scholarly journals Methodological issues of metrological analysis of planned medieval towns and villages

ACTA IMEKO ◽  
2021 ◽  
Vol 10 (1) ◽  
pp. 217
Author(s):  
Anna Maria Kubicka ◽  
Maria Legut-Pintal

<p class="Abstract">In this paper, we illustrate problems related to the application of two methods used for the reconstruction of the parcellation of medieval towns: modular analysis and the cosine quantogram. We propose the usage of the cosine quantogram, which is rarely used to study urban layout, for the identification of units of measurement in regular medieval towns. Based on two examples from the region of Silesia, Poland, Namyslów and Dzierzoniów, we discuss the usefulness of both methods in the reconstruction of the original measuring system and town layout. For the first time, we have applied these two methods to the study of the layout of a regular village. Despite the limitations, such as the level of precision in the construction of a medieval town’s layout at the time of its foundation, later changes to the division of plots and the known inaccuracy of modern maps, it seems that combining both methods allows the determination of the module used for the planning of the original urban layout. The application of the cosine quantogram can be useful for improving the results of modular analysis. Nevertheless, the results of both methods should be verified against archaeological results and historical research.</p>

Author(s):  
István Lakatos ◽  
Dániel Pup ◽  
Dávid Czeglédi

The transmitted power of motors can be defined by test bench examinations, in which the motor needs to be dismounted. By applying diagnostic methods only minimal disassembly, or indeed none at all, is necessary. In this paper diagnostic methods are systematized by different studies. Moreover, a new diagnostic procedure (established by the authors) is also introduced, which can be carried out by a relatively cheap measuring system design. Power measurement on a roller test bench is a well-tried technique for vehicle examination. Basically, the wheel parameters (tractive force, torque, power) are measured, but there are also procedures for motor power measurement. By applying the new procedure, the diagnostic method, (simple construction and test bench construction at a favourable price) torque and power characteristics of the mounted motor can be defined. The theoretical considerations of the new measuring technique and the implementation of the measuring system are introduced in this paper. Test bench for drive motor power and torque curve determination. In this study the diagnostical measuring systems and, for the first time, the measuring principle and technology of the new theory-based roller power test bench are presented. For its construction measurements have been carried out which make an important contribution to the research. The results of the research contribute to the development of diagnostics methods and to making them more wide-spread.


2020 ◽  
pp. 22-38
Author(s):  
Natalia Guseva ◽  
Vitaliy Berdutin

At present, the problem of establishing disability is a point at issue in Russia. Despite the fact that medical criteria for disability are being developed very actively, high-quality methods for assessing social hallmarks are still lacking. Since disability is a phenomenon inherent in any society, each state forms a social and economic policy for people with disabilities in accordance with its level of development, priorities and opportunities. We have proposed a three-stage model, which includes a system for the consistent solution of the main tasks aimed at studying the causes and consequences of the problems encountered today in the social protection of citizens with health problems. The article shows why the existing approaches to the determination of disability and rehabilitation programs do not correspond to the current state of Russian society and why a decrease in the rate of persons recognized as disabled for the first time does not indicate an improvement in the health of the population. The authors proposed a number of measures with a view to correcting the situation according to the results of the study.


2020 ◽  
Vol 17 (3) ◽  
pp. 206-210
Author(s):  
Ty Viet Pham ◽  
Thang Quoc Le ◽  
Anh Tuan Le ◽  
Hung Quoc Vo ◽  
Duc Viet Ho

A phytochemical investigation of the leaves of Annona reticulata led to the isolation and structural determination of β-sitosterol (1), ent-pimara-8(14),15-dien-19-oic acid (2), ent-pimara- 8(14),15-dien-19-ol (3), quercetin (4), quercetin 3-O-α-L-arabinopyranoside (5), and a mixture of quercetin 3-O-β-D-galactopyranoside (6a) and quercetin 3-O-β-D-glucopyranoside (6b). Of these, compounds 2 and 3 were isolated from the genus Annona for the first time. Compound 3 showed strong cytotoxicity against SK-LU-1 and SW626 cell lines with IC50 values of 17.64 ± 1.07 and 19.79 ± 1.41 μg mL-1, respectively.


2019 ◽  
Vol 15 (6) ◽  
pp. 568-573
Author(s):  
Soheil Sedaghat ◽  
Ommoleila Molavi ◽  
Akram Faridi ◽  
Ali Shayanfar ◽  
Mohammad Reza Rashidi

Background: Signal transducer and activator of transcription 3 (STAT3), an oncogenic protein found constitutively active in many types of human malignancies, is considered to be a promising target for cancer therapy. Objective: In this study for the first time, a simple and accurate method has been developed for the determination of a STAT3 dimerization inhibitor called stattic in aqueous and plasma samples. Methods: A reverse-phase high-performance liquid chromatography (RP-HPLC) composed of C18 column as stationary phase, and the mixture of acetonitrile (60%) and water (40%) as mobile phase with a UV detection at 215 nm were applied for quantification of stattic. The developed method was validated by Food and Drug Administration (FDA) guideline. Results: The method provided a linear range between 1-40 and 2.5-40 µg mL-1 for aqueous and plasma samples, respectively, with a correlation coefficient of 0.999. The accuracy (as recovery) of the developed method was found to be between 95-105% for aqueous medium and 85-115% for plasma samples. The precision (as relative standard deviation) for aqueous and plasma samples was less than 6% and 15%, respectively. The sensitivity of the developed method based on FDA guideline was 1 µg mL-1 for aqueous and 2.5 µg mL-1 for plasma samples. Conclusion: These results show that the established method is a fast and accurate quantification for stattic in aqueous and plasma samples.


2021 ◽  
Author(s):  
Lijuan Liu ◽  
Shengting Zhang ◽  
Xiaodan Zheng ◽  
Hongmei Li ◽  
Qi Chen ◽  
...  

Fusobacterium nucleatum has been employed for the first time to synthesize fluorescent carbon dots which could be applied for the determination of Fe3+ ions in living cells and bioimaging in vitro and in vivo with excellent biocompatibility.


Author(s):  
Guglielmo Federico Antonio Brunetti ◽  
Samuele De Bartolo ◽  
Carmine Fallico ◽  
Ferdinando Frega ◽  
Maria Fernanda Rivera Velásquez ◽  
...  

AbstractThe spatial variability of the aquifers' hydraulic properties can be satisfactorily described by means of scaling laws. The latter enable one to relate the small (typically laboratory) scale to the larger (typically formation/regional) ones, therefore leading de facto to an upscaling procedure. In the present study, we are concerned with the spatial variability of the hydraulic conductivity K into a strongly heterogeneous porous formation. A strategy, allowing one to identify correctly the single/multiple scaling of K, is applied for the first time to a large caisson, where the medium was packed. In particular, we show how to identify the various scaling ranges with special emphasis on the determination of the related cut-off limits. Finally, we illustrate how the heterogeneity enhances with the increasing scale of observation, by identifying the proper law accounting for the transition from the laboratory to the field scale. Results of the present study are of paramount utility for the proper design of pumping tests in formations where the degree of spatial variability of the hydraulic conductivity does not allow regarding them as “weakly heterogeneous”, as well as for the study of dispersion mechanisms.


Sensors ◽  
2021 ◽  
Vol 21 (5) ◽  
pp. 1612
Author(s):  
Andrea Paut ◽  
Ante Prkić ◽  
Ivana Mitar ◽  
Perica Bošković ◽  
Dražan Jozić ◽  
...  

A novel ion-selective electrode with membranes based on iron(III) phosphate and silver sulfide integrated into a completely new electrode body design has been developed for the determination of iron(III) cations. The best response characteristics with linear potential change were found in the iron(III) concentration range from 3.97× 10−5 to 10−2 mol L−1. The detection limit was found to be 2.41× 10−5 mol L−1 with a slope of –20.53 ± 0.63 and regression coefficient of 0.9925, while the quantification limit was 3.97× 10−5 M. The potential change per concentration decade ranged from –13.59 ± 0.54 to –20.53 ± 1.56 for Electrode Body 1 (EB1) and from –17.28 ± 1.04 to –24 ± 1.87 for Electrode Body 2 (EB2), which is presented for the first time in this work. The prepared electrode has a long lifetime and the ability to detect changes in the concentration of iron cations within 20 s. Membrane M1 showed high recoveries in the determination of iron cations in iron(III) standard solutions (98.2–101.2%) as well as in two different pharmaceuticals (98.6–106.5%). This proves that this type of sensor is applicable in the determination of ferric cations in unknown samples, and the fact that all sensor parts are completely manufactured in our laboratory proves the simplicity of the method.


Molecules ◽  
2021 ◽  
Vol 26 (6) ◽  
pp. 1602
Author(s):  
Ya-Ping Guo ◽  
Hong Yang ◽  
Ya-Li Wang ◽  
Xiao-Xiang Chen ◽  
Ke Zhang ◽  
...  

Crataegi folium have been used as medicinal and food materials worldwide due to its pharmacological activities. Although the leaves of Crataegus songorica (CS), Crataegus altaica (CA) and Crataegus kansuensis (CK) have rich resources in Xinjiang, China, they can not provide insights into edible and medicinal aspects. Few reports are available on the qualitative and quantitative analysis of flavonoids compounds of their leaves. Therefore, it is necessary to develop efficient methods to determine qualitative and quantitative flavonoids compounds in leaves of CS, CA and CK. In the study, 28 unique compounds were identified in CS versus CK by qualitative analysis. The validated quantitative method was employed to determine the content of eight flavonoids of the leaves of CS, CA and CK within 6 min. The total content of eight flavonoids was 7.8–15.1 mg/g, 0.1–9.1 mg/g and 4.8–10.7 mg/g in the leaves of CS, CA and CK respectively. Besides, the best harvesting periods of the three species were from 17th to 26th September for CS, from 30th September to 15th October for CA and CK. The validated and time-saving method was successfully implemented for the analysis of the content of eight flavonoids compounds in CS, CA and CK for the first time.


Analytica ◽  
2021 ◽  
Vol 2 (2) ◽  
pp. 38-49
Author(s):  
Ettore Guerriero ◽  
Massimo Iorizzo ◽  
Marina Cerasa ◽  
Ivan Notardonato ◽  
Bruno Testa ◽  
...  

The paper would like to show a direct injection into GC-MS/QqQ for the determination of secondary aromas in white wine samples fermented in two different ways. The procedure has been compared with more traditional methods used in this field, i.e., headspace analysis and liquid–liquid extraction. The application of such direct injection, for the first time in the literature, allows us to analyze Volatile Organic Compounds (VOCs) in the range 0.1–100 µg mL−1, with Limits of Detection (LODs) and Limits of Quantification (LOQs) between 0.01–0.05 µg mL−1 and 0.03–0.09 µg mL−1, respectively, intraday and interday below 5.6% and 8.5%, respectively, and recoveries above 92% at two different fortification levels. The procedure has been applied to real wine samples: it evidences how the fermentation in wood (cherry) barrel yields higher VOC levels than ones in wine fermented in steel tank, causing production of different secondary aromas and different relative flavors.


Sign in / Sign up

Export Citation Format

Share Document