scholarly journals Biochemical Constituent of Ginkgo biloba (Seed) 80% Methanol Extract Inhibits Cholinesterase Enzymes in Javanese Medaka (Oryzias javanicus) Model

2020 ◽  
Vol 2020 ◽  
pp. 1-11
Author(s):  
Ibrahim Hassan ◽  
Wan Norhamidah Wan Ibrahim ◽  
Ferdaus Mohamat Yusuf ◽  
Siti Aqlima Ahmad ◽  
Syahida Ahmad

Background. Pathophysiological changes leading to the death of nerve cells present in the brain and spinal cord are referred to as neurodegenerative diseases. Presently, treatment of these diseases is not effective and encounters many challenges due to the cost of drug and side effects. Thus, the search for the alternative agents to replace synthetic drugs is in high demand. Therefore, the aim of this study is to evaluate the anticholinesterase properties of Ginkgo biloba seed. Methods. The seed was extracted with 80% methanol. Toxicity studies and evaluation of anticholinesterase activities were carried out in adult Javanese medaka (Oryzias javanicus). Phytochemical study to identify the bioactive lead constituents of the crude extract was also carried out using high performance liquid chromatography (HPLC). Results. The result shows activities with high significant differences at P<0.001 between the treated and nontreated groups. A bioactive compound (vitaxin) was identified with the aid of HPLC method. Conclusion. The presence of bioactive compound vitaxin is among the major secondary metabolites that contribute to increasing activities of this plant extract. High anticholinesterase activities and low toxicity effect of this plant show its benefit to be used as natural medicine or supplements.

2019 ◽  
Vol 15 (3) ◽  
pp. 277-293 ◽  
Author(s):  
Sevinc Kurbanoglu ◽  
Ozer Karsavurdan ◽  
Sibel A. Ozkan

Introduction: Ultra-Performance Liquid Chromatographic (UPLC) method enables analyst to establish an analysis at higher pressure than High Performance Liquid Chromatographic (HPLC) method towards liquid chromatographic methods. UPLC method provides the opportunity to study a higher pressure compared to HPLC, and therefore smaller column in terms of particle size and internal diameter are generally used in drug analysis. The UPLC method has attracted gradually due to its advantages such as short analysis time, the small amount of waste reagents and the significant savings in the cost of their destruction process. In this review, the recent selected studies related to the UPLC method and its method validation are summarized. The drug analyses and the results of the studies which were investigated by UPLC method, with certain parameters from literature are presented. Background: Quantitative determination of drug active substances by High-Performance Liquid Chromatography (HPLC) from Liquid Chromatography (LC) methods has been carried out since the 1970's with the use of standard analytical LC methods. In today's conditions, rapid and very fast even ultra-fast, flow rates are achieved compared to conventional HPLC due to shortening analysis times, increasing method efficiency and resolution, reducing sample volume (and hence injection volume), reducing waste mobile phase. Using smaller particles, the speed and peak capacity are expanding to new limit and this technology is named as Ultra Performance Liquid Chromatography. In recent years, as a general trend in liquid chromatography, ultra-performance liquid chromatography has taken the place of HPLC methods. The time of analysis was for several minutes, now with a total analysis time of around 1-2 minutes. The benefits of transferring HPLC to UPLC are much better understood when considering the thousands of analyzes performed for each active substance, in order to reduce the cost of analytical laboratories where relevant analysis of drug active substances are performed without lowering the cost of research and development activities. Methods: The German Chemist Friedrich Ferdinand Runge, proposed the use of reactive impregnated filter paper for the identification of dyestuffs in 1855 and at that time the first chromatographic method in which a liquid mobile phase was used, was reviewed. Christian Friedrich Chönbein, who reported that the substances were dragged at different speeds in the filter paper due to capillary effect, was followed by the Russian botanist Mikhail S. Tswet, who planted studies on color pigment in 1906. Tswet observes the color separations of many plant pigments, such as chlorophyll and xanthophyll when he passes the plant pigment extract isolated from plant through the powder CaCO3 that he filled in the glass column. This method based on color separation gives the name of "chromatographie" chromatography by using the words "chroma" meaning "Latin" and "graphein" meaning writing. Results and Conclusion: Because the UPLC method can be run smoothly at higher pressures than the HPLC method, it offers the possibility of analyzing using much smaller column sizes and column diameters. Moreover, UPLC method has advantages, such as short analysis time, the small amount of waste reagents and the significant savings in the cost of their destruction process. The use of the UPLC method especially analyses in biological samples such as human plasma, brain sample, rat plasma, etc. increasingly time-consuming due to the fact that the analysis time is very short compared to the HPLC, because of the small amount of waste analytes and the considerable savings in their cost.


2021 ◽  
Vol 1 (1) ◽  
pp. 62-70
Author(s):  
Asrul Afandi ◽  
Shazani Sarijan ◽  
Ranajit Kumar Shaha

A solid-liquid extraction and an HPLC method for determination of rebaudioside A from the leave parts of Stevia rebaudiana were developed. Separation method consisted of solvent extraction of leaf powder using various solvents like petroleum ether, methanol, diethyl ether and butanol followed by its purification using high performance liquid chromatography in order to obtain bioactive compound rebaudioside A. This solvent selection is very important prior to alternative extraction methods since it can be used as a pre-extraction solvents, main solvents, or co-solvents. The problem of hydrolysable components and solvent removal difficulties in the conventional extraction led us to study further the effects of solvent properties on the conventional extraction using Soxhlet method in order to determine the best solvent or solvent mixture for high extraction yield of S. rebaudiana. The chromatographic separation was realized using a C18 column, mobile phase consisting of methanol: water with UV detection at 210 nm. Based on the yield of extraction and glycosides content, methanol was found to be best solvent.


PLoS ONE ◽  
2020 ◽  
Vol 15 (12) ◽  
pp. e0243175
Author(s):  
Takashi Ohtsuki ◽  
Kiyoaki Matsuoka ◽  
Yushiro Fuji ◽  
Yuzo Nishizaki ◽  
Naoko Masumoto ◽  
...  

A high-performance liquid chromatography (HPLC) method with relative molar sensitivity (RMS) based on 1H quantitative NMR spectroscopy (1H-qNMR) has been developed for food ingredients such as acteoside (verbascoside) and pedaliin (pedalitin-6-O-glucoside) without requiring authentic and identical standards as the reliable analytical methods. This method is used methyl 4-hydroxybenzoate (MHB) as an alternative reference standard. Each RMS is also calculated from the ratio of each analyte's molar absorption coefficient to that of MHB after correcting the purities of the analytes and reference standard by 1H-qNMR. Therefore, this method can quantify several analytes with metrological traceability to the International System of Units (SI) using the RMS and one alternative reference standard. In this study, the content of acteoside and pedaliin in several samples, such as dried sesame leaf powders and commercially processed foods, can be determined by the proposed RMS method and demonstrated in good agreement that obtained by a conventional method. Moreover, the proposed method yields analytical data with SI-traceability without the need for an authentic and identical analyte standard. Thus, the proposed RMS method is a useful and practical tool for determining acteoside and pedaliin in terms of the accuracy of quantitative values, the routine analysis, and the cost of reagents.


2021 ◽  
Vol 11 (11) ◽  
pp. 5113
Author(s):  
Joanna Rachtan-Janicka ◽  
Alicja Ponder ◽  
Ewelina Hallmann

The number of consumers seeking safe and health-beneficial foods is systematically increasing. Consumers demand more environmentally friendly and safe food options coming from organic farming. Blackcurrants fruits are a perfect source of biological active compounds, such as vitamin C, polyphenols and flavonoids as well anthocyanins. Organic agricultural practices have modified the level of bioactive compounds in blackcurrant fruits. The novelty and the aim of the presented study was to compare the concentrations of selected health-promoting antioxidants in fruits of three blackcurrants (‘Ben Adler’, ‘Tiben’ and ‘Titania’) grown in organic and conventional orchards in Poland. For bioactive compound determination, the high-performance liquid chromatography (HPLC) method was used. The obtained results showed that organic blackcurrant fruits contained significantly more vitamin C (9.4 mg/100 g f.w.), total polyphenols (189.2 mg/100 g f.w.), total phenolic acids (10.3 mg/100 g f.w.), and total flavonoids (178.8 mg/100 g f.w.), as well anthocyanins (167.9 mg/100 g f.w.), compared to conventional ones. The selected cultivars and the years of cultivation system affect the concentration of the measured polyphenols, with strong interactions between these factors. The experiment confirms the hypothesis that organic blackcurrants should be a very important part of well-balanced, healthy diet.


Author(s):  
Arun Kumar P. ◽  
Elangaimannan R.

The study was conducted to evolve Gloriosa superba for yield characters and alkalodi content for selecting elite genotypes for comercial exploitatio n. The genotypes were sowm in Variyankaval village, Udayarpalayam taluk of Ariyalur district, Tamil Nadu. The highest mean value for fresh and dry seed yield was observed in Chittor local. The genotype Mulanur local has recorded the highest mean value for number of pods per plant and number of seeds per pod and Arupukotai local excelled the general mean for the traits seeds per pod, fresh and dry seed yield and also for tuber characters. An investigation was carried out to quantify the colchicine (alkaloid) present in tubers by High Performance Liquid Chromatography (HPLC) method. The genotypes collected from Arupukotai recorded the highest colchicine content (0.760 mg/g) followed by Chittoor (0.578 mg/g) and Mulanur (0.496 mg/g) and there by these three genotypes were utilized for further crop improvement.


2020 ◽  
Vol 20 (13) ◽  
pp. 1053-1059
Author(s):  
Mahmoud M. Sebaiy ◽  
Noha I. Ziedan

Background: Allergic diseases are considered as the major burden on public health with increased prevalence globally. Histamine H1-receptor antagonists are the foremost commonly used drugs in the treatment of allergic disorders. The target drug in this study, loratadine, belongs to this class of drugs and its biometabolite desloratadine which is also a non-sedating H1 receptor antagonist with anti-histaminic activity being 2.5 to 4 times greater than loratadine. This study aimed to develop and validate a novel isocratic Reversed-phase High-Performance Liquid Chromatography (RP-HPLC) method for rapid and simultaneous separation and determination of loratadine and its metabolite, desloratadine in human plasma. Methods: The drug extraction method from plasma was based on protein precipitation technique. The separation was carried out on a Thermo Scientific BDS Hypersil C18 column (5μm, 250 x 4.60 mm) in a mobile phase of MeOH: 0.025M KH2PO4 adjusted to pH 3.50 using orthophosphoric acid (85: 15, v/v) at an ambient temperature. The flow rate was maintained at 1 mL/min and maximum absorption was measured using the PDA detector at 248 nm. Results: The retention times of loratadine and desloratadine in plasma samples were recorded to be 4.10 and 5.08 minutes, respectively, indicating a short analysis time. Limits of detection were found to be 1.80 and 1.97 ng/mL for loratadine and desloratadine, respectively, showing a high degree of sensitivity of the method. The method was then validated according to FDA guidelines for the determination of the two analytes in human plasma. Conclusion: The results obtained indicate that the proposed method is rapid, sensitive in the nanogram range, accurate, selective, robust and reproducible compared to other reported methods.


2020 ◽  
Vol 23 (10) ◽  
pp. 1010-1022
Author(s):  
Emrah Dural

Aim and scope: Due to the serious toxicological risks and their widespread use, quantitative determination of phthalates in cosmetic products have importance for public health. The aim of this study was to develop a validated simple, rapid and reliable high-performance liquid chromatography (HPLC) method for the determination of phthalates which are; dimethyl phthalate (DMP), diethyl phthalate (DEP), benzyl butyl phthalate (BBP), di-n-butyl phthalate (DBP), di(2- ethylhexyl) phthalate (DEHP), in cosmetic products and to investigate these phthalate (PHT) levels in 48 cosmetic products marketing in Sivas, Turkey. Materials and Methods: Separation was achieved by a reverse-phase ACE-5 C18 column (4.6 x 250 mm, 5.0 μm). As the mobile phase, 5 mM KH2PO4 and acetonitrile were used gradiently at 1.5 ml min-1. All PHT esters were detected at 230 nm and the run time was taking 21 minutes. Results: This method showed the high sensitivity value the limit of quantification (LOQ) values for which are below 0.64 μg mL-1 of all phthalates. Method linearity was ≥0.999 (r2). Accuracy and precision values of all phthalates were calculated between (-6.5) and 6.6 (RE%) and ≤6.2 (RSD%), respectively. Average recovery was between 94.8% and 99.6%. Forty-eight samples used for both babies and adults were successfully analyzed by the developed method. Results have shown that, DMP (340.7 μg mL-1 ±323.7), DEP (1852.1 μg mL-1 ± 2192.0), and DBP (691.3 μg mL-1 ± 1378.5) were used highly in nail polish, fragrance and cream products, respectively. Conclusion: Phthalate esters, which are mostly detected in the content of fragrance, cream and nail polish products and our research in general, are DEP (1852.1 μg mL-1 ± 2192.0), DBP (691.3 μg mL-1 ± 1378.5) and DMP (340.7 μg mL-1 ±323.7), respectively. Phthalates were found in the content of all 48 cosmetic products examined, and the most detected phthalates in general average were DEP (581.7 μg mL-1 + 1405.2) with a rate of 79.2%. The unexpectedly high phthalate content in the examined cosmetic products revealed a great risk of these products on human health. The developed method is a simple, sensitive, reliable and economical alternative for the determination of phthalates in the content of cosmetic products, it can be used to identify phthalate esters in different products after some modifications.


2020 ◽  
Vol 16 (7) ◽  
pp. 867-871
Author(s):  
Harun Ergen ◽  
Muge Guleli ◽  
Cigdem Sener ◽  
Cem Caliskan ◽  
Sercan Semiz ◽  
...  

Introduction: Polyvinyl alcohol (PVA), a polymer, is in demand due to its usage in different applications such as pharmaceutical, biomedical and textile, paper, food industries. Methods: A new sensitive reversed phased high-pressure liquid chromatography (RP-HPLC) method with refractive index detector (RID) was developed for determination of PVA in an ophthalmic solution containing dexpanthenol and PVA as active substances and it was validated according to The International Council for Harmonisation of Technical Requirements for Pharmaceuticals for Human Use (ICH) guideline. Results: Chromatographic separation was achieved on a Chiral-AGP (150 mm × 4.0 mm, 5 μm) column kept at 30°C with an isocratic flow at a flow rate of 1.0 ml/min. The detector temperature was 30°C, the retention time of PVA was around 1.0 min and the total run time was 5 minutes. Conclusion: The proposed method showed linearity, accuracy, precision, specificity, robustness, solution stability, and system suitability results within the acceptance criteria.


Antioxidants ◽  
2021 ◽  
Vol 10 (2) ◽  
pp. 245
Author(s):  
María de la Luz Cádiz-Gurrea ◽  
Diana Pinto ◽  
Cristina Delerue-Matos ◽  
Francisca Rodrigues

Olea europaea cultivar, native in the Mediterranean basin, has expanded worldwide, mainly due to the olive oil industry. This expansion is attributed to the benefits of olive oil consumption, since this product is rich in nutritional and bioactive compounds. However, the olive industry generates high amounts of wastes, which could be related to polluting effects on soil and water. To minimize the environmental impact, different strategies of revalorization have been proposed. In this sense, the aim of this work was to develop high cosmetic value added oleuropein-enriched extracts (O20 and O30), a bioactive compound from olive byproducts, performing a comprehensive characterization using high performance liquid chromatography coupled to mass spectrometry and evaluate their bioactivity by in vitro assays. A total of 49 compounds were detected, with oleuropein and its derivatives widely found in O30 extract, whereas iridoids were mainly detected in O20 extract. Moreover, 10 compounds were detected for the first time in olive leaves. Both extracts demonstrated strong antioxidant and antiradical activities, although O30 showed higher values. In addition, radical oxygen and nitrogen species scavenging and enzyme inhibition values were higher in O30, with the exception of HOCl and hyaluronidase inhibition assays. Regarding cell viability, olive byproduct extracts did not lead to a decrease in keratinocytes viability until 100 µg/mL. All data reported by the present study reflect the potential of industrial byproducts as cosmetic ingredients.


Molecules ◽  
2021 ◽  
Vol 26 (15) ◽  
pp. 4545
Author(s):  
Sudharsan Sadhasivam ◽  
Omer Barda ◽  
Varda Zakin ◽  
Ram Reifen ◽  
Edward Sionov

Patulin (PAT) and citrinin (CTN) are the most common mycotoxins produced by Penicillium and Aspergillus species and are often associated with fruits and fruit by-products. Hence, simple and reliable methods for monitoring these toxins in foodstuffs are required for regular quality assessment. In this study, we aimed to establish a cost-effective method for detection and quantification of PAT and CTN in pome fruits, such as apples and pears, using high-performance liquid chromatography (HPLC) coupled with spectroscopic detectors without the need for any clean-up steps. The method showed good performance in the analysis of these mycotoxins in apple and pear fruit samples with recovery ranges of 55–97% for PAT and 84–101% for CTN, respectively. The limits of detection (LOD) of PAT and CTN in fruits were 0.006 µg/g and 0.001 µg/g, while their limits of quantification (LOQ) were 0.018 µg/g and 0.003 µg/g, respectively. The present findings indicate that the newly developed HPLC method provides rapid and accurate detection of PAT and CTN in fruits.


Sign in / Sign up

Export Citation Format

Share Document