scholarly journals Kualitas air sumur gali ditinjau dari parameter mikrobiologis di tepi sungai gajah wong yogyakarta

2018 ◽  
Vol 2 (2) ◽  
pp. 8-15
Author(s):  
Amyati Amyati

This study aims to identify the bacteria Escherichia coli in the water dug wells owned by residents on the banks of the gajah wong river, Kotagede-Yogyakarta. Bacteria Eschericia coli is one cause of diarrhea that need to know its existence to prevention of diarrhea. This research used descriptive analytics.The results showed, all the well water as a positive contain Eschericia Coli. The closer the distance between the well and the river, the higher the content ofEschericia.Coli. 50% of dug well water sampled is still feasible for consumption because the content of Escherichia coli is still less than 50 MPN/100ml

2021 ◽  
Vol 8 (2) ◽  
pp. 96
Author(s):  
Hagar Karlani ◽  
Fahrul Fahrul ◽  
Maria M Meiwati ◽  
Herianus Manimoy ◽  
Loth Botahala

Clean water is one of the human's main needs. Dug well water in Tombang, used for various needs. However, the dug well water has been polluted by E. Coli bacteria which is suspected to be due to the disposal of rubbish and waste carelessly and also the distance of latrines and dug wells that are very close together. Therefore it is important to do water purification using agricultural waste that is not utilized. The analysis showed that the purification of dug well water in Tombang with rice husk charcoal had reduced E. Coli bacteria by 55.6% with MPN pattern 1-0-3 so that the MPN value was 11/100 mL of sample.


BioScience ◽  
2018 ◽  
Vol 2 (1) ◽  
pp. 41 ◽  
Author(s):  
Dadan Supardan

Dug well water generally is a daily source of domestic water used by most households in Indonesia. However, the well water excavation does not meet the quality of health standards. Contamination of microorganism in dug well water occurs due to the distance of wells with septic tank, household waste disposal and animal husbandry. One of the bioindicators of contaminated groundwater is the presence of Coliform bacteria in large quantities, such as Escherichia coli, which potentially cause various diseases in human. The objective of this study was to determine the biological contamination of dug wells water in Ungga, Iting Bengkel Village, Central Lombok. This study was observational study and sampling method used purposive sampling with the number of samples was 6 dug wells. The biological contamination indicator was determined by calculating the index of Most Probable Number (MPN) Coliform. The laboratory analysis included the analysis Escherichia coli by MPN. The result showed that a total of 6 wells with distance 3.45 meters and 4.70 meters against septic tank has MPN coliform value 1898 per 100 ml. The result of water samples from 2 dug wells has contaminated by Escherichia Coli and has reached amount 14 per 100 ml (A3) and 16 per 100 ml (B3).   


2019 ◽  
Vol 7 (2) ◽  
pp. 115
Author(s):  
Dini Yuliansari

The well is one of the source water used for bathing, washing, and drinking by the citizens in Jiken Hamlet, Rarang Village, Terara Sub-District. Poor dug well construction conditions can affect the amount of coliform bacteria contained in the dug well water. The purpose of this study is to identify the construction of dug wells and the content of coliform bacteria in dug well water and determine the relationship between dug well construction and the content of coliform bacteria. This research is analytic with a cross sectional study design. The results were obtained from 11 samples of dug wells which were observed in construction and the coliform content was known that all samples did not requirements as good dug well construction. Coliform content test results showed that as many as 5 dug well water samples did not pass the clean water quality standards. The results of data analysis with the chi-square test variable construction of dug wells with coliform content variable  showed 0,172 > 0,05, then the concluded is the dug well not suitable to use by people in that area as a source of water for daily needs.


2021 ◽  
Vol 9 (E) ◽  
pp. 1224-1227
Author(s):  
Mulyadi Mulyadi ◽  
Zaenab Zaenab ◽  
Ain Khaer ◽  
Zrimurti Mappau ◽  
Adriyani Adam

BACKGROUND: Based on the results of laboratory examinations, initial samples taken from one of the clean water sources (dug wells) in Biringere Village, North Sinjai District, results showed that the water sample contained high enough metal ions such as Fe, Mn, hardness, and organic substances which did not meet the requirements as clean water because it still contained levels of Manganese (Mn) 1.68 mg/l. Meanwhile, for organic substances (KMnO4), it is 9876 mg/l. AIM: The purpose of the research was to determine the effectiveness of multimedia filters in improving quality of clean water from the parameters of Mn and KMnO4 in clean water sources (dug wells).. METHODS: The type of research conducted is quasi-experimental by made a filtering processing method with a “Up Flow” flow system, using media consisting of silica sand, zeolite, resin (pine resin), and active carbon in PVC tubes. The population in this study were all dug wells in North Sinjai district. The samples were dug wells located on Biringere Village, North Sinjai District. The samples examined in Center for Environmental Health and disease control of Makassar. RESULTS: The results obtained were that there was a significant change in manganese (Mn) levels of 0.49 mg/l (80.37%). Meanwhile, organic substances (MnO4) amounted to 17.38 mg/l (70.02%). CONCLUSION: Decreasing levels of manganese (Mn) in well water after going through the multimedia filter process above show that the manganese content has met the standard requirements of the Minister of Health Regulation No. 32 of 2017.


2020 ◽  
Vol 6 (2) ◽  
pp. 186-195
Author(s):  
Yusdiah Sari ◽  
Nurbaity Situmorang

Clean water needs one of which can be obtained through a dug well. As for things that need to be considered in the use of dug wells that meet health requirements. This is intended to minimize the occurrence of well water contamination caused by contaminants that exist around the dug well. The purpose of conducting this research was to analyze the influence caused by the dintance of the cattle pen with the presence of total Coliform bacteria in the dug wells of Klambir Village. This study used an observational analytic method with a cross sectional design. The study were used 35 samples and it was determined by simple random sampling. The results obtained from the research that from 35 samples examined entirely contain Coliform. In detail can be explained that as much as 22 wells (62.9%) had total coliforms 50/100 ml and 13 wells (37.1%) had total coliforms ≤ 50/100 ml of water. The results of multiple logistic regression analysis showed that there was an effect of enclosure distance on total coliform in dug well water.


2020 ◽  
Vol 6 (1) ◽  
Author(s):  
Ranno Marlany Rachman ◽  
Abdul Rahim Syaban

Air sumur gali oleh masyarakat digunakan sebagai sumber air minum dan air bersih untuk keperluan sehari-hari. Air sumur gali yang digunakan masyarakat di Kelurahan Lalolara memiliki tingkat kekeruhan sebesar 56 NTU. Kekeruhan tersebut belum memenuhi persyaratan air bersih berdasarkan Peraturan Menteri Kesehatan Nomor 32 Tahun 2017 tentang Persyaratan Kualitas Air Bersih sebesar 25 NTU. Adapun tujuan dari penelitian ini adalah untuk mengetahui efektivitas penggunaan dosis Kalsium karbonat (CaCO3) dan Poly Alumunium Cloride (PAC) dalam menjernihkan sumur gali. Hasil penelitian untuk komposisi kapur maupun PAC untuk dosis 5g/L 10 gr/L, 15 g/L masih belum efektif menurunkan tingkat kekeruhan sesuai baku mutu peraturan yang ada, sedangkan untuk dosis dan 20 g/L sudah efektif menjernihkan air sumur gali sesuai ketentuan peraturan yang berlaku. Kata Kunci: Air sumur, kapur, PAC. Dug well water by the community is used as a source of drinking water and clean water for daily needs. The dug well water used by the community in the Lalolara Village has a turbidity level of 56 NTU. This turbidity has not met the clean water requirements based on the Minister of Health Regulation Number 32 the Year 2017 concerning Clean Water Quality Requirements of 25 NTU. The purpose of this study is to determine the use of Calcium Carbonate (CaCO3) and Poly Aluminum Chloride (PAC) doses in clearing dug wells. The results of the study for the composition of lime or PAC for a dose of 5g / L 10 gr / L, 15 g / L is still not effective in reducing the turbidity level in accordance with the existing quality standards, whereas for doses and 20 g / L it has been effective in purifying dug well water according to the provisions applicable regulation Keywords: Lime, PAC, well water.


2020 ◽  
Vol 3 (1) ◽  
pp. 5
Author(s):  
Dirga Rangga Malindo ◽  
G M Saragih ◽  
Anggrika Riyanti

Efforts to monitor and supervise the quality of dug well water is an important part in meeting the need for clean water. This study is to determine the effect of sanitation and dug well construction on well water quality. Samples of well water quality were taken at wells with poor and poor sanitation and construction conditions based on SNI 03-2916-1992 concerning Dug Well Specifications. Water quality analysis was carried out in Jambi Province Regional Laboratory in accordance with Permenkes 32 of 2017 concerning About the environmental health quality standards and water health requirements for the needs of Sanitary Hygiene, Swimming Pool, Solus per Aqua, and Public Baths. Sanitation inspection to see the level of pollution risk refers to Permenkes Number 736 of 2010 concerning Management Procedures for Drinking Water Quality at dug well facilities. Laboratory test results show that wells with good sanitation and construction have good water quality compared to wells with poor sanitation and construction. However, both water quality samples still meet the Minister of Health Regulation 32 of 2017. Based on the results of sanitation inspection in the field as many as 63% of wells have a high level of pollution risk (High TRP), most of the dug wells have problems in their construction, to reduce the level of risk of dug well pollution needs improvement construction. In the planning and preparation of the Budget Plan for repairs to construction required a fee of Rp. 1,057,703,764, - these costs refer to Minister of Public Works Regulation No. 11 / PRT / M / 2013 Concerning guidelines for unit price analysis in the field of public works and repair of dug wells in accordance with SNI 03-2916-1992 Dug Well Specifications for Drinking Water Sources.


Author(s):  
Meisura Marlinda ◽  
Anita Dewi Moelyaningrum ◽  
Ellyke Ellyke

Abstract: The Coliform and Escherichia coli in Dug Well Water and Artesian Well. The quality of well water is related to public health problems. One of the causes of contaminated well water due to contamination by microorganisms, such as Coliform and E. coli bacteria. The quality of well water that is potentially polluted is one of the wells dug at the Slaughterhouse. The purpose of this study was to describe the factors related to the presence of Coliform and E. coli bacteria in wells dug in RPH in Jember Regency. This research is a descriptive research. Data collection techniques are carried out by observation, interviews, measurements, and laboratory tests. Interviews were conducted with the managers of each RPH. Laboratory test results showed that 42% of positive well water contained Coliform bacteria and 75% E. coli bacteria. The construction of dug wells mostly does not meet the physical requirements of wells, the septic tanks do not meet the requirements because some slaughterhouses do not have septic tanks and distances of less than 11 meters, the latrines are mostly in good condition, the SPAL of Jember Regency is mostly in the condition is good, most of the groundwater level in RPH wells in Kabupaten Jember has a height of 1 to 5 meters, all types of soil in RP Jember Regency are of sand soil type, and rainfall is relatively high. The dugs wells contruction and the latrines should be reconstruction to meet the requirement of clean water for increase the public health.


Jurnal Dampak ◽  
2017 ◽  
Vol 14 (1) ◽  
pp. 62
Author(s):  
Reri Afrianita ◽  
Tivany Edwin ◽  
Aroiya Alawiyah

This research aims to analyze the effect of seawater intrusion with measurement of TDS dug well water in Padang Utara Subdistrict. The measurements of TDS carried out in three villages in Padang Utara Subdistrict, namely the Village are Air Tawar Barat, Ulak Karang Selatan, and Ulak Karang Utara with twice sampling frequency: on November 2015 and February 2016. TDS concentration in November 2015 is in the range of 20 to 9000.8 mg / L, while the measurement of TDS concentration in February 2016 is in the range of 160.8 to 735.2 mg / L. Measurement of TDS in November 2015 showed that there were three wells that indicated to seawater intrusion, i.e. the ULS 8 (1101.6 mg / L), ULS 9 (9000.8 mg / L), and ULU 6 (1926.4 mg / L). Correlation between TDS concentration with coastline distance have a value r amounted to 0,118-.095. The results showed that there are some wells that indicated to seawater intrusion along the coast in Padang Utara Subdistrict.Keywords : distance, dug wells Padang Utara Subdistrict, , seawater intrusion, TDSAbstrak-Penelitian ini bertujuan untuk menganalisis pengaruh intrusi air laut dengan pengukuran TDS pada air sumur gali di Kecamatan Padang Utara. Pengukuran TDS dilakukan di tiga kelurahan di Kecamatan Padang Utara yaitu Kelurahan Air Tawar Barat, Ulak Karang Selatan, dan Ulak Karang Utara dengan frekuensi pengambilan sampel sebanyak dua kali yaitu pada bulan November 2015 dan Februari 2016. Konsentrasi TDS pada November 2015 berada dalam rentang 20-9000,8 mg/L, sedangkan pengukuran konsentrasi TDS pada Februari 2016 berada dalam rentang 160,8-735,2 mg/L. Pengukuran TDS pada ovember 2015 menunjukkan bahwa terdapat tiga sumur yang yang terindikasi mengalami intrusi air laut, yaitu ULS 8 (1101,6 mg/L), ULS 9 (9000,8 mg/L), dan ULU 6 (1926,4 mg/L). Hubungan antara jarak sumur dari bibir pantai terhadap nilai TDS memiliki koefisien korelasi sebesar 0,118 0,095, hal ini menunjukkan tidak adanya pengaruh antara jarak dengan nilai TDS. Hasil penelitian menunjukkan bahwa terdapat beberapa sumur yang terindikasi mengalami intrusi air laut di sepanjang pesisir di Kecamatan Padang Utara.Kata kunci : intrusi air laut, jarak, Kecamatan Padang Utara, sumur gali, TDS


2020 ◽  
Vol 6 (2) ◽  
Author(s):  
Erlan Siswandi ◽  
Taufik Abdullah ◽  
Muhamad Majdi ◽  
Maskur Maskur

Kegiatan industri, kandang ternak, perilaku masyarakat dan aktivitas rumah tangga menghasilkan limbah yang terbuang ke sungai. Limbah tersebut meresap ke tanah dan menyebabkan terjadinya pencemaran air tanah. Penelitian ini dilaksanakan di Dusun Gubuk Timuk Desa Pohgading Kecamatan Pringgabaya. Tujuan penelitian ini yaitu: 1) untuk mengetahui rata-rata kandungan bakteri Coliform pada air sumur gali dengan variasi jarak 1-5 meter, 6-10 meter dan 11-15 meter dari sungai sebagai sumber pencemar, 2) untuk mengetahui hubungan antara jarak sungai dengan tingkat pencemaran pada sumur gali. Jumlah sampel 18 sumur dipilih secara acak. Data dikumpulkan dengan cara observasi dan dianalisis dengan teknik analisis kuantitatif. Dari hasil pemeriksaan sampel menunjukkan bahwa rata–rata kandungan bakteri Coliform pada air sumur gali Dusun Gubuk Timuk Desa Pohgading dengan jarak 1-5 meter dari sungai adalah 190/100ml, jarak 6-10 meter dari sungai adalah 90,875/100ml dan jarak 11-15 meter dari sungai adalah 51/100ml. Hasil pemeriksaan sampel tersebut sebagian besar tidak memenuhi kualitas sebagai air bersih, sesuai Permenkes 416/Menkes/Per/IX/1990 dengan kadar maksimal yang diperbolehkan adalah 50/100ml sebagai air non perpipaan. Kemudian hasil uji Anova dengan α = 0,02 menunjukkan bahwa terdapat hubungan antara jarak sungai sebagai sumber pencemar dengan kandungan Coliform pada sumur gali di Dusun Gubuk Timuk Desa Pohgading Kecamatan Pringgabaya. Kata kunci: Bakteri Coliform, jarak sungai, sumur gali.  Industrial activities, animal pens, community behavior and household activities produced waste into rivers. The waste seeps into the ground and couses groundwater pollution. This research was carried out in Gubuk Timuk Hamlet, Pohgading Village, Pringgabaya District. The study aims were: (1) to find out the average content of Coliform bacteria in dug well water with variations in distance of 1-5 meters, 6-10 meters and 11-15 meters from the river as a source of pollution, 2) to determine the relationship between river distance with level of pollution in dug wells. There were 18 well samples randomly selected. Data were collected by observation and analyzed using quantitative analysis techniques. The research results of the sample examination showed that the average content of Coliform bacteria in the dug well water of the Gubuk Timuk, Pohfading Village with a distance of 1-5 meters from the river was 190/100ml, a distance of 6-10 meters from the river was 90.875/100ml and a distance of 11-15 meters of the river was 51/100ml. Most of the samples examination did not meet the quality as clean water, according to Permenkes 416/Menkes/Per/IX/1990 with the maximum level allowed is 50/100ml as non-piped water. The Anova test results with α = 0.02 indicate that there is a relationship between the distance of  river as a source of pollutants and the Coliform content in dug wells in Gubuk Timuk Hamlet, Pohgading Village, Pringgabaya District. Keywords: Coliform bacteria, dug wells, river distance.


Sign in / Sign up

Export Citation Format

Share Document