apparent stiffness
Recently Published Documents


TOTAL DOCUMENTS

68
(FIVE YEARS 21)

H-INDEX

14
(FIVE YEARS 1)

Polymers ◽  
2022 ◽  
Vol 14 (2) ◽  
pp. 337
Author(s):  
Enrique Cuan-Urquizo ◽  
Alberto Álvarez-Trejo ◽  
Andrés Robles Robles Gil ◽  
Viridiana Tejada-Ortigoza ◽  
Carmita Camposeco-Negrete ◽  
...  

Fused deposition modeling (FDM) uses lattice arrangements, known as infill, within the fabricated part. The mechanical properties of parts fabricated via FDM are dependent on these infill patterns, which make their study of great relevance. One of the advantages of FDM is the wide range of materials that can be employed using this technology. Among these, polylactic acid (PLA)-wood has been recently gaining attention as it has become commercially available. In this work, the stiffness of two different lattice structures fabricated from PLA-wood material using FDM are studied: hexagonal and star. Rectangular samples with four different infill densities made of PLA-wood material were fabricated via FDM. Samples were subjected to 3-point bending to characterize the effective stiffness and their sensitivity to shear deformation. Lattice beams proved to be more sensitive to shear deformations, as including the contribution of shear in the apparent stiffness of these arrangements leads to more accurate results. This was evaluated by comparing the effective Young’s modulus characterized from 3-point bending using equations with and without shear inclusion. A longer separation between supports yielded closer results between both models (~41% for the longest separation tested). The effective stiffness as a function of the infill density of both topologies showed similar trends. However, the maximum difference obtained at low densities was the hexagonal topology that was ~60% stiffer, while the lowest difference was obtained at higher densities (star topology being stiffer by ~20%). Results for stiffness of PLA-wood samples were scattered. This was attributed to the defects at the lattice element level inherent to the material employed in this study, confirmed via micro-characterization.


Author(s):  
D N Ingle ◽  
M E Porter

Abstract Since their appearance in the fossil record 34 Mya, modern cetaceans (dolphins, whales, and porpoises) have radiated into diverse habitats circumglobally, developing vast phenotypic variations among species. Traits such as skeletal morphology and ecologically-linked behaviors denote swimming activity; trade-offs in flexibility and rigidity along the vertebral column determine patterns of caudal oscillation. Here, we categorized 10 species of cetaceans (Families Delphinidae and Kogiidae; N = 21 animals) into functional groups based on vertebral centra morphology, swimming speeds, diving behavior, and inferred swimming patterns. We quantified trabecular bone mechanical properties (yield strength, apparent stiffness, and resilience) among functional groups and regions of the vertebral column (thoracic, lumbar, and caudal). We extracted 6 mm3 samples from vertebral bodies and tested them in compression in three orientations (rostrocaudal, dorsoventral, and mediolateral) at 2 mm min−1. Overall, bone from the pre-fluke/fluke boundary had the greatest yield strength and resilience, indicating that the greatest forces are translated to the tail during caudal oscillatory swimming. Group 1, composed of five shallow-diving delphinid species, had the greatest vertebral trabecular bone yield strength, apparent stiffness, and resilience of all functional groups. Conversely, Group 3, composed of two deep-diving kogiid species, had the least strong, stiff, and resilient bone, while Group 2 (three deep-diving delphinid species) exhibited intermediate values. These data suggest that species that incorporate prolonged glides during deep descents in the water column actively swim less, and place relatively smaller loads on their vertebral columns, compared with species that execute shallower dives. We found that cetacean vertebral trabecular bone properties differed from the properties of terrestrial mammals; for every given bone strength, cetacean bone was less stiff by comparison. This relative lack of material rigidity within vertebral bone may be attributed to the non-weight bearing locomotor modes of fully aquatic mammals.


2021 ◽  
pp. 531-536
Author(s):  
Jordan Smith ◽  
Robert Felmlee ◽  
Jozsef Laczko ◽  
Mary Crowe ◽  
Scott Steinbrink ◽  
...  

2021 ◽  
Vol 4 (1) ◽  
Author(s):  
Yashar Bashirzadeh ◽  
Steven A. Redford ◽  
Chatipat Lorpaiboon ◽  
Alessandro Groaz ◽  
Hossein Moghimianavval ◽  
...  

AbstractThe proteins that make up the actin cytoskeleton can self-assemble into a variety of structures. In vitro experiments and coarse-grained simulations have shown that the actin crosslinking proteins α-actinin and fascin segregate into distinct domains in single actin bundles with a molecular size-dependent competition-based mechanism. Here, by encapsulating actin, α-actinin, and fascin in giant unilamellar vesicles (GUVs), we show that physical confinement can cause these proteins to form much more complex structures, including rings and asters at GUV peripheries and centers; the prevalence of different structures depends on GUV size. Strikingly, we found that α-actinin and fascin self-sort into separate domains in the aster structures with actin bundles whose apparent stiffness depends on the ratio of the relative concentrations of α-actinin and fascin. The observed boundary-imposed effect on protein sorting may be a general mechanism for creating emergent structures in biopolymer networks with multiple crosslinkers.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Morteza Amini ◽  
Andreas Reisinger ◽  
Lena Hirtler ◽  
Dieter Pahr

Abstract Background Experimental validation is the gold standard for the development of FE predictive models of bone. Employing multiple loading directions could improve this process. To capture the correct directional response of a sample, the effect of all influential parameters should be systematically considered. This study aims to determine the impact of common experimental parameters on the proximal femur’s apparent stiffness. Methods To that end, a parametric approach was taken to study the effects of: repetition, pre-loading, re-adjustment, re-fixation, storage, and μCT scanning as random sources of uncertainties, and loading direction as the controlled source of variation in both stand and side-fall configurations. Ten fresh-frozen proximal femoral specimens were prepared and tested with a novel setup in three consecutive sets of experiments. The neutral state and 15-degree abduction and adduction angles in both stance and fall configurations were tested for all samples and parameters. The apparent stiffness of the samples was measured using load-displacement data from the testing machine and validated against marker displacement data tracked by DIC cameras. Results Among the sources of uncertainties, only the storage cycle affected the proximal femoral apparent stiffness significantly. The random effects of setup manipulation and intermittent μCT scanning were negligible. The 15∘ deviation in loading direction had a significant effect comparable in size to that of switching the loading configuration from neutral stance to neutral side-fall. Conclusion According to these results, comparisons between the stiffness of the samples under various loading scenarios can be made if there are no storage intervals between the different load cases on the same samples. These outcomes could be used as guidance in defining a highly repeatable and multi-directional experimental validation study protocol.


2021 ◽  
Vol 15 (5) ◽  
pp. 590-598
Author(s):  
Nikolas Alexander Theissen ◽  
Monica Katherine Gonzalez ◽  
Asier Barrios ◽  
Andreas Archenti ◽  
◽  
...  

This article presents a procedure for the quasi-static compliance calibration of serial articulated industrial manipulators. Quasi-static compliance refers to the apparent stiffness displayed by manipulators at low-velocity movements, i.e., from 50 to 250 mm/s. The novelty of the quasi-static compliance calibration procedure lies in the measurement phase, in which the quasi-static deflections of the manipulator’s end effector are measured under movement along a circular trajectory. The quasi-static stiffness might be a more applicable model parameter, i.e., representing the actual manipulator more accurately, for manipulators at low-velocity movements. This indicates that the quasi-static robot model may yield more accurate estimates for the trajectory optimization compared with static stiffness in the implementation phase. This study compares the static and apparent quasi-static compliance. The static deflections were measured at discretized static configurations along circular trajectories, whereas the quasi-static deflections were measured under circular motion along the same trajectories. Loads of different magnitudes were induced using the Loaded Double Ball Bar. The static and quasi-static displacements were measured using a linear variable differential transformer embedded in the Loaded Double Ball Bar and a Leica AT901 laser tracker. These measurement procedures are implemented in a case study on a large serial articulated industrial manipulator in five different positions of its workspace. This study shows that the measured quasi-static deflections are bigger than the measured static deflections. This, in turn, indicates a significant difference between the static and apparent quasi-static compliance. Finally, the implementation of the model parameters to improve the accuracy of robots and the challenges in realizing cost-efficient compliance calibration are discussed.


PLoS ONE ◽  
2021 ◽  
Vol 16 (6) ◽  
pp. e0248256
Author(s):  
Seth H. Weinberg ◽  
Navpreet Saini ◽  
Christopher A. Lemmon

Assembly of the extracellular matrix protein fibronectin (FN) into insoluble, viscoelastic fibrils is a critical step during embryonic development and wound healing; misregulation of FN fibril assembly has been implicated in many diseases, including fibrotic diseases and cancer. We have previously developed a computational model of FN fibril assembly that recapitulates the morphometry and mechanics of cell-derived FN fibrils. Here we use this model to probe two important questions: how is FN fibril formation affected by the contractile phenotype of the cell, and how is FN fibril formation affected by the stiffness of the surrounding tissue? We show that FN fibril formation depends strongly on the contractile phenotype of the cell, but only weakly on in vitro substrate stiffness, which is an analog for in vivo tissue stiffness. These results are consistent with previous experimental data and provide a better insight into conditions that promote FN fibril assembly. We have also investigated two distinct phenotypes of FN fibrils that we have previously identified; we show that the ratio of the two phenotypes depends on both substrate stiffness and contractile phenotype, with intermediate contractility and high substrate stiffness creating an optimal condition for stably stretched fibrils. Finally, we have investigated how re-stretch of a fibril affects cellular response. We probed how the contractile phenotype of the re-stretching cell affects the mechanics of the fibril; results indicate that the number of myosin motors only weakly affects the cellular response, but increasing actin velocity results in a decrease in the apparent stiffness of the fibril and a decrease in the stably-applied force to the fibril. Taken together, these results give novel insights into the combinatorial effects of substrate stiffness and cell contractility on FN fibril assembly.


2021 ◽  
Author(s):  
Yuanqiao Wu ◽  
Elise Feng-i Morgan ◽  
Johnfredy Loaiza ◽  
Rohin Banerji ◽  
Olivia Rose Blouin

Background: Although deformation and fracture of the vertebral endplate have been implicated in spinal conditions such as vertebral fracture and disc degeneration, few biomechanical studies of this structure are available. The goal of this study was to quantify the mechanical behavior of the vertebral endplate. Methods: Eight-five rectangular specimens were dissected from the superior and/or inferior central endplates of human lumbar spine segments L1-L4. Micro-computed tomography (μCT) imaging, four-point-bend testing, and ashing were performed to quantify the apparent elastic modulus and yield stress (modulus and yield stress, respectively, of the porous vertebral endplate), tissue yield stress (yield stress of the tissue of the vertebral endplate, excluding pores), ultimate strain, fracture strain, bone volume fraction (BV/TV), bone mineral density (BMD), and various measures of tissue density and composition (tissue mineral density, ash fraction, and ash density). Regression was used to assess the dependence of mechanical properties on density and composition. Results: Wide variations in elastic and failure properties, and in density and tissue composition, were observed. BMD and BV/TV were good predictors of many of the apparent-level mechanical properties, including modulus, yield stress, and in the case of the inferior vertebral endplate, failure strains. Similar values of the mechanical properties were noted between superior and inferior vertebral endplates. In contrast to the dependence of apparent stiffness and strength on BMD and BV/TV, none of the mechanical properties depended on any of the tissue-level density measurements. Conclusion: The dependence of many of the mechanical properties of the vertebral endplate on BV/TV and BMD suggests possibilities for non-invasive assessment of how this region of the spine behaves during habitual and injurious loading. Further study of the non-mineral components of the endplate tissue is required to understand how the composition of this tissue may influence the overall mechanical behavior of the vertebral endplate.


2021 ◽  
Vol 12 (1) ◽  
Author(s):  
Nino F. Läubli ◽  
Jan T. Burri ◽  
Julian Marquard ◽  
Hannes Vogler ◽  
Gabriella Mosca ◽  
...  

AbstractQuantitative micromechanical characterization of single cells and multicellular tissues or organisms is of fundamental importance to the study of cellular growth, morphogenesis, and cell-cell interactions. However, due to limited manipulation capabilities at the microscale, systems used for mechanical characterizations struggle to provide complete three-dimensional coverage of individual specimens. Here, we combine an acoustically driven manipulation device with a micro-force sensor to freely rotate biological samples and quantify mechanical properties at multiple regions of interest within a specimen. The versatility of this tool is demonstrated through the analysis of single Lilium longiflorum pollen grains, in combination with numerical simulations, and individual Caenorhabditis elegans nematodes. It reveals local variations in apparent stiffness for single specimens, providing previously inaccessible information and datasets on mechanical properties that serve as the basis for biophysical modelling and allow deeper insights into the biomechanics of these living systems.


Sign in / Sign up

Export Citation Format

Share Document