scholarly journals Energy savings and emission reductions in industrial boilers

2011 ◽  
Vol 15 (3) ◽  
pp. 705-719 ◽  
Author(s):  
R. Saidur

In this paper energy use of boiler fan motors has been estimated using energy audit data. Energy savings using VSD by modulating fan speed has been estimated as well. Bill savings and associated emission reductions using VSD have been estimated and presented in this paper. It has been found that 139,412 MWh, 268,866, 159,328 MWh, and 99,580 MWh electrical energy can be saved for 40%, 60%, 80% and 100% motor loadings, respectively for 60% speed reduction. Corresponding bill savings for the aforementioned energy savings have been found to be US$7,318,335, US$14,113,933, US$8,363,812, and US135,911,944 for 40%, 60%, 80% and 100% motor loadings, respectively for 60% speed reduction. Along with energy savings, 69,770,744 kg, 134,558,329 kg, 79,738,065 kg, 49,836,603 kg of CO2 emission can be avoided for the associated energy savings as a result of energy savings using VSD for 40%, 60%, 80% and 100% motor loadings. Moreover, 32,503,558 GJ of fossil fuel can be saved for the flue gas temperature reduction as a result of reducing fan motor speed reduction. Flue gas energy savings for oxegen trim system has been estimated and found to be 549,310,130 GJ for 16.9% of excess air reduction with payback period less than a day.

Energies ◽  
2021 ◽  
Vol 14 (16) ◽  
pp. 4798
Author(s):  
Khan Rahmat Ullah ◽  
Marudhappan Thirugnanasambandam ◽  
Rahman Saidur ◽  
Kazi Akikur Rahman ◽  
Md. Riaz Kayser

Electric motors and boilers lead the industrial components which consume the largest portion of energy in an industry. This study explores the energy audit data of the condiment industry in India. The study mainly focuses on the estimation of the load factor, energy use, energy savings and annual bill savings with payback period of the electric motors of the plant. During the audit, it was found that there were several motors running under loaded conditions despite non-availability of variable speed drives installed in the plant. Therefore, variable speed drives are recommended to be installed to save energy by reducing the motors speed by up to 60%. According to the estimation, about 276 MWh, 551 MWh and 827 MWh electrical energy can be saved for 20%, 40% and 60% speed reduction of the motors using variable speed drives, respectively, where in most of the cases the payback period remains below 1 year. Furthermore, some suggestions are made to improve the poor power factor of running motors by using capacitor banks to save the reactive power. Besides, an estimation of energy saving is performed with a 2-ton capacity boiler. Since, there was no heat recovery system in the boiler; an air-preheater is suggested to be installed at the end of flue gas exhausting path of the boiler with the purpose of saving 68 tons of fuel per annum and having a payback period of 12 months. Moreover, a digital monitoring system, namely, “The Smart Joules” has been proposed to be installed in the plant aiming at saving about 3–5% of total energy per annum and having a payback period of 19 months. Finally, a summarization is made concluding in the fact that about 90 MWh energy and 95 tons of fuel can be saved (excluding motor energy savings) per annum by implementing proposed measures with a payback period of 15 months.


Solar Energy ◽  
2005 ◽  
Author(s):  
Abdelkarim Nemri ◽  
Moncef Krarti

This paper provides a simplified analysis tool to assess the energy saving potential of daylighting for commercial buildings through skylights. Specifically, the impact of daylighting is investigated for various fenestration opening sizes, glazing types, control strategies, and geographic locations. A top floor of a prototypical office building has been considered in the analysis. The results obtained for the office building can be applied to other types of buildings such as retails stores, schools, and warehouses. Based on the simulation analysis results, it was determined that skylight to floor ratio more than 0.3 does not affect significantly the lighting energy savings. An optimum value of skylight to floor area ratio was found to be 0.2 to minimize the annual total building energy use.


Energies ◽  
2019 ◽  
Vol 12 (4) ◽  
pp. 685 ◽  
Author(s):  
Antonio Peña-García ◽  
Ferdinando Salata ◽  
Iacopo Golasi

The high energy consumption of the lighting installations in highway tunnels has become a hot topic in the last few years due to the high figures in terms of money, consumed energy, use of raw materials, emissions of greenhouse gases due to the remarkable number of manufactured elements, and maintenance, among others. In spite of the different strategies proposed up to date and their savings, the potential benefits of decreasing the maximum speed allowed in tunnels have not been considered in depth as a complementary measure yet. In this work, the impact of such a decrease in terms of energy consumption, number projectors, carbon dioxide (CO2) emissions, and yearly costs in energy is analyzed and discussed. The results strongly suggest the convenience of introducing maximum speed reduction in traffic regulations which, in addition, could create positive synergies with traffic safety.


2018 ◽  
Vol 16 (1) ◽  
pp. 8
Author(s):  
Syamsuar Syamsuar

The use of energy in the air system of PT. Bank Aceh Lhokseumawe branch annually averages 60 - 75% of total energy consumption in buildings. The purpose of this research is to optimize energy use in air system continuously using Six Sigma approach. The six sigma approach is expected to reduce the cost of using the air system system without neglecting the comfort level according to the national comfort standard (SNI). The problem faced by the air system is the existence of over cooling load (over cooling load), the value reaches the figure beyond the initial 60,000 watts planning capacity. The calculation results obtained actual average cooling load reached 75,580.3 watts. It is known that the cooling overload is caused by several factors, namely: the quantity of occupant / human, the air ventilation factor, the management factor of electric appliances usage, the lighting factor, and the solar radiation / transmission factor. Solutions to improve the air conditioning system by minimizing the factors that cause over cooling load. The results of the improvement get a cooling load of 57,340.9 watts which means savings of 24.2%, or monthly electrical energy savings of 4,428.324 kwh / month or equivalent to 50,739.888 kwh / year. Keywords: cooling load, six sigma, optimization, critical to quality


Author(s):  
Peter Rez

Everything that rolls along the ground uses energy to overcome both rolling resistance and air resistance. Air resistance is more significant at higher speeds. Repeated accelerations dominate energy use in stop–start city driving. Not surprisingly, heavy, large SUVs use more energy to go a given distance than lighter, more streamlined cars. Due to the mismatch between the torque required and the rotation rate of the drive wheels, internal combustion engines in cars or trucks do not operate at their peak efficiency. Trains are the most efficient form of ground transportation due to both the lower rolling resistance of steel wheels on railroad tracks and the lower air resistance of its long and thin structure. A further advantage is that rail with fixed tracks can take advantage of the efficient generation of electrical energy. This is also obviously the main disadvantage; trains can only go where tracks have been laid.


Energies ◽  
2021 ◽  
Vol 14 (8) ◽  
pp. 2174
Author(s):  
Marta Marczak-Grzesik ◽  
Stanisław Budzyń ◽  
Barbara Tora ◽  
Szymon Szufa ◽  
Krzysztof Kogut ◽  
...  

The research presented by the authors in this paper focused on understanding the behavior of mercury during coal combustion and flue gas purification operations. The goal was to determine the flue gas temperature on the mercury emissions limits for the combustion of lignites in the energy sector. The authors examined the process of sorption of mercury from flue gases using fine-grained organic materials. The main objectives of this study were to recommend a low-cost organic adsorbent such as coke dust (CD), corn straw char (CS-400), brominated corn straw char (CS-400-Br), rubber char (RC-600) or granulated rubber char (GRC-600) to efficiently substitute expensive dust-sized activated carbon. The study covered combustion of lignite from a Polish field. The experiment was conducted at temperatures reflecting conditions inside a flue gas purification installation. One of the tested sorbents—tire-derived rubber char that was obtained by pyrolysis—exhibited good potential for Hg0 into Hg2+ oxidation, resulting in enhanced mercury removal from the flue. The char characterization increased elevated bromine content (mercury oxidizing agent) in comparison to the other selected adsorbents. This paper presents the results of laboratory tests of mercury sorption from the flue gases at temperatures of 95, 125, 155 and 185 °C. The average mercury content in Polish lignite was 465 μg·kg−1. The concentration of mercury in flue gases emitted into the atmosphere was 17.8 µg·m−3. The study analyzed five low-cost sorbents with the average achieved efficiency of mercury removal from 18.3% to 96.1% for lignite combustion depending on the flue gas temperature.


Energies ◽  
2021 ◽  
Vol 14 (3) ◽  
pp. 749
Author(s):  
John H. Scofield ◽  
Susannah Brodnitz ◽  
Jakob Cornell ◽  
Tian Liang ◽  
Thomas Scofield

In this work, we present results from the largest study of measured, whole-building energy performance for commercial LEED-certified buildings, using 2016 energy use data that were obtained for 4417 commercial office buildings (114 million m2) from municipal energy benchmarking disclosures for 10 major U.S. cities. The properties included 551 buildings (31 million m2) that we identified as LEED-certified. Annual energy use and greenhouse gas (GHG) emission were compared between LEED and non-LEED offices on a city-by-city basis and in aggregate. In aggregate, LEED offices demonstrated 11% site energy savings but only 7% savings in source energy and GHG emission. LEED offices saved 26% in non-electric energy but demonstrated no significant savings in electric energy. LEED savings in GHG and source energy increased to 10% when compared with newer, non-LEED offices. We also compared the measured energy savings for individual buildings with their projected savings, as determined by LEED points awarded for energy optimization. This analysis uncovered minimal correlation, i.e., an R2 < 1% for New Construction (NC) and Core and Shell (CS), and 8% for Existing Euildings (EB). The total measured site energy savings for LEED-NC and LEED-CS was 11% lower than projected while the total measured source energy savings for LEED-EB was 81% lower than projected. Only LEED offices certified at the gold level demonstrated statistically significant savings in source energy and greenhouse gas emissions as compared with non-LEED offices.


2021 ◽  
Vol 11 (14) ◽  
pp. 6254
Author(s):  
Elena G. Dascalaki ◽  
Constantinos A. Balaras

In an effort to reduce the operational cost of their dwellings, occupants may even have to sacrifice their indoor thermal comfort conditions. Following the economic recession in Greece over recent years, homeowners have been forced to adapt their practices by shortening heating hours, lowering the indoor thermostat settings, isolating spaces that are not heated or even turning off their central heating system and using alternative local heating systems. This paper presents the results from over 100 occupant surveys using questionnaires and walk-through energy audits in Hellenic households that documented how occupants operated the heating systems in their dwellings and the resulting indoor thermal comfort conditions and actual energy use. The results indicate that the perceived winter thermal comfort conditions were satisfactory in only half of the dwellings, since the actual operating space heating periods averaged only 5 h (compared with the assumed 18 h in standard conditions), while less than half heated their entire dwellings and only a fifth maintained an indoor setpoint temperature of 20 °C, corresponding to standard comfort conditions. Mainstream energy conservation measures include system maintenance, switching to more efficient systems, reducing heat losses and installing controls. This information is then used to derive empirical adaptation factors for bridging the gap between the calculated and actual energy use, making more realistic estimates of the expected energy savings following building renovations, setting prudent targets for energy efficiency and developing effective plans toward a decarbonized building stock.


Energies ◽  
2021 ◽  
Vol 14 (13) ◽  
pp. 3876
Author(s):  
Sameh Monna ◽  
Adel Juaidi ◽  
Ramez Abdallah ◽  
Aiman Albatayneh ◽  
Patrick Dutournie ◽  
...  

Since buildings are one of the major contributors to global warming, efforts should be intensified to make them more energy-efficient, particularly existing buildings. This research intends to analyze the energy savings from a suggested retrofitting program using energy simulation for typical existing residential buildings. For the assessment of the energy retrofitting program using computer simulation, the most commonly utilized residential building types were selected. The energy consumption of those selected residential buildings was assessed, and a baseline for evaluating energy retrofitting was established. Three levels of retrofitting programs were implemented. These levels were ordered by cost, with the first level being the least costly and the third level is the most expensive. The simulation models were created for two different types of buildings in three different climatic zones in Palestine. The findings suggest that water heating, space heating, space cooling, and electric lighting are the highest energy consumers in ordinary houses. Level one measures resulted in a 19–24 percent decrease in energy consumption due to reduced heating and cooling loads. The use of a combination of levels one and two resulted in a decrease of energy consumption for heating, cooling, and lighting by 50–57%. The use of the three levels resulted in a decrease of 71–80% in total energy usage for heating, cooling, lighting, water heating, and air conditioning.


2012 ◽  
Vol 16 (3) ◽  
pp. 131
Author(s):  
Didik Ariwibowo

Didik Ariwibowo, in this paper explain that energy audit activities conducted through several phases, namely: the initial audit, detailed audit, analysis of energy savings opportunities, and the proposed energy savings. Total energy consumed consists of electrical energy, fuel, and materials in this case is water. Electrical energy consumption data obtained from payment of electricity accounts for a year while consumption of fuel and water obtained from the payment of material procurement. From the calculation data, IKE hotels accounted for 420.867 kWh/m2.tahun, while the IKE standards for the hotel is 300 kWh/m2.tahun. Thus, IKE hotel included categorized wasteful in energy usage. The largest energy consumption on electric energy consumption. Largest electric energy consumption is on the air conditioning (AC-air conditioning) that is equal to 71.3%, and lighting and electrical equipment at 27.28%, and hot water supply system by 4.44%. Electrical energy consumption in AC looks very big. Ministry of Energy and Mineral Resources of the statutes, the profile of energy use by air conditioning at the hotel by 48.5%. With these considerations in the AC target for audit detail as the next phase of activity. The results of a detailed audit analysis to find an air conditioning system energy savings opportunities in pumping systems. Recommendations on these savings is the integration of automation on the pumping system and fan coil units (FCU). The principle of energy conservation in the pumping system is by installing variable speed drives (VSD) pump drive motor to adjust speed according to load on the FCU. Load variations FCU provide input on the VSD pumps to match. Adaptation is predicted pump can save electricity consumption up to 65.7%. Keywords: energy audit, IKE, AC