scholarly journals More Bone with Less Minerals? The Effects of Dietary Phosphorus on the Post-Cranial Skeleton in Zebrafish

2020 ◽  
Vol 21 (15) ◽  
pp. 5429
Author(s):  
Silvia Cotti ◽  
Ann Huysseune ◽  
Wolfgang Koppe ◽  
Martin Rücklin ◽  
Federica Marone ◽  
...  

Dietary phosphorus (P) is essential for bone mineralisation in vertebrates. P deficiency can cause growth retardation, osteomalacia and bone deformities, both in teleosts and in mammals. Conversely, excess P supply can trigger soft tissue calcification and bone hypermineralisation. This study uses a wide range of complementary techniques (X-rays, histology, TEM, synchrotron X-ray tomographic microscopy, nanoindentation) to describe in detail the effects of dietary P on the zebrafish skeleton, after two months of administering three different diets: 0.5% (low P, LP), 1.0% (regular P, RP), and 1.5% (high P, HP) total P content. LP zebrafish display growth retardation and hypomineralised bones, albeit without deformities. LP zebrafish increase production of non-mineralised bone matrix, and osteoblasts have enlarged endoplasmic reticulum cisternae, indicative for increased collagen synthesis. The HP diet promotes growth, high mineralisation, and stiffness but causes vertebral centra fusions. Structure and arrangement of bone matrix collagen fibres are not influenced by dietary P in all three groups. In conclusion, low dietary P content stimulates the formation of non-mineralised bone without inducing malformations. This indicates that bone formation and mineralisation are uncoupled. In contrast, high dietary P content promotes mineralisation and vertebral body fusions. This new zebrafish model is a useful tool to understand the mechanisms underlying osteomalacia and abnormal mineralisation, due to underlying variations in dietary P levels.

Author(s):  
Y. Kokubo ◽  
W. H. Hardy ◽  
J. Dance ◽  
K. Jones

A color coded digital image processing is accomplished by using JEM100CX TEM SCAN and ORTEC’s LSI-11 computer based multi-channel analyzer (EEDS-II-System III) for image analysis and display. Color coding of the recorded image enables enhanced visualization of the image using mathematical techniques such as compression, gray scale expansion, gamma-processing, filtering, etc., without subjecting the sample to further electron beam irradiation once images have been stored in the memory.The powerful combination between a scanning electron microscope and computer is starting to be widely used 1) - 4) for the purpose of image processing and particle analysis. Especially, in scanning electron microscopy it is possible to get all information resulting from the interactions between the electron beam and specimen materials, by using different detectors for signals such as secondary electron, backscattered electrons, elastic scattered electrons, inelastic scattered electrons, un-scattered electrons, X-rays, etc., each of which contains specific information arising from their physical origin, study of a wide range of effects becomes possible.


Cosmetics ◽  
2021 ◽  
Vol 8 (3) ◽  
pp. 62
Author(s):  
Giovanni Tafuro ◽  
Alessia Costantini ◽  
Giovanni Baratto ◽  
Stefano Francescato ◽  
Laura Busata ◽  
...  

As public attention on sustainability is increasing, the use of polysaccharides as rheological modifiers in skin-care products is becoming the first choice. Polysaccharide associations can be used to increase the spreading properties of products and to optimize their sensorial profile. Since the choice of natural raw materials for cosmetics is wide, instrumental methodologies are useful for formulators to easily characterize the materials and to create mixtures with specific applicative properties. In this work, we performed rheological and texture analyses on samples formulated with binary and ternary associations of polysaccharides to investigate their structural and mechanical features as a function of the concentration ratios. The rheological measurements were conducted under continuous and oscillatory flow conditions using a rotational rheometer. An immersion/de-immersion test conducted with a texture analyzer allowed us to measure some textural parameters. Sclerotium gum and iota-carrageenan imparted high viscosity, elasticity, and firmness in the system; carob gum and pectin influenced the viscoelastic properties and determined high adhesiveness and cohesiveness. The results indicated that these natural polymers combined in appropriate ratios can provide a wide range of different textures and that the use of these two complementary techniques represents a valid pre-screening tool for the formulation of green products.


2010 ◽  
Vol 1 (SRMS-7) ◽  
Author(s):  
David Pennicard ◽  
Heinz Graafsma ◽  
Michael Lohmann

The new synchrotron light source PETRA-III produced its first beam last year. The extremely high brilliance of PETRA-III and the large energy range of many of its beamlines make it useful for a wide range of experiments, particularly in materials science. The detectors at PETRA-III will need to meet several requirements, such as operation across a wide dynamic range, high-speed readout and good quantum efficiency even at high photon energies. PETRA-III beamlines with lower photon energies will typically be equipped with photon-counting silicon detectors for two-dimensional detection and silicon drift detectors for spectroscopy and higher-energy beamlines will use scintillators coupled to cameras or photomultiplier tubes. Longer-term developments include ‘high-Z’ semiconductors for detecting high-energy X-rays, photon-counting readout chips with smaller pixels and higher frame rates and pixellated avalanche photodiodes for time-resolved experiments.


2018 ◽  
Vol 620 ◽  
pp. A18 ◽  
Author(s):  
C. H. A. Logan ◽  
B. J. Maughan ◽  
M. N. Bremer ◽  
P. Giles ◽  
M. Birkinshaw ◽  
...  

Context. The XMM-XXL survey has used observations from the XMM-Newton observatory to detect clusters of galaxies over a wide range in mass and redshift. The moderate PSF (FWHM ~ 6″ on-axis) of XMM-Newton means that point sources within or projected onto a cluster may not be separated from the cluster emission, leading to enhanced luminosities and affecting the selection function of the cluster survey. Aims. We present the results of short Chandra observations of 21 galaxy clusters and cluster candidates at redshifts z > 1 detected in the XMM-XXL survey in X-rays or selected in the optical and infra-red. Methods. With the superior angular resolution of Chandra, we investigate whether there are any point sources within the cluster region that were not detected by the XMM-XXL analysis pipeline, and whether any point sources were misclassified as distant clusters. Results. Of the 14 X-ray selected clusters, 9 are free from significant point source contamination, either having no previously unresolved sources detected by Chandra or with less than about 10% of the reported XXL cluster flux being resolved into point sources. Of the other five sources, one is significantly contaminated by previously unresolved AGN, and four appear to be AGN misclassified as clusters. All but one of these cases are in the subset of less secure X-ray selected cluster detections and the false positive rate is consistent with that expected from the XXL selection function modelling. We also considered a further seven optically selected cluster candidates associated with faint XXL sources that were not classed as clusters. Of these, three were shown to be AGN by Chandra, one is a cluster whose XXL survey flux was highly contaminated by unresolved AGN, while three appear to be uncontaminated clusters. By decontaminating and vetting these distant clusters, we provide a pure sample of clusters at redshift z > 1 for deeper follow-up observations, and demonstrate the utility of using Chandra snapshots to test for AGN in surveys with high sensitivity but poor angular resolution.


2013 ◽  
Vol 46 (5) ◽  
pp. 1508-1512 ◽  
Author(s):  
Byron Freelon ◽  
Kamlesh Suthar ◽  
Jan Ilavsky

Coupling small-angle X-ray scattering (SAXS) and ultra-small-angle X-ray scattering (USAXS) provides a powerful system of techniques for determining the structural organization of nanostructured materials that exhibit a wide range of characteristic length scales. A new facility that combines high-energy (HE) SAXS and USAXS has been developed at the Advanced Photon Source (APS). The application of X-rays across a range of energies, from 10 to 50 keV, offers opportunities to probe structural behavior at the nano- and microscale. An X-ray setup that can characterize both soft matter or hard matter and high-Zsamples in the solid or solution forms is described. Recent upgrades to the Sector 15ID beamline allow an extension of the X-ray energy range and improved beam intensity. The function and performance of the dedicated USAXS/HE-SAXS ChemMatCARS-APS facility is described.


2015 ◽  
Vol 2 (1) ◽  
pp. 246-251 ◽  
Author(s):  
K. Mukai

In recent years, recurrent nova eruptions are often observed very intensely in wide range of wavelengths from radio to optical to X-rays. Here I present selected highlights from recent multi-wavelength observations. The enigma of T Pyx is at the heart of this paper. While our current understanding of CV and symbiotic star evolution can explain why certain subset of recurrent novae have high accretion rate, that of T Pyx must be greatly elevated compared to the evolutionary mean. At the same time, we have extensive data to be able to estimate how the nova envelope was ejected in T Pyx, and it turns to be a rather complex tale. One suspects that envelope ejection in recurrent and classical novae in general is more complicated than the textbook descriptions. At the end of the review, I will speculate that these two may be connected.


1972 ◽  
Vol 14 ◽  
pp. 642-646
Author(s):  
G. A. Gurzadyan ◽  
J. B. Ohanesyan

The problem of energy calibration of astrophysical apparatus is essential for every or almost every space experiment. The utilization of synchrotron radiation from an electronic accelerator should perhaps be taken as an ideal solution of this problem, if of course, such a possibility is available.Special equipment for the extraction of synchrotron radiation has been devised at the circular electron accelerator with a maximum electron energy of 6 GeV, in the Physics Institute of Erevan (Gurzadyan and Ohanesyan, 1972). The equipment is designed primarily for the energy calibration of astronomical apparatus operating in a vacuum and hard ultraviolet and X rays. However, the equipment can also be applied to a wide range of experiments relating to the physics of solids, crystallography, physics of thin films, X rays, etc.


1990 ◽  
Vol 01 (01) ◽  
pp. 1-29 ◽  
Author(s):  
KEIZO ISHII ◽  
SUSUMU MORITA

Continuous X rays produced by light-ion·atom collisions, which mainly form continuous backgrounds and determine the detection limit of PIXE, have been experimentally and theoretically studied, and it is shown that the experimental results over the wide range of projectile-ion energy from 0.5 MeV to 40 MeV can be well explained by three kinds of radiative process: atomic bremsstrahlung (AB), secondary-electron bremsstrahlung (SEB), and quasifree electron bremsstrahlung (QFEB). Results on the X-ray spectra, the projectile-energy dependence and the projectile-charge dependence, and on the angular distribution of these bremsstrahlungs will be summarized and the importance of AB in heavy-ion atom collision is presented. Discussions are also given on the other origins of continuous backgrounds such as the Compton scattering background, cosmic rays, the Rutherford scattering background, piling up of signals and response functions of detector, charge up effect of the target and natural backgrounds. On the basis of analyses of continuous backgrounds, the detection limit of PIXE is estimated.


2021 ◽  
Vol 27 (4) ◽  
pp. 279-289
Author(s):  
Elahe Sayyadi ◽  
Asghar Mesbahi ◽  
Reza Eghdam Zamiri ◽  
Farshad Seyyed Nejad

Abstract Introduction: The present study aimed to investigate the radiation protection properties of silicon-based composites doped with nano-sized Bi2O3, PbO, Sm2O3, Gd2O3, WO3, and IrO2 particles. Radiation shielding properties of Sm2O3 and IrO2 nanoparticles were investigated for the first time in the current study. Material and methods: The MCNPX (2.7.0) Monte Carlo code was utilized to calculate the linear attenuation coefficients of single and multi-nano structured composites over the X-ray energy range of 10–140 keV. Homogenous distribution of spherical nanoparticles with a diameter of 100 nm in a silicon rubber matrix was simulated. The narrow beam geometry was used to calculate the photon flux after attenuation by designed nanocomposites. Results: Based on results obtained for single nanoparticle composites, three combinations of different nano-sized fillers Sm2O3+WO3+Bi2O3, Gd2O3+WO3+Bi2O3, and Sm2O3+WO3+PbO were selected, and their shielding properties were estimated. In the energy range of 20-60 keV Sm2O3 and Gd2O3 nanoparticles, in 70-100 keV energy range WO3 and for photons energy higher than 90 keV, PbO and Bi2O3 nanoparticles showed higher attenuation. Despite its higher density, IrO2 had lower attenuation compared to other nanocomposites. The results showed that the nanocomposite containing Sm2O3, WO3, and Bi2O3 nanoparticles provided better shielding among the studied samples. Conclusions: All studied multi-nanoparticle nanocomposites provided optimum shielding properties and almost 8% higher attenuation relative to single nano-based composites over a wide range of photon energy used in diagnostic radiology. Application of these new composites is recommended in radiation protection. Further experimental studies are suggested to validate our findings.


2021 ◽  
Vol 7 ◽  
pp. e495
Author(s):  
Saleh Albahli ◽  
Hafiz Tayyab Rauf ◽  
Abdulelah Algosaibi ◽  
Valentina Emilia Balas

Artificial intelligence (AI) has played a significant role in image analysis and feature extraction, applied to detect and diagnose a wide range of chest-related diseases. Although several researchers have used current state-of-the-art approaches and have produced impressive chest-related clinical outcomes, specific techniques may not contribute many advantages if one type of disease is detected without the rest being identified. Those who tried to identify multiple chest-related diseases were ineffective due to insufficient data and the available data not being balanced. This research provides a significant contribution to the healthcare industry and the research community by proposing a synthetic data augmentation in three deep Convolutional Neural Networks (CNNs) architectures for the detection of 14 chest-related diseases. The employed models are DenseNet121, InceptionResNetV2, and ResNet152V2; after training and validation, an average ROC-AUC score of 0.80 was obtained competitive as compared to the previous models that were trained for multi-class classification to detect anomalies in x-ray images. This research illustrates how the proposed model practices state-of-the-art deep neural networks to classify 14 chest-related diseases with better accuracy.


Sign in / Sign up

Export Citation Format

Share Document