Failure Analysis of Flip Chip C4 Package Using Focused Ion Beam Milling Technique

Author(s):  
Lihong Cao ◽  
Loc Tran ◽  
Wallace Donna

Abstract This article describes how Focused Ion Beam (FIB) milling methodology enhances the capability of package-level failure analysis on flip-chip packages by eliminating the artifacts induced by using conventional mechanical techniques. Dual- Beam Focused Ion Beam (DB FIB) cross sections were successful in detecting failure mechanisms related either to the die/C4 bump or package defect inside the organic substrate. This paper outlines detailed sample preparation techniques prior to performing the DB FIB cross-sections, along with case studies of DB FIB cross-sections.

1997 ◽  
Vol 3 (S2) ◽  
pp. 357-358
Author(s):  
C. Amy Hunt

The demand for TEM analysis in semiconductor failure analysis is rising sharply due to the shrinking size of devices. A well-prepared sample is a necessity for getting meaningful results. In the past decades, a significant amount of effort has been invested in improving sample preparation techniques for TEM specimens, especially precision cross-sectioning techniques. The most common methods of preparation are mechanical dimpling & ion milling, focused ion beam milling (FIBXTEM), and wedge mechanical polishing. Each precision XTEM technique has important advantages and limitations that must be considered for each sample.The concept for both dimpling & ion milling and wedge specimen preparation techniques is similar. Both techniques utilize mechanical polishing to remove the majority of the unwanted material, followed by ion milling to assist in final polishing or cleaning. Dimpling & ion milling produces the highest quality samples and is a relatively easy technique to master.


Author(s):  
R.J. Young ◽  
A. Buxbaum ◽  
B. Peterson ◽  
R. Schampers

Abstract Scanning transmission electron microscopy with scanning electron microscopes (SEM-STEM) has become increasing used in both SEM and dual-beam focused ion beam (FIB)-SEM systems. This paper describes modeling undertaken to simulate the contrast seen in such images. Such modeling provides the ability to help understand and optimize imaging conditions and also support improved sample preparation techniques.


Author(s):  
Ann N. Campbell ◽  
William F. Filter ◽  
Nicholas Antoniou

Abstract Both the increased complexity of integrated circuits, resulting in six or more levels of integration, and the increasing use of flip-chip packaging have driven the development of integrated circuit (IC) failure analysis tools that can be applied to the backside of the chip. Among these new approaches are focused ion beam (FIB) tools and processes for performing chip edits/repairs from the die backside. This paper describes the use of backside FIB for a failure analysis application rather than for chip repair. Specifically, we used FIB technology to prepare an IC for inspection of voided metal interconnects (“lines”) and vias. Conventional FIB milling was combined with a superenhanced gas assisted milling process that uses XeF2 for rapid removal of large volumes of bulk silicon. This combined approach allowed removal of the TiW underlayer from a large number of M1 lines simultaneously, enabling rapid localization and plan view imaging of voids in lines and vias with backscattered electron (BSE) imaging in a scanning electron microscope (SEM). Sequential cross sections of individual voided vias enabled us to develop a 3D reconstruction of these voids. This information clarified how the voids were formed, helping us identify the IC process steps that needed to be changed.


Author(s):  
Ng Sea Chooi ◽  
Chor Theam Hock ◽  
Ma Choo Thye ◽  
Khoo Poh Tshin ◽  
Dan Bockelman

Abstract Trends in the packaging of semiconductors are towards miniaturization and high functionality. The package-on-package(PoP) with increasing demands is beneficial in cost and space saving. The main failure mechanisms associated with PoP technology, including open joints and warpage, have created a lot of challenges for Assembly and Failure Analysis (FA). This paper outlines the sample preparation process steps to overcome the challenges to enable successful failure analysis and optical probing.


Author(s):  
Andrew J. Komrowski ◽  
N. S. Somcio ◽  
Daniel J. D. Sullivan ◽  
Charles R. Silvis ◽  
Luis Curiel ◽  
...  

Abstract The use of flip chip technology inside component packaging, so called flip chip in package (FCIP), is an increasingly common package type in the semiconductor industry because of high pin-counts, performance and reliability. Sample preparation methods and flows which enable physical failure analysis (PFA) of FCIP are thus in demand to characterize defects in die with these package types. As interconnect metallization schemes become more dense and complex, access to the backside silicon of a functional device also becomes important for fault isolation test purposes. To address these requirements, a detailed PFA flow is described which chronicles the sample preparation methods necessary to isolate a physical defect in the die of an organic-substrate FCIP.


Author(s):  
Jian-Shing Luo ◽  
Hsiu Ting Lee

Abstract Several methods are used to invert samples 180 deg in a dual beam focused ion beam (FIB) system for backside milling by a specific in-situ lift out system or stages. However, most of those methods occupied too much time on FIB systems or requires a specific in-situ lift out system. This paper provides a novel transmission electron microscopy (TEM) sample preparation method to eliminate the curtain effect completely by a combination of backside milling and sample dicing with low cost and less FIB time. The procedures of the TEM pre-thinned sample preparation method using a combination of sample dicing and backside milling are described step by step. From the analysis results, the method has applied successfully to eliminate the curtain effect of dual beam FIB TEM samples for both random and site specific addresses.


Author(s):  
Julien Goxe ◽  
Béatrice Vanhuffel ◽  
Marie Castignolles ◽  
Thomas Zirilli

Abstract Passive Voltage Contrast (PVC) in a Scanning Electron Microscope (SEM) or a Focused Ion Beam (FIB) is a key Failure Analysis (FA) technique to highlight a leaky gate. The introduction of Silicon On Insulator (SOI) substrate in our recent automotive analog mixed-signal technology highlighted a new challenge: the Bottom Oxide (BOX) layer, by isolating the Silicon Active Area from the bulk made PVC technique less effective in finding leaky MOSFET gates. A solution involving sample preparation performed with standard FA toolset is proposed to enhance PVC on SOI substrate.


Author(s):  
Roger Alvis ◽  
Jeff Blackwood ◽  
Sang-Hoon Lee ◽  
Matthew Bray

Abstract Semiconductor devices with critical dimensions less than 20nm are now being manufactured in volume. A challenge facing the failure analysis and process-monitoring community is two-fold. The first challenge of TEM sample prep of such small devices is that the basic need to end-point on a feature-of-interest pushes the imaging limit of the instrument being used to prepare the lamella. The second challenge posed by advanced devices is to prepare an artifact-free lamella from non-planar devices such as finFETs as well as from structures incorporating ‘non-traditional’ materials. These challenges are presently overcome in many advanced logic and memory devices in the focused ion beam-based TEM sample preparation processes by inverting the specimen prior to thinning to electron transparency. This paper reports a highthroughput method for the routine preparation of artifact-free TEM lamella of 20nm thickness, or less.


Author(s):  
Steven B. Herschbein ◽  
Hyoung H. Kang ◽  
Scott L. Jansen ◽  
Andrew S. Dalton

Abstract Test engineers and failure analyst familiar with random access memory arrays have probably encountered the frustration of dealing with address descrambling. The resulting nonsequential internal bit cell counting scheme often means that the location of the failing cell under investigation is nowhere near where it is expected to be. A logical to physical algorithm for decoding the standard library block might have been provided with the design, but is it still correct now that the array has been halved and inverted to fit the available space in a new processor chip? Off-line labs have traditionally been tasked with array layout verification. In the past, hard and soft failures could be induced on the frontside of finished product, then bitmapped to see if the sites were in agreement. As density tightened, flip-chip FIB techniques to induce a pattern of hard fails on packaged devices came into practice. While the backside FIB edit method is effective, it is complex and expensive. The installation of an in-line Dual Beam FIB created new opportunities to move FA tasks out of the lab and into the FAB. Using a new edit procedure, selected wafers have an extensive pattern of defects 'written' directly into the memory array at an early process level. Bitmapping of the RAM blocks upon wafer completion is then used to verify correlation between the physical damaged cells and the logical sites called out in the test results. This early feedback in-line methodology has worked so well that it has almost entirely displaced the complex laboratory procedure of backside FIB memory array descramble verification.


Sign in / Sign up

Export Citation Format

Share Document