NEW TECHNIQUES OF EXTENDED ELECTRON SPECTROSCOPY AND RELATED SPECTROSCOPIES

Author(s):  
Shigero Ikeda
1962 ◽  
Vol 11 (02) ◽  
pp. 137-143
Author(s):  
M. Schwarzschild

It is perhaps one of the most important characteristics of the past decade in astronomy that the evolution of some major classes of astronomical objects has become accessible to detailed research. The theory of the evolution of individual stars has developed into a substantial body of quantitative investigations. The evolution of galaxies, particularly of our own, has clearly become a subject for serious research. Even the history of the solar system, this close-by intriguing puzzle, may soon make the transition from being a subject of speculation to being a subject of detailed study in view of the fast flow of new data obtained with new techniques, including space-craft.


Author(s):  
Dennis Maher ◽  
David Joy ◽  
Peggy Mochel

A variety of standard specimens is needed in order to systematically investigate the instrumentation, specimen, data reduction and quantitation variables in electron energy-loss spectroscopy (EELS). Pure single element specimens (e.g. various forms of carbon) have received considerable attention to date but certain elements of interest cannot be prepared directly as thin films. Since studies of the first and second row elements in two- or multicomponent systems will be of considerable importance in microanalysis using EELS, there is a need for convenient standards containing these species. For many investigations a standard should contain the desired element, or elements, homogeneously dispersed through a suitable matrix and at an accurately known concentration. These conditions may be met by the technique of implantation.Silicon was chosen as the host lattice since its principal ionization energies, EL23 = 98 eV and Ek = 1843 eV, are well removed from the K-edges of most elements of major interest such as boron (Ek = 188 eV), carbon (Ek = 283 eV), nitrogen (Ek = 400 eV) and oxygen (Ek = 532 eV).


Author(s):  
M.A. Parker ◽  
K.E. Johnson ◽  
C. Hwang ◽  
A. Bermea

We have reported the dependence of the magnetic and recording properties of CoPtCr recording media on the thickness of the Cr underlayer. It was inferred from XRD data that grain-to-grain epitaxy of the Cr with the CoPtCr was responsible for the interaction observed between these layers. However, no cross-sectional TEM (XTEM) work was performed to confirm this inference. In this paper, we report the application of new techniques for preparing XTEM specimens from actual magnetic recording disks, and for layer-by-layer micro-diffraction with an electron probe elongated parallel to the surface of the deposited structure which elucidate the effect of the crystallographic structure of the Cr on that of the CoPtCr.XTEM specimens were prepared from magnetic recording disks by modifying a technique used to prepare semiconductor specimens. After 3mm disks were prepared per the standard XTEM procedure, these disks were then lapped using a tripod polishing device. A grid with a single 1mmx2mm hole was then glued with M-bond 610 to the polished side of the disk.


Author(s):  
A. Howie ◽  
D.W. McComb

The bulk loss function Im(-l/ε (ω)), a well established tool for the interpretation of valence loss spectra, is being progressively adapted to the wide variety of inhomogeneous samples of interest to the electron microscopist. Proportionality between n, the local valence electron density, and ε-1 (Sellmeyer's equation) has sometimes been assumed but may not be valid even in homogeneous samples. Figs. 1 and 2 show the experimentally measured bulk loss functions for three pure silicates of different specific gravity ρ - quartz (ρ = 2.66), coesite (ρ = 2.93) and a zeolite (ρ = 1.79). Clearly, despite the substantial differences in density, the shift of the prominent loss peak is very small and far less than that predicted by scaling e for quartz with Sellmeyer's equation or even the somewhat smaller shift given by the Clausius-Mossotti (CM) relation which assumes proportionality between n (or ρ in this case) and (ε - 1)/(ε + 2). Both theories overestimate the rise in the peak height for coesite and underestimate the increase at high energies.


Author(s):  
C.L. Briant

Grain boundary segregation is the process by which solute elements in a material diffuse to the grain boundaries, become trapped there, and increase their local concentration at the boundary over that in the bulk. As a result of this process this local concentration of the segregant at the grain boundary can be many orders of magnitude greater than the bulk concentration of the segregant. The importance of this problem lies in the fact that grain boundary segregation can affect many material properties such as fracture, corrosion, and grain growth.One of the best ways to study grain boundary segregation is with Auger electron spectroscopy. This spectroscopy is an extremely surface sensitive technique. When it is used to study grain boundary segregation the sample must first be fractured intergranularly in the high vacuum spectrometer. This fracture surface is then the one that is analyzed. The development of scanning Auger spectrometers have allowed researchers to first image the fracture surface that is created and then to perform analyses on individual grain boundaries.


Author(s):  
P. Pradère ◽  
J.F. Revol ◽  
R. St. John Manley

Although radiation damage is the limiting factor in HREM of polymers, new techniques based on low dose imaging at low magnification have permitted lattice images to be obtained from very radiation sensitive polymers such as polyethylene (PE). This paper describes the computer averaging of P4MP1 lattice images. P4MP1 is even more sensitive than PE (total end point dose of 27 C m-2 as compared to 100 C m-2 for PE at 120 kV). It does, however, have the advantage of forming flat crystals from dilute solution and no change in d-spacings is observed during irradiation.Crystals of P4MP1 were grown at 60°C in xylene (polymer concentration 0.05%). Electron microscopy was performed with a Philips EM 400 T microscope equipped with a Low Dose Unit and operated at 120 kV. Imaging conditions were the same as already described elsewhere. Enlarged micrographs were digitized and processed with the Spider image processing system.


Author(s):  
Huang Min ◽  
P.S. Flora ◽  
C.J. Harland ◽  
J.A. Venables

A cylindrical mirror analyser (CMA) has been built with a parallel recording detection system. It is being used for angular resolved electron spectroscopy (ARES) within a SEM. The CMA has been optimised for imaging applications; the inner cylinder contains a magnetically focused and scanned, 30kV, SEM electron-optical column. The CMA has a large inner radius (50.8mm) and a large collection solid angle (Ω > 1sterad). An energy resolution (ΔE/E) of 1-2% has been achieved. The design and performance of the combination SEM/CMA instrument has been described previously and the CMA and detector system has been used for low voltage electron spectroscopy. Here we discuss the use of the CMA for ARES and present some preliminary results.The CMA has been designed for an axis-to-ring focus and uses an annular type detector. This detector consists of a channel-plate/YAG/mirror assembly which is optically coupled to either a photomultiplier for spectroscopy or a TV camera for parallel detection.


Author(s):  
S. H. Chen

Sn has been used extensively as an n-type dopant in GaAs grown by molecular-beam epitaxy (MBE). The surface accumulation of Sn during the growth of Sn-doped GaAs has been observed by several investigators. It is still not clear whether the accumulation of Sn is a kinetically hindered process, as proposed first by Wood and Joyce, or surface segregation due to thermodynamic factors. The proposed donor-incorporation mechanisms were based on experimental results from such techniques as secondary ion mass spectrometry, Auger electron spectroscopy, and C-V measurements. In the present study, electron microscopy was used in combination with cross-section specimen preparation. The information on the morphology and microstructure of the surface accumulation can be obtained in a fine scale and may confirm several suggestions from indirect experimental evidence in the previous studies.


Author(s):  
Antonia M. Milroy

In recent years many new techniques and instruments for 3-Dimensional visualization of electron microscopic images have become available. Higher accelerating voltage through thicker sections, photographed at a tilt for stereo viewing, or the use of confocal microscopy, help to analyze biological material without the necessity of serial sectioning. However, when determining the presence of neurotransmitter receptors or biochemical substances present within the nervous system, the need for good serial sectioning (Fig. 1+2) remains. The advent of computer assisted reconstruction and the possibility of feeding information from the specimen viewing chamber directly into a computer via a camera mounted on the electron microscope column, facilitates serial analysis. Detailed information observed at the subcellular level is more precise and extensive and the complexities of interactions within the nervous system can be further elucidated.We emphasize that serial ultra thin sectioning can be performed routinely and consistently in multiple user electron microscopy laboratories. Initial tissue fixation and embedding must be of high quality.


2000 ◽  
Vol 10 (2) ◽  
pp. 4-5
Author(s):  
Robin A. Samlan ◽  
Paul W. Flint ◽  
Celia Bassich-Zeren
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document