scholarly journals Failure Trends of High-Voltage Porcelain Insulators Depending on the Constituents of the Porcelain

2020 ◽  
Vol 10 (2) ◽  
pp. 694 ◽  
Author(s):  
Simpy Sanyal ◽  
Taeyong Kim ◽  
Junsin Yi ◽  
Ja-Bin Koo ◽  
Ju-Am Son ◽  
...  

The aging of porcelain insulators is responsible for the failure of power utilities. Porcelain insulators from different places in South Korea, possessing various aging times and years of installation, have been investigated to carry out lifetime statistics. These samples have a mass of 36,000 lbs and are operated at 154 kV. X-ray fluorescence (XRF) and scanning electron microscopy (SEM) were performed on the porcelain bodies of the samples collected. XRF and SEM revealed trends in the weight percentage of SiO2, Al2O3, and Fe2O3 in the porcelain bodies of the collected samples. The SiO2 and Fe2O3 weight percentage reduced to 8.93% and 73.17%, respectively, in sample C compared to A. However, the Al2O3 weight percentage increased to 16.23% in sample C compared to sample A. This change in weight percentage of SiO2, Fe2O3, and Al2O3 contributed toward enhancing the mechanical and electrical properties of the insulators. Mechanical load tests with electrical voltage (M&E), thermal and mechanical load tests (T&M), and hardness tests (HRB) were performed to evaluate these characteristics. Experiments revealed an increase of 90.9% in the inequality factor (K) in sample C compared to A. The impact of constituents of porcelain on the lifetime expectancy of a porcelain insulator was reported by implementing statistical strategies, such as the Weibull distribution.

Cerâmica ◽  
2018 ◽  
Vol 64 (372) ◽  
pp. 570-576
Author(s):  
B. Ngayakamo ◽  
S. E. Park

Abstract This study evaluated the potential of locally sourced-ceramic raw materials in Tanzania, Pugu kaolin, Same clay, vermiculite and feldspar, for production of high voltage porcelain insulators. The chemical, mineral phases and microstructural characterization of raw materials and porcelain samples were carried out using the X-ray fluorescence, X-ray diffraction, and scanning electron microscopy techniques, respectively. The mineral phases of the fired porcelain sample identified were mullite and quartz. The porcelain bodies were fabricated using the dry pressing method by varying the composition of the selected ceramic raw materials. The physical-mechanical properties and dielectric strength were measured for each porcelain sample. The sample with the composition of 20% Pugu kaolin, 20% Same clay, 20% vermiculite and 40% feldspar was found to have the dielectric strength of 50.8 kV.mm-1, bending strength of 20 MPa and water absorption of 0.46%, which satisfies the main requisite properties for high voltage porcelain insulators.


Author(s):  
W. E. Lee ◽  
A. H. Heuer

IntroductionTraditional steatite ceramics, made by firing (vitrifying) hydrous magnesium silicate, have long been used as insulators for high frequency applications due to their excellent mechanical and electrical properties. Early x-ray and optical analysis of steatites showed that they were composed largely of protoenstatite (MgSiO3) in a glassy matrix. Recent studies of enstatite-containing glass ceramics have revived interest in the polymorphism of enstatite. Three polymorphs exist, two with orthorhombic and one with monoclinic symmetry (ortho, proto and clino enstatite, respectively). Steatite ceramics are of particular interest a they contain the normally unstable high-temperature polymorph, protoenstatite.Experimental3mm diameter discs cut from steatite rods (∼10” long and 0.5” dia.) were ground, polished, dimpled, and ion-thinned to electron transparency using 6KV Argon ions at a beam current of 1 x 10-3 A and a 12° angle of incidence. The discs were coated with carbon prior to TEM examination to minimize charging effects.


Author(s):  
Halit Dogan ◽  
Md Mahbub Alam ◽  
Navid Asadizanjani ◽  
Sina Shahbazmohamadi ◽  
Domenic Forte ◽  
...  

Abstract X-ray tomography is a promising technique that can provide micron level, internal structure, and three dimensional (3D) information of an integrated circuit (IC) component without the need for serial sectioning or decapsulation. This is especially useful for counterfeit IC detection as demonstrated by recent work. Although the components remain physically intact during tomography, the effect of radiation on the electrical functionality is not yet fully investigated. In this paper we analyze the impact of X-ray tomography on the reliability of ICs with different fabrication technologies. We perform a 3D imaging using an advanced X-ray machine on Intel flash memories, Macronix flash memories, Xilinx Spartan 3 and Spartan 6 FPGAs. Electrical functionalities are then tested in a systematic procedure after each round of tomography to estimate the impact of X-ray on Flash erase time, read margin, and program operation, and the frequencies of ring oscillators in the FPGAs. A major finding is that erase times for flash memories of older technology are significantly degraded when exposed to tomography, eventually resulting in failure. However, the flash and Xilinx FPGAs of newer technologies seem less sensitive to tomography, as only minor degradations are observed. Further, we did not identify permanent failures for any chips in the time needed to perform tomography for counterfeit detection (approximately 2 hours).


2021 ◽  
Vol 13 (1) ◽  
Author(s):  
Matthew G. Hanson ◽  
Barry Chan

Abstract Background Symptomatic pericardial effusion (PCE) presents with non-specific features and are often missed on the initial physical exam, chest X-ray (CXR), and electrocardiogram (ECG). In extreme cases, misdiagnosis can evolve into decompensated cardiac tamponade, a life-threatening obstructive shock. The purpose of this study is to evaluate the impact of point-of-care ultrasound (POCUS) on the diagnosis and therapeutic intervention of clinically significant PCE. Methods In a retrospective chart review, we looked at all patients between 2002 and 2018 at a major Canadian academic hospital who had a pericardiocentesis for clinically significant PCE. We extracted the rate of presenting complaints, physical exam findings, X-ray findings, ECG findings, time-to-diagnosis, and time-to-pericardiocentesis and how these were impacted by POCUS. Results The most common presenting symptom was dyspnea (64%) and the average systolic blood pressure (SBP) was 120 mmHg. 86% of people presenting had an effusion > 1 cm, and 89% were circumferential on departmental echocardiogram (ECHO) with 64% having evidence of right atrial systolic collapse and 58% with early diastolic right ventricular collapse. The average time-to-diagnosis with POCUS was 5.9 h compared to > 12 h with other imaging including departmental ECHO. Those who had the PCE identified by POCUS had an average time-to-pericardiocentesis of 28.1 h compared to > 48 h with other diagnostic modalities. Conclusion POCUS expedites the diagnosis of symptomatic PCE given its non-specific clinical findings which, in turn, may accelerate the time-to-intervention.


Materials ◽  
2021 ◽  
Vol 14 (1) ◽  
pp. 225
Author(s):  
Andrea Petrella ◽  
Michele Notarnicola

Lightweight cement mortars containing end-of-life tire rubber (TR) as aggregate were prepared and characterized by rheological, thermal, mechanical, microstructural, and wetting tests. The mixtures were obtained after total replacement of the conventional sand aggregate with untreated TR with different grain sizes (0–2 mm and 2–4 mm) and distributions (25%, 32%, and 40% by weight). The mortars showed lower thermal conductivities (≈90%) with respect to the sand reference due to the differences in the conductivities of the two phases associated with the low density of the aggregates and, to a minor extent, to the lack of adhesion of tire to the cement paste (evidenced by microstructural detection). In this respect, a decrease of the thermal conductivities was observed with the increase of the TR weight percentage together with a decrease of fluidity of the fresh mixture and a decrease of the mechanical strengths. The addition of expanded perlite (P, 0–1 mm grain size) to the mixture allowed us to obtain mortars with an improvement of the mechanical strengths and negligible modification of the thermal properties. Moreover, in this case, a decrease of the thermal conductivities was observed with the increase of the P/TR dosage together with a decrease of fluidity and of the mechanical strengths. TR mortars showed discrete cracks after failure without separation of the two parts of the specimens, and similar results were observed in the case of the perlite/TR samples thanks to the rubber particles bridging the crack faces. The super-elastic properties of the specimens were also observed in the impact compression tests in which the best performances of the tire and P/TR composites were evidenced by a deep groove before complete failure. Moreover, these mortars showed very low water penetration through the surface and also through the bulk of the samples thanks to the hydrophobic nature of the end-of-life aggregate, which makes these environmentally sustainable materials suitable for indoor and outdoor elements.


Polymers ◽  
2021 ◽  
Vol 13 (13) ◽  
pp. 2212
Author(s):  
Worawat Poltabtim ◽  
Ekachai Wimolmala ◽  
Teerasak Markpin ◽  
Narongrit Sombatsompop ◽  
Vichai Rosarpitak ◽  
...  

The potential utilization of wood/polyvinyl chloride (WPVC) composites containing an X-ray protective filler, namely bismuth oxide (Bi2O3) particles, was investigated as novel, safe, and environmentally friendly X-ray shielding materials. The wood and Bi2O3 contents used in this work varied from 20 to 40 parts per hundred parts of PVC by weight (pph) and from 0 to 25, 50, 75, and 100 pph, respectively. The study considered X-ray shielding, mechanical, density, water absorption, and morphological properties. The results showed that the overall X-ray shielding parameters, namely the linear attenuation coefficient (µ), mass attenuation coefficient (µm), and lead equivalent thickness (Pbeq), of the WPVC composites increased with increasing Bi2O3 contents but slightly decreased at higher wood contents (40 pph). Furthermore, comparative Pbeq values between the wood/PVC composites and similar commercial X-ray shielding boards indicated that the recommended Bi2O3 contents for the 20 pph (40 ph) wood/PVC composites were 35, 85, and 40 pph (40, 100, and 45 pph) for the attenuation of 60, 100, and 150-kV X-rays, respectively. In addition, the increased Bi2O3 contents in the WPVC composites enhanced the Izod impact strength, hardness (Shore D), and density, but reduced water absorption. On the other hand, the increased wood contents increased the impact strength, hardness (Shore D), and water absorption but lowered the density of the composites. The overall results suggested that the developed WPVC composites had great potential to be used as effective X-ray shielding materials with Bi2O3 acting as a suitable X-ray protective filler.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Mikolaj Grabowski ◽  
Ewa Grzanka ◽  
Szymon Grzanka ◽  
Artur Lachowski ◽  
Julita Smalc-Koziorowska ◽  
...  

AbstractThe aim of this paper is to give an experimental evidence that point defects (most probably gallium vacancies) induce decomposition of InGaN quantum wells (QWs) at high temperatures. In the experiment performed, we implanted GaN:Si/sapphire substrates with helium ions in order to introduce a high density of point defects. Then, we grew InGaN QWs on such substrates at temperature of 730 °C, what caused elimination of most (but not all) of the implantation-induced point defects expanding the crystal lattice. The InGaN QWs were almost identical to those grown on unimplanted GaN substrates. In the next step of the experiment, we annealed samples grown on unimplanted and implanted GaN at temperatures of 900 °C, 920 °C and 940 °C for half an hour. The samples were examined using Photoluminescence, X-ray Diffraction and Transmission Electron Microscopy. We found out that the decomposition of InGaN QWs started at lower temperatures for the samples grown on the implanted GaN substrates what provides a strong experimental support that point defects play important role in InGaN decomposition at high temperatures.


Nutrients ◽  
2021 ◽  
Vol 13 (2) ◽  
pp. 381
Author(s):  
Gautier Cesbron-Lavau ◽  
Aurélie Goux ◽  
Fiona Atkinson ◽  
Alexandra Meynier ◽  
Sophie Vinoy

During processing of cereal-based food products, starch undergoes dramatic changes. The objective of this work was to evaluate the impact of food processing on the starch digestibility profile of cereal-based foods using advanced imaging techniques, and to determine the effect of preserving starch in its native, slowly digestible form on its in vivo metabolic fate. Four different food products using different processing technologies were evaluated: extruded products, rusks, soft-baked cakes, and rotary-molded biscuits. Imaging techniques (X-ray diffraction, micro-X-ray microtomography, and electronic microscopy) were used to investigate changes in slowly digestible starch (SDS) structure that occurred during these different food processing technologies. For in vivo evaluation, International Standards for glycemic index (GI) methodology were applied on 12 healthy subjects. Rotary molding preserved starch in its intact form and resulted in the highest SDS content (28 g/100 g) and a significantly lower glycemic and insulinemic response, while the three other technologies resulted in SDS contents below 3 g/100 g. These low SDS values were due to greater disruption of the starch structure, which translated to a shift from a crystalline structure to an amorphous one. Modulation of postprandial glycemia, through starch digestibility modulation, is a meaningful target for the prevention of metabolic diseases.


2019 ◽  
Vol 15 (S356) ◽  
pp. 143-143
Author(s):  
Jaya Maithil ◽  
Michael S. Brotherton ◽  
Bin Luo ◽  
Ohad Shemmer ◽  
Sarah C. Gallagher ◽  
...  

AbstractActive Galactic Nuclei (AGN) exhibit multi-wavelength properties that are representative of the underlying physical processes taking place in the vicinity of the accreting supermassive black hole. The black hole mass and the accretion rate are fundamental for understanding the growth of black holes, their evolution, and the impact on the host galaxies. Recent results on reverberation-mapped AGNs show that the highest accretion rate objects have systematic shorter time-lags. These super-Eddington accreting massive black holes (SEAMBHs) show BLR size 3-8 times smaller than predicted by the Radius-Luminosity (R-L) relationship. Hence, the single-epoch virial black hole mass estimates of highly accreting AGNs have an overestimation of a factor of 3-8 times. SEAMBHs likely have a slim accretion disk rather than a thin disk that is diagnostic in X-ray. I will present the extreme X-ray properties of a sample of dozen of SEAMBHs. They indeed have a steep hard X-ray photon index, Γ, and demonstrate a steeper power-law slope, ασx.


Metals ◽  
2021 ◽  
Vol 11 (6) ◽  
pp. 925
Author(s):  
Diogo Heitor ◽  
Isabel Duarte ◽  
João Dias-de-Oliveira

X-ray microcomputed tomography has been gaining relevance in the field of cellular materials to characterize materials and analyse their microstructure. So, here, it was used together with finite element modelling to develop numerical models to estimate the effective properties (Young’s modulus) of aluminium alloy foams and evaluate the effects of processing on the results. A manual global thresholding technique using the mass as a quality indicator was used. The models were reconstructed (Marching Cubes 33), then simplified and analysed in terms of mass and shape maintenance (Hausdorff distance algorithm) and face quality. Two simplification procedures were evaluated, with and without small structural imperfections, to evaluate the impact of the procedures on the results. Results demonstrate that the developed procedures are good at minimizing changes in mass and shape of the geometries while providing good face quality, i.e., face aspect ratio. The models are also shown to be able to predict the effective properties of metallic foams in accordance with the findings of other researchers. In addition, the process of obtaining the models and the presence of small structural imperfections were shown to have a great impact on the results.


Sign in / Sign up

Export Citation Format

Share Document