Removal of micropollutants from municipal wastewater by graphene adsorption and simultaneous electrocoagulation/electrofiltration process

2017 ◽  
Vol 75 (8) ◽  
pp. 1882-1888 ◽  
Author(s):  
Gordon C. C. Yang ◽  
Pei-Ling Tang ◽  
Chia-Heng Yen

In this work the optimal operating conditions for removing selected micropollutants (also known as emerging contaminants, ECs) from actual municipal wastewater by graphene adsorption (GA) and simultaneous electrocoagulation/electrofiltration (EC/EF) process, respectively, were first determined and evaluated. Then, performance and mechanisms for the removal of selected phthalates and pharmaceuticals from municipal wastewater simultaneously by the GA and EC/EF process were further assessed. ECs of concern included di-n-butyl phthalate (DnBP), di-(2-ethylhexyl) phthalate (DEHP), acetaminophen (ACE), caffeine (CAF), cefalexin (CLX) and sulfamethoxazole (SMX). It was found that GA plus EC/EF process yielded the following removal efficiencies: DnBP, 89 ± 2%; DEHP, 85 ± 3%; ACE, 99 ± 2%; CAF, 94 ± 3%; CLX, 100 ± 0%; and SMX, 98 ± 2%. Carbon adsorption, size exclusion, electrostatic repulsion, electrocoagulation, and electrofiltration were considered as the main mechanisms for the removal of target ECs by the integrated process indicated above.

2016 ◽  
Vol 73 (9) ◽  
pp. 2268-2274 ◽  
Author(s):  
Gordon C. C. Yang ◽  
Pei-Ling Tang

In this work graphene was used for evaluation of its adsorption behavior and performance in removing phthalate esters and pharmaceuticals in municipal wastewater. Di-n-butyl phthalate (DnBP), di-(2-ethylhexyl) phthalate (DEHP), acetaminophen (ACE), caffeine (CAF), cephalexin (CLX), and sulfamethoxazole (SMX) were emerging contaminants (ECs) with detection frequencies over 92% in a one-year monitoring of the occurrence of ECs in influent samples of a sewage treatment plant in Taiwan. Thus, these ECs were selected as the target contaminants for removal by graphene adsorption process. Experimental results showed that the adsorption isotherm data were fitted well to Langmuir model equation. It was also found that the adsorption process obeyed the pseudo-second-order kinetics. A graphene dosage of 0.1 g/L and adsorption time of 12 h were found to be the optimal operating conditions for the ECs of concern in model solutions in a preliminary study. By using the determined optimal operating conditions for removal of such ECs in actual municipal wastewater, removal efficiencies for various ECs were obtained and given as follows: (1) DnBP, 89%, (2) DEHP, 86%, (3) ACE, 43%, (4) CAF, 84%, (5) CLX, 81%, and (6) SMX, 34%.


2012 ◽  
Vol 599 ◽  
pp. 387-390
Author(s):  
Xing Yu Bian ◽  
Xing Sheng Kang ◽  
Yi Li ◽  
Yu Lin Sun ◽  
Min Kong ◽  
...  

In this paper, chemical and biological flocculation and suspended medium process was applied to treat low concentration municipal wastewater in a pilot scale test in order to find the optimum operational parameter. The results showed that: system on pollutant removal mainly on chemical and biological flocculation reaction pool, Under the optimal operating condition, CODCr, TP and SS removal efficiencies reached 75.5%, 76%and 90.5% respectively, and the CODCr, TP, SS concentrations of effluent meet the National Wastewater Integrated Discharge Standard. The optimum operating conditions according to the local actual situation, running for more than half a year, for the optimization of control parameters for the contrast obtained.


2011 ◽  
Vol 347-353 ◽  
pp. 440-443 ◽  
Author(s):  
Yan Shi ◽  
Hai Chen Yu ◽  
Dan Yu Xu ◽  
Xian Qiang Zheng

Three-dimensional-electrode electro-Fenton is a newly electrochemical oxidation technology to treat landfill leachate. In contrast, the removal efficiencies of COD and color in DSA system are obviously higher than those in iron anode system and the organics can be degraded more thoroughly. Under the optimal operating conditions, the removal efficiencies of COD, NH3-N and color in landfill leachate by DSA system are up to 80.8% ,55.2% and 98.6%. Besides, the reaction mechanism of three-dimensional-electrode electro-Fenton is also discussed.


1982 ◽  
Vol 14 (1-2) ◽  
pp. 121-133
Author(s):  
C Forsberg ◽  
B Hawerman ◽  
B Hultman

Experience from advanced municipal wastewater treatment plants and recovery of polluted waters are described for the last ten years in Sweden. Except in municipalities with large recipients, the urban population is served by treatment plants with combined biological and chemical treatment. Most of these plants are post-precipitation plants. Several modified operational modes have been developed in order to improve the removal efficiencies of pollutants and to reduce the costs. Results are presented on the recovery of specially investigated lakes with a lowered supply of total phosphorus and organic matter.


1987 ◽  
Vol 19 (3-4) ◽  
pp. 449-460 ◽  
Author(s):  
W. Giger ◽  
M. Ahel ◽  
M. Koch ◽  
H. U. Laubscher ◽  
C. Schaffner ◽  
...  

Effluents and sludges from several municipal sewage treatment plants in Switzerland were analyzed for nonylphenol polyethoxylates (NPnEO, n=3-20), nonylphenol mono- and diethoxylate (NPlEO, NP2EO), corresponding nonylphenoxy carboxylic acids (NP1EC, NP2EC) and nonylphenol (NP). These chemicals derive from nonionic surfactants of the NPnEO-type, and specific analitical techniques were used to study their behaviour during mechanical-biological sewage and subsequent sludge treatment. The parent NPnEO-surfactants, with concentrations in raw and mechanically treated sewage from 400-2200 mg/m3, were relatively efficiently removed by the activated sludge treatment. The abundances of the different metabolites varied depending on treatment conditions. The refractory nature of NPl/2EO, NP and NPl/2EC was recognized. Both biotransformations and physico-chemical processes determine the behaviour and fate of nonylphenolic substances in sewage treatment. Nitrilotriacetate (NTA) was found in primary effluents at concentrations between 430 and 1390 mg/m3. The various treatment plants showed different removal efficiencies for NTA depending on the operating conditions. Activated sludge treatment with low sludge loading rates and nitrifying conditions removed NTA with efficiencies between 95 and 99%. High sludge loading caused a decrease in NTA removal efficiencies from 70% to 39%.


1994 ◽  
Vol 30 (6) ◽  
pp. 237-246 ◽  
Author(s):  
A. Carucci ◽  
M. Majone ◽  
R. Ramadori ◽  
S. Rossetti

This paper describes a lab-scale experimentation carried out to study enhanced biological phosphate removal (EBPR) in a sequencing batch reactor (SBR). The synthetic feed used was based on peptone and glucose as organic substrate to simulate the readily biodegradable fraction of a municipal wastewater (Wentzel et al., 1991). The experimental work was divided into two runs, each characterized by different operating conditions. The phosphorus removal efficiency was considerably higher in the absence of competition for organic substrate between P-accumulating and denitrifying bacteria. The activated sludge consisted mainly of peculiar microorganisms recently described by Cech and Hartman (1990) and called “G bacteria”. The results obtained seem to be inconsistent with the general assumption that the G bacteria are characterized by anaerobic substrate uptake not connected with any polyphosphate metabolism. Supplementary anaerobic batch tests utilizing glucose, peptone and acetate as organic substrates show that the role of acetate in the biochemical mechanisms promoting EBPR may not be so essential as it has been assumed till now.


1996 ◽  
Vol 34 (5-6) ◽  
pp. 249-256 ◽  
Author(s):  
Hong-Ying Hu ◽  
Mamie Nozawa ◽  
Koichi Fujie ◽  
Tsuyoshi Makabe ◽  
Kohei Urano

The population dynamics of microbes in the biological wastewater treatment processes such as a submerged biofilter was investigated to obtain basic information to determine the optimal operating conditions. The effects of coexistence of biodegradable substances such as glucose and peptone on the acclimation of microbes in the biofilm to hard chemicals such as acrylonitrile (AN), which is poorly biodegradable and a volatile substance, was investigated on the basis of the respiratory quinone profile. Kinetic study of the removal of AN in the course of acclimation of microbes was investigated using a laboratory-scale submerged biofilter as well. It was ascertained that the acclimation of the microbes to AN was accelerated by coexistence of biodegradable substances, and the microbial phase after acclimation differed from those with the coexistence of glucose and peptone. The quinone profiles in the acclimation showed that Brevibacterium sp. and Pseudomonas aeruginosa, of which the predominant quinone of the respiratory chain is menaquinone-8(H2) and ubiquinone-9, respectively, multiplied selectively in the acclimation course without and with the coexistence of glucose and peptone, respectively. It was also made clear that there were few kinds and number of protozoa and metazoa in the biofilter treating the wastewater containing AN.


Energies ◽  
2021 ◽  
Vol 14 (3) ◽  
pp. 555
Author(s):  
Sangkyung Na ◽  
Sanghun Song ◽  
Seunghyuk Lee ◽  
Jehwan Lee ◽  
Hyun Kim ◽  
...  

In this study, evaporator optimization, via both experimental and simulation methods was conducted. To evaluate the evaporator performance, under the optimal system, the compressor operating time and the effects of oil on the refrigerator system were studied. If the temperature of the refrigerator chamber reaches the setting value, the compressor stops working and it leads to the temperature of the refrigerator chamber slowly increasing, due to the heat transfer to the ambient. When the refrigerator temperature is out of the setting range, the compressor works again, and the refrigerator repeats this process until the end of its life. These on/off period can be controlled through the compressor piston movement. To determine the optimal compressor operating conditions, experiments of monthly power consumption were conducted under various compressor working times and the lowest power consumption conditions was determined when the compressor worked continuously. Lubricating oil, the refrigerator system, using oil, also influenced the system performance. To evaluate the effect of oil, oil eliminated and oil systems were compared based on cooling capacity and power consumption. The cooling capacity of the oil eliminated system was 2.6% higher and the power consumption was 3.6% lower than that of the oil system. After determining the optimal operating conditions of the refrigerator system, visualization experiments and simulations were conducted to decide the optimal evaporator and the conventional evaporator size can be reduced by approximately 2.9%.


Materials ◽  
2021 ◽  
Vol 14 (6) ◽  
pp. 1546
Author(s):  
Árpád Imre-Lucaci ◽  
Melinda Fogarasi ◽  
Florica Imre-Lucaci ◽  
Szabolcs Fogarasi

This paper presents a novel approach for the recovery of lead from waste cathode-ray tube (CRT) glass by applying a combined chemical-electrochemical process which allows the simultaneous recovery of Pb from waste CRT glass and electrochemical regeneration of the leaching agent. The optimal operating conditions were identified based on the influence of leaching agent concentration, recirculation flow rate and current density on the main technical performance indicators. The experimental results demonstrate that the process is the most efficient at 0.6 M acetic acid concentration, flow rate of 45 mL/min and current density of 4 mA/cm2. The mass balance data corresponding to the recycling of 10 kg/h waste CRT glass in the identified optimal operating conditions was used for the environmental assessment of the process. The General Effect Indices (GEIs), obtained through the Biwer Heinzle method for the input and output streams of the process, indicate that the developed recovery process not only achieve a complete recovery of lead but it is eco-friendly as well.


Sign in / Sign up

Export Citation Format

Share Document