scholarly journals ACME: An Automated Tool for Generating and Evaluating the Quality of VoIP Calls

Author(s):  
Leandro C. G. Lustosa ◽  
André A. D. P. Souza ◽  
Paulo H. de A. Rodrigues ◽  
Douglas G. Quinellato
Keyword(s):  
Diagnostics ◽  
2019 ◽  
Vol 9 (1) ◽  
pp. 8 ◽  
Author(s):  
Laura Zanella-Calzada ◽  
Carlos Galván-Tejada ◽  
Nubia Chávez-Lamas ◽  
M. Gracia-Cortés ◽  
Rafael Magallanes-Quintanar ◽  
...  

Depression is a mental disorder characterized by recurrent sadness and loss of interest in the enjoyment of the positive aspects of life, in addition to fatigue, causing inability to perform daily activities, which leads to a loss of quality of life. To monitor depression (unipolar and bipolar patients), traditional methods rely on reports from patients; nevertheless, bias is commonly present in them. To overcome this problem, Ecological Momentary Assessment (EMA) reports have been widely used, which include data of the behavior, feelings and other types of activities recorded almost in real time through the use of portable devices and smartphones containing motion sensors. In this work a methodology was proposed to detect depressive subjects from control subjects based in the data of their motor activity, recorded by a wearable device, obtained from the “Depresjon” database. From the motor activity signals, the extraction of statistical features was carried out to subsequently feed a random forest classifier. Results show a sensitivity value of 0.867, referring that those subjects with presence of depression have a degree of 86.7% of being correctly classified, while the specificity shows a value of 0.919, referring that those subjects with absence of depression have a degree of 91.9% of being classified with a correct response, using the motor activity signal provided from the wearable device. Based on these results, it is concluded that the motor activity allows distinguishing between the two classes, providing a preliminary and automated tool to specialists for the diagnosis of depression.


2019 ◽  
Vol 43 (2) ◽  
Author(s):  
André Dantas de Medeiros ◽  
Manuel Jesús Zavala-León ◽  
Joyce de Oliveira Araújo ◽  
Márcio Dias Pereira ◽  
Denise Cunha Fernandes dos Santos Dias ◽  
...  

ABSTRACT The use of new methodological approaches and inclusion of non-destructive evaluations in determining the quality of forest seeds has proven to be of great importance for the development of forest production. The aim of this study was to evaluate the effectiveness of the use of a semi-automated tool for measurement of digital images obtained by the X-ray test in seed lots of Leucaena leucocephala and their relationship to seed physiological quality. Seeds were collected from five mother trees in Viçosa, MG. The study was performed through analysis of radiographic images of the seeds. It was determined the percentage of damaged seeds (predation and fungi) and measured: the area, perimeter, circularity, relative density, and integrated density of the seeds. After the X-ray test, a germination test was performed on the seeds, from which ten variables related to seed physiological quality were extracted, including a vigor index. The use of semi-automated measurement tools associated with the X-ray test was effective for evaluating the internal morphology of Leucaena leucocephala seeds, and the variables determined are related to seed physiological quality.


Author(s):  
K. T. Tokuyasu

During the past investigations of immunoferritin localization of intracellular antigens in ultrathin frozen sections, we found that the degree of negative staining required to delineate u1trastructural details was often too dense for the recognition of ferritin particles. The quality of positive staining of ultrathin frozen sections, on the other hand, has generally been far inferior to that attainable in conventional plastic embedded sections, particularly in the definition of membranes. As we discussed before, a main cause of this difficulty seemed to be the vulnerability of frozen sections to the damaging effects of air-water surface tension at the time of drying of the sections.Indeed, we found that the quality of positive staining is greatly improved when positively stained frozen sections are protected against the effects of surface tension by embedding them in thin layers of mechanically stable materials at the time of drying (unpublished).


Author(s):  
L. D. Jackel

Most production electron beam lithography systems can pattern minimum features a few tenths of a micron across. Linewidth in these systems is usually limited by the quality of the exposing beam and by electron scattering in the resist and substrate. By using a smaller spot along with exposure techniques that minimize scattering and its effects, laboratory e-beam lithography systems can now make features hundredths of a micron wide on standard substrate material. This talk will outline sane of these high- resolution e-beam lithography techniques.We first consider parameters of the exposure process that limit resolution in organic resists. For concreteness suppose that we have a “positive” resist in which exposing electrons break bonds in the resist molecules thus increasing the exposed resist's solubility in a developer. Ihe attainable resolution is obviously limited by the overall width of the exposing beam, but the spatial distribution of the beam intensity, the beam “profile” , also contributes to the resolution. Depending on the local electron dose, more or less resist bonds are broken resulting in slower or faster dissolution in the developer.


Author(s):  
G. Lehmpfuhl

Introduction In electron microscopic investigations of crystalline specimens the direct observation of the electron diffraction pattern gives additional information about the specimen. The quality of this information depends on the quality of the crystals or the crystal area contributing to the diffraction pattern. By selected area diffraction in a conventional electron microscope, specimen areas as small as 1 µ in diameter can be investigated. It is well known that crystal areas of that size which must be thin enough (in the order of 1000 Å) for electron microscopic investigations are normally somewhat distorted by bending, or they are not homogeneous. Furthermore, the crystal surface is not well defined over such a large area. These are facts which cause reduction of information in the diffraction pattern. The intensity of a diffraction spot, for example, depends on the crystal thickness. If the thickness is not uniform over the investigated area, one observes an averaged intensity, so that the intensity distribution in the diffraction pattern cannot be used for an analysis unless additional information is available.


Author(s):  
K. Shibatomi ◽  
T. Yamanoto ◽  
H. Koike

In the observation of a thick specimen by means of a transmission electron microscope, the intensity of electrons passing through the objective lens aperture is greatly reduced. So that the image is almost invisible. In addition to this fact, it have been reported that a chromatic aberration causes the deterioration of the image contrast rather than that of the resolution. The scanning electron microscope is, however, capable of electrically amplifying the signal of the decreasing intensity, and also free from a chromatic aberration so that the deterioration of the image contrast due to the aberration can be prevented. The electrical improvement of the image quality can be carried out by using the fascionating features of the SEM, that is, the amplification of a weak in-put signal forming the image and the descriminating action of the heigh level signal of the background. This paper reports some of the experimental results about the thickness dependence of the observability and quality of the image in the case of the transmission SEM.


Author(s):  
John H. Luft

With information processing devices such as radio telescopes, microscopes or hi-fi systems, the quality of the output often is limited by distortion or noise introduced at the input stage of the device. This analogy can be extended usefully to specimen preparation for the electron microscope; fixation, which initiates the processing sequence, is the single most important step and, unfortunately, is the least well understood. Although there is an abundance of fixation mixtures recommended in the light microscopy literature, osmium tetroxide and glutaraldehyde are favored for electron microscopy. These fixatives react vigorously with proteins at the molecular level. There is clear evidence for the cross-linking of proteins both by osmium tetroxide and glutaraldehyde and cross-linking may be a necessary if not sufficient condition to define fixatives as a class.


Author(s):  
Russell L. Steere ◽  
Eric F. Erbe ◽  
J. Michael Moseley

We have designed and built an electronic device which compares the resistance of a defined area of vacuum evaporated material with a variable resistor. When the two resistances are matched, the device automatically disconnects the primary side of the substrate transformer and stops further evaporation.This approach to controlled evaporation in conjunction with the modified guns and evaporation source permits reliably reproducible multiple Pt shadow films from a single Pt wrapped carbon point source. The reproducibility from consecutive C point sources is also reliable. Furthermore, the device we have developed permits us to select a predetermined resistance so that low contrast high-resolution shadows, heavy high contrast shadows, or any grade in between can be selected at will. The reproducibility and quality of results are demonstrated in Figures 1-4 which represent evaporations at various settings of the variable resistor.


Author(s):  
Alain Claverie ◽  
Zuzanna Liliental-Weber

GaAs layers grown by MBE at low temperatures (in the 200°C range, LT-GaAs) have been reported to have very interesting electronic and transport properties. Previous studies have shown that, before annealing, the crystalline quality of the layers is related to the growth temperature. Lowering the temperature or increasing the layer thickness generally results in some columnar polycrystalline growth. For the best “temperature-thickness” combinations, the layers may be very As rich (up to 1.25%) resulting in an up to 0.15% increase of the lattice parameter, consistent with the excess As. Only after annealing are the technologically important semi-insulating properties of these layers observed. When annealed in As atmosphere at about 600°C a decrease of the lattice parameter to the substrate value is observed. TEM studies show formation of precipitates which are supposed to be As related since the average As concentration remains almost unchanged upon annealing.


Sign in / Sign up

Export Citation Format

Share Document