scholarly journals Visual behavior and upper limb variability in coordination comparision between novices and experts performers in basketball free throws

2021 ◽  
Vol 3 (5) ◽  
pp. 2832-2841
Author(s):  
Alejandro Troncoso T ◽  
Christian Cancino B ◽  
Juan José Marimán ◽  
Joel Álvarez-Ruf

The objective of the present research is to determine the differences in  visual behavior  and the upper limbs variability in coordination  between expert performers and novice performers in basketball free throws. Methods: Nine right-handed men were tested. The skilled group consisted of four players who had an experience of 9.2 years (SD: 1.2) and play 9 hours per week (SD: 12). The novice group consisted of five players with no experience in Basketball. Visual behavior was evaluated using an eye-tracker head mounted and the upper limb kinematic behavior using a High-speed camera during 30 free throws. Results: There was a significant difference between the expert and novice performers in accuracy for the 30 trials (p<0.034). In Visual behavior  were no significant differences the  duration of the last visual fixation before the onset of elbow extension in execution phase (p>0,05) between expert and novice groups. There were statistically significant differences in the elbow-wrist variability in coordination in the throws duration time-windows of 100%, 90%, 80%, 30% (pvalue <0.05). 100% represent the last time-windows before ball release. The expert performers shows greater consistency in coordination, however novice subjects exhibit greater variability in the coordination in these intervals. Conclusion: The results suggest that the task of shooting free throws requires a long visual fixation to the site of interest, which temporarily is similar in subjects with different levels of skill. The higher reproducibility pattern suggests elbow-wrist coordination to be the key perceptuo-motor behavior in order to reach expert performance.   El objetivo de la presente investigación es determinar las diferencias en el comportamiento visual y la variabilidad de los miembros superiores en la coordinación entre ejecutantes expertos y ejecutantes novatos en los tiros libres de baloncesto. Métodos: Se examinaron nueve hombres diestros. El grupo de expertos estaba formado por cuatro jugadores que tenían una experiencia de 9,2 años (SD: 1,2) y jugaban 9 horas a la semana (SD: 12). El grupo de novatos estaba formado por cinco jugadores sin experiencia en baloncesto. El comportamiento visual fue evaluado utilizando un eye-tracker montado en la cabeza y el comportamiento cinemático del miembro superior utilizando una cámara de alta velocidad durante 30 tiros libres. Resultados: Hubo una diferencia significativa entre los expertos y los novatos en la precisión de los 30 ensayos (p<0,034). En el comportamiento visual no hubo diferencias significativas en la duración de la última fijación visual antes del inicio de la extensión del codo en la fase de ejecución (p>0,05) entre los grupos de expertos y novatos. Hubo diferencias estadísticamente significativas en la variabilidad codo-muñeca en la coordinación en las ventanas de tiempo de duración de los lanzamientos del 100%, 90%, 80%, 30% (pvalor <0,05). El 100% representa las últimas ventanas de tiempo antes del lanzamiento del balón. Los ejecutantes expertos muestran una mayor consistencia en la coordinación, sin embargo los sujetos novatos exhiben una mayor variabilidad en la coordinación en estos intervalos. Conclusiones: Los resultados sugieren que la tarea de lanzar tiros libres requiere una larga fijación visual al sitio de interés, que temporalmente es similar en sujetos con diferentes niveles de habilidad. El patrón de mayor reproducibilidad sugiere que la coordinación codo-muñeca es la conducta perceptivo-motora clave para alcanzar un rendimiento experto.

2021 ◽  
Author(s):  
Xiaoxiao Cai ◽  
Zidong Chen ◽  
Yanping Liu ◽  
Zitian Liu ◽  
Daming Deng ◽  
...  

Abstract Purpose: Eye movement in intermittent exotropia (IXT) patients is characterized by viability and uncertainty, however, conventional strabismus inspection methods cannot reflect these important qualities. Here, we sought to study the ocular motor behavior of IXT under different viewing conditions by eye tracker.Methods: Sixty-one IXT patients (33 males and 28 females) and 15 age-matched control participants were recruited for this study. An eye tracker equipped with a high-speed camera and MATLAB software was employed to monitor and record eye movement as well as eye position in included subjects with 3D shutter glasses at a normal reading distance (57 cm).Results: By using an eye tracker, our data showed that 90% of the included IXT patients lost their control and showed exotropia in 1.5±2.1s. The average deviation degree measured by the eye tracker was 32.9±11.5△, ranging from 6 to 50△, and reached its maximum deviation degree at 36.9±12.4△, with a mean time of 2±1.5s. Although a significant difference exists in the strabismus quantification between the prism test and the eye tracker, the test results obtained from these two methods were positively correlated. Moreover, by using the eye tracker, the fixation instability of IXT patients could be easily recorded and analyzed. In addition, the included IXT patients were divided into three types according to their ocular motor behavior as monitored by an eye tracker.Conclusion: Eye trackers could not only provide continuous, precise and effective strabismus assessments but also analyze ocular motor behavior over a period of time in IXT patients.


2020 ◽  
Vol 02 ◽  
Author(s):  
Laurel Stringer ◽  
Sarah Malley ◽  
Darrell M. Hutto ◽  
Jason A. Griggs ◽  
Susana M. Salazar Marocho

Background: The most common approach to remove yttria stabilized zirconia (YSZ) fixed-dental prostheses (FDPs) is by means of diamond burs attached to a high-speed handpiece. This process is time-consuming and destructive. The use of lasers over mechanical instrumentation for removal of FDPs can lead to efficient and predictable restoration retrievability. However, the heat produced might damage the tooth pulp (>42˚C). Objective: The purpose of this study was to determine the maximum temperature (T) reached during the use of different settings of the erbium, chromium:yttrium-scandium-gallium-garnet Er,Cr:YSGG laser through a YSZ ceramic. Methods: YSZ slices (1 mm thick) were assigned into 7 groups. For the control group, a diamond bur was used to cut a 1 mm groove into the YSZ slices. For the 6 experimental groups, the laser was operated at a constant combination of 33% water and 66% air during 30 s with two different power settings (W) at three frequencies (PPS), as follows (W/PPS): 2.5/20, 2.5/30, 2.5/45, 4.5/20, 4.5/30, 4.5/45. The T through the YSZ slice was recorded in degrees Celsius by using a digital thermometer with a K thermocouple. Results: The median T of the control group was 26.5˚C. The use of 4.5 W resulted in the median T (˚C) of 44.2 at 20 PPS, 53.3 at 30 PPS, and 58.9 at 45 PPS, while 2.5 W showed 34.6, 31.6, and 25.0 at 20, 30, and 45 PPS, respectively. KruskalWallis one-way ANOVA showed that within each power setting, the T was similar. The high power and lowest frequency (4.5/20) showed no significant difference from the 2.5 W settings and the control group. Conclusion: The lower power setting (2.5 W) is a potential method for the use of the Er,Cr:YSGG laser to debond YSZ structures. The higher power (4.5 W) with high frequencies (30 and 45 PPS) is unsuitable.


Author(s):  
Lucas Sousa Macedo ◽  
Renato Polese Rusig ◽  
Gustavo Bersani Silva ◽  
Alvaro Baik Cho ◽  
Teng Hsiang Wei ◽  
...  

BACKGROUND: Microsurgical flaps are widely used to treat complex traumatic wounds of upper and lower limbs. Few studies have evaluated whether the vascular changes in preoperative computed tomography angiography (CTA) influence the selection of recipient vessel and type of anastomosis and the microsurgical flaps outcomes including complications. OBJECTIVE: The aim of this study was to evaluate if preoperative CTA reduces the occurrence of major complications (revision of the anastomosis, partial or total flap failure, and amputation) of the flaps in upper and lower limb trauma, and to describe and analyze the vascular lesions of the group with CTA and its relationship with complications. METHODS: A retrospective cohort study was undertaken with all 121 consecutive patients submitted to microsurgical flaps for traumatic lower and upper limb, from 2014 to 2020. Patients were divided into two groups: patients with preoperative CTA (CTA+) and patients not submitted to CTA (CTA–). The presence of postoperative complications was assessed and, within CTA+, we also analyzed the number of patent arteries on CTA and described the arterial lesions. RESULTS: Of the 121 flaps evaluated (84 in the lower limb and 37 in the upper limb), 64 patients underwent preoperative CTA. In the CTA+ group, 56% of patients with free flaps for lower limb had complete occlusion of one artery. CTA+ patients had a higher rate of complications (p = 0.031), which may represent a selection bias as the most complex limb injuries and may have CTA indicated more frequently. The highest rate of complications was observed in chronic cases (p = 0.034). There was no statistically significant difference in complications in patients with preoperative vascular injury or the number of patent arteries. CONCLUSIONS: CTA should not be performed routinely, however, CTA may help in surgical planning, especially in complex cases of high-energy and chronic cases, since it provides information on the best recipient artery and the adequate level to perform the microanastomosis, outside the lesion area.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Song-Quan Ong ◽  
Hamdan Ahmad ◽  
Gomesh Nair ◽  
Pradeep Isawasan ◽  
Abdul Hafiz Ab Majid

AbstractClassification of Aedes aegypti (Linnaeus) and Aedes albopictus (Skuse) by humans remains challenging. We proposed a highly accessible method to develop a deep learning (DL) model and implement the model for mosquito image classification by using hardware that could regulate the development process. In particular, we constructed a dataset with 4120 images of Aedes mosquitoes that were older than 12 days old and had common morphological features that disappeared, and we illustrated how to set up supervised deep convolutional neural networks (DCNNs) with hyperparameter adjustment. The model application was first conducted by deploying the model externally in real time on three different generations of mosquitoes, and the accuracy was compared with human expert performance. Our results showed that both the learning rate and epochs significantly affected the accuracy, and the best-performing hyperparameters achieved an accuracy of more than 98% at classifying mosquitoes, which showed no significant difference from human-level performance. We demonstrated the feasibility of the method to construct a model with the DCNN when deployed externally on mosquitoes in real time.


Polymers ◽  
2021 ◽  
Vol 13 (10) ◽  
pp. 1595
Author(s):  
Asif Javed ◽  
Peter Rättö ◽  
Lars Järnström ◽  
Henrik Ullsten

One severe weakness of most biopolymers, in terms of their use as packaging materials, is their relatively high solubility in water. The addition of kraft lignin to starch coating formulations has been shown to reduce the water solubility of starch in dry coatings. However, lignin may also migrate into aqueous solutions. For this paper, kraft lignin isolated using the LignoBoost process was used in order to examine the effect of pH level on the solubility of lignin with and without ammonium zirconium carbonate (AZC). Machine-glazed (MG) paper was coated in a pilot coating machine, with the moving substrate at high speed, and laboratory-coated samples were used as a reference when measuring defects (number of pinholes). Kraft lignin became soluble in water at lower pH levels when starch was added to the solution, due to the interactions between starch and lignin. This made it possible to lower the pH of the coating solutions, resulting in increased water stability of the dry samples; that is, the migration of lignin to the model liquids decreased when the pH of the coating solutions was reduced. No significant difference was observed in the water vapor transmission rate (WVTR) between high and low pH for the pilot-coated samples. The addition of AZC to the formulation reduced the migration of lignin from the coatings to the model liquids and led to an increase in the water contact angle, but also increased the number of pinholes in the pilot-coated samples.


Author(s):  
O Kocar ◽  
H Livatyalı

An aluminized 22MnB5 (Boron) steel sheet, used for structural parts in the automotive industry, was subjected to press-hardening followed by austenitizing, both in a conventional furnace and via the conductive (electric resistance) heating method, an innovative technique based on the Joule’s principle for fast heating of the sheet metal. Conductive heating presents a number of advantages over the in-furnace heating method. These include a more efficient use of energy, as well as the requirement of less time and space for heating, thus lowering costs. After press-hardening was performed using both methods, the microstructural and mechanical characterizations of both specimens were examined for optical microscopy, hardness, tensile strength, and high-speed impact tests. The results showed that the press-hardening process transformed the ferritic–pearlitic microstructure in the as-received state into martensite after die quenching and caused a substantial increase in hardness and strength at the expense of ductility and impact toughness. On the other hand, no significant difference was observed in either the microstructure or mechanical properties with respect to the heating method used. The results obtained in the present investigation concur with the findings of current literature.


2014 ◽  
Vol 129 (S1) ◽  
pp. S45-S50 ◽  
Author(s):  
J H Kim ◽  
J Rimmer ◽  
N Mrad ◽  
S Ahmadzada ◽  
R J Harvey

AbstractObjective:This study investigated the effect of Betadine on ciliated human respiratory epithelial cells.Methods:Epithelial cells from human sinonasal mucosa were cultured at the air–liquid interface. The cultures were tested with Hanks' balanced salt solution containing 10 mM HEPES (control), 100 µM ATP (positive control), 5 per cent Betadine or 10 per cent Betadine (clinical dose). Ciliary beat frequency was analysed using a high-speed camera on a computer imaging system.Results:Undiluted 10 per cent Betadine (n = 6) decreased the proportion of actively beating cilia over 1 minute (p < 0.01). Ciliary beat frequency decreased from 11.15 ± 4.64 Hz to no detectable activity. The result was similar with 5 per cent Betadine (n = 7), with no significant difference compared with the 10 per cent solution findings.Conclusion:Betadine, at either 5 and 10 per cent, was ciliotoxic. Caution should be applied to the use of topical Betadine solution on the respiratory mucosal surface.


2001 ◽  
Vol 204 (24) ◽  
pp. 4345-4351
Author(s):  
Bruce A. Young ◽  
Krista Zahn

SUMMARY The functional morphology of venom injection in Crotalus atrox was explored using high-speed digital videography combined with direct recording of venom flow using perivascular flow probes. Although venom flow was variable, in most strikes the onset of venom flow was coincidental with fang penetration, and retrograde flow (venom suction) was observed prior to fang withdrawal. The duration of venom flow was consistently less than the duration of fang penetration. The occurrence of retrograde flow, ‘dry bites’ (which accounted for 35 % of the strikes) and unilateral strikes all support a hypothesis for venom pooling in the distal portion of the venom-delivery system. No significant difference in temporal or volumetric aspects of venom flow were found between defensive strikes directed at small and large rodents. With the species and size of target held constant, the duration of venom flow, maximum venom flow rate and total venom volume were all significantly lower in predatory than in defensive strikes.


Author(s):  
J. C. Heigel ◽  
B. M. Lane

This work presents high speed thermographic measurements of the melt pool length during single track laser scans on nickel alloy 625 substrates. Scans are made using a commercial laser powder bed fusion machine while measurements of the radiation from the surface are made using a high speed (1800 frames per second) infrared camera. The melt pool length measurement is based on the detection of the liquidus-solidus transition that is evident in the temperature profile. Seven different combinations of programmed laser power (49 W to 195 W) and scan speed (200 mm/s to 800 mm/s) are investigated and numerous replications using a variety of scan lengths (4 mm to 12 mm) are performed. Results show that the melt pool length reaches steady state within 2 mm of the start of each scan. Melt pool length increases with laser power, but its relationship with scan speed is less obvious because there is no significant difference between cases performed at the highest laser power of 195 W. Although keyholing appears to affect the anticipated trends in melt pool length, further research is required.


2018 ◽  
Vol 34 (5) ◽  
pp. 347-354
Author(s):  
Garrett Easson ◽  
Megan Laughlin ◽  
Hanna Jensen ◽  
Kevin Haney ◽  
Marc Girardot ◽  
...  

Objectives The purpose of this study is to test venous valve performance and identify differences between native tissue and replacement devices developed with traditional tissue treatment methods using a new in vitro model with synchronized hemodynamic parameters and high-speed valve image acquisition. Methods An in vitro model mimicking the venous circulation to test valve performance was developed using hydrostatic pressure driven flow. Fresh and glutaraldehyde-treated vein segments were placed in the setup and opening/closing of the valves was captured by a high-speed camera. Hemodynamic data were obtained using synchronized hardware and virtual instrumentation. Results Geometric orifice area and opening/closing time of the valves was evaluated at the same hemodynamic conditions. A reduction in geometric orifice area of 27.2  ± 14.8% (p < 0.05) was observed following glutaraldehyde fixation. No significant difference in opening/closing time following chemical fixation was observed. Conclusions The developed in vitro model was shown to be an effective method for measuring the performance of venous valves. The observed decrease in geometric orifice area following glutaraldehyde treatment indicates a decrease in flow through the valve, demonstrating the consequences of traditional tissue treatment methods.


Sign in / Sign up

Export Citation Format

Share Document