Dependency of Advanced Oxidation Performance on the Contaminated Water Feed Mode for Ozonation Combined with Electrolysis Using a Two-compartment Electrolytic Flow Cell

Author(s):  
Naoyuki Kishimoto

AbstractThe effect of the contaminated water feed mode on advanced oxidation performance, for a combined system, using ozonation with electrolysis (ozone-electrolysis) in a two-compartment electrolytic flow cell, was discussed for ozone injection to the cathodic compartment of the cell. When ozone-electrolysis was applied, removal of the chemical oxygen demand (COD) proceeded in the cathodic compartment. The overall COD removal rate increased with the increase in current density for direct feed of contaminated water to the anodic compartment (DFA mode). However, the overall COD removal rate decreased at high current density for direct feed to the cathodic compartment (DFC mode), although the overall performance for the DFC mode was better than the DFA mode. The difference in the dependency of the performance on current density was determined to be due to the difference in the advanced oxidation mechanisms for each mode.

2013 ◽  
Vol 295-298 ◽  
pp. 1168-1172
Author(s):  
Jing Shi Li ◽  
Xiao Jun Wang ◽  
Rui Deng ◽  
Zhi Hua Pang

Chromaticity of cigarette industry wastewater increase when treating by aerobic due to large quantities of lignin, nicotine and carbohydrate. Ozone and advance oxidation are proposed for degradation and decoloration of cigarette wastewater that processed by aerobic. The result shows that ozone process has its advantage of high decoloration rate, simple operation and low operation cost. Optimum parameters of ozone process are ozone dosage of 37.65mg/L, reaction time of 15min, reaction pH of 7.0-9.0. The COD removal rate is 38.3% when the decoloration rate is 57.5%. Operation cost of ozone process is 0.4 yuan/m3.


1998 ◽  
Vol 38 (8-9) ◽  
pp. 213-221 ◽  
Author(s):  
Mohamed F. Hamoda ◽  
Ibrahim A. Al-Ghusain

Performance data from a pilot-plant employing the four-stage aerated submerged fixed film (ASFF) process treating domestic wastewater were analyzed to examine the organic removal rates. The process has shown high BOD removal efficiencies (> 90%) over a wide range of hydraulic loading rates (0.04 to 0.68 m3/m2·d). It could also cope with high hydraulic and organic loadings with minimal loss in efficiency due to the large amount of immobilized biomass attained. The organic (BOD and COD) removal rate was influenced by the hydraulic loadings applied, but organic removal rates of up to 104 kg BOD/ m2·d were obtained at a hydraulic loading rate of 0.68 m3/m2·d. A Semi-empirical model for the bio-oxidation of organics in the ASFF process has been formulated and rate constants were calculated based on statistical analysis of pilot-plant data. The relationships obtained are very useful for analyzing the design and performance of the ASFF process and a variety of attached growth processes.


Author(s):  
Zahia Benredjem ◽  
Karima Barbari ◽  
Imene Chaabna ◽  
Samia Saaidia ◽  
Abdelhak Djemel ◽  
...  

Abstract The Advanced Oxidation Processes (AOPs) are promising environmentally friendly technologies for the treatment of wastewater containing organic pollutants in general and particularly dyes. The aim of this work is to determine which of the AOP processes based on the Fenton reaction is more effective in degrading the methyl orange (MO) dye. The comparative study of the Fenton, photo-Fenton (PF) and electro-Fenton (EF) processes has shown that electro-Fenton is the most efficient method for oxidizing Methyl Orange. The evolution of organic matter degradation was followed by absorbance (discoloration) and COD (mineralization) measurements. The kinetics of the MO degradation by the electro-Fenton process is very rapid and the OM degradation rate reached 90.87% after 5 min. The influence of some parameters such as the concentration of the catalyst (Fe (II)), the concentration of MO, the current density, the nature and the concentration of supporting electrolyte was investigated. The results showed that the degradation rate increases with the increase in the applied current density and the concentration of the supporting electrolyte. The study of the concentration effect on the rate degradation revealed optimal values for the concentrations 2.10−5 M and 75 mg L−1 of Fe (II) and MO respectively.


Author(s):  
Devi Buehler ◽  
Nadine Antenen ◽  
Matthias Frei ◽  
Christoph Koller ◽  
Diederik P. L. Rousseau ◽  
...  

AbstractIn the scope of this study, a pilot facility for the recycling of laundry effluent was developed and tested. With the aim to enable nearly complete energy and water self-sufficiency, the system is powered by a photovoltaic plant with second-life batteries, treats the wastewater within the unit and constantly reuses the treated wastewater for washing in a closed cycle. The technology for wastewater treatment is based on a low-tech approach consisting of a physical/mechanical pre-treatment and biological treatment in trickling filter columns. The treatment process is operated in batch mode for a capacity of five washing cycles per day. During five weeks of operation water quality, energy consumption and production, water losses and washing performance were monitored. The system recovered 69% of the used water for the washing machine while treating the wastewater to the necessary water quality levels. The average COD removal rate per cycle was 92%. Energy analysis was based on modelled data of the monitored energy consumption. With the current set-up, an internal consumption rate of 80% and self-sufficiency of 30% were modelled. Future developments aim at increasing water and energy self-sufficiency and optimizing the water treatment efficiency.


2020 ◽  
Vol 13 (1) ◽  
pp. 126
Author(s):  
Guozhen Zhang ◽  
Xingxing Huang ◽  
Jinye Ma ◽  
Fuping Wu ◽  
Tianhong Zhou

Electrochemical oxidation technology is an effective technique to treat high-concentration wastewater, which can directly oxidize refractory pollutants into simple inorganic compounds such as H2O and CO2. In this work, two-dimensionally stable anodes, Ti/RuO2-IrO2-SnO2, have been developed in order to degrade organic pollutants from pharmaceutical wastewater. Characterization by scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), and X-ray diffraction (XRD) showed that the oxide coating was successfully fabricated on the Ti plate surface. Electrocatalytic oxidation conditions of high concentration pharmaceutical wastewater was discussed and optimized, and the best results showed that the COD removal rate was 95.92% with the energy consumption was 58.09 kW·h/kgCOD under the electrode distance of 3 cm, current density of 8 mA/cm2, initial pH of 2, and air flow of 18 L/min.


Water ◽  
2021 ◽  
Vol 13 (2) ◽  
pp. 156
Author(s):  
Manjing Lu ◽  
Jiaqi Wang ◽  
Yuzhong Wang ◽  
Zhengguang He

Chemical synthetic pharmaceutical wastewater has characteristics of high concentration, high toxicity and poor biodegradability, so it is difficult to directly biodegrade. We used acid modified attapulgite (ATP) supported Fe-Mn-Cu polymetallic oxide as catalyst for multi-phase Fenton-like ultraviolet photocatalytic oxidation (photo-Fenton) treatment with actual chemical synthetic pharmaceutical wastewater as the treatment object. The results showed that at the initial pH of 2.0, light distance of 20 cm, and catalyst dosage and hydrogen peroxide concentration of 10.0 g/L and 0.5 mol/L respectively, the COD removal rate of wastewater reached 65% and BOD5/COD increased to 0.387 when the reaction lasted for 180 min. The results of gas chromatography-mass spectrometry (GC-MS) indicated that Fenton-like reaction with Fe-Mn-Cu@ATP had good catalytic potential and significant synergistic effect, and could remove almost all heterocycle compounds well. 3D-EEM (3D electron microscope) fluorescence spectra showed that the fluorescence intensity decreased significantly during catalytic degradation, and the UV humus-like and fulvic acid were effectively removed. The degradation efficiency of the nanocomposite only decreased by 5.8% after repeated use for 6 cycles. It seems appropriate to use this process as a pre-treatment for actual pharmaceutical wastewater to facilitate further biological treatment.


Water ◽  
2020 ◽  
Vol 12 (6) ◽  
pp. 1686 ◽  
Author(s):  
Carolin Heim ◽  
Mohamad Rajab ◽  
Giorgia Greco ◽  
Sylvia Grosse ◽  
Jörg E. Drewes ◽  
...  

The focus of this study was to investigate the efficacy of applying boron-doped diamond (BDD) electrodes in an electrochemical advanced oxidation process, for the removal of the target compound diclofenac (DCF) in different water matrices. The reduction of DCF, and at the same time the formation of transformation products (TPs) and inorganic by-products, was investigated as a function of electrode settings and the duration of treatment. Kinetic assessments of DCF and possible TPs derived from data from the literature were performed, based on a serial chromatographic separation with reversed-phase liquid chromatographyfollowed by hydophilic interaction liquid chromatography (RPLC-HILIC system) coupled to ESI-TOF mass spectrometry. The application of the BDD electrode resulted in the complete removal of DCF in deionized water, drinking water and wastewater effluents spiked with DCF. As a function of the applied current density, a variety of TPs appeared, including early stage products, structures after ring opening and highly oxidized small molecules. Both the complexity of the water matrix and the electrode settings had a noticeable influence on the treatment process’s efficacy. In order to achieve effective removal of the target compound under economic conditions, and at the same time minimize by-product formation, it is recommended to operate the electrode at a moderate current density and reduce the extent of the treatment.


2012 ◽  
Vol 518-523 ◽  
pp. 2745-2748
Author(s):  
Ling Yan Ren ◽  
Gang Xu

The paper adopted Coagulation-Fenton Oxidation Method on treating the wastewater of 6-nitro-1,2 diazonium oxygroup naphthalene-4-sulfoacid production process (i.e. 6-nitry wastewater), introduced the treatment effect of the combined technology used on 6-nitry wastewater, and studied the factors influencing the treatment effect, to determine the reasonable parameters of the technology on treating 6-nitry wastewater. The results showed that Using polyaluminium chloride (mass fraction 2%) as flocculant for treating 6-nitry wastewater, the COD removal rate reached up to 48.7%; Making Fenton reagent oxidation treatment on coagulation yielding water, under the best conditions for solution acidity controlled at pH3 or so, in the 100 mL wastewater, 30% hydrogen peroxide was 5.0 mL, 0.5 mol/L ferrous sulfate solution was 4.0 mL, reaction time was 60 min, the COD removal rate could reach 98% or more.


2013 ◽  
Vol 726-731 ◽  
pp. 2316-2319
Author(s):  
Hai Xia Duan

TNT-RDX wastewater is hard to biodegrade and highly toxic. The self-made reactor was used to degrade the wastewater, spray and the conditions of droplet diameter, number of nozzle, spray height were clearly observed. The results show that the average COD removal rate of TNT-RDX wastewater was 69.6%.The spray conditions can improve the dispersion of the wastewater and increase the use of the residual ozone in gas phase. Keywords: Spray; TNT-RDX wastewater; ozone; UV; GAC


2018 ◽  
Vol 29 (10) ◽  
pp. 1850093
Author(s):  
ShengJie Qiang ◽  
Bin Jia ◽  
QingXia Huang

The asymmetric simple exclusion process (ASEP) is a paradigmatic model for nonequilibrium systems and has been used in many applications. Airplane boarding provides another interesting example where this framework can be applied. We propose a simple model for boarding process, in which a particle moves along a one-dimensional aisle after being injected, and finally is removed at a reserved site. Different from the typical ASEP model, particles are removed in a disorderly or a parallel way. Detailed calculations and discussions of some related characteristics, such as mean boarding time and parallelism indicator, are provided based on Monte-Carlo simulations. Results show that three phases exist in the boarding process: free-flow, jamming and maximum current. Transitions between these phases are governed by the difference between the injection and removal rate. Further analysis shows how the scaling behavior depends on the system size and the boarding conditions. Those results emphasize the importance of utilizing the whole length of the aisle to reduce the boarding time when designing an efficient boarding strategy.


Sign in / Sign up

Export Citation Format

Share Document