Comparison of the complete filtration method using an automated feces analyzer with three manual methods for stool examinations

Author(s):  
Peechana Aiadsakun ◽  
Wilaiwan Sriwimol ◽  
Nannapas Thongbun ◽  
Bancha Rui-on ◽  
Kulathida Thiparaksaphan ◽  
...  
1973 ◽  
Vol 12 (02) ◽  
pp. 102-107 ◽  
Author(s):  
D. J. Protti ◽  
Nancy Craven ◽  
A. Naimark ◽  
R. M. Cherniack

A previously described comprehensive respiratory information system (CRIS) has been changed to introduce new spirometric tests which are sensitive to minor abnormalities, revise on the basis of additional data the regression equations which define normal values to various parameters of pulmonary function and refine the system’s interpretation scheme. The beneficial effects of transferring the system from a large IBM 360/65 to a small CDC 1700 are presented. An analysis of the costs of processing routine pulmonary function studies reveals that a 40°/o saving is realized when a computer is used in comparison to the use of the usual manual methods.


1979 ◽  
Author(s):  
M Drummond ◽  
G Lowe ◽  
J Belch ◽  
C Forbes ◽  
J Barbenel

We investigated the reproducibility and validity of a simple method of measuring red cell deformability (filtration of whole blood through 5 µ sieves) and its relationship to haematocrit, blood viscosity, fibrinogen, white cell count, sex and smoking. The mean coefficient of variation in normals was 3. 7%. Tanned red cells showed marked loss of deformability. Blood filtration rate correlated with haematocrit (r = 0. 99 on dilution of samples, r = 0. 7 in 120 normals and patients). After correction for haematocrit, deformability correlated with high shear viscosity, but not low shear viscosity, fibrinogen or white cell count. In 60 normals there was no significant difference between males and females, or smokers and non-smokers, but in 11 smokers there was an acute fall in deformability after smoking 3 cigarettes (p<0. 05). Reduced deformability was found in acute myocardial infarction (n = 15, p<0. 01) and chronic peripheral arterial disease (n = 15, p<0. 01). The technique is reproducible, detects rigid cells and appears useful in the study of vascular disease.


Author(s):  
Bob Wettermann

Abstract As the pitch and package sizes of semiconductor devices have shrunk and their complexity has increased, the manual methods by which the packages can be re-bumped or reballed for failure analysis have not kept up with this miniaturization. There are some changes in the types of reballing preforms used in these manual methods along with solder excavation techniques required for packages with pitches as fine as 0.3mm. This paper will describe the shortcomings of the previous methods, explain the newer methods and materials and demonstrate their robustness through yield, mechanical solder joint strength and x-ray analysis.


2002 ◽  
Vol 2 (3) ◽  
pp. 131-138 ◽  
Author(s):  
D.L. Craig ◽  
H.J. Fallowfield ◽  
N.J. Cromar

A laboratory based microcosm study utilising intact non-sterile sediment cores was undertaken to determine the survival of the faecal indicator organisms Escherichia coli, Enterococcus faecium and somatic coliphage in both recreational coastal water and sediment. Overlying water was inoculated with the test organisms and incubated at 10°C, 20°C or 30°C. E. coli, enterococcus and coliphage were enumerated from the water column and sediment by the membrane filtration method, Enterolert (IDEXX Laboratories) and the double-agar overlay methods respectively on days 0, 1, 2, 7, 14 and 28 following inoculation. It was demonstrated that for all organisms, greater decay (k; d-1) occurred in the water column compared to sediment. Sediment characteristics were found to influence decay, with lowest decay rates observed in sediment consisting of high organic carbon content and small particle size. Decay of E. coli was significantly greater in both the water column and sediment compared with enterococcus and coliphage under all conditions. Decay of enterococcus was found to closely resemble that of coliphage decay. Survival of all organisms was inversely related to temperature, with greatest decay at 30°C. However, increased temperature had a less significant impact on survival of enterococcus and coliphage compared with E. coli. The importance of this study for estimating risk from recreational exposure is great if some pathogenic microorganisms behave similarly to the organisms tested in this study. In particular if survival rates of pathogens are similar to enterococcus and coliphage, then their ability to accumulate in coastal sediment may lead to an increased risk of exposure if these organisms are resuspended into the water column due to natural turbulence or human recreational activity.


1993 ◽  
Vol 27 (3-4) ◽  
pp. 267-270 ◽  
Author(s):  
M. T. Augoustinos ◽  
N. A. Grabow ◽  
B. Genthe ◽  
R. Kfir

A fluorogenic β-glucuronidase assay comprising membrane filtration followed by selective enumeration on m-FC agar at 44.5°C and further confirmation using tlie 4-metliylumbelliferyl-β-D-glucuronide (MUG) containing medium was evaluated for the detection of Escherichia coli in water. A total of 200 typical blue and non-typical blue colonies were isolated from sea and fresh water samples using initial selective enumeration on m-FC agar. Pure cultures of the selected colonies were further tested using the MUG assay and identified using the API 20E method. Of the colonies tested which were shown to be positive using the MUG assay 99.4% were Escherichia coli. The results of this study indicate the combination of the m-FC method followed by the MUG assay to be highly efficient for the selection and confirmation of E. coli from a wide range of environmental waters.


2019 ◽  
Vol 6 (1) ◽  
Author(s):  
MATHALA JULIET GUPTA ◽  
ASHISH M. PITRE ◽  
SUMATI CHAVAN PANDURNAG ◽  
SALONI SALIL VANJARI

This paper assessed the impact of the mechanization of the 8 tribal paddy farmers’ groups of Goa benefited in the year 2011 through the Tribal sub-plan program of ICAR-CCARI through results of surveys conducted in 2012 and 2015. Shift to mechanization among beneficiaries was significant in power tillers (64-100%) but less in power reapers(0-91%). Also significant saving in manpower (Power tillers:33.3% to 60%, power reapers: 33.3% to 83.3%), , time (field capacity increased (power tillers : 41.7% to141%, power reapers :58.1% to 912.8%) and cost(power tillers :44.7% to 59.1%, power reapers : 57.8% to 82.9%) was reportedthrough the use of equipment as compared to desi plough or manual methods of harvesting. Some constraints like lack of access roads and training in use and maintenance of the equipment were reported by the beneficiary farmers.


2011 ◽  
Vol 295-297 ◽  
pp. 751-759 ◽  
Author(s):  
Hua Shen ◽  
Wei Dong Yang ◽  
He Liang ◽  
Guang Chun Yao

The presence of Fe and harmful effects on mechanical properties of pure aluminum and aluminum alloys are introduced. Several purification methods are reviewed, but all of them are of definite limitations. It is effective that precipitation method, filtration method and centrifugal division method are integrated.


Animals ◽  
2021 ◽  
Vol 11 (6) ◽  
pp. 1478
Author(s):  
Lorenzo G. T. M. Segabinazzi ◽  
Giorgia Podico ◽  
Michael F. Rosser ◽  
Som G. Nanjappa ◽  
Marco A. Alvarenga ◽  
...  

In light of PRP’s increasing popularity in veterinary practice, this study aimed to compare three manual methods to prepare and cool equine PRP. The blood of 18 clinically healthy mares was collected via venipuncture in a blood transfusion bag (method 1), blood tubes (method 2), and a syringe (method 3). In method 1, samples were double centrifuged; method 2 involved one centrifugation, and in method 3 the syringe was kept in an upright position to sediment for 4 h. After processing with three methods, PRP and platelet-poor plasma (PPP) were extracted and assessed for red (RBC) and white blood cell counts (WBC), platelet counts, and viability. In a subset of mares (n = 6), samples were processed with the three methods, and PRP was evaluated at 6 and 24 h postcooling at 5 °C. Method 1 resulted in the highest and method 3 in the lowest platelet concentration (p < 0.05), and the latter also had greater contamination with WBC than the others (p < 0.001). Platelet viability was similar across treatments (p > 0.05). Cooling for 24 h did not affect platelet counts in all methods (p > 0.05); however, platelet viability was reduced after cooling PRP produced by method 3 (p = 0.04), and agglutination increased over time in all methods (p < 0.001). The three methods increased (1.8–5.6-fold) platelet concentration in PRP compared to whole blood without compromising platelet viability. In conclusion, all three methods concentrated platelets and while cooling affected their viability. It remains unknown whether the different methods and cooling would affect PRP’s clinical efficacy.


Symmetry ◽  
2021 ◽  
Vol 13 (4) ◽  
pp. 717
Author(s):  
Mariia Nazarkevych ◽  
Natalia Kryvinska ◽  
Yaroslav Voznyi

This article presents a new method of image filtering based on a new kind of image processing transformation, particularly the wavelet-Ateb–Gabor transformation, that is a wider basis for Gabor functions. Ateb functions are symmetric functions. The developed type of filtering makes it possible to perform image transformation and to obtain better biometric image recognition results than traditional filters allow. These results are possible due to the construction of various forms and sizes of the curves of the developed functions. Further, the wavelet transformation of Gabor filtering is investigated, and the time spent by the system on the operation is substantiated. The filtration is based on the images taken from NIST Special Database 302, that is publicly available. The reliability of the proposed method of wavelet-Ateb–Gabor filtering is proved by calculating and comparing the values of peak signal-to-noise ratio (PSNR) and mean square error (MSE) between two biometric images, one of which is filtered by the developed filtration method, and the other by the Gabor filter. The time characteristics of this filtering process are studied as well.


2021 ◽  
pp. 159101992110091
Author(s):  
Ansaar T Rai ◽  
Ryan G Brotman ◽  
Gerald R Hobbs ◽  
SoHyun Boo

Background Accurate aneurysm measurements are important for selecting the WEB device. The objective was to validate a cloud-based platform, SurgicalPreview (SP) against manual measurements for aneurysm analysis. Methods Two sets of measurements each for SP and manual methods were obtained for 40 aneurysms. Reliability and agreement were assessed with intra-class correlation coefficient (ICC) and Bland-Altman plots respectively. Kappa coefficient was used to assess agreement for predicting WEB size. Results There was good reliability for repeat SP measurements: aneurysm diameter (ICC-1, 95%CI 0.98–1), height (ICC-1, 95%CI 0.99–1) and neck diameter (ICC-0.96, 95%CI 0.93–0.98). There was good reliability for the two manual diameter (ICC-0.97, 95%CI 0.9–0.97) and height (ICC-0.93, 95%CI 0.87–0.96) measurements and moderate for neck diameter (ICC-0.76, 95%CI 0.54–0.87). There was greater agreement for SP versus manual repeat measurements on Bland-Altman plots. Reliability between the SP and manual methods was good for aneurysm diameter (ICC-0.98, 95%CI 0.95–1) and height (ICC-0.96, 95%CI-0.93–0.98) and moderate for neck. (ICC-0.6, 95%CI -0.22–0.87). The Bland-Altman plots confirmed better agreement between the two methods for the aneurysm diameter and height than the neck. There was strong agreement between the methods for predicting the WEB diameter (Kappa-0.84, 95%CI 0.71–0.97) and moderate for predicting WEB height (Kappa-0.66, 95%CI 0.43–0.89). There was moderate agreement for predicted versus deployed WEB diameter: SP (Kappa-0.56, 95%CI 0.38–0.74), Manual (Kappa-0.53, 95%CI 0.34–0.71). Conclusion The SurgicalPreview® had greater agreement for repeat measurements. There was good reliability between the two methods for predicting WEB diameter and height and moderate agreement between predicted versus deployed WEB diameter.


Sign in / Sign up

Export Citation Format

Share Document