scholarly journals Application of effective microorganisms technology on dairy wastewater treatment for irrigation purposes

2021 ◽  
Vol 8 (4) ◽  
pp. 2917-2923
Author(s):  
Mohamed Nabil Ali ◽  
Tahani F Youssef ◽  
Marwa M Aly ◽  
Abdelrahman G Abuzaid

Due to the massive amounts of freshwater consumed in dairy industries, as a result, thousands of liters of wastewater were produced as one liter of milk produces 10 liters of wastewater which represents a major threat to the surrounding environment and aquatic life. The application of a promising technology called “effective microorganism (EM)” was the key solution due to its low operating cost, low technology, and eco-friendly condition. Three different effective microorganisms were used, such as Bacillus bacteria (EM1), Staphylococcus bacteria (EM2), and EM stoste + Molasses (EM3). EM1 and EM2 were isolated from the dairy wastewater by using streaking for isolation on an agar plate process, while EM3 was prepared by mixing 12 % EM stoste, 6% molasses, and 82% distilled water. A laboratory pilot consists of aeration and final settling tanks, both tanks followed by an activated carbon filter. Four trials were performed, the first trial was without any EM, the second trial was adding EM1 with a dose of 50 ml to the aeration tank, the third trial was EM2 with a dose of 50 ml to the aeration tank, finally adding EM3 with a dose of 30 ml to the aeration tank. Results showed that using Bacillus bacteria (EM1) was the most effective trial as it was effective in reducing TSS (total suspended solids), BOD (biological oxygen demand), COD (chemical oxygen demand), TN (total nitrogen), and TP (total phosphorous) concentrations by removal efficiency of 93%, 96.2%, 95.9%, 94%, and 64%, respectively which were below the limitations of the Egyptian code for reuse for irrigation purposes.

2020 ◽  
Vol 26 (10) ◽  
pp. 66-79
Author(s):  
Marwa M. Ali ◽  
Nawar Omran Ali ◽  
Mahdi Shanshal Jaafar

Greywater is a possible water source that can be improved for meeting the quality required for irrigation. Treatment of greywater can range from uncomplicated coarse filtration to advanced biological treatment. This article presents a simple design of a small scale greywater treatment plant, which is a series of physical and natural processes including screening, aeration, sedimentation, and filtration using granular activated carbon filter and differentiates its performance with sand filter. The performance of these units with the dual filter media of (activated carbon with sand) in treatment of greywater from Iraqi house in Baghdad city during 2019 and that collected from several points including washbasins, kitchen sink, bathrooms, and laundry, was recorded in terms of removal efficiency of particular pollutants like Turbidity 94%, chemical oxygen demand (COD) 93%, and oil 91%. Dual filter was the most effective filter for decreasing these pollutants, while sand indicates the lowest removal efficiency. In general, granular activated carbon media seemed to be the most proper medium to improve greywater quality for reaching the quality of irrigation within the terms of organic matter decrease. Accordingly, this technology may be reliable for greywater treatment in a residential area.


1999 ◽  
Vol 40 (3) ◽  
pp. 57-65 ◽  
Author(s):  
Martin M. Karpiscak ◽  
Robert J. Freitas ◽  
Charles P. Gerba ◽  
Luis R. Sanchez ◽  
Eylon Shamir

An integrated wastewater treatment facility, consisting of upper (solids separators, anaerobic lagoons, and aerobic ponds) and lower (wetland cells) subsystems, has been built to replace the lagoon at a dairy in Arizona, USA. The collection sump of the new waste treatment facility collects all dairy wastewater outflow. Wastewater is then pumped to solids separators, and flows by gravity to anaerobic ponds and aerobic ponds. The upper subsystem is expected to treat the water sufficiently so that the wetland cells may achieve further pollutant reductions. The lower subsystem, comprised of 8 surface wetland cells with an approximate surface area of 5,000 m2, receives outflow from the ponds. The cells are planted with cattail (Typha domingensis), soft-stem bulrush (Scirpus validus), and reed (Phragmites australis). After treatment is completed via the lagoons and ponds followed by the wetland cells, the wastewater can be reused to flush barns or to irrigate crops. Performance of the overall system is evaluated by measuring physical, chemical and biological parameters in water samples taken from selected locations along the treatment system. Chemical parameters studied include biochemical oxygen demand, pH, total suspended solids, nitrogen species. Biological monitoring included coliforms (total and fecal) and Listeria monocytogenes.


2021 ◽  
pp. 107815522110306
Author(s):  
Galit Levin ◽  
Paul JM Sessink

Purpose The purpose of this study was to test the efficacy of ChemfortTM, an air filtration closed-system drug transfer device to prevent release of chemotherapy drug vapors and aerosols under extreme conditions. The air cleaning system is based on the adsorption of drug vapors by an activated carbon filter in the Vial Adaptor before the air is released out of the drug vial. The functionality of the carbon filter was also tested at the end of device’s shelf life, and after a contact period with drug vapors for 7 days. Cyclophosphamide and 5-fluorouracil were the chemotherapy drugs tested. Methods The Vial Adaptor was attached to a drug vial and both were placed in a glass vessel. A needle was punctured through the vessel stopper and the Vial Adaptor septum to allow nitrogen gas to flow into the vial and to exit the vial via the air filter into the glass vessel which was connected to a cold trap. Potential contaminated surfaces in the trap system were wiped or rinsed to collect the escaped drug. Samples were analyzed using liquid chromatography tandem mass spectrometry. Results Cyclophosphamide and 5-fluorouracil were detected on most surfaces inside the trap system for all Vial Adaptors without an activated carbon filter. Contamination did not differ between the Vial Adaptors with and without membrane filter indicating no effect of the membrane filter. The results show no release of either drug for the Vial Adaptors with an activated carbon filter even after 3 years of simulated aging and 7 days of exposure to drug vapors. Conclusions Validation of air cleaning CSTDs is important to secure vapor and aerosol containment of chemotherapy and other hazardous drugs. The presented test method has proven to be appropriate for the validation of ChemfortTM Vial Adaptors. No release of cyclophosphamide and 5- fluorouracil was found even for Vial Adaptors after 3 years of simulated aging and 7 days of exposure to drug vapors.


2013 ◽  
Vol 2013 ◽  
pp. 1-8 ◽  
Author(s):  
Edris Bazrafshan ◽  
Hossein Moein ◽  
Ferdos Kord Mostafapour ◽  
Shima Nakhaie

Dairy industry wastewater is characterized by high biochemical oxygen demand (BOD5), chemical oxygen demand (COD), and other pollution load. The purpose of this study was to investigate the effects of the operating parameters such as applied voltage, number of electrodes, and reaction time on a real dairy wastewater in the electrocoagulation process. For this purpose, aluminum electrodes were used in the presence of potassium chloride as electrolytes. It has been shown that the removal efficiency of COD, BOD5, and TSS increased with increasing the applied voltage and the reaction time. The results indicate that electrocoagulation is efficient and able to achieve 98.84% COD removal, 97.95% BOD5removal, 97.75% TSS removal, and >99.9% bacterial indicators at 60 V during 60 min. The experiments demonstrated the effectiveness of electrocoagulation techniques for the treatment of dairy wastewaters. Finally, the results demonstrated the technical feasibility of electrocoagulation process using aluminum electrodes as a reliable technique for removal of pollutants from dairy wastewaters.


2021 ◽  
Vol 5 (1) ◽  
pp. 223-232
Author(s):  
Mohammed Jr. Kinta ◽  
A. V. Ayanwale ◽  
U. N. Keke ◽  
Y. I. Auta ◽  
B. S. Adama ◽  
...  

Developing countries like Nigeria are faced with increased in generation of domestic, industrial and agricultural wastes, with a large percentage moving. This study evaluates the physico-chemical and some heavy metals concentration in three common species of fish from Tungan Kawo reservoir Kontagora, Nigeria; using standard methods between (July 2018 – February 2019); at four different sampling stations of human activities on the water. Five heavy metals were evaluated (Lead, Copper, Manganese, Iron and Chromium) in the fish samples. Phosphate (0.4 – 2.5) mg/L, Nitrate (3.2 – 7.5) mg/L, Temperature (27 – 32.4) 0C, Dissolved Oxygen (2.4 – 5.2 mg/L), Conductivity (81 – 125 µS/cm), Biochemical Oxygen Demand (1.9 – 4.4 mg/L), Alkalinity (mg/L) and Total Dissolved Solids (117 – 198) ppm were within the standard for drinking water and survival of fish.  However, the pH (6.3 – 9.8) was above the standard for NIS and WHO drinking water but can support aquatic life. Iron (0.64 ± 0.072 mg/kg) was the most highly concentrated in Synodontis clarias while lead (0.01 ± 0.013 mg/kg) was the lowest in Oreochromis niloticus and Coptidon zillii (formerly Tilapia zillii. This current finding indicates that the water is safe for both aquatic life and domestic purpose but not suitable for direct human consumption without being properly treated. However, there is the need for regular monitoring of the heavy metals load in this water body and the aquatic organisms because of the long term effects


2015 ◽  
Vol 28 (1) ◽  
pp. 9-17 ◽  
Author(s):  
Thomas Bersinger ◽  
Isabelle Le Hécho ◽  
Gilles Bareille ◽  
Thierry Pigot ◽  
Alexandre Lecomte

Continuous monitoring of the sanitation network of the urban catchment of Pau (southwest France) has been performed since March 2012 using rain gauges, flowmeters, as well as turbidity and conductivity probes. Good correlations were obtained between turbidity, total suspended solids (TSS) and chemical oxygen demand (COD) on the one hand, and conductivity and total nitrogen on the other hand. This allowed an instantaneous and continuous estimation of pollutant concentrations and fluxes since that date. In the present paper we focused on the results of October 2012, which was characterized by alternating periods of dry and rainy events. Turbidity and conductivity raw data show different trends during the study period depending on the parameter and the rain events. A turbidity peak is observed at the beginning of each rain event but its amplitude varies with the intensity of the rain and the length of the preceding dry weather period. Conversely, conductivity decrease during each rain event implying, that rain water acts as a dilution factor. The behaviour of COD and total nitrogen differ markedly due to their partitioning between the dissolved (total nitrogen) and particulate phases (COD). Daily pollutant fluxes allow a global comprehension and monitoring of the sewer system. Important COD fluxes during a rain event preceded by a long dry weather period highlight the importance of erosion of sedimentary deposits in the sewerage network. During these events, important fluxes are discharged into receiving water leading to the question of the impact on aquatic life. Generally, these results highlight the potential of online monitoring to better understand the behaviour of the sewer network on long or short time scales. This could be a useful tool to manage wastewater treatment.


Author(s):  
Anupama Bhardwaj ◽  
Jagtar Singh ◽  
Sonia Chaman ◽  
Amit Joshi

Objective: The objective of this study is to make sure biotreatment process used for treatment of dairy wastewater (DWW) is safe for human and its surrounding environment; microbes were evaluated for their antibiotic resistance profile against commonly prescribed antibiotics. Methods: Microbes were isolated using spread plating and streaking method and used to treat DWW. Reduction in organic load in DWW was determined by comparing physicochemical parameters (PCP) of DWW before and after treatment process. After selection of efficient microbial isolates, they were evaluated for their antibiotic resistance profile using antibiotic disc diffusion method. Results: In this work, 53 microbes were isolated from DWW, and these microbial isolates were screened for DWW degradation capacity by analyzing PCP. Four microbial isolates E3, E5, E11 (bacterial isolates) and F5 (fungal isolate) showed highest reduction in chemical oxygen demand (COD), biological oxygen demand (BOD), and dissolved oxygen (DO) were selected for profound degradation of DWW under optimized conditions. Efficient four microbial isolates individually performed better under anaerobic conditions by showing maximum reduction 84%, 75%, and 77% in COD, BOD, and DO, respectively. After 72 hrs of antibiotic susceptibility testing, E3 strain had shown 100%, E5 90%, E11 70%, and F5 80% susceptibility to antibiotics. Conclusion: The present study concluded that four microbial isolates had the potential of reducing the organic load of DWW along with lessor or negligible adverse effect on human or its surrounding environment and they appear to be most promising strains for treatment of DWW. 


2016 ◽  
Vol 74 (7) ◽  
pp. 1509-1517 ◽  
Author(s):  
Linan Zhu ◽  
Hailing He ◽  
Chunli Wang

The hybrid membrane bioreactor (HMBR) has been applied in ship domestic sewage treatment under high volumetric loading for ship space saving. The mechanism and influence factors on the efficiency, including hydraulic retention time (HRT), dissolved oxygen (DO) of chemical oxygen demand (COD) removal were investigated. The HMBR's average COD removal rate was up to 95.13% on volumetric loading of 2.4 kgCOD/(m3•d) and the COD concentration in the effluent was 48.5 mg/L, far below the International Maritime Organization (IMO) discharge standard of 125 mg/L. DO had a more remarkable effect on the COD removal efficiency than HRT. In addition, HMBR revealed an excellent capability of resisting organics loading impact. Within the range of volumetric loading of 0.72 to 4.8 kg COD/(m3•d), the effluent COD concentration satisfied the discharge requirement of IMO. It was found that the organics degradation in the aeration tank followed the first-order reaction, with obtained kinetic parameters of vmax (2.79 d−1) and Ks (395 mg/L). The original finding of this study had shown the effectiveness of HMBR in organic contaminant degradation at high substrate concentration, which can be used as guidance in the full scale of the design, operation and maintenance of ship domestic sewage treatment devices.