scholarly journals Corrosion Resistance Test of Electroplated Gold and Palladium Using Fast Electrochemical Analysis

Coatings ◽  
2019 ◽  
Vol 9 (6) ◽  
pp. 405
Author(s):  
Walter Giurlani ◽  
Patrick Marcantelli ◽  
Francesco Benelli ◽  
Daniele Bottacci ◽  
Filippo Gambinossi ◽  
...  

Noble metal coatings are commonly employed to improve corrosion resistance of metals in the electronic and jewellery industry. The corrosion resistance of electroplated goods is currently determinate with long, destructive and almost subjective interpretation corrosion tests in artificial atmosphere. In this study we present the application of electrochemical analysis to obtain fast and numerical information of the antiaging coating. We performed open circuit potential (OCP) and corrosion current measurement; we employed also the electrochemical impedance spectroscopy (EIS), commonly applied to organic or passivated metal with high-impedance, to find the best option for noble low-impedance coating analysis. For comparison, traditional standardized tests (damp heat ISO 17228, salt spray ISO 9227 and sulphur dioxide ISO 4524) were also performed.

Coatings ◽  
2019 ◽  
Vol 9 (11) ◽  
pp. 724 ◽  
Author(s):  
Zhang ◽  
Hong ◽  
Lin ◽  
Zheng

The corrosion behavior of unsealed and sealed high-velocity oxygen-fuel (HVOF)-sprayed nanostructured WC-CoCr cermet coatings under different corrosive environments was investigated using scanning electron microscopy (SEM), open circuit potential (OCP), potentiodynamic polarization and electrochemical impedance spectroscopy (EIS). Ultrasonic excitation sealing with aluminum phosphate was performed in an external ultrasonic bath with the frequency of 40 kHz at atmospheric pressure and room temperature. SEM micrographs revealed that the exposed area of the coating was effectively reduced by the coverage of aluminum phosphate sealant on the majority of pores. Electrochemical measurements demonstrated that the sealant with the help of ultrasonic energy could shift the corrosion potential to a more noble direction, reduce the corrosion current density, increase the resistance of charge transfer, and effectively improve the corrosion resistance of the coating in both 3.5 wt % NaCl and 1 mol·L−1 HCl solutions.


Coatings ◽  
2018 ◽  
Vol 8 (12) ◽  
pp. 454 ◽  
Author(s):  
Arman Dastpak ◽  
Kirsi Yliniemi ◽  
Mariana de Oliveira Monteiro ◽  
Sarah Höhn ◽  
Sannakaisa Virtanen ◽  
...  

In this study, a waste of biorefinery—lignin—is investigated as an anticorrosion coating on stainless steel. Corrosion behavior of two lignin types (hardwood beech and softwood spruce) was studied by electrochemical measurements (linear sweep voltammetry, open circuit potential, potentiostatic polarization, cyclic potentiodynamic polarization, and electrochemical impedance measurements) during exposure to simulated body fluid (SBF) or phosphate buffer (PBS). Results from linear sweep voltammetry of lignin-coated samples, in particular, demonstrated a reduction in corrosion current density between 1 and 3 orders of magnitude cf. blank stainless steel. Furthermore, results from cross cut adhesion tests on lignin-coated samples demonstrated that the best possible adhesion (grade 0) of ISO 2409 standard was achieved for the investigated novel coatings. Such findings suggest that lignin materials could transform the field of organic coatings towards more sustainable alternatives by replacing non-renewable polymer coatings.


2019 ◽  
Vol 66 (6) ◽  
pp. 819-826
Author(s):  
Khashayar Tabi ◽  
Mansour Farzam ◽  
Davood Zaarei

Purpose Potassium silicate sealer was applied on solvent-cleaned, acid-pickled, dacromet-coated steel to improve its corrosion resistance. The purpose of this paper is to study the corrosion behavior of dacromet-coated steel. Design/methodology/approach Potassium silicate sealer was applied on solvent-cleaned, acid-pickled, dacromet-coated steel to improve its corrosion resistance. Electrochemical impedance spectroscopy (EIS), potentiodynamic polarization, scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS) and salt spray were carried out. SEM was used to study the morphological appearance of the surface. Findings The EIS behavior indicated that solvent-cleaned dacromet-coated steel sealed with potassium silicate showed that the corrosion current density was 2.664E − 5 A.cm2 which was reduced to 8.752E − 6 A.cm2 and the corrosion rate, which was 2.264E − 2 mm.year−1, was reduced to 7.438E − 3 mm.year−1 in NaCl 3.5 wt.per cent. EIS was used in NaCl 3.5 wt.%, and the Bode plot characteristics showed that the corrosion protection of solvent-cleaned, dacromet-coated steel was enhanced when sealed with potassium silicate. The EDS results of salt-sprayed, solvent-cleaned samples after 10 days indicated that the main corrosion products are composed of SiO2, ZnO and Al2O3. Research limitations/implications The detection of Li element in EDS was not possible because of the device limitation. Originality/value The current paper provides new information about the sealing properties of potassium silicate and its effects on the corrosion resistance of dacromet coating, which is widely used in many industries such as the automobile industry.


2010 ◽  
Vol 95 ◽  
pp. 79-83
Author(s):  
Amir Eliezer

Micro-arc oxidization of AM50 magnesium alloys was studied. The influence of micro-arc oxidization process was investigated; phase structure were analyzed using X-ray diffraction (XRD). Open circuit potential (OCP) and electrochemical impedance spectroscopy (EIS) were used to evaluate the corrosion resistance of ceramic coatings formed on magnesium alloys under stress conditions. XRD analyses indicate that the ceramic coatings fabricated on the surface of magnesium alloys by micro-arc oxidization are composed of spinel phase MgAl2O4 The corrosion resistance of ceramic coatings is improved compared with magnesium alloy substrate.


2015 ◽  
Vol 61 (2) ◽  
pp. 117-120
Author(s):  
Costin Coman ◽  
◽  
Raluca Monica Comăneanu ◽  
Violeta Hâncu ◽  
Horia Mihail Barbu ◽  
...  

Objectives. In this study we evaluated corrosion resistance of three types of metal alloys (two NiCr and one CoCr). Methods. Samples (coded A, B, C) of circular shape, with dimensions 13 x 1.5 mm, sanded and polished, were introduced in Fusayama Meyer artificial saliva at pH 5.2 and 37 ± 0.5°C and tested in terms of corrosion resistance with a potentiostat/galvanostat (model 4000 PARSTAT, Princeton Applied Research). Results. Open circuit potential EOC [mV] ranged between 21.316 and 5.75. Corrosion potential Ecor [mV] was between -73.536 and -395.662, and the corrosion current density icor [A/cm2] was between 1.237 x 10-6 and 905.13 x 10-9. Conclusion. The best corrosion behavior in Fusayama Meyer artificial saliva at pH 5.2 and at a temperature of 37 ± 0.5°C is the alloy A, followed by the alloy C.


2008 ◽  
Vol 59 (9) ◽  
Author(s):  
Daniel Mareci ◽  
Igor Cretescu ◽  
Neculai Aelenei ◽  
Julia Claudia Mirza Rosca

The electrochemical behavior of a three Ag-Pd alloys used in dental prosthetics construction for crowns and bridges was studied in artificial saliva using the polarization curves and electrochemical impedance spectroscopy (EIS). The corrosion resistance was evaluated by means of the corrosion currents value and by coulometric analysis. The open circuit potential of Ag-Pd are attributed to dealloying followed by surface enrichment with Ag and the possible formation of an insoluble AgCl surface film on the respective alloy surfaces. Our results have shown that these alloys have a somewhat good corrosion resistance in artificial saliva. When increasing the content of Cu, corrosion resistance decreases. The passivation of all samples occurred spontaneously at the open circuit potential. The electrochemical properties of the spontaneously passivated electrodes at the open circuit potential were studied by EIS. The polarization resistance (Rp) and the electrode capacitance (Cdl) were determined. The polarisation resistance of all the samples increases with the immersion time. The polarization resistances are largest and decrease when increasing the content of Cu. Cu reduces the Ag-Pd alloy corrosion resistance. The present study, thought limited, has shown that electrochemical characteristics can be use to identify such alloys. Knowledge of the in vitro corrosion behaviour of these alloys may lead to better understanding of any biologically adverse effects in vitro.


2013 ◽  
Vol 537 ◽  
pp. 67-70
Author(s):  
Feng Zhang ◽  
Chuan Bing Huang ◽  
Wei Liu ◽  
Kui Zhou ◽  
Wen Ting Zhang ◽  
...  

Ni/BN and NiCrAl/BN abradable sealing coatings used in turbo engines were prepared by plasma spray technology. The phases and the microstructures of the coatings were characterized with X-ray diffraction (XRD) and scanning electron microscopy (SEM). Corrosion behaviors of these coatings were investigated with open-circuit potential (OCP) and salt spray corrosion test. The results showed that the NiCrAl/BN possess better corrosion resistance as compared with Ni/BN.


2013 ◽  
Vol 634-638 ◽  
pp. 2935-2938
Author(s):  
You Bin Wang ◽  
Jian Min Zeng

The corrosion property of three currently used hot dipped alloys (Al-8Si, Zn-0.6Ni and 55Al-Zn-Si) immersed in 3.5% NaCl solution were studied by analyzing the open circuit potential variation with time and electrochemical impedance spectroscopy (EIS) tests. The open circuit potential of the Al-8Si alloy is 100mV higher than the potential of Zn-0.6Ni and 55Al-Zn-Si, and the potential of Zn-0.6Ni is approach to the 55Al-Zn-Si alloy. The phase angles of the Al-8Si, 55Al-Zn-Si and Zn-0.6Ni are close to -80°,-70°,-60°, and the high impedance values at low frequencies are 105,104,103 Ω cm2, respectively. The EIS spectra of the alloys indicated two relaxation time constants. An “equivalent circuit” with the circuit elements representing the electrochemical properties was proposed to simulate the EIS spectra, and the simulated dates were in a good agreement with the experiment dates. The polarization resistance (Rp) of Al-8Si, 55Al-Zn-Si and Zn-0.6Ni are 18000, 2010, 251 Ω•cm-2, respectively. The results showed that the corrosion property of Al-8Si is well than the other alloys in the test solution.


2015 ◽  
Vol 2015 ◽  
pp. 1-18 ◽  
Author(s):  
J. Porcayo-Calderon ◽  
R. A. Rodriguez-Diaz ◽  
E. Porcayo-Palafox ◽  
J. Colin ◽  
A. Molina-Ocampo ◽  
...  

The effect of Cu addition on the electrochemical corrosion behavior of Ni3Al intermetallic alloy was investigated by potentiodynamic polarization, open-circuit potential, linear polarization resistance, and electrochemical impedance spectroscopy in 1.0 M H2SO4solution. Performance of the pure elements (Cu, Ni, and Al) was also evaluated. In general, Cu addition improved the corrosion resistance of Ni3Al. Electrochemical measurements show that corrosion resistance of Ni3Al-1Cu alloy is lower than that of other intermetallic alloys and pure elements (Ni, Cu, and Al) in 1.0 M H2SO4solution at 25°C. Surface analysis showed that the Ni3Al alloys are attacked mainly through the dendritic phases, and Cu addition suppresses the density of dendritic phases.


2016 ◽  
Vol 710 ◽  
pp. 216-221 ◽  
Author(s):  
Wagner Izaltino Alves Dos Santos ◽  
Isolda Costa ◽  
Célia Regina Tomachuk

New treatments for replacement of chromate require lower toxicity and corrosion protection. This study aims to investigate the influence of the combination of a Ce conversion coating (CCCe) with glycol molecules on the corrosion resistance of the AA2024-T3 clad (AA1230). The corrosion resistance of surface treated and untreated samples was evaluated by electrochemical techniques (electrochemical impedance spectroscopy, polarization tests and open circuit potential). These tests were complemented by salt spray tests to accelerate the corrosive effects of weathering. The surfaces were analyzed after corrosion tests by scanning electron microscopy with X-ray energy dispersive detector (SEM - EDX). The results of the CCCe samples in combination with glycol were compared with that of the surface with chromate layer and the results showed that the CCCe treatment is a candidate for replacement of chromating with the advantage that it does not generate toxic residues. The self-healing capacity of the new treatment tested was indicated by the increased formation of corrosion products deposition on top of Fe rich intermetallis in the AA1230 clad with time of exposure to the electrolyte.