frequency when influx is reduced; (3) inhibition of spiking if influx is greatly reduced; (4) decrease in the root-mean-square value when influx is increased; and (5) elimination of spiking if influx is greatly increased. Since there is good evidence that hyperpolarizing spikes reflect cytosolic Ca2+ spikes, we used electrophysiological measurements to test the model. Each model prediction was confirmed by experiments in which Ca2+ influx was manipulated. However, the original spike activity tended to return within 5–30 min, indicating a cellular resetting process.Key words: calcium, electrophysiology, mathematical modelling.


Sign in / Sign up

Export Citation Format

Share Document