scholarly journals PERBEDAAN KEKASARAN PERMUKAAN BASIS RESIN AKRILIK POLIMERISASI PANAS MENGGUNAKAN BAHAN PUMIS, CANGKANG TELUR DAN PASTA GIGI SEBAGAI BAHAN POLES

Author(s):  
Syafrinani Syafrinani ◽  
Yudi Setiawan

Denture base widely were made from heat polymerized acrylic resin. Either one of physical properties on this material must be concern is surface roughness, rough surface could interfere patient’s comfort, and microbial colonization. Therefore polishing procedure were needed, polishing material that mostly used on acrylic resin was pumice, there is another alternative material i.e eggshell and toothpaste because had abrasive ability. The aim of this research is to determine the difference surface roughness of heat polymerized acrylic denture base resin used pumice, eggshell and toothpaste as polishing materials. The design research in this study is laboratory experimental with rectangle sample with size 50 x 20 x 3 ±1 mm. There are 30 samples for 3 groups. The result of this research shows a significant difference between pumice group and eggshell group with p value = 0,0001 (p < 0,05), pumice and toothpaste with p value = 0,0001 (p < 0,05), egghsell and toothpaste with p value = 0,032 (p < 0,05). Polishing that used an alternative material from eggshell and toothpaste produce lower surface roughness score rather than pumice.

Author(s):  
Saeed Noorollahian ◽  
Farinaz Shirban ◽  
Vahid Mojiri

Introduction: The daily use of orthodontic removable plates can interfere with the self-cleansing function of the mouth. Although various techniques have been proposed for cleaning removable orthodontic appliances, there is no consensus on the use of a safe method that preserves the physical properties of the appliance. This study aimed to investigate the effect of using hydrochloric acid (10%, for removal of mineral deposits) and sodium hypochlorite (5.25%, to remove organic matter and discolorations) on surface hardness and roughness of self-cure orthodontic acrylic resins. Materials & Methods: This cross-sectional laboratory study was conducted in the fall of 2017 at Isfahan University of Medical science and Isfahan University of Technology. In this study two orthodontic acrylic resins (Orthocryl® and Acropars®) were used. Eighty samples (12×10×3 mm) from each one were fabricated and divided into four groups (n = 20). Group 1: 15 minutes immersion in household cleaner liquid (Hydrochloric acid, 10%) followed by15 minutes immersion in household bleach liquid (Sodium Hypochlorite, 5.25%). In group 2, immersions were repeated just like group two times and in group 3, were done three times. Group 4 was as control and had no immersion. The surface hardness and roughness of samples were measured. Data were analyzed with Two Way ANOVA and the significance level was set at 0.05. Results: The number of immersion procedures did not significantly affect the surface hardness (p value = 0.958) and surface roughness (p value = 0.657) in the different study groups. There was no significant difference in the surface hardness between the two acrylic resin brands (p value = 0.077); however, Acropars acrylic resin samples exhibited significantly higher surface roughness compared to the Orthocryl acrylic resin samples(p value < 0.001). Conclusion: 15 minutes of immersion in 10% HCl, followed by 15 minutes of immersion in 5.25% NaOCl and repetition of the procedure three times did not significantly affect the surface hardness and roughness of self-cured acrylic resins.


2021 ◽  
Vol 17 (1) ◽  
pp. 22-26
Author(s):  
Kadek Ayu Wirayuni ◽  
◽  
I Made Hendri Dwi Saputra ◽  

Introduction: The denture base is the part of the removable denture that is supported by good adaptation to the underlying oral tissue. Most of the denture bases are made of acrylic or polymethyl methacrylate resin, better known as PMMA. However, the acrylic resin also has disadvantages such as easily broken and absorbs liquids both water and chemicals. The chemical absorption like alcohol, ethanol, and some drinks that contain acidic materials will chemically be induced with acrylic resin and settle in the pores of the acrylic resin. The chemical damage or defect creates roughness on the surface of the acrylic resin which can cause cracking or crazing and a decrease in surface strength and hardness. Materials and Methods: The method used in this research was a laboratory experimental design with a post-test-only control group using 12 samples consisting of 2 different types of samples by measuring the surface roughness of the acrylic resin after immersing the sample with a predetermined time. Results and Discussions: One-way ANOVA test results showed a significant difference in surface roughness after the samples immersion with a value of p = 0.006 (p <0.05). Conclusions: Based on this research, can be concluded that there is an increase in the surface roughness of the heated polymerized acrylic resin for 3 hours and 4 hours of immersion. The longer the heated polymerized acrylic resin is soaked in arak hence the level of surface roughness increases.


2019 ◽  
Vol S (1) ◽  
pp. 7-10
Author(s):  
Ahmed Asim Saeed Al-Ali ◽  
◽  
Ammar k. Al-Noori ◽  
Amer A. Taqa ◽  
◽  
...  

Objectives: Compare tensile and transverse strength of new copolymers for denture base. Materials and methods: The specimens were prepared from heat cured acrylic resin with three types of additives: Acryester B, Ethoxycarbonylethylene, and Propenoic acid at a percentage of 5% and 10%. The tensile and transverse strains were tested, recorded and compared. Results: The analysis of variance display statistically significant difference. The p-value was 0.001 for each of tensile and transverse strain tests. Conclusions: The tensile strength of the novel copolymers increased. The transverse strength of some of the novel copolymers increased.


2020 ◽  
Vol 8 (1) ◽  
pp. 48
Author(s):  
Muchammad Fahmi Rizqi Abdillah ◽  
FX Ady Soesetijo ◽  
Dewi Kristiana

The rough surface of a heat cured acrylic resin as a denture base can cause a pathogenic buildup of plaques and biofilms, so an effort to clean the denture base is needed. The available denture cleaning chemicals are proof of some disadvantages, so it is necessary to do research on alternative natural ingredients. Srikaya seed extract using ethanol 96% solvent has been shown to have antibacterial activity and with its various properties, so that it has the potential to become denture cleaning agents. Samples were made based on ADA No.17 specifications with 5 samples in each of the 6 treatment groups, sampling using Simple Random Sampling. Samples contaminated with S. mutans were soaked in srikaya seed extract 25%, 50%, 75%, 100%, 0.5% NaOCl and sterile aquadest. There was a significant difference (p <0.05) in each treatment group. There is an influence of the difference in concentration of srikaya seed extract on the growth of S. mutans bacteria on a heat cured acrylic base. Keywords: heat cured acrylic resin, S.mutans, srikaya seed extract, absorbance


2020 ◽  
Vol 5 (1) ◽  
pp. 36-43
Author(s):  
Gladis Aprilla Rizki ◽  
Sri Wahyuningsih Rais ◽  
Martha Mozartha

Alcoholic beverages can be consumed in any group age, and it may be consumed by an individual using denture. Fluid absorption by heat-cured acrylic resin as a material of a denture base was able to cause an increase in its surface roughness. Absorption of an organic solvent such as the ethanol in an alcoholic beverage(s) could even increase the effect. This study aimed to evaluate the effect of alcohol beverages on surface roughness of heat-cured acrylic resin denture base. Samples (n=24) were prepared from heat-cured acrylic resin (25x25x5 mm). They were divided into 4 groups and the pre-test surface roughness was measured. Samples of each group were immersed for 10 minutes into the solution (distilled water as the control group, beer, wine, and whiskey as the test groups). After stored in artificial saliva for 23 hours, the samples were immersed into the solution, completing a period of 24 hours. This procedure was performed for 7 consecutive days and the post-test surface roughness was measured. Data were statistically analyzed using the Kruskal-Walis test. There was a significant difference in surface roughness measurement before and after the immersion (p<0.05). Whiskey was most affecting the surface roughness of heat-cured acrylic resin denture base. Alcoholic beverages could increase the surface roughness of heat cure acrylic resin denture base. Keywords: Alcoholic beverages; Heat-cured acrylic denture base; Surface roughness


2021 ◽  
Vol 2021 ◽  
pp. 1-8
Author(s):  
Reem Abualsaud ◽  
Doaa M. Aleraky ◽  
Sultan Akhtar ◽  
Soban Q. Khan ◽  
Mohammed M. Gad

Objective. To evaluate the antimicrobial effects of different concentrations of zirconium dioxide nanoparticles (nano-ZrO2) reinforcement of poly(methyl) methacrylate (PMMA) on surface roughness and C. albicans biofilm. Methods. 20 heat-polymerized acrylic resin discs were conventionally made and divided into 4 groups (n = 5) according to nano-ZrO2 concentration: control (0% filler) and 3 experimental groups (2.5% (Z2.5), 5.0% (Z5.0), and 7.5% (Z7.5)). An optical profilometer was used for surface roughness evaluation, followed by Candida adherence assay. Specimens were sterilized, then immersed in cultured yeast (C. albicans), and incubated at 37°C for 48 hours. After that, discs were rinsed before extracting the clustered pellets of Candida. The attached C. albicans was counted using the direct method after spreading on agar media and incubating for 48 hours. Statistical analysis was performed using one-way ANOVA and Tukey’s post hoc test at α = 0.05. Results. Surface roughness was significantly increased with all modified groups compared with control ( P < 0.01 ), which showed the lowest roughness value (0.027 ± 0.004 μm). There was no significant difference in the roughness value among reinforced groups (2.5, 5.0, and 7.5%) ( P > 0.05 ), with Z7.5 showing the highest roughness value (0.042 ± 0.004 μm). Candida count was reduced as the nano-ZrO2 increased but not significantly ( P = 0.15 ). Conclusions. The addition of different concentrations of nano-ZrO2 particles to PMMA increased the surface roughness compared with control; in contrast, insignificant reduction of C. albicans biofilm was detected.


2016 ◽  
Vol 4 (3) ◽  
pp. 476-481 ◽  
Author(s):  
Amani Ramadan Moussa ◽  
Wessam Mohamed Dehis ◽  
Asmaa Nabil Elboraey ◽  
Hisham Samir ElGabry

AIM: This study aimed to verify the influence of oral environment and denture cleansers on the surface roughness and hardness of two different denture base materials. METHODS: A total of sixteen identical removable disc specimens (RDS) were processed. Eight RDS were made from heat-cured acrylic resin (AR) and the other eight were fabricated from thermoplastic injection moulded resin (TR). Surface roughness and hardness of DRS were measured using ultrasonic profilometry and Universal testing machine respectively. Then the four RDS (two AR and two of TR) were fixed to each maxillary denture, after three months RDS were retrieved. Surface roughness and hardness of RDS have measured again.RESULTS: The surface roughness measurements revealed no significant difference (p >0.05) for both disc groups at baseline. However, both groups showed a significant increase in the surface roughness after three months with higher mean value for (TR) group. On the other hand, the (AR) group showed higher hardness mean value than (TR) group at baseline with no significant decrease in the hardness values (p >0.05) following three months follow-up period. CONCLUSIONS: Denture cleansers have an effect on the denture’s surface roughness and hardness concurrently with an oral condition which will consequently influence the complete dentures’ lifetime and patients’ satisfaction.


2017 ◽  
Vol 29 (1) ◽  
Author(s):  
Pocut Aya Sofya ◽  
Liana Rahmayani ◽  
Rico Riski Candra Purnama

Introduction: The absorption of fluid in the heat cured acrylic resin is able to cause the increase in surface roughness. Absorption of acidic fluid such as soft drinks can cause even higher increase of surface roughness. The objective of this study was to determined the effect of soft drinks towards heat cured acrylic resin denture base surface roughness. Methods: Specimens of this study were 32 pieces of specimen with the size of 12×12×3 mm. Sixteen pieces of specimens were kept in aquadest as a control group and 16 pieces of specimens were immersed in the soft drinks as the treatment group. Initial surface roughness was measured using surface roughness tester. The specimens were then immersed in both immersion media for 2 days. After immersion, the surface roughness of specimens were measured again. Results: Data obtained on the roughness measurements were analyzed using paired t test with the results of the analysis showed a significant difference (p<0.05). Conclusion: It was concluded that there was increased in heat cured acrylic resin denture base surface roughness after immersed in soft drinks solvent.


2018 ◽  
Vol 1 (2) ◽  
pp. 114
Author(s):  
Wahdaniah Wahdaniah ◽  
Sri Tumpuk

Abstract: Routine blood examination is the earliest blood test or screening test to determine the diagnosis of an abnormality. Blood easily froze if it is outside the body and can be prevented by the addition of anticoagulants, one of which Ethylene Diamine Tetra Acetate (EDTA). Currently available vacuum tubes containing EDTA anticoagulants in the form of K2EDTA and K3EDTA. K3EDTA is usually a salt that has better stability than other EDTA salts because it shows a pH approaching a blood pH of about 6.4. The purpose of this research is to know the difference of erythrocyte index results include MCH, MCV and MCHC using K3EDTA anticoagulant with K2EDTA. This research is a cross sectional design. This study used venous blood samples mixed with K2EDTA anticoagulant and venous blood mixed with K3EDTA anticoagulants, each of 30 samples. Data were collected and analyzed using paired different test. Based on data analysis that has been done on MCH examination, p value <0,05 then there is a significant difference between samples with K3EDTA anticoagulant with K2EDTA to erythrocyte index value. Then on the examination of MCV and MCHC obtained p value <0.05 then there is no significant difference between samples with K3EDTA anticoagulant with K2EDTA to erythrocyte index value.Abstrak: Pemeriksaan darah rutin merupakan pemeriksaan darah yang paling awal atau screening test untuk mengetahui diagnosis suatu kelainan. Darah mudah membeku jika berada diluar tubuh dan bisa dicegah dengan penambahan antikoagulan, salah satunya Ethylene Diamine Tetra Acetate (EDTA). Dewasa ini telah tersedia tabung vakum yang sudah berisi antikoagulan EDTA dalam bentuk  K2EDTA dan  K3EDTA. K3EDTA  biasanya berupa garam yang mempunyai stabilitas yang lebih baik dari garam EDTA yang lain karena menunjukkan pH yang mendekati pH darah yaitu sekitar 6,4. Tujuan dari penelitian ini adalah untuk mengetahui perbedaan hasil indeks eritrosit meliputi MCH, MCV dan MCHC menggunakan antikoagulan K3EDTA dengan K2EDTA. Penelitian ini merupakan penelitian dengan desain cross sectional. Penelitian ini menggunakan sampel darah vena yang dicampur dengan antikoagulan K2EDTA dan darah vena yang dicampur dengan antikoagulan K3EDTA, masing-masing sebanyak 30 sampel. Data dikumpulkan dan dianalisis menggunakan uji beda berpasangan. Berdasarkan analisis data yang telah dilakukan pada pemeriksaan MCH didapatkan nilai p < 0,05 maka ada perbedaan yang signifikan antara sampel dengan antikoagulan K3EDTA dengan K2EDTA terhadap nilai indeks eritrosit. Kemudian pada pemeriksaan MCV dan MCHC didapatkan nilai p < 0,05 maka tidak ada perbedaan yang signifikan antara sampel dengan antikoagulan K3EDTA dengan K2EDTA terhadap nilai indeks eritrosit.


Polymers ◽  
2021 ◽  
Vol 13 (4) ◽  
pp. 543 ◽  
Author(s):  
Tzu-Yu Peng ◽  
Saiji Shimoe ◽  
Lih-Jyh Fuh ◽  
Chung-Kwei Lin ◽  
Dan-Jae Lin ◽  
...  

Poly(aryl–ether–ketone) materials (PAEKs) are gaining interest in everyday dental practices because of their natural properties. This study aims to analyze the bonding performance of PAEKs to a denture acrylic. Testing materials were pretreated by grinding, sandblasting, and priming prior to polymerization with the denture acrylic. The surface morphologies were observed using a scanning electron microscope and the surface roughness was measured using atomic force microscopy. The shear bond strength (SBS) values were determined after 0 and 2500 thermal cycles. The obtained data were analyzed using a paired samples t-test and Tukey’s honestly significant difference (HSD) test (α = 0.05). The surface characteristics of testing materials after different surface pretreatments showed obvious differences. PAEKs showed lower surface roughness values (0.02–0.03 MPa) than Co-Cr (0.16 MPa) and zirconia (0.22 MPa) after priming and sandblasting treatments (p < 0.05). The SBS values of PAEKs (7.60–8.38 MPa) met the clinical requirements suggested by ISO 10477 (5 MPa). Moreover, PAEKs showed significantly lower SBS reductions (p < 0.05) after thermal cycling fatigue testing compared to Co-Cr and zirconia. Bonding performance is essential for denture materials, and our results demonstrated that PAEKs possess good resistance to thermal cycling fatigue, which is an advantage in clinical applications. The results imply that PAEKs are potential alternative materials for the removable of prosthetic frameworks.


Sign in / Sign up

Export Citation Format

Share Document