scholarly journals Comparative Study Regarding the Surface Roughness of Highly Viscous Flowable Composites After Immersion in Acidic Drinks

2019 ◽  
Vol 70 (6) ◽  
pp. 2010-2014
Author(s):  
Irina Nica ◽  
Simona Stoleriu ◽  
Galina Pancu ◽  
Adriana Munteanu ◽  
Claudiu Topoliceanu ◽  
...  

The aim of the present study was to assess, by profilometry, the effect of different immersion regimes in Coca-Cola drink on the surface roughness of two highly viscous flowable composite resins. The studied materials were Gradia Direct LoFlo (GC Corporation,Tokyo, Japan) and Micro Esthetic flow-viscous (Bisico, Germany). Fifteen cylindrical samples having the of 5 mm and the thickness of 2 mm were made from each material using plastic molds placed on glass plates. The samples were light-cured for 40s on both sides through the glass plates, to ensure complete polymerization of the material. They were divided into two groups as follows: Group I. Gradia Direct LoFlo and Group II. Micro Esthetic flow-viscous. Specimens of each group were then randomly divided into 5 subgroups. In subgroup A (control group) 4 samples were kept only in artificial saliva. In subgroups B-E (each having 4 samples) the samples were immersed in Coca-Cola drink according to 4 different protocols. The mean values of roughness parameters, Ra, were calculated. The Kolmogorov-Smirnov normality test was used to determine the distribution of data in groups. ANOVA and Tukey post hoc statistical tests were used to compare the results from the groups. For both materials, the highest surface roughness was determined for the samples that were submerged 7 times/day in Coca Cola. The assessment of surface microstructure of the samples, after immersion, revealed for both materials a statistically significant increase of Ra values.

2018 ◽  
Vol 4 (1) ◽  
pp. 15
Author(s):  
Afiatul Mukarromah ◽  
Irfan Dwiandhono ◽  
Dian Noviyanti Agus Imam

Demineralization is a process of partial or full tooth mineral loss which caused by acidic environment, for example the side effect of extracoronal bleaching treatment. Demineralization increases enamel surface roughness which leads plaque accumulation. Whey extract and calcium phosphopeptide-amorphous calcium phophate (CPP-ACP) contain calcium and phosphate that can stop the demineralization through remineralization process. This study aimed to determine the differences of enamel surface roughness after whey extract and CPP-ACP application post- extracoronal bleaching. Experimental laboratory with pre- and post-test control group design was performed on 24 first maxillary premolars which devided into 3 groups. On group I, specimens were immersed in artificial saliva. Specimens in group II were immersed in whey extract meanwhile specimens were immersed in CPP-ACP on group III. Whey extract and CPP-ACP immersions were conducted 10 minutes every 12 hours for 15 days. The enamel surface roughness test was performed twice, after extracoronal bleaching treatment and after 15 days remineralization agent application. This study result indicated significant differences between group I and group II and between group I and group III (p<0.05), but there was no significant difference between group II and group III (p>0.05). This study showed whey extract decreased more enamel surface roughness than CPP-ACP but the difference was not significant statistically. So, whey extract and CPP-ACP showed similar remineralization potential.


2017 ◽  
Vol 8 (3) ◽  
pp. 196-201 ◽  
Author(s):  
K Pradeep

ABSTRACT Aim The aim was to compare the effect of 10 and 20% carbamide peroxide (CP) on microhardness (MHN) and surface roughness of two commercially available bulk fill composites (X-tra fill Bulk Fill and Tetric EvoCeram Bulk Fill). Materials and methods A total of 50 specimens with both type composites were prepared using brass molds of inner diameter 10 mm and a height of 4 mm. Each type of composite was further divided into three groups, control group stored in artificial saliva for 14 days, other groups bleached with 10 and 20% CP respectively, for 14 days. Microhardness of the composite resin was tested with a Vickers hardness tester, whereas surface roughness was tested with profilometer. Results All the analysis was performed using Statistical Package for the Social Sciences version 18. The value of p < 0.05 was considered statistically significant. Both 10 and 20% CP significantly reduced MHN of experimental composite resins. However, the mean surface roughness was significantly higher in X-tra fill Bulk Fill than Tetric EvoCeram Bulk Fill at 20% CP concentration. The mean MHN of Tetric EvoCeram was reduced when compared with X-tra fill at 20% CP. Conclusion There was a significant reduction in the MHN of restorative materials observed after exposure to CP under a clinically simulated bleaching regimen. However, increase in surface roughness was seen only at 20% CP. Clinical significance The physical properties, such as MHN and surface roughness have a crucial effect on the longevity of restorations and, moreover, on the esthetic demands of patients, but they may be compromised by bleaching treatments. The aim of this research paper was to assess the reaction of home bleaching agents on the physical properties of two Bulk Fill composite resin restorative materials. How to cite this article Francis G, Pradeep K, Ginjupalli K, Saraswathi V. Effects of Bleaching Agents on the Microhardness and Surface Roughness of Bulk Fill Composites. World J Dent 2017;8(3):196-201.


2018 ◽  
Vol 69 (7) ◽  
pp. 1871-1875
Author(s):  
Galina Pancu ◽  
Simona Stoleriu ◽  
Nicoleta Tofan ◽  
Irina Nica ◽  
Cristina Angela Ghiorghe ◽  
...  

The study was performed to investigate the changes induced by mechanical-chemical action of a bleaching product on dental enamel and to assess the effect of some remineralization products containing calcium, phosphate, and fluoride applied in conjunction with the bleaching product by surface roughness analysis using profilometry. Forty tooth samples were randomly divided in three study groups and a control group. In control group (group IV) the samples were maintained in artificial saliva. The study groups were as follows: group I-samples submitted to bleaching procedure using Opalustre (3 times a day, 1minute each), group II-samples submitted to remineralization and then to whitening, group III-samples submitted to remineralization, whitening and then remineralization. The surface roughness was determined in relation to a reference surface using Portable Surface Roughness Measuring Tester SJ-210 (Mitutoyo, America Corporation, USA). The bleaching system Opalustre increased the roughness of enamel and the product that contains calcium, phosphate and fluoride applied before and after bleaching improved the roughness parameters.


2021 ◽  
Vol 6 (1) ◽  
pp. 44
Author(s):  
Dewi Puspitasari ◽  
Diana Wibowo

ABSTRACTBioactive composite resin is the newest restorative resin material which has good mechanical and aesthetic properties. In the oral cavity, the restoration is degraded due to exposure to acids, one of which is exposure to asthma drugs. Properties of composite resins that can be affected by degradation include surface roughness. This study aims to analyze salbutamol sulfate exposure to the surface roughness of bioactive resins. The research method used was pure experimental design with post test-only with control design. The study used 39 specimens of bioactive resin (8 mm in diameter and 2 mm in thickness), divided into 3 treatment groups, namely the 400µg salbutamol sulfate exposure group, the 800µg salbutamol sulfate exposure group and the artificial saliva control group with treatment every 24 hours for 7 days, subsequently the specimens are tested with the surface roughness of the composite resin using a surface roughness tester. The highest surface roughness value was found in the 800µg group (8.23 ± 0.98 µm), followed by 400 µg group (5.43 ± 1.16 µm) and the lowest in the artificial saliva group (2.63 ± 0.82 µm). There were significant differences in all treatment groups. The exposure of salbutamol sulfate affects the surface roughness of the bioactive composite resin, a higher number of exposure doses indicates a higher surface roughness value.Keywords: bioactive composite resins, salbutamol sulfate, surface roughness


2012 ◽  
Vol 24 (1) ◽  
Author(s):  
Rori Sasmita ◽  
Rahmi Alma Farah Adang ◽  
Opik Taofik Hidayat

The change of the tooth colour could be restored with bleaching. The tooth bleaching will affects the surface roughness of the composite resins. Recently, the material basis for composite resins has developed, among others are methacrylate-based and silorane based composite resins. The objective of this study was to distinguish the surface roughness value of methacrylate-based composite resin and silorane based composite resins. This research was quasi-experimental. The sample used in this study were methacrylate and silorane based composite resins in discs form, with the size of 6 mm and the thickness of 3 mm, manufactured into 20 specimens and divided into 2 groups. The control group was immersed in the artificial saliva, and the treatment group was applied with 40% hydrogen peroxide. The result of the experiment analyzed using unpaired sample t-test showed significant differences in the average value of the surface roughness after the application of 40% hydrogen peroxide. The average value of methacrylate and silorane based composite resins were 2.744 μm and 3.417 μm, respectively. There was a difference in the surface roughness of methacrylate and silorane based composite resin compounds after the application of 40% hydrogen peroxide. The surface roughness value of the silorane-based composite resin was higher than the methacrylate-based.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Philipp Körner ◽  
Luca Georgis ◽  
Daniel B. Wiedemeier ◽  
Thomas Attin ◽  
Florian J. Wegehaupt

Abstract Background This in-vitro-study aimed to evaluate the potential of different fluoride gels to prevent gastroesophageal reflux induced erosive tooth wear. Methods Surface baseline profiles of a total of 50 bovine enamel specimens [randomly assigned to five groups (G1–5)] were recorded. All specimens were positioned in a custom made artificial oral cavity and perfused with artificial saliva (0.5 ml/min). Reflux was simulated 11 times a day during 12 h by adding HCl (pH 3.0) for 30 s (flow rate 2 ml/min). During the remaining 12 h (overnight), specimens were stored in artificial saliva and brushed twice a day (morning and evening) with a toothbrush and toothpaste slurry (15 brushing strokes). While specimens in the control group (G1) did not receive any further treatment, specimens in G2–5 were coated with different fluoride gels [Elmex Gelée (G2); Paro Amin Fluor Gelée (G3); Paro Fluor Gelée Natriumfluorid (G4); Sensodyne ProSchmelz Fluorid Gelée (G5)] in the evening for 30 s. After 20 days, surface profiles were recorded again and enamel loss was determined by comparing them with the baseline profiles. The results were statistically analysed using one-way analysis of variance (ANOVA) followed by Tukey`s HSD post-hoc test. Results The overall highest mean wear of enamel (9.88 ± 1.73 µm) was observed in the control group (G1), where no fluoride gel was applied. It was significantly higher (p < 0.001) compared to all other groups. G2 (5.03 ± 1.43 µm), G3 (5.47 ± 0.63 µm, p = 0.918) and G4 (5.14 ± 0.82 µm, p > 0.999) showed the overall best protection from hydrochloric acid induced erosion. Enamel wear in G5 (6.64 ± 0.86 µm) was significantly higher compared to G2 (p = 0.028) and G4 (p = 0.047). Conclusions After 20 days of daily application, all investigated fluoride gels are able to significantly reduce gastroesophageal reflux induced loss of enamel.


2013 ◽  
Vol 07 (02) ◽  
pp. 165-171 ◽  
Author(s):  
Duygu Tuncer ◽  
Emel Karaman ◽  
Esra Firat

ABSTRACT Objective: To investigate the effect of beverages′ temperature on the surface roughness, hardness, and color stability of a composite resin. Materials and Methods: Fifty specimens of the Filtek Z250 composite (3M ESPE, Dental Products, St.Paul, MN, USA) were prepared and initial roughness, microhardness, and color were measured. Then the specimens were randomly divided into five groups of 10 specimens each: Coffee at 70°C, coffee at 37°C, cola at 10°C, cola at 37°C, and artificial saliva (control). After the samples were subjected to 15 min × 3 cycles per day of exposure to the solutions for 30 days, the final measurements were recorded. Results: After immersion in beverages, the artificial saliva group showed hardness values higher than those of the other groups (P < 0.001) and the microhardness values were significantly different from the initial values in all groups except for the control group. Both cola groups showed roughness values higher than the baseline values (P < 0.05), while the other groups showed values similar to the baseline measurements. When ΔE measurements were examined, the 70°C coffee group showed the highest color change among all the groups (P < 0.05). Conclusion: High-temperature solutions caused alterations in certain properties of composites, such as increased color change, although they did not affect the hardness or roughness of the composite resin material tested.


2016 ◽  
Vol 10 (02) ◽  
pp. 170-175 ◽  
Author(s):  
Gabriela Migliorin da Rosa ◽  
Luciana Mendonça da Silva ◽  
Márcio de Menezes ◽  
Hugo Felipe do Vale ◽  
Diego Ferreira Regalado ◽  
...  

ABSTRACT Objectives: The present study verified the influence of whitening dentifrices on the surface roughness of a nanohybrid composite resin. Materials and Methods: Thirty-two specimens were prepared with Filtek™ Z350 XT (3M/ESPE) and randomly divided into four groups (n = 08) that were subjected to brushing simulation equivalent to the period of 1 month. The groups assessed were a control group with distilled water (G1), Colgate Total 12 Professional Clean (G2), Sensodyne Extra Whitener Extra Fresh (G3), and Colgate Luminous White (G4). A sequence of 90 cycles was performed for all the samples. The initial roughness of each group was analyzed by the Surface Roughness Tester (TR 200-TIME Group Inc., CA, USA). After the brushing period, the final roughness was measured, and the results were statistically analyzed using nonparametric Kruskal–Wallis and Dunn tests for intergroup roughness comparison in the time factor. For intragroup and “Δ Final − Initial” comparisons, the Wilcoxon test and (one-way) ANOVA were, respectively, performed (α = 0.05). Results: The roughness mean values before and after brushing showed no statistically significant difference when the different dentifrices were used. None of the dentifrices analyzed increased significantly the nanohybrid composite resin surface roughness in a 1 month of tooth brushing simulation. Conclusions: These results suggest that no hazardous effect on the roughness of nanohybrid composite resin can be expected when whitening dentifrices are used for a short period. Similar studies should be conducted to analyze other esthetic composite materials.


2019 ◽  
Vol 44 (3) ◽  
pp. 281-288 ◽  
Author(s):  
KY Kyaw ◽  
M Otsuki ◽  
MS Segarra ◽  
N Hiraishi ◽  
J Tagami

SUMMARY Objective: To investigate the effect of calcium-phosphate–based desensitizers, Teethmate AP paste (TMAP) and Teethmate Desensitizer (TMD) (Kuraray Noritake Dental, Tokyo, Japan), on the prevention of staining on acid-eroded enamel. Methods and Materials: Forty polished enamel samples (4×4×1 mm) from bovine incisors were randomly divided into five groups (n=8). After immersion in 50 mL of 0.5% citric acid (pH 2.5) for 15 minutes to form acid-eroded surfaces, the surfaces were subjected to different treatments with TMAP, TMD, and NaF (0.21% means 950 ppm) for five minutes. Another eroded group was not treated with desensitizer. For the control group, the samples were not eroded or treated. All the samples were stored in artificial saliva (AS) at pH 7.2 for 24 hours at 37°C. The TMAP, TMD, or NaF was reapplied at eight and 16 hours during the 24 hours of storage time. The surface roughness (Sa) was evaluated following ISO 25178 for surface texture using confocal laser scanning microscopy (VK-X 150 series, Keyence, Osaka, Japan) before acid erosion, after acid erosion, and after 24 hours of incubation in AS. Afterward, the color difference was measured with a dental colorimeter (Shade Eye NCC, Shofu, Kyoto, Japan) before and after staining with tea solution. Results: One-way repeated measures analysis of variance showed that acid erosion significantly increased Sa (p&lt;0.001). TMAP- and TMD-treated groups exhibited lower Sa values than the NaF group and the no-desensitizer treatment group. The greatest staining was observed in the NaF group and the no-desensitizer group, while the TMAP and TMD groups significantly decreased the formation of stains. Conclusions: Acid-eroded enamel increased surface roughness and tended to absorb more stains. However, the application of TMAP and TMD moderated the roughness and thus prevented the formation of extrinsic stains.


2019 ◽  
Vol 2019 ◽  
pp. 1-6 ◽  
Author(s):  
Yagthan Mohammed Haider ◽  
Zainab Salih Abdullah ◽  
Ghasak H. Jani ◽  
Norehan Mokhtar

Maxillofacial silicone elastomers are used to replace and reconstruct missing facial parts for patients with trauma or a certain disease. Although commonly favorable silicone elastomers are not ideal in properties, many studies have been carried out to improve their mechanical properties and to come out with ideal maxillofacial prosthetic materials, so as to render patients with the best maxillofacial prostheses. The aim of the current study is to evaluate the effect of addition of different concentrations of polyester powder on hardness, tear strength, surface roughness, and tensile strength of maxillofacial A-2186 RTV silicone elastomers. Polyester powder was added to the silicone elastomer in the concentrations of 1%, 3% and 5% by using an electronic digital balance, compared with the control group of 0% polyester filler. The shore A hardness test was done according to ASTM D 2240 standards. The tear test was done according to ASTM D624 type C standards. The tensile test was done according to ISO specification number 37:2011. The surface roughness test was performed according to ISO 7619-1 2010 specifications. The data collected were then analyzed using one-way analysis of variance (ANOVA) and post hoc and Fisher’s LSD tests. All three groups showed a highly significant increase in tear strength, tensile strength, hardness, and roughness, compared to the control group. Reinforcement of A-2186 Platinum RTV Silicone Elastomer with 5% polyester significantly improved the mechanical properties tested in this study.


Sign in / Sign up

Export Citation Format

Share Document