scholarly journals Device reliability challenges for modern semiconductor circuit design – a review

2009 ◽  
Vol 7 ◽  
pp. 201-211 ◽  
Author(s):  
C. Schlünder

Abstract. Product development based on highly integrated semiconductor circuits faces various challenges. To ensure the function of circuits the electrical parameters of every device must be in a specific window. This window is restricted by competing mechanisms like process variations and device degradation (Fig. 1). Degradation mechanisms like Negative Bias Temperature Instability (NBTI) or Hot Carrier Injection (HCI) lead to parameter drifts during operation adding on top of the process variations. The safety margin between real lifetime of MOSFETs and product lifetime requirements decreases at advanced technologies. The assignment of tasks to ensure the product lifetime has to be changed for the future. Up to now technology development has the main responsibility to adjust the technology processes to achieve the required lifetime. In future, reliability can no longer be the task of technology development only. Device degradation becomes a collective challenge for semiconductor technologist, reliability experts and circuit designers. Reliability issues have to be considered in design as well to achieve reliable and competitive products. For this work, designers require support by smart software tools with built-in reliability know how. Design for reliability will be one of the key requirements for modern product designs. An overview will be given of the physical device damage mechanisms, the operation conditions within circuits leading to stress and the impact of the corresponding device parameter degradation on the function of the circuit. Based on this understanding various approaches for Design for Reliability (DfR) will be described. The function of aging simulators will be explained and the flow of circuit-simulation will be described. Furthermore, the difference between full custom and semi custom design and therefore, the different required approaches will be discussed.

2011 ◽  
Vol 9 ◽  
pp. 225-230
Author(s):  
S. More ◽  
M. Fulde ◽  
F. Chouard ◽  
D. Schmitt-Landsiedel

Abstract. This paper discusses reliability analysis of a buffer circuit targeted for an analog to digital converter application. The circuit designed in a 32 nm high-κ metal gate CMOS technology was investigated by circuit simulation and sensitivity analysis. This analysis was conducted for realistic time varying (AC) stress. As aging effects, negative and positive bias temperature instability, conducting and non-conducting hot carrier injection are taken into consideration. The aging contributions of these effects on the different transistors in the buffer circuit and on different buffer performance figures are evaluated. Using these results, the impact of an aged buffer circuit on the performance of a successive approximation ADC circuit is evaluated. The most severely affected performance due to aging is amplifier offset, which leads to time varying gain error in the ADC circuit.


2011 ◽  
Vol 2011 (1) ◽  
pp. 000891-000895 ◽  
Author(s):  
Abdelghani Renbi ◽  
Johan Carlson ◽  
Jerker Delsing

This paper demonstrates statistically the impact of PCB manufacturing variations on the characteristic impedance. Moreover, it shows that the characteristics of the PCBs vary across different suppliers. These differences cannot be tolerated in some applications where the characteristic impedance is restricted to be within a specific range. We sampled 3 × 20 PCBs, each batch of twenty is ordered from a different manufacturer. The sampling consist of measuring the phase shift between the reected and the incident signals when injecting a 180 MHz sinewave into a PCB trace. The trace is selected to be the same for all samples. All the PCBs are ordered to be identical and designed for 50 Ω devices. Our conclusion was drawn after running the T-tests to assess statistically the significance of the difference occurring between the PCBs. Based on the computed P-values all the three batches are different from each other in the mean of the measured phase shift with 95 % confidence. The difference between the measured and the expected characteristic impedance is found as 3 %, 10 % and 20 % for these three manufacturers. We also witnessed board-to-board variations even within the same batch and from the same supplier due to the process instability by looking at the probability density of having the same phase shift that is equal to the mean. Some samples shown 2.6 % to 3.5 % difference above the mean.


2019 ◽  
Vol 22 (1) ◽  
pp. 5-11 ◽  
Author(s):  
Atsu Divine Kafui ◽  
István Seres ◽  
István Farkas

Abstract Solar photovoltaic power generation capacity is rising continuously as a result of various regional, sub-regional renewable energy policies and the impact of technology development, as well as the increasing environmental concerns. Characteristics of photovoltaic modules are provided by manufacturers after they have been tested indoors under standard test conditions. These parameters may vary under exterior conditions. It is thus imperative to establish the quantity of the energy produced by photovoltaic modules under real operation conditions. This study sought to assess the performance of different kinds of photovoltaic module technologies in the city of Gödöllő, Hungary, and ascertain the behaviour of the modules under real outdoor conditions. Modules include amorphous silicon (a-Si), monocrystalline silicon (mc-Si), polycrystalline silicon (pc-Si), transparent monocrystalline silicon module (mc-Si). Measurement of the module characteristics was performed and various meteorological parameters were obtained. Performance parameters such as performance ratio and efficiency are given and analysed. Module temperature was estimated and evaluated in comparison with experimental values. Energy conversion rates of the modules were determined as 9.4%, 4.4%, 10.3%, 8.2% and 10.4% for mc-Si module transparent glass (165 Wp), a-Si module (glass 40Wp), pc-Si module (105 Wp), pc-Si module (60 Wp) and mc-Si (PV-T 180 Wp), respectively. Under the given outdoor conditions, the highest average performance ratio of 85.2% was obtained for the mc-Si module (transparent glass, 165 Wp), exhibiting the best performance, while pc–Si module (60 Wp) showed the least average performance ratio of 71.8%.


2019 ◽  
pp. 109-123
Author(s):  
I. E. Limonov ◽  
M. V. Nesena

The purpose of this study is to evaluate the impact of public investment programs on the socio-economic development of territories. As a case, the federal target programs for the development of regions and investment programs of the financial development institution — Vnesheconombank, designed to solve the problems of regional development are considered. The impact of the public interventions were evaluated by the “difference in differences” method using Bayesian modeling. The results of the evaluation suggest the positive impact of federal target programs on the total factor productivity of regions and on innovation; and that regional investment programs of Vnesheconombank are improving the export activity. All of the investments considered are likely to have contributed to the reduction of unemployment, but their implementation has been accompanied by an increase in social inequality.


2020 ◽  
Vol 4 (2) ◽  
pp. 150
Author(s):  
Farzana Sharmin Pamela Islam

As 21st century is the era of modern technologies with different aspects, it offers us to make the best use of them. After tape recorder and overhead projector (OHP), multimedia has become an important part of language classroom facilities for its unique and effective application in delivering and learning lesson. Although in many parts of Bangladesh, a South Asian developing country, where English enjoys the status of a foreign language, the use of multimedia in teaching and learning is viewed as a matter of luxury. However, nowadays the usefulness and the necessity of it are well recognized by the academics as well as the government. The study aims to focus on the difference between a traditional classroom void of multimedia and multimedia equipped classrooms at university level by explaining how multimedia support the students with enhanced opportunity to interact with diverse texts that give them more in-depth comprehension of the subject. It also focuses on audio-visual advantage of multimedia on the students’ English language learning. The study has followed a qualitative method to get an in-depth understanding of the impact of using multimedia in an English language classroom at tertiary level. For this purpose, the data have been collected from two different sources. Firstly, from students’ written response to  an open ended question as to their comparative experience of learning  lessons with and without multimedia facilities; and secondly, through  observation of English language classes at a private university of Dhaka, the capital city of Bangladesh. The discussion of the study is limited to  the use of multimedia in English language classroom using cartoons, images and music with a view to enhance students’ skills in academic writing, critical analysis of image and critical appreciation of music. For this purpose, cartoons in English language, images from Google and music from You Tube have got focused discussion in this paper.


2020 ◽  
Vol 68 (4) ◽  
pp. 303-314
Author(s):  
Yuna Park ◽  
Hyo-In Koh ◽  
University of Science and Technology, Transpo ◽  
University of Science and Technology, Transpo ◽  
University of Science and Technology, Transpo ◽  
...  

Railway noise is calculated to predict the impact of new or reconstructed railway tracks on nearby residential areas. The results are used to prepare adequate counter- measures, and the calculation results are directly related to the cost of the action plans. The calculated values were used to produce noise maps for each area of inter- est. The Schall 03 2012 is one of the most frequently used methods for the production of noise maps. The latest version was released in 2012 and uses various input para- meters associated with the latest rail vehicles and track systems in Germany. This version has not been sufficiently used in South Korea, and there is a lack of standard guidelines and a precise manual for Korean railway systems. Thus, it is not clear what input parameters will match specific local cases. This study investigates the modeling procedure for Korean railway systems and the differences between calcu- lated railway sound levels and measured values obtained using the Schall 03 2012 model. Depending on the location of sound receivers, the difference between the cal- culated and measured values was within approximately 4 dB for various train types. In the case of high-speed trains, the value was approximately 7 dB. A noise-reducing measure was also modeled. The noise reduction effect of a low-height noise barrier system was predicted and evaluated for operating railway sites within the frame- work of a national research project in Korea. The comparison of calculated and measured values showed differences within 2.5 dB.


Water ◽  
2021 ◽  
Vol 13 (1) ◽  
pp. 105
Author(s):  
Argelia E. Rascón-Ramos ◽  
Martín Martínez-Salvador ◽  
Gabriel Sosa-Pérez ◽  
Federico Villarreal-Guerrero ◽  
Alfredo Pinedo-Alvarez ◽  
...  

Understanding soil moisture behavior in semi-dry forests is essential for evaluating the impact of forest management on water availability. The objective of the study was to analyze soil moisture based in storm observations in three micro-catchments (0.19, 0.20, and 0.27 ha) with similar tree densities, and subject to different thinning intensities in a semi-dry forest in Chihuahua, Mexico. Vegetation, soil characteristics, precipitation, and volumetric water content were measured before thinning (2018), and after 0%, 40%, and 80% thinning for each micro-catchment (2019). Soil moisture was low and relatively similar among the three micro-catchments in 2018 (mean = 8.5%), and only large rainfall events (>30 mm) increased soil moisture significantly (29–52%). After thinning, soil moisture was higher and significantly different among the micro-catchments only during small rainfall events (<10 mm), while a difference was not noted during large events. The difference before–after during small rainfall events was not significant for the control (0% thinning); whereas 40% and 80% thinning increased soil moisture significantly by 40% and 53%, respectively. Knowledge of the response of soil moisture as a result of thinning and rainfall characteristics has important implications, especially for evaluating the impact of forest management on water availability.


2020 ◽  
Vol 7 (Supplement_1) ◽  
pp. S110-S110
Author(s):  
Christina Maguire ◽  
Dusten T Rose ◽  
Theresa Jaso

Abstract Background Automatic antimicrobial stop orders (ASOs) are a stewardship initiative used to decrease days of therapy, prevent resistance, and reduce drug costs. Limited evidence outside of the perioperative setting exists on the effects of ASOs on broad spectrum antimicrobial use, discharge prescription duration, and effects of missed doses. This study aims to evaluate the impact of an ASO policy across a health system of adult academic and community hospitals for treatment of intra-abdominal (IAI) and urinary tract infections (UTI). ASO Outcome Definitions ASO Outcomes Methods This multicenter retrospective cohort study compared patients with IAI and UTI treated before and after implementation of an ASO. Patients over the age of 18 with a diagnosis of UTI or IAI and 48 hours of intravenous (IV) antimicrobial administration were included. Patients unable to achieve IAI source control within 48 hours or those with a concomitant infection were excluded. The primary outcome was the difference in sum length of antimicrobial therapy (LOT). Secondary endpoints include length and days of antimicrobial therapy (DOT) at multiple timepoints, all cause in hospital mortality and readmission, and adverse events such as rates of Clostridioides difficile infection. Outcomes were also evaluated by type of infection, hospital site, and presence of infectious diseases (ID) pharmacist on site. Results This study included 119 patients in the pre-ASO group and 121 patients in the post-ASO group. ASO shortened sum length of therapy (LOT) (12 days vs 11 days respectively; p=0.0364) and sum DOT (15 days vs 12 days respectively; p=0.022). This finding appears to be driven by a decrease in outpatient LOT (p=0.0017) and outpatient DOT (p=0.0034). Conversely, ASO extended empiric IV LOT (p=0.005). All other secondary outcomes were not significant. Ten patients missed doses of antimicrobials due to ASO. Subgroup analyses suggested that one hospital may have influenced outcomes and reduction in LOT was observed primarily in sites without an ID pharmacist on site (p=0.018). Conclusion While implementation of ASO decreases sum length of inpatient and outpatient therapy, it may not influence inpatient length of therapy alone. Moreover, ASOs prolong use of empiric intravenous therapy. Hospitals without an ID pharmacist may benefit most from ASO protocols. Disclosures All Authors: No reported disclosures


2021 ◽  
pp. 153857442110232
Author(s):  
Spyridon N. Mylonas ◽  
Konstantinos G. Moulakakis ◽  
Nikolaos Kadoglou ◽  
Constantinos Antonopoulos ◽  
Thomas E. Kotsis ◽  
...  

Purpose: The aim of the present study was to investigate a potential difference on the arterial stiffness among aneurysm patients and non-aneurysm controls, as well as to explore potential changes between patients treated either with endovascular or open repair. Materials and Methods: A 110 patients with an infrarenal AAA were prospectively enrolled in this study. Fifty-six patients received an EVAR, whereas 54 patients received an open surgical repair. Moreover, 103 gender and age-matched subjects without AAA served as controls. The cardio-ankle vascular index (CAVI) was applied for measurement of the arterial stiffness. Results: CAVI values were statistically higher in the AAA patients when compared with control subjects. Although at 48 hours postoperatively the CAVI values were increased in both groups when compared to baseline values, the difference in CAVI had a tendency to be higher in the open group compared to the endovascular group. At 6 months of follow up the CAVI values returned to the baseline for the patients of the open repair group. However, in the endovascular group CAVI values remained higher when compared with the baseline values. Conclusion: Patients with AAAs demonstrated a higher value of CAVI compared to healthy controls. A significant increase of arterial stiffness in both groups during the immediate postoperative period was documented. The increase in arterial stiffness remained significant at 6 months in EVAR patients. Further studies are needed to elucidate the impact of a decreased aortic compliance after stentgraft implantation on the cardiac function of patients with AAA.


2020 ◽  
Vol 15 (S359) ◽  
pp. 188-189
Author(s):  
Daniela Hiromi Okido ◽  
Cristina Furlanetto ◽  
Marina Trevisan ◽  
Mônica Tergolina

AbstractGalaxy groups offer an important perspective on how the large-scale structure of the Universe has formed and evolved, being great laboratories to study the impact of the environment on the evolution of galaxies. We aim to investigate the properties of a galaxy group that is gravitationally lensing HELMS18, a submillimeter galaxy at z = 2.39. We obtained multi-object spectroscopy data using Gemini-GMOS to investigate the stellar kinematics of the central galaxies, determine its members and obtain the mass, radius and the numerical density profile of this group. Our final goal is to build a complete description of this galaxy group. In this work we present an analysis of its two central galaxies: one is an active galaxy with z = 0.59852 ± 0.00007, while the other is a passive galaxy with z = 0.6027 ± 0.0002. Furthermore, the difference between the redshifts obtained using emission and absorption lines indicates an outflow of gas with velocity v = 278.0 ± 34.3 km/s relative to the galaxy.


Sign in / Sign up

Export Citation Format

Share Document