scholarly journals Wearable Flexible Antenna for UWB On-Body and Implant Communications

Telecom ◽  
2021 ◽  
Vol 2 (3) ◽  
pp. 285-301
Author(s):  
Mariella Särestöniemi ◽  
Marko Sonkki ◽  
Sami Myllymäki ◽  
Carlos Pomalaza-Raez

This paper describes the development and evaluation of an on-body flexible antenna designed for an in-body application, as well as on-body communications at ISM and UWB frequency bands. The evaluation is performed via electromagnetic simulations using the Dassault Simulia CST Studio Suite. A planar tissue layer model, as well as a human voxel model from the human abdominal area, are used to study the antenna characteristics next to human tissues. Power flow analysis is presented to understand the power flow on the body surface as well as within the tissues. Simulation results show that this wearable flexible antenna is suitable for in-body communications in the intestinal area, e.g., for capsule endoscopy, in the industrial, scientific, and medical (ISM) band and at lower ultra-wideband (UWB). At higher frequencies, the antenna is suitable for on-body communications as well as in-body communications with lower propagation depth requirements. Additionally, an antenna prototype has been prepared and the antenna performance is verified with several on-body measurements. The measurement results show a good match with the simulation results. The novelty of the proposed antenna is a compact size and the flexible substrate material, which makes it feasible and practical for several different medical diagnosis and monitoring applications.

2017 ◽  
Vol 9 (8) ◽  
pp. 1559-1567 ◽  
Author(s):  
Roshanak Elyassi ◽  
Gholamreza Moradi

In this paper, we present a novel flexible moon-shaped slot implantable antenna for neural recording systems and head implants. It covers both medical Industrial, Scientific and Medical band (2.45 GHz) and impulse ratio ultra-wideband (IR-UWB) frequency range (3.1–10.6 GHz) for forward and backward telemetry applications. It has a simple and miniaturized structure in comparison with the antennas reported in the other researches. Furthermore, for adapting with natural curvature of human head, a flexible substrate is chosen with a good antenna performance under the bending. The proposed antenna is analyzed in a multi-layer box model of head tissues to speed up the antenna design procedures. On the basis of the simulation results, we achieved the good impedance matching over the desired frequency range (S11below −10 dB). Far-field characteristics are considered, as well. The directivity is in suitable range for UWB short-range communications and its mean value is 3.84 dBi. Finally, to take into account patents’ safety regulations and the effective isotropic radiated power restriction in the desired frequency range, the maximum power of transmitter has been calculated. A phantom containing a mixture of sugar and water is used to test the fabricated antenna. The measured parameters are well matched to the full-wave simulation results.


2008 ◽  
Vol 15 (1) ◽  
pp. 51-60 ◽  
Author(s):  
C.Q. Liu

In this paper, an improved FRF-based substructure synthesis method combined with power flow analysis is presented and is used for performing a vehicle axle noise analysis. The major transfer paths of axle noise transmitted from chassis to vehicle body are identified and ranked based on power flows transmitted through bushings between the chassis and body. To calculate the power flows, it is necessary to know the reaction forces and the vibrations at the bushing locations on the body side. To this end, the body is represented in terms of experimentally derived frequency response functions (FRF's) at the bushing locations, and the FRF's are coupled with the FEA model of the chassis for performing a total system dynamic analysis. This paper also describes how the FRF's of the vehicle body and the frequency dependent stiffness data of the bushings can be combined together with a simple formulation to better represent the dynamic characteristics of a full vehicle. A classical example is used to illustrates the concept of the method, and the method is then applied to a vehicle axle noise analysis with detailed procedure. The theoretical predictions are compared with experimentally measured results. Good correlation has been obtained.


Energies ◽  
2021 ◽  
Vol 14 (8) ◽  
pp. 2237
Author(s):  
Grzegorz Filo ◽  
Edward Lisowski ◽  
Janusz Rajda

The article presents results of research on an adjustable check valve. In particular, the article deals with improvement of flow characteristics and reduction in pressure losses of an existing valve design. The subject of the research was the valve body in the form of a steel block intended for mounting a typical cartridge valve insert. Two variants of the valve body were analysed: a standard one, which is currently in production, and the proposed new solution, in which the geometry was modified based on the results of CFD simulations. The main research task was to properly shape and arrange holes and flow channels inside the body, between the cartridge valve and the connecting plate. Using CFD analyses, a solution for minimising the flow resistance was sought and then the method of modifying flow channels geometry was developed. The CFD simulation results showed a significant reduction in pressure loss, up to 40%. The obtained simulation results were verified on a test bench using a prototype of the proposed valve block. A high degree of consistency in the results of CFD simulations and laboratory experiments was achieved. The relative difference between simulation and experimental results in the entire considered range of the flow rate did not exceed 6.0%.


2021 ◽  
Vol 10 (3) ◽  
pp. 1739-1746
Author(s):  
S. M. Shah ◽  
A. A. Rosman ◽  
M. A. Z. A. Rashid ◽  
Z. Z. Abidin ◽  
F. C. Seman ◽  
...  

In this work, a compact dual-band semi-flexible antenna operating at         2.45 GHz and 5.8 GHz for the industrial, scientific and medical (ISM) band is presented. The antenna is fabricated on a semi-flexible substrate material, Rogers Duroid RO3003™ with a low-profile feature with dimensions of 30×38 mm2 which makes it a good solution for wearable applications. Bending investigation is also performed over a vacuum cylinder and the diameters are varied at 50 mm, 80 mm and 100 mm, that represents the average human arm’s diameter. The bending investigation shows that reflection coefficients for all diameters are almost similar which imply that the antenna will operate at the dual-band resonant frequencies, even in bending condition. The simulated specific absorption rate (SAR) in CST MWS® software shows that the antenna obeys the FCC and ICNIRP guidelines for 1 mW of input power. The SAR limits at 2.45 GHz for 1 g of human tissue is simulated at 0.271 W/kg (FCC standard: 1.6 W/kg) while for 10 g is at 0.0551 W/kg (ICNIRP standard: 2 W/kg. On the other hand, the SAR limits at 5.8 GHz are computed at 0.202 W/kg for 1 g and 0.0532 W/kg for 10 g.


Author(s):  
J. S. Norbakyah ◽  
A. R. Salisa

A study on plug-in hybrid electric recreational boat (PHERB) powertrain with a special energy management strategy modeling and analysis was presented in this paper. Firstly, the boat components are sized to meet the expected power and energy requirements through a power flow analysis. Then, the model is tested numerically in the MATLAB/SIMULINK environment using the existing driving cycle. The accuracy of the model is verified by a comparison of the component between the simulation results from PHERB and advanced vehicle simulator (ADVISOR) software. The simulation results of component, fuel economy and emission of PHERB and hybrid electric vehicle models in ADVISOR are compared.


2020 ◽  
Vol 35 (9) ◽  
pp. 1030-1036
Author(s):  
Pronami Bora ◽  
Pokkunuri Pardhasaradhi ◽  
Boddapati Madhav

A non-planar electromagnetic band gap (EBG) structured antenna is proposed in this paper for wireless communication applications. The proposed design consists of coplanar waveguide (CPW) fed square patch antenna embedded with triangular EBG backing on FR-4 substrate material for 2.4 GHz (Wi-Fi, LTE) and 5.2 GHz (WLAN) applications. Gain is improved from 2.8 dB to 13.9 dB by adding EBG structure in the proposed antenna and the parametric analysis is done for optimizing the antenna performance characteristics. The proposed antenna provides a maximum efficiency of 82.5% in the resonating frequencies. The prototyped antenna is having good correlation with the simulation results obtained from Finite Element Method (FEM) based Anyss-HFSS. High Frequency Structure Simulator is used to analyze the antenna parameters and the simulated and measured results are correlating well with each other with a slight change in frequencies.


Sensors ◽  
2021 ◽  
Vol 21 (11) ◽  
pp. 3737
Author(s):  
Nitin Kathuria ◽  
Boon-Chong Seet

Noncontact monitoring of human vital signs has been an emerging research topic in recent years. A key approach to this monitoring is the use of the Doppler radar concept which enables real-time vital signs detection, resulting in a new class of radar system known as bio-radar. The antennas are a key component of any bio-radar module and their designs should meet the common requirements of bio-radar applications such as high radiation directivity and mechanical flexibility. This paper presents the design of a four-element antenna array on a flexible liquid crystal polymer (LCP) substrate of 100 μm thickness and εr of 3.35. The designed antenna array can be used with a 24 GHz bio-radar for vital signs monitoring in a non-contact manner. It features a relatively compact size of 36.5 × 53 mm2 and measured gain of 5.81 dBi. The two vital signs: breathing rate (BR) and heart rate (HR) of two human subjects are detected with relatively good accuracy using the fabricated antenna array and radio frequency (RF) output power of −3 dBm from a distance of approximately 60 cm. The effect of bending on the antenna performance is also analyzed.


2021 ◽  
Vol 51 (2) ◽  
Author(s):  
Zhengrui He ◽  
Jie Jin

A flexible and compact coplanar waveguide feed (CPW-fed) wearable antenna is introduced for wireless wearable communications applications at the industrial scientific medical (ISM) band. The proposed antenna consists of copper, which is used as the radiation patch and ground planes printed on the same side of polyimide flexible substrate. The overall size of the antenna is 30 mm × 28 mm × 0.08 mm, the results show that the antenna can transmit and receive signals in two frequency bands of 1.89–2.67 GHz and 3.02–3.23 GHz, in which radiating properties are characterized and agree well with the simulation results. The antenna is bent in different directions to further investigate the reflection coefficient and corresponding effect on the antenna under bending. The center frequency of the antenna is slightly shifted towards higher and lower frequencies when antenna is bent in X-axis and Y-axis, respectively. Furthermore, the wearability of the antenna is verified when the antenna is placed on different parts of the human body such as wrist and chest. Hence, the proposed flexible antenna is a suitable candidate for wearable wireless communication applications.


2021 ◽  
Vol 11 (5) ◽  
pp. 7531-7535
Author(s):  
M. O. Dwairi

In this paper, a semi-circular ultra-wideband antenna has been modified according to the 2×1 and 2×2 MIMO scenarios. The proposed antennas were designed based on the FR-4 substrate material with dimensions of 36×50mm and 60×60mm for 2×1 and 2×2 scenarios respectively. Simulation results show that a gain improvement of the proposed MIMO antennas from 1 to 2.5dB has been achieved in comparison with the single patch antenna. The radiation pattern for the original and the proposed 2×2 MIMO antennas are exhibited. The main advantage of the proposed antennas is that the gain improves without the need to increase the operating power. This makes the proposed MIMO antennas suitable to be used for UWB antenna applications.


Author(s):  
Poonam Thanki ◽  
Falguni Raval

Aims: This paper presents the development of Co-Planar Waveguide (CPW) fed dualband, compact, and flexible antenna. The antenna is designed on flexible substrate jeans; so, it is suitable for wearable applications. <p></p> Objectives: The proposed antenna generates dual-band at 3.36GHz –3.61GHz and at 5.01 GHz – 5.18 GHz. The antenna has a compact size of 40×30 mm2. The antenna consists of a rectangular patch having a slot which is responsible for the first band and slot in the ground plane which is responsible for the second band. <p></p> Methods: By optimizing the dimensions, the antenna gives dual-band at 3.5 GHz and 5.1 GHz with impedance bandwidth of 250 MHz and 170 MHz, respectively. The performance of the antenna such as gain and radiation pattern over the operating band has been also discussed. <p></p> Conclusion: This proposed antenna with the first band at 3.5GHz is suitable for Wi-MAX (Worldwide Interoperability for Microwave Access) and second band at 5.1GHz is suitable for Higher Wireless Local Area Network applications (WLAN). <p></p>


Sign in / Sign up

Export Citation Format

Share Document