The physico-mechanical properties of concrete with red-mud at high temperatures

2020 ◽  
Vol 11 (4) ◽  
pp. 82
Author(s):  
Ibrahim A. Alameri ◽  
Meral Oltulu

Reuse of treated waste can provide significant environmental, social and economic benefits. It is necessary to use it in the right places while keeping the properties of the waste in mind. Aluminum-rich wastes such as red mud derived from bauxite may be used in places exposed to high temperatures. This article discusses the effects of high temperatures of 25, 200, 300, 400, 600 and 800°C and 3 hours of exposure on concrete samples replaced by red mud at 0, 10, 15 and 20%. To study the concrete’s mechanical and permeability properties, loss in weight, compressive strength, splitting tensile strength, capillary water absorption and water permeability tests were performed for all mixes. Results were closer to those of the control specimen, which ultimately supported the use of red mud at a ratio of 10%.

Recycling of materials has become a major interest for engineers. At present, the amount of slag deposited in storage yard adds up to millions of tons/year leading to the occupation of farm land and serious pollution to the environment, as a result of the rapid growth in the steel industry. Steel slag is made at 1500- 1650°C having a honey comp shape with high porosity. Using steel slag as the natural aggregate with a lower waste material cost can be considered as a good alternative for sustainable constructions. The objective of this study is to evaluate the performance of residual mechanical properties of concrete with steel slag as coarse aggregate partial replacement after exposing to high temperatures .This study investigates the behavior of using granulated slag as partial or fully coarse aggregate replacement with different percentages of 0%, 15%, 30%, 50% and 100% in concrete when subjected to elevated temperatures. Six groups of concrete mixes were prepared using various replacement percentages of slag exposed to different temperatures of 400 °C, 600 °C and 800 °C for different durations of 1hr, 1.5hr and 2hr. Evaluation tests were compressive strength, tensile strength, and bond strength. The steel slag concrete mixes showed week workability lower than control mix. A systematic increasing of almost up to 21.7% in compressive strength, and 66.2% in tensile strength with increasing the percentage of steel slag replacement to 50%. And the results showed improvement on concrete residual mechanical properties after subjected to elevated temperatures with the increase of steel slag content. The findings of this study give an overview of the effect of steel slag coarse aggregate replacement on concrete after exposed to high temperatures.


2016 ◽  
Vol 23 (2) ◽  
pp. 209-216 ◽  
Author(s):  
Hakan Bolat ◽  
Pınar Erkus

AbstractConcrete is one of the materials in which polymer wastes are utilized. Generally, these wastes are added at specific rates in scientific studies but an important problem of waste polymers is size irregularity. Even when consistent dosage rates are used, variations in polymer size can lead to variability in the physical and mechanical properties of the concrete produced. The aim of this study is to determine physical and mechanical properties of polyvinyl chloride (PVC)-containing concretes. In order to produce normal and high strength concretes, 10%, 20%, and 30% replacement ratios of PVC powder and granules by volume of aggregate are used. Slump, fresh and hardened densities, compressive strength, capillary water absorption, and abrasion were tested on all concrete types. As the PVC ratio increases, important changes are seen in all physical and mechanical concrete properties. The unit weights of the 10%, 20%, and 30% replacement PVC powder concretes are lower by ∼4%, 8%, and 13%, respectively, as compared to the reference mixtures, and the replacement PVC granule concretes are lower by ∼2%, 4%, and 7%. Compressive strength test results showed similar trends. As PVC replacement increases, the capillary water absorption decreases between 10% and 50%, and abrasion decreases between 27% and 77%.


2011 ◽  
Vol 147 ◽  
pp. 37-41 ◽  
Author(s):  
Ezahtul Shahreen Ab Wahab ◽  
Siti Fatimah Che Osmi

This investigation was carried out to look the possibility of using chicken rachis as reinforcement in concrete mix. In this study, two different percentage of rachis from chicken feather were added to plain concrete comprises of 1% and 2% from the total weight of cement. Concrete with grade 30 were formed by using chicken rachis as additive material. Selected mechanical test were performed and the results were analysed. The mechanical tests included compressive strength, and splitting tensile strength. Comparison was made of these values and those of control specimen (without chicken rachis). The results showed an increment on strength for all mechanical tests done using concrete added with 1% chicken rachis compared to 2% chicken rachis added and those control specimens.


2021 ◽  
Vol 1203 (3) ◽  
pp. 032097
Author(s):  
Marija Vaiciene ◽  
Jurgita Malaiskiene

Abstract In this work is analysing the impact of wood waste bottom ash (WWBA) on the physical mechanical properties of Portland cement concrete (PCC). WWBA is a waste generated in power plants during burning forest residues to produce energy and heat. In 2019, about 19,800 tons of WWBA was generated only in Lithuania. Usually, WWBA is disposed of in landfills, only 26% of WWBA is used in the construction or maintenance of local roads, because of that it is useful to know properties of such WWBA and to analyse possibilities of using it in cement concrete. In the chemical composition of such WWBA type was fixed a big amount ~50% of CO2. It is known, that C retards cement hydration. Due to stabilisation this process, it was used in the same amounts catalyst waste from oil cracking (FCCCw), which could accelerate hydration processes. Oil refineries worldwide generate more than 800,000 tonnes of FCCCw per year, of which around 20% in Europe and it is the big problem to landfill. In the investigation the amount of Portland cement (5-20% by mass) was replaced by mentioned wastes and properties of fresh PCC (density, slump, flow diameter) and physical mechanical properties of hardened PCC (water absorption, capillary water absorption, ultrasound pulse velocity, density, compressive strength after 28 days and 2 years curing, SEM) were established. It was determined, that by increasing amount of waste (till 20%) the workability of concrete decreases, because used wastes had higher water requirement. The best results were obtained, when 5% of cement was replaced by WWBA. Then compressive strength after 28 days curing comparing to control sample decreased 8%, but after 2 years curing it increased 1%, also the capillary water absorption decreased, denser structure was formed. The obtained results of hardened PCC density, ultrasound pulse velocity and water absorption are similar to control samples.


2020 ◽  
Vol 14 (2) ◽  
pp. 6734-6742
Author(s):  
A. Syamsir ◽  
S. M. Mubin ◽  
N. M. Nor ◽  
V. Anggraini ◽  
S. Nagappan ◽  
...  

This study investigated the combine effect of 0.2 % drink cans and steel fibers with volume fractions of 0%, 0.5%, 1%, 1.5%, 2%, 2.5% and 3% to the mechanical properties and impact resistance of concrete. Hooked-end steel fiber with 30 mm and 0.75 mm length and diameter, respectively was selected for this study.  The drinks cans fiber were twisted manually in order to increase friction between fiber and concrete. The results of the experiment showed that the combination of steel fibers and drink cans fibers improved the strength performance of concrete, especially the compressive strength, flexural strength and indirect tensile strength. The results of the experiment showed that the combination of steel fibers and drink cans fibers improved the compressive strength, flexural strength and indirect tensile strength by 2.3, 7, and 2 times as compare to batch 1, respectively. Moreover, the impact resistance of fiber reinforced concrete has increase by 7 times as compared to non-fiber concretes. Moreover, the impact resistance of fiber reinforced concrete consistently gave better results as compared to non-fiber concretes. The fiber reinforced concrete turned more ductile as the dosage of fibers was increased and ductility started to decrease slightly after optimum fiber dosage was reached. It was found that concrete with combination of 2% steel and 0.2% drink cans fibers showed the highest compressive, split tensile, flexural as well as impact strength.    


2021 ◽  
Vol 28 (1) ◽  
pp. 343-351
Author(s):  
Norbert Kępczak ◽  
Radosław Rosik ◽  
Mariusz Urbaniak

Abstract The paper presents an impact of the addition of industrial machining chips on the mechanical properties of polymer concrete. As an additional filler, six types of industrial waste machining chips were used: steel fine chips, steel medium chips, steel thick chips, aluminium fine chips, aluminium medium chips, and titanium fine chips. During the research, the influence of the addition of chips on the basic parameters of mechanical properties, i.e., tensile strength, compressive strength, splitting tensile strength, and Young’s modulus, was analyzed. On the basis of the obtained results, conclusions were drawn that the addition of chips from machining causes a decrease in the value of the mechanical properties parameters of the polymer concrete even by 30%. The mechanism of cracking of samples, which were subjected to durability tests, was also explored. In addition, it was found that some chip waste can be used as a substitute for natural fillers during preparation of a mineral cast composition without losing much of the strength parameters.


2014 ◽  
Vol 887-888 ◽  
pp. 824-829
Author(s):  
Qing Fang Lv ◽  
Ji Hong Qin ◽  
Ran Zhu

Laminated veneer lumber is taken as an object of study, and use LVL specimens of different sizes for compression test and tensile test. The goal of the experiment is to investigate the size effect on compressive strength and tensile strength as well as the influence of the secondary glued laminated face, which appears in the secondary molding processes. The results show that both compressive strength and tensile strength have the size effect apparently and the existence of the secondary glued laminated face lower the compressive strength of LVL specimens. Afterwards, the relationship between compressive strength and volume along with tensile strength and area are obtained by the test results.


2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Wasim Barham ◽  
Ammar AL-Maabreh ◽  
Omar Latayfeh

PurposeThe influence of using magnetic water instead of tap water in the mechanical properties of the concrete exposed to elevated temperatures was investigated. Two concrete mixes were used and cast with the same ingredients. Tap water was used in the first mix and magnetic water was used in the second mix. A total of 48 specimens were cast and divided as follows: 16 cylinders for the concrete compressive strength test (8 samples for each mix), 16 cylinders for the splitting tensile strength (8 specimens for each mix) and 16 beams to test the influences of magnetized water on the flexural strength of concrete (8 specimens for each mixture). Specimens were exposed to temperatures of (25 °C, 200 °C, 400 °C and 600 °C). The experimental results showed that magnetic water highly affected the mechanical properties of concrete. Specimens cast and curried out with magnetic water show higher compressive strength, splitting tensile strength and flexural strength compared to normal water specimens at all temperatures. The relative strength range between the two types of water used was 110–123% for compressive strength and 110–133% for splitting strength. For the center point loading test, the relative flexural strength range was 118–140%. The use of magnetic water in mixing concrete contribute to a more complete hydration process.Design/methodology/approachExperimental study was carried out on two concrete mixes to investigate the effect of magnetic water. Mix#1 used normal water as the mixing water, and Mix#2 used magnetic water instead of normal water. After 28 days, all the samples were taken out of the tank and left to dry for seven days, then they were divided into different groups. Each group was exposed to a different temperature where it was placed in a large oven for two hours. Three different tests were carried out on the samples, these tests were concrete compressive strength, flexural strength and splitting tensile strength.FindingsExposure of concrete to high temperatures had a significant influence on concrete mechanical properties. Specimens prepared using magnetic water showed higher compressive strength at all temperature levels. The use of magnetic water in casting and curing concrete can increase the compressive strength by 23%. Specimens prepared using magnetic water show higher splitting tensile strength at all temperatures up to 33%. The use of magnetic water in casting and curing can strengthen and increase concrete resistance to high temperatures, a significant enhancement in flexural strength at all temperatures was found with a value up to 40%.Originality/valuePrevious research proved the advantages of using magnetic water for improving the mechanical properties of concrete under normal conditions. The potential of using magnetic water in the concrete industry in the future requires conducting extensive research to study the behavior of magnetized concrete under severe conditions to which concrete structures may be subjected to. These days, there are attempts to obtain stronger concrete with high resistance to harsh environmental conditions without adding new costly ingredients to its main mixture. No research has been carried out to investigate the effect of magnetic water on the mechanical properties of concrete exposed to elevated temperature. The main objective of this study is to evaluate the effect of using magnetic water on the mechanical properties of hardened concrete subjected to elevated temperature.


2015 ◽  
Vol 773-774 ◽  
pp. 949-953 ◽  
Author(s):  
Izni Syahrizal Ibrahim ◽  
Wan Amizah Wan Jusoh ◽  
Abdul Rahman Mohd Sam ◽  
Nur Ain Mustapa ◽  
Sk Muiz Sk Abdul Razak

This paper discusses the experimental results on the mechanical properties of hybrid fibre reinforced composite concrete (HyFRCC) containing different proportions of steel fibre (SF) and polypropylene fibre (PPF). The mechanical properties include compressive strength, tensile strength, and flexural strength. SF is known to enhance the flexural and tensile strengths, and at the same time is able to resist the formation of macro cracking. Meanwhile, PPF contributes to the tensile strain capacity and compressive strength, and also delay the formation of micro cracks. Hooked-end deformed type SF fibre with 60 mm length and fibrillated virgin type PPF fibre with 19 mm length are used in this study. Meanwhile, the concrete strength is maintained for grade C30. The percentage proportion of SF-PPF fibres are varied in the range of 100-0%, 75-25%, 50-50%, 25-75% and 0-100% of which the total fibre volume fraction (Vf) is fixed at 0.5%. The experimental results reveal that the percentage proportion of SF-PPF fibres with 75-25% produced the maximum performance of flexural strength, tensile strength and flexural toughness. Meanwhile, the percentage proportion of SF-PPF fibres with 100-0% contributes to the improvement of the compressive strength compared to that of plain concrete.


2008 ◽  
Vol 1 (2) ◽  
pp. 113-120 ◽  
Author(s):  
A. C. Marques ◽  
J. L. Akasaki ◽  
A. P. M. Trigo ◽  
M. L. Marques

In this work it was evaluated the influence tire rubber addition in mortars in order to replace part of the sand (12% by volume). It was also intended to verify if the tire rubber treatment with NaOH saturated aqueous solution causes interference on the mechanical properties of the mixture. Compressive strength, splitting tensile strength, water absorption, modulus of elasticity, and flow test were made in specimens of 5cmx10cm and the tests were carried out to 7, 28, 56, 90, and 180 days. The results show reduction on mechanical properties values after addition of tire rubber and decrease of the workability. It was also observed that the tire rubber treatment does not cause any alteration on the results compared to the rubber without treatment.


Sign in / Sign up