scholarly journals Is the boundary layer of an ionic liquid equally lubricating at higher temperature?

2016 ◽  
Vol 18 (13) ◽  
pp. 9232-9239 ◽  
Author(s):  
Nicklas Hjalmarsson ◽  
Rob Atkin ◽  
Mark W. Rutland

Atomic force microscopy has been used to study the effect of temperature on normal forces and friction for the room temperature ionic liquid (IL) ethylammonium nitrate (EAN), confined between mica and a silica colloid probe at 25 °C, 50 °C, and 80 °C.

2018 ◽  
Vol 2 (4) ◽  
pp. 60 ◽  
Author(s):  
Milad Radiom ◽  
Patricia Pedraz ◽  
Georgia Pilkington ◽  
Patrick Rohlmann ◽  
Sergei Glavatskih ◽  
...  

We investigate the interfacial properties of the non-halogenated ionic liquid (IL), trihexyl(tetradecyl)phosphonium bis(mandelato)borate, [P6,6,6,14][BMB], in proximity to solid surfaces, by means of surface force measurement. The system consists of sharp atomic force microscopy (AFM) tips interacting with solid surfaces of mica, silica, and gold. We find that the force response has a monotonic form, from which a characteristic steric decay length can be extracted. The decay length is comparable with the size of the ions, suggesting that a layer is formed on the surface, but that it is diffuse. The long alkyl chains of the cation, the large size of the anion, as well as crowding of the cations at the surface of negatively charged mica, are all factors which are likely to oppose the interfacial stratification which has, hitherto, been considered a characteristic of ionic liquids. The variation in the decay length also reveals differences in the layer composition at different surfaces, which can be related to their surface charge. This, in turn, allows the conclusion that silica has a low surface charge in this aprotic ionic liquid. Furthermore, the effect of temperature has been investigated. Elevating the temperature to 40 °C causes negligible changes in the interaction. At 80 °C and 120 °C, we observe a layering artefact which precludes further analysis, and we present the underlying instrumental origin of this rather universal artefact.


2005 ◽  
Vol 492-493 ◽  
pp. 335-340 ◽  
Author(s):  
F. Giuliani ◽  
A. Goruppa ◽  
S.J. Lloyd ◽  
Dennis Teer ◽  
W.J. Clegg

Observations elsewhere have shown that multilayer structures with layers ~10 nm thick can be harder than monolithic ones. Here we see whether these effects can be observed at high temperatures and investigate the effect of temperature on the manner of deformation. The hardness of an AlN/CrN multilayer structure with a range of wavelengths from 6-200 nm has been measured at temperatures from room temperature to 400 oC. The changes in hardness have been related to the deformation behaviour observed by cross-sectional transmission electron microscopy and atomic force microscopy. These observations suggest that the mechanical properties of the coatings are dominated by the refinement in the columnar microstructure rather than directly by an effect of the layer interfaces on dislocation motion.


Author(s):  
K. A. Fisher ◽  
M. G. L. Gustafsson ◽  
M. B. Shattuck ◽  
J. Clarke

The atomic force microscope (AFM) is capable of imaging electrically conductive and non-conductive surfaces at atomic resolution. When used to image biological samples, however, lateral resolution is often limited to nanometer levels, due primarily to AFM tip/sample interactions. Several approaches to immobilize and stabilize soft or flexible molecules for AFM have been examined, notably, tethering coating, and freezing. Although each approach has its advantages and disadvantages, rapid freezing techniques have the special advantage of avoiding chemical perturbation, and minimizing physical disruption of the sample. Scanning with an AFM at cryogenic temperatures has the potential to image frozen biomolecules at high resolution. We have constructed a force microscope capable of operating immersed in liquid n-pentane and have tested its performance at room temperature with carbon and metal-coated samples, and at 143° K with uncoated ferritin and purple membrane (PM).


2020 ◽  
Vol 22 (48) ◽  
pp. 28191-28201
Author(s):  
Georgia A. Pilkington ◽  
Rebecca Welbourn ◽  
Anna Oleshkevych ◽  
Seiya Watanabe ◽  
Patricia Pedraz ◽  
...  

The influence of ambient levels of water on the electroresponsive interfacial structuring and nanofriction of ionic liquid lubricant mixtures has been investigated by neutron reflectivity and atomic force microscopy.


2010 ◽  
Vol 663-665 ◽  
pp. 324-327
Author(s):  
Chao Song ◽  
Rui Huang

The germanium film and Ge/Si multilayer structure were fabricated by magnetron sputtering technique on silicon substrate at temperatures of 500°C. Raman scattering spectroscopy measurements reveal that the nanocrystalline Ge occurs in both kinds of samples. Furthermore, from the atomic force microscopy (AFM) results, it is found that the grain size as well as spatially ordering distribution of the nc-Ge can be modulated by the Ge/Si multilayer structure. The room temperature photoluminescence was also observed in the samples. However, compared with that from the nc-Ge film, the intensity of PL from the nc-Ge/a-Si multilayer film becomes weaker, which is attributed to its lower volume fraction of crystallized component.


Author(s):  
Lin Zhang ◽  
Bai An ◽  
Takashi Iijima ◽  
Chris San Marchi ◽  
Brian Somerday

The behaviors of hydrogen transport and hydrogen-assisted cracking in hydrogen-precharged SUS304 austenitic stainless steel sheets in a temperature range from 177 to 298 K are investigated by a combined tensile and hydrogen release experiment as well as magnetic force microscopy (MFM) based on atomic force microscopy (AFM). It is observed that the hydrogen embrittlement increases with decreasing temperature, reaches a maximum at around 218 K, and then decreases with further temperature decrease. The hydrogen release rate increases with increasing strain until fracture at room temperature but remains near zero level at and below 218 K except for some small distinct release peaks. The MFM observations reveal that fracture occurs at phase boundaries along slip planes at room temperature and twin boundaries at 218 K. The role of strain-induced martensite in the hydrogen transport and hydrogen embrittlement is discussed.


2006 ◽  
Vol 20 (02) ◽  
pp. 217-231 ◽  
Author(s):  
MUHAMMAD MAQBOOL ◽  
TAHIRZEB KHAN

Thin films of pure silver were deposited on glass substrate by thermal evaporation process at room temperature. Surface characterization of the films was performed using X-ray diffraction (XRD) and atomic force microscopy (AFM). Thickness of the films varied between 20 nm and 72.8 nm. XRD analysis provided a sharp peak at 38.75° from silver. These results indicated that the films deposited on glass substrates at room temperature are crystalline. Three-dimension and top view pictures of the films were obtained by AFM to study the grain size and its dependency on various factors. Average grain size increased with the thickness of the deposited films. A minimum grain size of 8 nm was obtained for 20 nm thick films, reaching 41.9 nm when the film size reaches 60 nm. Grain size was calculated from the information provided by the XRD spectrum and averaging method. We could not find any sequential variation in the grain size with the growth rate.


Sign in / Sign up

Export Citation Format

Share Document