SYNCHRONOUS MEASUREMENTS OF FINGER SURFACE TEMPERATURE FROM THREE DIFFERENT KINDS OF TEMPERATURE SENSORS

2013 ◽  
Vol 37 (3) ◽  
pp. 1035-1041 ◽  
Author(s):  
Fong-Lin Jang ◽  
Chyun-Chau Lin

The aim of this study was to explore new valid sensors for temperature biofeedback. Three kinds of temperature sensors (thermography imaging, thermistor, and infrared thermopile) were employed to record participants’ finger surface temperatures simultaneously. The skin temperature readings resulted in strong correlations between sensors. These results suggested that contact and non-contact temperature sensors all had good synchronous temperature covariance in measuring finger surface temperature.

2017 ◽  
Author(s):  
Alden C. Adolph ◽  
Mary R. Albert ◽  
Dorothy K. Hall

Abstract. As rapid warming of the Arctic occurs, it is imperative that climate indicators such as temperature be monitored over large areas to understand and predict the effects of climate changes. Temperatures are traditionally tracked using in situ 2 m air temperatures, but in remote locations where few ground-based measurements exist, such as on the Greenland Ice Sheet, temperatures over large areas are assessed using remote sensing techniques. Because of the presence of surface-based temperature inversions in ice-covered areas, differences between 2 m air temperature and the temperature of the actual snow surface (referred to as skin temperature) can be significant and are particularly relevant when considering validation and application of remote sensing temperature data. We present results from a field campaign extending from 8 June through 18 July 2015, near Summit Station in Greenland to study surface temperature using the following measurements: skin temperature measured by an infrared (IR) sensor, thermochrons, and thermocouples; 2 m air temperature measured by a NOAA meteorological station; and a MODerate-resolution Imaging Spectroradiometer (MODIS) surface temperature product. Our data indicate that 2 m air temperature is often significantly higher than snow skin temperature measured in-situ, and this finding may account for apparent biases in previous surface temperature studies of MODIS products that used 2 m air temperature for validation. This inversion is present during summer months when incoming solar radiation and wind speed are both low. As compared to our in-situ IR skin temperature measurements, after additional cloud masking, the MOD/MYD11 Collection 6 surface-temperature standard product has an RMSE of 1.0 °C, spanning a range of temperatures from −35 °C to −5 °C. For our study area and time series, MODIS surface temperature products agree with skin surface temperatures better than previous studies indicated, especially at temperatures below −20 °C where other studies found a significant cold bias. The apparent cold bias present in others’ comparison of 2 m air temperature and MODIS surface temperature is perhaps a result of the near-surface temperature inversion that our data demonstrate. Further investigation of how in-situ IR skin temperatures compare to MODIS surface temperature at lower temperatures (below −35 °C) is warranted to determine if this cold bias does indeed exist.


2013 ◽  
Vol 284-287 ◽  
pp. 1559-1563
Author(s):  
Fong Lin Jang ◽  
Chyun Chau Lin

Temperature biofeedback has been used in behavioral medicine for more than three decades. Traditional temperature biofeedback uses the contact sensor of a thermistor to measure one’s finger surface temperature. The goal of this study is to discover new valid sensors for temperature biofeedback. Sixteen healthy young adult volunteers (23.1±2.0 years old) practiced cognitive imagery muscle relaxation with three kinds of temperature sensors (thermography imaging, thermistor, and infrared thermopile) to measure their finger surfaces simultaneously. The temperature readings from different sensors were synchronically videotaped and converged to video files for analyses. The data were selected every half a minute from a fixed section of the muscle relaxation procedure to show the outline of the temperature variation. Twenty-eight means of skin temperature measurements from each sensor resulted in overall correlation coefficients of R=0.98 (p<0.001) between the thermistor and thermography imaging sensors, R=0.95 (p<0.001) between thermography imaging and infrared thermopile sensors, and R=0.96 (p<0.001) between thermistor and infrared thermopile sensors. These results suggest that contact and non-contact temperature sensors could demonstrate good synchronous temperature covariance in measuring finger surface temperature. This study also proposes specific setups for instrumentation of finger surface temperature monitoring.


2019 ◽  
pp. 9-13
Author(s):  
V.Ya. Mendeleyev ◽  
V.A. Petrov ◽  
A.V. Yashin ◽  
A.I. Vangonen ◽  
O.K. Taganov

Determining the surface temperature of materials with unknown emissivity is studied. A method for determining the surface temperature using a standard sample of average spectral normal emissivity in the wavelength range of 1,65–1,80 μm and an industrially produced Metis M322 pyrometer operating in the same wavelength range. The surface temperature of studied samples of the composite material and platinum was determined experimentally from the temperature of a standard sample located on the studied surfaces. The relative error in determining the surface temperature of the studied materials, introduced by the proposed method, was calculated taking into account the temperatures of the platinum and the composite material, determined from the temperature of the standard sample located on the studied surfaces, and from the temperature of the studied surfaces in the absence of the standard sample. The relative errors thus obtained did not exceed 1,7 % for the composite material and 0,5% for the platinum at surface temperatures of about 973 K. It was also found that: the inaccuracy of a priori data on the emissivity of the standard sample in the range (–0,01; 0,01) relative to the average emissivity increases the relative error in determining the temperature of the composite material by 0,68 %, and the installation of a standard sample on the studied materials leads to temperature changes on the periphery of the surface not exceeding 0,47 % for composite material and 0,05 % for platinum.


2018 ◽  
Vol 14 (6) ◽  
pp. 901-922 ◽  
Author(s):  
Mari F. Jensen ◽  
Aleksi Nummelin ◽  
Søren B. Nielsen ◽  
Henrik Sadatzki ◽  
Evangeline Sessford ◽  
...  

Abstract. Here, we establish a spatiotemporal evolution of the sea-surface temperatures in the North Atlantic over Dansgaard–Oeschger (DO) events 5–8 (approximately 30–40 kyr) using the proxy surrogate reconstruction method. Proxy data suggest a large variability in North Atlantic sea-surface temperatures during the DO events of the last glacial period. However, proxy data availability is limited and cannot provide a full spatial picture of the oceanic changes. Therefore, we combine fully coupled, general circulation model simulations with planktic foraminifera based sea-surface temperature reconstructions to obtain a broader spatial picture of the ocean state during DO events 5–8. The resulting spatial sea-surface temperature patterns agree over a number of different general circulation models and simulations. We find that sea-surface temperature variability over the DO events is characterized by colder conditions in the subpolar North Atlantic during stadials than during interstadials, and the variability is linked to changes in the Atlantic Meridional Overturning circulation and in the sea-ice cover. Forced simulations are needed to capture the strength of the temperature variability and to reconstruct the variability in other climatic records not directly linked to the sea-surface temperature reconstructions. This is the first time the proxy surrogate reconstruction method has been applied to oceanic variability during MIS3. Our results remain robust, even when age uncertainties of proxy data, the number of available temperature reconstructions, and different climate models are considered. However, we also highlight shortcomings of the methodology that should be addressed in future implementations.


Foods ◽  
2021 ◽  
Vol 10 (5) ◽  
pp. 1107
Author(s):  
Yingxia He ◽  
Shuang Chen ◽  
Ke Tang ◽  
Yan Xu ◽  
Xiaowei Yu

Pungency is a crucial sensory feature that influences consumers’ appreciation and preferences toward alcoholic beverages. However, the quantitation of pungency is challenging to achieve using sensory analysis because of persistence, accumulation, and desensitization to the pungency perception. This study aimed to design a novel pungency evaluation method based on the measurement of tongue surface temperature. An infrared thermal (IRT) imager technique for measuring tongue surface temperature was established. To validate its feasibility, the IRT technique was used to measure tongue surface temperatures after the tongue was stimulated by (1) water and Baijiu, (2) different concentrations of ethanol aqueous solution (10, 20, 30, 40, and 50%, v/v), (3) ethanol aqueous solution and Baijiu samples with the same ethanol content, and (4) 26 Baijiu samples with different pungency level. For all cases, tongue surface temperatures showed large differences as a result of the different stimulation. The results showed that the tongue surface temperature correlated with the pungency intensity obtained by the sensory analysis. The relationship between tongue surface temperature and pungency intensity was established by multiple linear regression analysis. The IRT technique was able to be a useful support tool to quantitatively predict the pungency of alcoholic beverages, based on the measurement of tongue surface temperature.


1988 ◽  
Vol 74 (3) ◽  
pp. 181-186
Author(s):  
S. P. L. Travis

AbstractThe surface temperature of eight Royal Marine recruits was monitored in the field during Autumn training on Dartmoor (minimum air temperature 4.5°C). The lowest skin temperature recorded was 6.1°C. One subject experienced a toe temperature below 10° for 5.5 hours and below 15°C for 12.6 hours during a 24 hour recording period. Ambient temperature and inactivity during exposure to cold were the main factors associated with low toe temperatures but individual responses varied widely.


2021 ◽  
Author(s):  
Laura Namisnak ◽  
Sepideh Khoshnevis ◽  
Kenneth R. Diller

Abstract Various medical procedures are accomplished by manipulating skin temperature in a nonuniform pattern. Skin temperature monitoring is essential to assess conformance to protocol specifications and to prevent thermal injury. Existing solutions for skin temperature monitoring include single point sensors, such as thermocouples, and two-dimensional methods of sensing surface temperature, such as infrared thermography, and wearable technology. Single point sensors cannot detect the average temperature and consequently their measurements cannot be representative of average surface temperature in a nonuniform temperature field. Infrared thermography requires optical access, and wearable sensors may require complex manufacturing processes and impede the heat exchange with a source by introducing a layer of insulation. Our solution is a two-dimensional resistance temperature detector (2D RTD) created by knitting copper magnet wire into custom shapes. The 2D RTDs were calibrated, compared to one-dimensional sensors and wearable sensors, and analyzed for hysteresis, repeatability, and surface area conformation. Resistance and temperature were correlated with an R2 of 0.99. The 2D RTD proved to be a superior device for measuring average skin temperature exposed to a nonuniform temperature boundary in the absence of optical access such as when a full body thermal control garment is worn.


2011 ◽  
Vol 250-253 ◽  
pp. 536-539
Author(s):  
Pei Wang ◽  
Wen Yan Lv ◽  
Zhi Yong Wei ◽  
Xia Zhen Zhang ◽  
Lian Liu ◽  
...  

This paper presented the results of a comparative study aiming to investigate the effect of reflective coatings on lowering surface temperatures of matrix. Moreover, the important factors of the amount and the color of colored hollow-ceramic micro sphere were discussed. It was demonstrated that the use of reflective coatings could reduce a white surface temperature by 6.5 °C compared to a sample. The temperature difference became to reduce while the color of coatings turned to dark from the white to the yellow.


Author(s):  
Jeong Tae Ok ◽  
Sunggook Park

The influence of ratchet depth on the motion of Leidenfrost water drop was investigated as a continuous effort to reveal the driving mechanism. Continuous directional rebounding behavior of the drop was observed only at below 200°C on both micro ratchets with two different depth-to-period aspect ratios (1:5 and 1:10) and sharp ridges. Overall, the shallow ratchets generated more efficient drop mobility in the entire surface temperature range of 193–299°C due to the increased area between the bottom of the drop and the ratchet surface, caused by the geometrical benefit. However, the depth effect was only critical at relatively lower surface temperatures.


2015 ◽  
Vol 12 (8) ◽  
pp. 7665-7687 ◽  
Author(s):  
C. L. Pérez Díaz ◽  
T. Lakhankar ◽  
P. Romanov ◽  
J. Muñoz ◽  
R. Khanbilvardi ◽  
...  

Abstract. Land Surface Temperature (LST) is a key variable (commonly studied to understand the hydrological cycle) that helps drive the energy balance and water exchange between the Earth's surface and its atmosphere. One observable constituent of much importance in the land surface water balance model is snow. Snow cover plays a critical role in the regional to global scale hydrological cycle because rain-on-snow with warm air temperatures accelerates rapid snow-melt, which is responsible for the majority of the spring floods. Accurate information on near-surface air temperature (T-air) and snow skin temperature (T-skin) helps us comprehend the energy and water balances in the Earth's hydrological cycle. T-skin is critical in estimating latent and sensible heat fluxes over snow covered areas because incoming and outgoing radiation fluxes from the snow mass and the air temperature above make it different from the average snowpack temperature. This study investigates the correlation between MODerate resolution Imaging Spectroradiometer (MODIS) LST data and observed T-air and T-skin data from NOAA-CREST-Snow Analysis and Field Experiment (CREST-SAFE) for the winters of 2013 and 2014. LST satellite validation is imperative because high-latitude regions are significantly affected by climate warming and there is a need to aid existing meteorological station networks with the spatially continuous measurements provided by satellites. Results indicate that near-surface air temperature correlates better than snow skin temperature with MODIS LST data. Additional findings show that there is a negative trend demonstrating that the air minus snow skin temperature difference is inversely proportional to cloud cover. To a lesser extent, it will be examined whether the surface properties at the site are representative for the LST properties within the instrument field of view.


Sign in / Sign up

Export Citation Format

Share Document