scholarly journals Effect of Temperature on Material Properties of Carbon Fiber Reinforced Polymer (CFRP) Tendons: Experiments and Model Assessment

Materials ◽  
2019 ◽  
Vol 12 (7) ◽  
pp. 1025 ◽  
Author(s):  
Fei Zhou ◽  
Jiwen Zhang ◽  
Shoutan Song ◽  
Dong Yang ◽  
Chao Wang

Material properties at elevated temperatures are important factors in the fire safety design and numerical analysis of concrete members strengthened with fiber reinforced polymer (FRP) composites. Most of the previous research mainly focused on tensile strength and elastic modulus in conventional steady state temperature tests. However, the transient state test method is more realistic for strengthening concrete structures. At the same time, the coefficient of thermal expansion of FRP composites is also one of the important factors affecting concrete members at elevated temperatures. This paper presents a detailed experimental investigation on the longitudinal thermal expansion deformation, and the mechanical properties of carbon FRP (CFRP) tendons with 8 mm diameter in the steady state and transient state. The results indicate that longitudinal deformation of CFRP tendons is negative at high temperature; in addition, the transient state test results of CFRP tendons are slightly higher than the steady state test results. The final part of this paper assesses the accuracy of different empirical models. Furthermore, a new equation calculating the properties of CFRP composites at elevated temperatures is presented with the numerical fitting technique, which is in good agreement with the experimental results.

2021 ◽  
pp. 136943322110585
Author(s):  
Seyed Mehrdad Elhamnike ◽  
Rasoul Abbaszadeh ◽  
Vahid Razavinasab ◽  
Hadi Ziaadiny

Exposure of buildings to fire is one of the unexpected events during the life of the structure. The heat from the fire can reduce the strength of structural members, and these damaged members need to be strengthened. Repair and strengthening of concrete members by fiber-reinforced polymer (FRP) composites has been one of the most popular methods in recent years and can be used in fire-damaged concrete members. In this paper, in order to provide further data and information about the behavior of post-heated circular concrete columns confined with FRP composites, 30 cylindrical concrete specimens were prepared and subjected under four exposure temperatures of 300, 500, 700, and 900. Then, specimens were repaired by carbon fiber reinforced polymer composites and tested under axial compression. Results indicate that heating causes the color change, cracks, and weight loss of concrete. Also, with the increase of heating temperature, the shape of stress–strain curve of FRP-retrofitted specimens will change. Therefore, the main parts of the stress–strain curve such as ultimate stress and strain and the elastic modulus will change. Thus, a new stress–strain model is proposed for post-heated circular concrete columns confined by FRP composites. Results indicate that the proposed model is in a good agreement with the experimental data.


Materials ◽  
2021 ◽  
Vol 14 (8) ◽  
pp. 1903
Author(s):  
Danijela Stankovic ◽  
Luke A. Bisby ◽  
Giovanni P. Terrasi

The performance of pretensioned, laminated, unidirectional (UD), carbon fiber reinforced polymer (CFRP) straps, that can potentially be used for example as bridge deck suspender cables or prestressed shear reinforcements for reinforced concrete slabs and beams, was investigated at elevated temperatures. This paper aims to elucidate the effects of elevated temperature specifically on the tensile performance of pretensioned, pin-loaded straps. Two types of tests are presented: (1) steady state thermal and (2) transient state thermal. Eight steady-state target temperatures in the range of 24 °C to 600 °C were chosen, based on results from dynamic mechanical thermal analysis (DMTA) and thermogravimetric analysis (TGA). Transient state thermal tests were performed at three sustained tensile load levels, namely 10, 15, and 20 kN, corresponding to 25%, 37%, and 50% of the ultimate tensile strength of the pin-loaded straps at ambient temperature. In general, the straps were able to retain about 50% of their ambient temperature ultimate tensile strength (UTS) at 365 °C.


Polymers ◽  
2021 ◽  
Vol 13 (16) ◽  
pp. 2585
Author(s):  
Karolina Ogrodowska ◽  
Karolina Łuszcz ◽  
Andrzej Garbacz

This paper presents fiber-reinforced polymer composites which were modified by fibers hybridization as well as matrix nanomodifiaction with nanosilica. The article analyzed the nanosilica matrix modification and basalt-carbon hybridization’s effect on key properties of composites use as the main reinforcement in concrete structures. The comparative analysis was based on results of bars strength parameters determined in a shear test with the ASTM standard. The tests were performed for three bar diameters at room temperature and pre-heated FRP composites at 80 °C and 200 °C for 2 h with the aim of verifying the influence of the fiber hybridization-basalt-carbon fiber-reinforced polymer (HFRP) bars and the effect of nanosilica modification of the epoxy matrix (nHFRP). The test results were also compared with results of the shear test carried out after the bars were heated to 80 °C for 30 min in order to verify and evaluate the effect of the heating time. These types of tests are relevant to the conditions that occur in FRP composites when exposed to elevated temperatures.


2014 ◽  
Vol 1079-1080 ◽  
pp. 258-265
Author(s):  
Chen Ning Cai ◽  
Shan He ◽  
Li Na Liu ◽  
Shi Kun Ou

Thispaper presents an experimental study to strengthen an existing bridge usingpre-stressed carbon fiber reinforced polymer (CFRP) and glass fiber reinforced polymer(GFRP) materials. The method using pre-stressed hybrid fiber reinforced polymer(HFRP) to strengthened structural members is an emerging pre-stressed strengtheningtechnology. In this study, experimental data selected from result of staticloading test conducted to hollow slabs with CFRP/GFRP has been compared with specimenswithout strengthening. Test results showed that the strengthening methoddeveloped in this study could effectively reduce the stress in hollow slab,improving the flexural rigidity and inhibiting the concrete from fracture.


2021 ◽  
Vol 11 (6) ◽  
pp. 2736
Author(s):  
Min Sook Kim ◽  
Young Hak Lee

In this study, the structural behavior of reinforced concrete flat plates shear reinforced with vertical grids made of a glass fiber reinforced polymer (GFRP) was experimentally evaluated. To examine the shear strength, experiments were performed on nine concrete slabs with different amounts and spacings of shear reinforcement. The test results indicated that the shear strength increased as the amount of shear reinforcement increased and as the spacing of the shear reinforcement decreased. The GFRP shear reinforcement changed the cracks and failure mode of the specimens from a brittle punching to flexure one. In addition, the experimental results are compared with a shear strength equation provided by different concrete design codes. This comparison demonstrates that all of the equations underestimate the shear strength of reinforced concrete flat plates shear reinforced with GFRP vertical grids. The shear strength of the equation by BS 8110 is able to calculate the punching shear strength reasonably for a concrete flat plate shear reinforced with GFRP vertical grids.


2021 ◽  
pp. 136943322199249
Author(s):  
Xing Li ◽  
Jiwen Zhang ◽  
Jun Cheng

This paper presents fatigue behaviors and the stiffness degradation law of concrete continuous beams with external prestressed carbon fiber-reinforced polymer (CFRP) tendons. Three specimens were tested under fatigue loading, and the influence of different load levels on the stiffness degradation and fatigue life were studied, and it was found that the stiffness degradation of three test specimens exhibited a three-stage change rule, namely rapid decrease, stable degradation, and sharp decline, but there are obvious differences in the rate and amplitude of stiffness degradation. The load level has a significant influence on the fatigue life of the test specimens. An analytical model with load level considered was proposed to calculate the residual stiffness and predict the stiffness degradation, which is in good agreement with the test results. The model of stiffness degradation presents a possible solution for practical engineering applications of concrete continuous beams with externally prestressed CFRP tendons subjected to different fatigue loadings.


2017 ◽  
Vol 747 ◽  
pp. 220-225
Author(s):  
Alberto Pedro Busnelli ◽  
Ruben Edgardo López ◽  
Jorge Carlos Adue

This is the presentation of the research carried out by the Faculty of Engineering at Universidad Nacional de Rosario on the use of pultruded Glass Fiber Reinforced Polymer (GFRP) plates to increase the flexural strength of reinforced concrete beams.Pultruded plates are the type of elements made of composite materials which are most widely used for this kind of strengthening. Although around the world the material used for these plates is carbon fibers, its high cost prevents its widespread use in our country.One of the aims of our research program is, precisely, to verify whether it is possible to substitute such plates for significantly cheaper glass fiber elements manufactured in Argentina. The test results have proved that this alternative is feasible.What's more, the greater thickness of the glass fiber plates allows the use of additional anchor bolts. These bolts provide the system with post-critical resistance and ductility-characteristics which are absolutely necessary, for example, in structures in seismic areas.


2017 ◽  
Vol 2017 ◽  
pp. 1-14 ◽  
Author(s):  
S.-K. Lee ◽  
S.-Y. Yoo ◽  
C.-G. Park

This study evaluated the performance of a hybrid panel that can overcome the current problem of corrosion of the steel panels of improved movable weirs when they are exposed to a sulfate and calcium chloride environment such as sea water. A hybrid panel with glass fiber-reinforced polymer (GFRP) layers on both sides of a steel panel means that the central panel is not exposed to the external elements, which can avoid corrosion problems. In this study, to maximize the hybrid panel’s strength and durability, the moisture absorption characteristics and the durability in an accelerated environment were evaluated. The test results were considered to indicate no durability issues as the final absorption ratio was approximately 2.0% or less in all environments. Also, from the accelerated deterioration test results when the steel panel processed by sand blasting was applied in all accelerated deterioration environments, it satisfied the residual strength level of 65% or more. However, in the case without surface processing, upon exposure to MgSO4 solution, it did not satisfy the standard residual strength level of 65%. These results show that sand blasting on the surface of a steel panel is adequate for hybrid panels for improved movable weirs.


2011 ◽  
Vol 18 (1-2) ◽  
pp. 69-77 ◽  
Author(s):  
Sevket Ozden ◽  
Hilal Meydanli Atalay

AbstractThe strength and post-peak performance of reinforced concrete corbels, strengthened with epoxy bonded glass fiber reinforced polymer (GFRP) overlays, were experimentally investigated. The test variables were the corbel shear span to depth ratio, corbel main reinforcement ratio, and the number and orientation of the GFRP fibers. In total, 24 normal strength concrete, one-third scale, corbel specimens, without hoop reinforcement, were tested to failure under quasi-static gravity loading. Test results revealed that GFRP overlays can easily be used for the enhancement of corbel load bearing capacity, depending on the fiber orientation. The main reinforcement ratio and the number of GFRP plies were found to be the two main variables affecting the level of strength gain in the corbel specimens.


2016 ◽  
Vol 78 (5-2) ◽  
Author(s):  
Meng Jing ◽  
Werasak Raongjant

The objective of this research work is to determine the effect of wet-dry cycling on bond behavior of historic masonry structures strengthened by Glass Fiber Reinforced Polymer (GFRP). Shear bond testing was carried out through total 36 specimens exposed to dry, full moisture or wet-dry cycling conditions.  The selected samples were then tested at 0, 30, 60 and 90 days. Post-ageing test was also preceded on total sixty masonry prisms exposed to dry, full moisture or wet-dry cycling conditions. The compressive strengths of selected samples were then tested at 0, 40, 70 and 100 days. The test results showed an obvious decrease of the bond strength between GFRP sheets and bricks in the wet-dry cycling condition. For masonry prisms with or without GFRP strengthening, in the first 40 days, the compressive strength of GFRP bonded prism decreased quickly to the value near that of prism without GFRP. After 40 days the rate of decrease became slow, which means that, sheets retrofitted outside the masonry prisms helped to improve their durability by reducing water permeation. 


Sign in / Sign up

Export Citation Format

Share Document